Anda di halaman 1dari 7

10 HEATER

Fungsi : Menaikkan temperatur feed (KD-01)


Gambar :

Fluida panas : Steam


W = 239.40 kg/jam = 527.79 lb/jam
T1 = 300 ℃ = 572 ℉
T2 = 300 ℃ = 572 ℉

Fluida dingin : Crude Yodium Pentafluorida


W = 18136.67 kg/jam = 39984.52 lb/jam
T1 = 50 ℃ = 122.00 ℉
T2 = 111.8 ℃ = 233.24 ℉

Panas yang ditransfer, Qtr


Qtr = 80312.11 kkal/jam = 318702.55 Btu/jam

1). Menghitung selisih temperatur, LMTD


Fluida panas Temperatur Fluida dingin Selisih
572 ℉ Tinggi 233.24 ℉ 338.76 ℉
572 ℉ Rendah 122.00 ℉ 450.00 ℉
0℉ Selisih 111.24 ℉ 111.24 ℉

∆𝐿𝑀𝑇𝐷= (∆𝑡2 −
∆𝑡1)/ln⁡(∆𝑡2/∆𝑡1)

= (450
−338,76)/ln⁡
(450/338,7
6)
= 391.75 ℉

2). Temperatur rata-rata


T avg = 1/2 x (T1 +T2)
= 572 ℉

t avg = 1/2 x (t1 + t2)


= 177.62 ℉

3). Trial harga UD


Asumsi harga UD = 74.0 Btu/hr ft² ℉

A = 𝑄𝑡𝑟/(𝑈_𝑑
𝑥 𝐿𝑀𝑇𝐷) ²〖𝑓𝑡〗 ^2
= 10.994 ft²

Karena A<200 ft^2, maka direncanakan memilih alat penukar panas tipe
Double Pipe Heat Exchanger (DPHE) dengan spesifikasi (Kern, tabel 11)
ukuran pipa dalam dan pipa luar yang dipilih 3" x 2,5". Pemilihan ukuran
pipa dia benar jika hasil perhitungan nantinya diperoleh perbedaan tekanan
dalam pipa dan masing-masing kecil dari 10 psi.

Mengingat pipa dalam yang digunakan berukuran 2,5 in, maka untuk harga luas
pipa (a') dari tabel 11 kern didapat :
a' = 0.753 ft²/ft

Panjang pipa L =
𝐴/𝑎^′
= 14.60 ft

Dipilih alat HE sebagai berikut:


Hairpin = 2 buah
Panjang = 3.80 ft

Panjang pipa total = 2 x 2 x 3,80


= 15.20 ft

Koreksi luas (luas permukaan sebenarnya) :


A = L x a'
= 11.45 ft²

Koreksi harga UD
UD =𝑄/(𝐴. ∆𝑡)

= (318702,55)/(11,45 x 391,75)
= 71.08 Btu/hr ft² ℉

Karena UD mendekati harga UD asumsi, maka asumsi ukuran pipa dapay dipakai:
Sumber : (Kern tabel 11, p.844)

Annulus Inner Pipe


IPS = 3.0 in IPS = 2.5 in
ID = 3.068 in ID = 2.469 in
OD = 3.5 in OD = 2.88 in
SN = 40 SN = 40
a= 7.4 ft²/ft a = 0.753 ft²/ft

4). ANNULUS : FLUIDA PANAS, STEAM


(1). Flow area
D2 = 3.068 in = 0.26 ft
D1 = 2.880 in = 0.24 ft

𝑎_𝑎 = ( 𝜋 ( 〖𝐷 _2 〗 ^2−
〖𝐷 _1 〗 ^2 ))/4
= 0.006 ft²

Equivalent diameter
𝐷_𝑒=
( 〖𝐷 _2 〗 ^2 −
〖𝐷 =_1 〗 ^2)/𝐷 0.03 ft
_1
(2). Laju alir massa
𝐺_𝑎 =
𝑊/𝑎_𝑎
= 86650.29 lb/jam ft²

(3). Pada Tc = 572 ℉


𝜇 = 0.02 cp = 0.05 lb/hr ft
𝑅_𝑒𝑎 = (𝐷_𝑒
𝑥 𝐺_𝑎)/𝜇
= 57925.48

(4). JH pada Rea 57925,48 adalah = 170 (Sumber Fig.24 Kern)

(5). Pada Tc = 572 ℉


Kapasitas panas steam (c) = 0.27 Btu/lb ℉
Konduktivitas Thermal (k) = 0.0280 Btu/hr ft² ℉/ft

(6). ℎ_𝑜 = JH [𝑘/𝐷_𝑒 ]


[(𝑐 . 𝜇)/𝑘]^(1/3)∅
= 114.43 Btu/hr ft² ℉

5). INNER PIPE : Crude Yodium Pentafluorida


(1). Flow area
D = 2.880 in = 0.24 ft
𝑎_𝑎 = ( 𝜋 𝐷^2 )/4

= 0.05 ft²
(2). Laju alir massa
𝐺_𝑝 =
𝑊/𝑎_𝑝
= 885008.11 lb/jam ft²

(3). Pada Tc = 177.62 ℉


𝜇 = 0.39 cp = 0.94 lb/hr ft
𝑅_𝑒𝑎 = (𝐷 𝑥
𝐺_𝑎)/𝜇
= 225044.53

(4). JH pada Rea 224044,53 adalah = 290 (Sumber Fig.24 Kern)

(5). Pada Tc = 177.62 ℉


Kapasitas panas steam (c) = 1.68 Btu/lb ℉ Sumber (Fig.3 kern)
Konduktivitas Thermal (k) = 1.97 Btu/hr ft² ℉/ft

(6). ℎ_𝑖 = JH [𝑘/𝐷] [(𝑐 .


𝜇)/𝑘]^(1/3)∅
= 2216.47 Btu/hr ft² ℉

(7). ℎ_𝑖𝑜 = ℎ_𝑖


[𝐼𝐷/𝑂𝐷]
OD = 2.469 in
ID = 2.88 in

ℎ_𝑖𝑜 = ℎ_𝑖
[𝐼𝐷/𝑂𝐷]
= 2585.43 Btu/hr ft² ℉

6). Clean Overall Coefficient


𝑈_𝑐 = (ℎ_(𝑖𝑜 )
𝑥 ℎ_𝑜)/(ℎ_𝑖𝑜
+ ℎ_𝑜
= ) 109.58 Btu/hr ft² ℉

7). Design Overall Coefficient


1/𝑈_𝑑 = Rd diasumsikan = 0.003
1/𝑈_𝑐 + 𝑅_𝑑
1/𝑈_𝑑 0.012
= 82.47 Btu/hr ft² ℉
𝑈_𝑑 =

8). Required Surface Area


A = 𝑄/(𝑈_𝑑 𝑥
∆𝑡 )
A = 𝑄/(𝑈_𝑑 𝑥
∆𝑡 )
= 9.86 ft²

External surface / lin ft, a = 0.75 ft²/ft


Panjang pipa, A/a" = 14.42 ft
Dipakai Hairpin yang panjangnya = 3.80 ft

Maka jumlah hairpin :


=
14,42/
(3,8 𝑥
= 1.90 (Dibutuhkan 2 buah)
2)
=2

Koreksi panjang pipa :


=2 x 2 x 4
= 15.2 ft

9). Actual surface area


A = 15,2 x 0,75
= 11.38 ft²

10). Actual Design Overall Coefficient


𝑈_𝐷 = 𝑄/(𝐴 𝑥 ∆𝑡
)
= 71.46 Btu/hr ft² ℉

11). Dirt Factor Coefficient


𝑅_𝐷 = (𝑈_𝐶 −
𝑈_𝐷)/(𝑈_𝐶 𝑥
𝑈_𝐷 =) 0.0049


²〖𝑓𝑡〗 ^2

𝑈_𝐷

Anda mungkin juga menyukai