RECTIFIER
PREPARED BY
BY:
LEGOWO SULISTIJONO, S.ST, M.Sc
FULL-WAVE RECTIFIER DENGAN TRAFO CT
PENGUKURAN FW RECTIFIER
FW RECTIFIER DENGAN METODA BRIDGE
TYPICAL FW RECTIFIER
NILAI RATA
RATA-RATA
RATA DARI OUTPUT PENYEARAHAN
TEGANGAN GELOMBANG PENUH ADALAH NILAI YANG
DIDAPAT DARI HASIL PENGUKURAN DENGAN
MENGGUNAKAN VOLTMETER DC.
NILAI RATA-RATA DARI PENYEARAHAN GELOMBANG
PENUH (FW) SAMA DENGAN DUA KALI NILAI RATA-RATA
DARI PENYEARAHAN SETENGAH GELOMBANG (HW)(HW).
2 Vp
Vrata − rata ( FW ) = 2 × Vrata − rata ( HW ) = = 0.636 V p
π
SOAL LATIHAN FW
PENYELESAIAN :
v = Vdc + v ac
SEHINGGA NILAI RMS DARI KOMPONEN AC ADALAH :
2π 2π 2π
1 1 1
Vr ( rms ) = ∫ dθ = ∫ − dθ = ∫ − + ) dθ
2 2 2 2
v ( v V ) ( v 2vV V
2π 2π 2π
ac d
dc d
dc d
dc
0 0 0
2 2
⎛ Vp ⎞ ⎛ 2 Vp ⎞ 1 4
Vr ( rms ) = ⎜⎜ ⎟⎟ − ⎜⎜ ⎟⎟ = V p − 2 = 0.308 V p
⎝ 2⎠ ⎝ π ⎠ 2 π
FAKTOR RIPPLE UNTUK FW
Vr ( rms ) 0.308 V p
r= × 100 % = × 100 % = 48 %
Vdc 0.636 V p
COMPUTER ANALYSIS
1•
*FW RECTIFIER DENGAN BRIDGE
VIN 1 0 SIN(0 10V 100HZ)
2
D1 1 2 D1N4001
D2 3 0 D1N4001
3 D2
D3 3 1 D1N4001
3
D4 0 2 D1N4001 0•
RL 2 3 100OHM
.MODEL
MODEL D1N4001 D(Is=14
D(Is=14.11n
11n N=1
N=1.984
984 Rs=33
Rs=33.89m
89m Ikf=94
Ikf=94.81
81 Xti=3 Eg=1
Eg=1.11
11
+ Cjo=25.89p M=.44 Vj=.3245 Fc=.5 Bv=75 Ibv=10u Tt=5.7u)
.TRAN 100U 30M
.PROBE
.END
COMPUTER ANALYSIS