(HTKB632)
DOSEN:
1. RISWAN, S.T., M.T.
2. KARINA SHELLA PUTRI, S.T., M.T.
PERHITUNGAN JARINGAN
VENTILASI
HEAD VS KUANTITAS VS TAHANAN
𝐻~𝑄2 (PERSAMAAN HEAD LOSS)
2 2
𝐻1 𝑄1 𝑄2
= ATAU 𝐻2 = 𝐻1
𝐻2 𝑄2 𝑄1
A B B
A
R1 𝑅𝑒𝑞 = 𝑅1 + 𝑅2 + 𝑅3
𝐻
R3 𝑅𝑒𝑞 = 𝐿ൗ 2
Q 𝑄
Q
R2 Q
JARINGAN PARALEL
HUKUM KIRCHOFF 1
a d i 𝑄 = 𝑄1 + 𝑄2 + 𝑄3 + ⋯
HUKUM KIRCHOFF 2
b e h
𝐻𝐿 = 𝐻𝐿1 = 𝐻𝐿2 = 𝐻𝐿3 = …
c f g
𝐻𝐿 𝐻𝐿 𝐻𝐿
d 𝑄= ൗ𝑅1 + ൗ𝑅2+ ൗ𝑅3 atau
a e i
𝑄= 𝐻𝐿 1൘ + 1൘ + 1൘ = 𝐻𝐿 1ൗ𝑅
𝑅1 𝑅2 𝑅3 𝑒𝑞
b h
c f g
1 1 1 1
= + + +…
𝑅𝑒𝑞 𝑅1 𝑅2 𝑅3
JARINGAN KOMPLEKS
JIKA SIRKUIT-SIRKUIT PARALEL
A H SALING TUMPANG DAN TERKAIT
1/2” 1”
25.000 2”
C 40.000 3” D 1”
B G
B TIDAK DAPAT DISEDERHANAKAN
10.000 MENJADI SALURAN EKUIVALEN
1/2”
15.000 1/2” 2”
3” 35.000 1”
E F
20.000 3”
CONTROLLED SPLITTING
o JIKA SALURAN UDARA SECARA PARALEL DAN JUMLAH UDARA YANG
MENGALIR KE SETIAP CABANGNYA DITENTUKAN
o CARA KONTROL → MEMBUAT TAHANAN (RESISTEN) BUATAN PADA SALAH
SATU CABANG
o FREE SPLIT: CABANG YANG TIDAK DIBERI TAHANAN BUATAN
o REGULATOR: ALAT YANG MENIMBULKAN SHOCK LOSS UNTUK MENGONTROL
TAHANAN
o TUJUAN → PENGATURAN JUMLAH ALIRAN UDARA KE MUKA KERJA SESUAI
KEBUTUHAN
o EFEK → HEAD TOTAL & KEBUTUHAN DAYA MENINGKAT
→ PENINGKATAN BIAYA
UKURAN REGULATOR
SALURAN Q
R x 1010 HL (in) Mx (in)
UDARA (cfm)
1 20.000 23,50 0,940 Free Split
2 15.000 1,35 0,30 (0,940 - 0,030) = 0,910
3 35.000 3,12 0,382 (0,940 - 0,382) = 0,559
4 30.000 3,55 0,320 (0,940 – 0,320) = 0,620
UKURAN REGULATOR (LANJUTAN)
KOEFISIEN KONTRAKSI (SALURAN POJOK SIKU, Z = 2,50
N 0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1,0 BERDASARKAN PERHITUNGAN
Cc 0,63 0,64 0,65 0,67 0,69 0,71 0,75 0,81 0,88 1,0 SHOCK LOSS SECARA LANGSUNG :
𝐻𝑥 = 𝑋𝐻𝑣
X 217,97 46,38 17,03 7,61 3,67 1,78 0,81 0,30 0,07 0
2
FAKTOR KONTRAKSI KOEFISIEN SALURAN MASUK 1ൗ
𝑋= 𝐶𝑐 − 𝑁 𝑁
EDGE Z EDGE Z Cc X
FORMED 1,05 FORMED 1,05 0,975 0,0006
KETERANGAN:
ROUNDED 1,50 ROUND 1,5 0,785 0,05 N = RATIO LUAS REGULATOR/ LUAS LUBANG BUKAAN
Cc = KOEFISIEN KONTRAKSI
SMOOTH 2,00 SQUARE 2,50 0,630 0,34 X = FAKTOR SHOCK LOSS
Z = FAKTOR KONTRAKSI
SQUARE 2,50 Hx = SHOCK LOSS YG HARUS DITIMBULKAN REGULATOR
SHARP 3,80 Hv = VELOCITY HEAD
PERATURAN KESELAMATAN
KANDUNGAN OKSIGEN DAN KARBONDIOKSIDA KEPEMEN PE NO.
VOLUME DAN KECEPATAN UDARA VENTILASI 555.K/26/M.PE/1995
TEMPERATUR DAN KELEMBABAN RELATIVE
KANDUNGAN GAS-GAS BERACUN, BERHAHAYA, DAN MUDAH TERBAKAR
STRUKTUR PIT DARI SEGI VENTILASI
SISTEM TERPUSAT DAN SISTEM DIAGONAL
SISTEM TERPUSAT (INTAKE AIRWAY DAN RETURN AIRWAY SALING
BERDEKATAN) → KONSTRUKSI AWAL TBT
SISTEM DIAGONAL (INTAKE AIRWAY DAN RETURN AIRWAY TERPISAH
JAUH) → PENGEMBANGAN DAN PERLUASAN AREA PENAMBANGAN
TIDAK ADA KEKHAWATIRAN EXHAUST AIR BERCAMPUR KE DALAM INTAKE
AIR AKIBAT ARAH ANGIN
STRUKTUR PIT DARI SEGI VENTILASI
(LANJUTAN)
PEMBAGIAN ALIRAN UDARA
TAHANAN VENTILASI LEBIH KECIL → 1 FAN UNTUK VENTILASI UDARA LEBIH
BANYAK
SUPPLY UDARA SEGAR KE SETIAP MUKA KERJA SETIAP BLOK
PENGARUH KERUSAKAN AIRWAY DAPAT DIBATASI 1 BLOK SAJA
PENGARUH KEBAKARAN, SEMBURAN GAS, SWABAKAR, DAN LEDAKAN DAPAT
DIBATASI 1 BLOK SAJA
MENGURANGI KECEPATAN ANGIN TEROWONGAN UTAMA
TEMPERATUR RELATIF RENDAH HINGGA DEKAT MUKA KERJA
VENTILASI UTAMA – JENIS VENTILASI UTAMA
METODE PEMBANGKITAN DAYA VENTILASI
VENTILASI ALAMI
VENTILASI MESIN
TEKANAN PADA VENTILASI MESIN
VENTILASI TIUP
VENTILASI SEDOT
LETAK INTAKE DAN OUTTAKE AIRWAY
VENTILASI TERPUSAT
VENTILASI DIAGONAL
VENTILASI UTAMA – VENTILASI ALAMI
MUSIM MUSIM
DINGIN PANAS
L ` L
`
KETERANGAN:
h = TEKANAN VENTILASI (mmaq)
4,17 L = BEDA TINGGI (m)
ℎ= 𝐿 𝑡 − 𝑡𝑎
1000 t = TEMPERATUR EXHAUST (oC)
ta = TEMPERATUR UDARA LUAR (oC)
VENTILASI UTAMA – VENTILASI MESIN
DAYA ℎ𝑄
PENGGERAK
𝑁= MINE FAN = 1,5 – 3 KALI N
75
Keterangan :
N = daya penggerak udara (HP)
TAHANAN h = tahanan ventilasi (mm)
VENTILASI Q = jumlah angina ventilasi (m3/s)
DAYA VENTILASI (CONTOH SOAL)
BERAPAKAH DAYA PENGGERAK UDARA YANG DIBUTUHKAN PADA SUATU
TUNNEL DENGAN TEKANAN VENTILASI 150 mm DAN DEBIT ANGIN 150
m3/s?
150 × 150 ~ 1,5 KALI
𝑁= = 300 𝐻𝑃
75
1. PERBEDAAN TEKANAN EFEKTIF KIPAS ANGIN BERBANDING LURUS DENGAN KUADRAT JUMLAH
PUTARAN
3002
TEKANAN MENJADI → 80 𝑚𝑚 × = 180 𝑚𝑚
2002
2. KAPASITAS ANGIN PADA KIPAS ANGIN BERBANDING LURUS DENGAN JUMLAH PUTARAN
300
JUMLAH ANGIN MENJADI → 4.700 𝑚3 × = 7.050 𝑚3
200
3. DAYA PENGGERAK UDARA KIPAS ANGIN BERBANDING LURUS DENGAN 3 JUMLAH PUTARAN ATAU
JUMLAH ANGIN
3002
DAYA PENGGERAK MENJADI → = 3,375 𝑘𝑎𝑙𝑖𝑛𝑦𝑎
2002
TEORI KIPAS ANGIN – KURVA KARAKTERISTIK
(CONTOH)
PENGUKURAN – KECEPATAN ANGIN
ANEMOMETER TABUNG PITOT
𝛾𝑣 2൘
∆𝑃 = 2𝑔
KETERANGAN:
ΔP = TEKANAN DINAMIS
γ = BERAT JENIS UDARA
v = KECEPATAN ANGIN
g = PERCEPATAN GRAVITASI
PENGUKURAN – TEKANAN UDARA
BAROMETER
AIR RAKSA
BAROMETER ANEROID
TUGAS VENTILASI TAMBANG
SOAL 1
0,1
A 2 R= 0,6 Ns2/m8
0,15
1
C 5
0,3
0,12 3
4 0,1
8
10
7 B
6
0,17
9
D
140 - Q
SOAL 2-SOLUSI
APLIKASIKAN HUKUM KIRCHOFF II
𝐻𝐿 = 𝑅𝑎 𝑄1 2 + 𝑅𝑏 𝑄1 2 + 𝑅𝑐 𝑄1 2 − 𝑅𝑑 𝑄2 2 = 0 ………….. (Pa)
Pb MESH 1 =
MESH 1 Pb MESH 2
BRANCH FRICTIONAL PRESSURE DROP (RQ2) FAN
AB … -
BC … -Pb DISTRIBUSI
TENTUKAN
CA … - NILAI Q TIAP
NILAI Q
CABANG
MESH 2
BRANCH FRICTIONAL PRESSURE DROP (RQ2) FAN
BD … - HITUNG
NILAI Pb
CD … -
BC … Pb
TERIMAKASIH