Presentasi 130523
Presentasi 130523
European HQ
Fyfe Europe Ltd (Greece) Global HQ
Fyfe Co. LLC (USA)
INNOVATION IN STRUCTURAL STRENGTHENING
Latin America HQ
Fyfe Latin America (El Salvador)
Asian HQ
Fyfe Asia Pte Ltd (Singapore)
• ✓ PROFESIONAL
• ✓ COMPETENCE
• ✓ EXCELLENCE By : Arusta Irianto Salinding
02
Learn when and where it is appropriate to utilize
an FRP system for strengthening
03
KONDISI EXISTING
- Overloading/Over Capacity
- Perubahan Fungsi Struktur/Bangunan
- Pengaruh Lingkungan/Korosi
- Faktor Usia Bangunan
- Perawatan Struktur yang kurang memadai
ANALISIS STRUKTUR EXISTING
COMPOSITE
Karakter Komposit dari
TYFO® Fibrwrap® Composite Systems
AFRP
GFRP
COMPOSITE Glass-System Aramid-System Carbon-System
PROPERTY WEB SEH25-A SEH51-A UG55 WAB SAH22 SCH41 SCH11UP UC55 CFRP
Ultimate 309 521 575 896 240 696 986 1062 2790
Tensile
Strength (MPa)
Elongation at 1.6 2.0 2.2 2.2 1.2 1.7 1.0 1.05 1.8
Break (%)
Tensile 19.3 26.1 26.1 41.4 20 40 95.8 102 210
Modulus (GPa)
13
PENGARUH TERHADAP SUHU TINGGI
15
SIFAT MEKANIK
PERILAKU FRP
16
KEAWETAN
21
KEUNTUNGAN MENGGUNAKAN
TYFO ® FIBRWRAP ® SYSTEMS
23
FLOW CHART
HOW TO USE FRP SYSTEM IN STRUCTURAL CONSTRUCTION
TYFO ® FIBRWRAP ® SYSTEMS
EVALUATION / SELECTION CRITERIA OF FRP
SYSTEM ACCORDING TO ACI-440.2R-2008
1. Physical 2. Environmental
Properties of Material FRP System Durability
Composite Acceptance Testing
Criteria
3. Full System
Testing
25
INTERNATIONAL CODE OF PRACTICE FOR
FRP SYSTEM
• ICC (prev. ICBO) -AC125: International Code of Council
for Concrete and Un-reinforced Masonry Strengthening
using Fibre-Reinforced Composite Materials.
• ACI – Committee Report 440.2R-17: Guide for the
Design and Construction of Externally Bonded FRP
Systems for Strengthening Concrete Structures (refer
the testing system to ICC-AC125, see chapter 16 – ACI
440.2R-page 67)
26
ICC AC125 – FRP Material Testing Criteria
1. Physical Properties of Composite
28
ICC AC125 – FRP Material Testing Criteria
2. Environmental Durability Tests – (Accelerated Aging)
Dry Heat Resistance (140 deg. F) 90% strength after 1,000 ASTM C 3045
85% strength after 3,000
*Testing of Tensile Strength, Elongation, Tensile Modulus, Shear Bond Strength and
Adhesive Lap Strength Performed after Environmental Aging.
29
ICC AC125 – FRP Material Testing Criteria
3. Full System Testing
FRP’s bonded to the surfaces of concrete or masonry may be used to enhance the
design flexural strength of sections by acting as additional tension or compression
reinforcement.
Negative Moment
Reinforcement
Positive Moment
Reinforcement
FRP Detailing
Flexural Strengthening:
• Positive Moment – Provide 0.85 of Span Length at Bottom of Beam
0.85L1 0.85L2
L1 L2
FRP Detailing
Flexural Strengthening:
• Negative Moment – Provide 0.35 of Span Length at Top of Beam
0.35L1 0.35L2
L1 L2
ILUSTRASI PEMASANGAN FRP BEAM
0.85L
200mm lap
34
PENINGKATAN KAPASITAS AXIAL
DAN DAKTILITAS KOLOM
KOLOM
LINGKARAN KOLOM PERSEGI DAN PERSEGI
PANJANG
Overlap Overlap
200mm 200mm
ILUSTRASI PEMASANGAN FRP
38
ILUSTRASI PEMASANGAN FRP
39
DOKUMENTASI PELAKSANAAN PROYEK
PERBAIKAN PERMUKAAN BETON PERSIAPAN PERMUKAAN BETON & PENGAPLIKASIAN FRP
FRP
REASSURI NG FRP
PEMASANGAN ( TIDAK ADA B UB B LE)
PEMBERSIHAN FRP
PERMUKAAN
GRINDING ROUNDING
CORNER
FRP TERPASANG
MENGUPAS SELIMUT
BETON Y ANG PRIMING &
KUAL ITASNY A BURUK REGROUTING SATURASI FRP TERPASANG FRP TERPASANG
PROJECT REFERENCE TYFO
THE MANSION,
8 RESIDENCE BUILDING GEDUNG LIPI, JAKARTA GOODRICH MANSION, JKT WISMA KALLA, MAKASSAR
KEMAYORAN
GEDUNG DE JAVASCHE BANK, PENGADILAN NEGERI MAKASSAR BANDARA INTERNASIONAL NGURAH RAI,
CLIENT KAMI
TERIMA KASIH