Anda di halaman 1dari 28

AXIAL

CATALOGUE

YOUR PARTNER FOR FAN’S &

VENTILATION
PROFESSIONAL PRODUCT

Spesifikasi dapat berubah sewaktu-waktu tanpa pemberitahuan terlebih dahulu.


Untuk info lebih jelas mohon hubungi sales & marketing Outlet CKE sebelum
melakukan transaksi.

Pusat Pengujian
Mutu Barang
KAT/JZG/CKE/AXIAL/NEW/2017/DESEMBER/21
Company Profile

PT. Industrial Multi Fan adalah perusahaan yang khusus bergerak di PT. Industrial Multi Fan is a company
bidang kipas angin industri dan blower, mulai beroperasi pada tahun 1988, which specialized in industrial fan and
dan saat ini telah menjadi salah satu perusahaan kipas angin dan blower blower, starting operation in 1988. It is one
terkemuka di Indonesia. of leading fan and blower companies in
Indonesia.
Kami menyediakan segala macam kipas angin dan blower untuk
kebutuhan di industri dan gedung. Perusahaan kami telah berkembang We provide all kind of needs of fan & blower
dengan pesat sejak didirikan, dan saat ini telah memiliki beberapa dealer for industry and building. The company has
dan cabang di beberapa kota besar di Indonesia. growth rapidly since been established, until
today has own some dealers in Jakarta and
Dengan pengalaman lebih dari 20 tahun di bidang kipas angin dan blower, branch in major cities in Indonesia.
sekarang kami telah memiliki lab pengujian kipas & blower yang sesuai
dengan persyaratan AMCA 210-99 dengan uji kapasitas kipas sampai With more than 20 years of experience in fan
dengan 150.000 CMH dan tekanan statis sampai dengan 2.000 Pa. Ini and blower, now we have own test lab for
semua kami upayakan untuk meningkatkan pelayanan kami terhadap fan & blower accordance to AMCA 210-99
pelanggan sesuai dengan misi kami, yaitu “Customer Satisfaction”. within test fan capacity 150.000 CMH and
static pressure up to 2.000 Pa. All sort of
Melalui visi dan misi PT. Industrial Multi Fan yang akan selalu effort has been done to increase our service
memberikan yang terbaik dalam kualitas produk, layanan, serta purna to our customer according to our mission of
jual. Merupakan suatu kebanggan bagi kami untuk memberikan “Customer Satisfaction”.
kontribusi yang membangun bagi perkembangan pasar di Indonesia.
Through vision and mission, PT. Industrial
Multi Fan always give the best product
quality, service, and sales. It’s been our pride
to contribute constructively for market
development in Indonesia.

AXIAL CATALOGUE | 01
Laboratory

Outlet Chamber
Inverter Fan Outlet Nozzle Inlet Nozzle Discharge
Measurement

AXIAL CATALOGUE | 02
Certificate

With more than 20 years of experience in fan


and blower, now we have own test lab for
fan & blower accordance to AMCA 210-99
within test fan capacity 150.000 CMH and
static pressure up to 2.000 Pa. All sort of
effort has been done to increase our service
to our customer according to our mission of
“Customer Satisfaction”.

AXIAL CATALOGUE | 03
Certificate

Pusat Pengujian
Mutu Barang

AXIAL CATALOGUE | 04
CKE Axial Fan Direct

Fan Characteristics

Casing made by Galvanized & Mild Steel with Powder Coating Paint. Standard
Length (SL) fans have casing which covers the overall length of the impeller and
the motor. It is available in all fan sizes.

The impeller designed for Air-Foil Impeller, made of die-cast aluminium alloy,
driven by squirrel-cage induction motors & housed in mild steel casings to give
predictable and reliable performance. The impellers are adjustable pitch design
to allow customized air volumes to meet different requirements and needs,
which permits a wide range of air volumes for their diameter and speed. The
pitch angle varies from 5° to 40°.

The motors complies with the IEC dimension and electrical standard :

• Insulation Class : F / IP55


• Rotation : 2, 4, 6, & 8 pole available depending on the model
• Smoke Exhaust Versions : Class H -400°C / 2h
• Voltage & Freq. Supply : 220V / 400V 50Hz or 400V 50Hz

Direction of Air Flow

A. Impeller Motor
B. Motor Impeller

A B

AXIAL CATALOGUE | 05
CKE Axial Fan Direct

Places of Application

1. Building
2. Factory
3. Warehouse
4. Supermarket
5. Office-Lock
6. Dwelling
7. Laboratories
8. Etc.

Dimensions

Model ΦA ΦB ΦC J G H1 H2 I K L ΦM
315 315 349 380 385 341 222 415 322 363 8 10
400 405 442 478 390 345 280 520 395 432 8 10
500 504 545 584 495 403 325 615 498 537 8 10
560 565 608 645 445 405 365 685 560 600 8 10
630 640 685 724 48 450 400 758 560 600 8 10
710 720 762 800 495 450 450 850 738 780 8 13
800 810 862 905 588 520 490 950 802 840 12 13
900 910 972 1020 552 500 550 1055 935 980 12 13
1000 1010 1065 1113 660 600 620 1075 995 1040 24 13
(Dimension in mm)

AXIAL CATALOGUE | 06
CKE Axial Fan Direct

Installation Guide

Figure 1. Duct Restriction at Fans

Ducts significantly smaller than the fan diameter creater turbulance if transitions connect directly to fan.

DON’T BETTER

An abrupt duct expansion at fan inlet Duct expansions on the inlet to axial flow
causes air separation from the duct, starves fans should be avoided where at all possible.
the impeller tips, creates turbulance, If essential the transition should have an
reduces performance and generates included angle of not more than 15°.
increased noise.

Figure 2. Turing Vanes at Sharp Bends

Fit turning vanes in elbows adjacent to axial fans.

DON’T BETTER

Eccentric flow conditions at both inlet and Square-to-round transitions and turning
outlet will result in part of the impeller being vanes in elbows assists uniform airflow, this
starved of air and the fan not operating is a compromise only and by no means
satisfactorily. ideal.

AXIAL CATALOGUE | 07
CKE Axial Fan Direct

Installation Guide

Figure 3. Obstruction at Fan Inlet

Don’t obstruct fan inlet.

DON’T BETTER

The impeller can be starved of air when the Allow the gap at least equal to one fan
inlet to the fan is obstructed. This effectively diameter between the fan intake and
increases the system resistance thereby nearby obstructions, even the fan
reducing the air flow being handled by the performance can be less than rated. Always
fan. fit an inlet cone on open intakes.

Figure 4. Obstruction at Fan Outlet

Don’t obstruct fan outlet.

DON’T BETTER

When the discharge is too close to a wall, the Allow a gap of at least one fan diameter
obstruction generates noise and increases between fan outlet and obstruction and fit a
discharge losses. diffuser on the discharge.

AXIAL CATALOGUE | 08
CKE Axial Fan Direct

Example of Installation

Fan Installation Inside Fire Risk Zone

Fan Installation Inside Fire Risk Zone

AXIAL CATALOGUE | 09
CKE Axial Fan Pulley

Axial Fan Pulley Open Type

AFP

CKE axial fan have aerofoil impellers, made of die-cast aluminium alloy, driven
by squirrel-cage induction motors and housed in mild steel or gavalnized casing
to give predictable and reliable performance. The impellers have adjustable
pitch design for customizing air volumes to meet different requirements and
needs. The pitch angle varies from 10° to 40°.

Motor

The motors complies with the IEC dimension and electrical standard.

• Insulation Class : F / IP55


• Rotation : 2, 4, 6, & 8 pole available depending on the model
• Voltage & Freq. Supply : 230V / 400V 50Hz or 400V 50Hz supply versions.

Belt Driven Axial Fans.

Belt driven axial fans are useful for


applications where the motor is required to
be outside the system air stream. These have
been specially designed for paint booth
exhaust and air ventilation applications.

Direction of Air Flow


Dimensions
A. Airflow direction, Impeller motor
(standard models).
B. Airflow direction, motor Impeller.
Model A B C D E (No.)
315 315 375 457 187.5 10
400 400 480 508 240 10
500 500 595 584 297.5 10
560 560 640 590 320 10
630 630 680 715 340 10
710 710 790 730 395 12
(Dimension in mm)

800 800 890 740 445 12


900 900 990 838 495 16
1000 1000 1100 915 550 16

AXIAL CATALOGUE | 10
CKE Axial Fan Direct & Pulley

Data Performance

Pa

31,669 10,630 82 535

AXIAL CATALOGUE | 11
CKE Axial Fan Bifurcated

Axial Fan Bifurcated

AFB

CKE axial fan have aerofoil impellers, made of die-cast aluminium alloy, driven
by squirrel-cage induction motors and housed in mild steel or gavalnized casing
to give predictable and reliable performance. The impellers have adjustable
pitch design for customizing air volumes to meet different requirements and
needs. The pitch angle varies from 10° to 40°.

Motor

The motors complies with the IEC dimension and electrical standard.

• Insulation Class : F / IP55


• Rotation : 2, 4, & 6 pole available depending on the model
• Voltage & Freq. Supply : 220V / 400V 50Hz or 400V 50Hz supply versions.

Dimensions Bifurcated Fans.

These have been specially designed to


handle corrosive fumes, hot air and gases
which would be detrimental to the life of the
motor. The fans have a split air way with a
direct drive motor isolated from the fan air
stream. The range are designed to be
installed within ducted ventilation systems
for special industrial applications such as
furnace ventilation, commercial dryer and
kitchen cooker canopy ventilation, or where
the extract of hot hases up to 150°C is
required.

Model ΦA ΦB ΦC J L I K H1 H2 Φd
D = Cylinder Diameter (Inside)
D2 = Cylinder Diameter (Outside)
F1 = The Length of the Bracket Hole
400 404 450 478 360 500 290 350 260 499 10 W1 = The Width of the Bracket Hole
D1 = Mouting Holes Diameter Distance
500 504 560 588 470 620 370 450 320 614 12 F1 = The Length of the Fan
W1 = The Width of the Fan
560 564 620 649 480 650 410 490 360 685 12 K = The Height of the Fan

630 634 690 719 530 700 460 540 400 760 12 Casing Material : Galvanized Sheet
Impeller Material : Aluminium Alloy

710 715 770 800 550 750 620 700 450 850 14
800 805 860 891 650 850 690 770 510 956 14
900 905 970 1001 750 950 750 850 570 1070 16
1000 1006 1070 1103 770 1,000 850 950 640 1192 16

AXIAL CATALOGUE | 12
CKE Axial Fan Bifurcated

Data Performance

Pa
3,000 6,300 100 400
3,500 8,000 100 500
3,200 6,200 70 170
4,500 10,500 100 700
5,000 9,500 50 180
6,200 10,100 50 200
7,500 12,500 70 205
10,200 15,000 110 250
18,400 24,400 95 300
25,200 32,400 100 350
20,900 32,000 150 430
28,000 39,600 150 430
36,000 40,000 150 520
42,000 54,000 210 520

Commercial Kitchen Industrial Kitchen

AXIAL CATALOGUE | 13
CKE Axial Fan

AFD / AFP
Model : 400

Result at Standard Air Speed = 1450 RPM

Test Method in accordance to AMCA Standard 210-07/AANSI-ASHRAE 51-07

Motor (Kw) - - - - 0,37 0,55 0,75


Angle 10˚ 15˚ 20˚ 25˚ 30˚ 35˚ 40˚

AXIAL CATALOGUE | 14
CKE Axial Fan

AFD / AFP
Model : 400

Result at Standard Air Speed = 2800 RPM

Test Method in accordance to AMCA Standard 210-07/AANSI-ASHRAE 51-07

Motor (Kw) - - - 0,75 1,1 - 2,2


Angle 10˚ 15˚ 20˚ 25˚ 30˚ 35˚ 40˚

AXIAL CATALOGUE | 15
CKE Axial Fan

AFD / AFP
Model : 500

Result at Standard Air Speed = 1450 RPM

Test Method in accordance to AMCA Standard 210-07/AANSI-ASHRAE 51-07

Motor (Kw) - - - 0,75 - 1,5 2,2


Angle 10˚ 15˚ 20˚ 25˚ 30˚ 35˚ 40˚

AXIAL CATALOGUE | 16
CKE Axial Fan

AFD / AFP
Model : 500

Result at Standard Air Speed = 2800 RPM

Test Method in accordance to AMCA Standard 210-07/AANSI-ASHRAE 51-07

Motor (Kw) 1,5 2,2 3 4 - - -


Angle 10˚ 15˚ 20˚ 25˚ 30˚ 35˚ 40˚

AXIAL CATALOGUE | 17
CKE Axial Fan

AFD / AFP
Model : 560

Result at Standard Air Speed = 1450 RPM

Test Method in accordance to AMCA Standard 210-07/AANSI-ASHRAE 51-07

Motor (Kw) - 0,37 0,55 - 1,1 - -


Angle 10˚ 15˚ 20˚ 25˚ 30˚ 35˚ 40˚

AXIAL CATALOGUE | 18
CKE Axial Fan

AFD / AFP
Model : 560

Result at Standard Air Speed = 2800 RPM

Test Method in accordance to AMCA Standard 210-07/AANSI-ASHRAE 51-07

Motor (Kw) - 2,2 3 4 - - -


Angle 10˚ 15˚ 20˚ 25˚ 30˚ 35˚ 40˚

AXIAL CATALOGUE | 19
CKE Axial Fan

AFD / AFP
Model : 630

Result at Standard Air Speed = 1450 RPM

Test Method in accordance to AMCA Standard 210-07/AANSI-ASHRAE 51-07

Motor (Kw) - - - 1,1 1,5 2,2 -


Angle 10˚ 15˚ 20˚ 25˚ 30˚ 35˚ 40˚

AXIAL CATALOGUE | 20
CKE Axial Fan

AFD / AFP
Model : 710

Result at Standard Air Speed = 1450 RPM

Test Method in accordance to AMCA Standard 210-07/AANSI-ASHRAE 51-07

Motor (Kw) - - - 2,2 3 - 5,5


Angle 10˚ 15˚ 20˚ 25˚ 30˚ 35˚ 40˚

AXIAL CATALOGUE | 21
CKE Axial Fan

AFD / AFP
Model : 800

Result at Standard Air Speed = 1450 RPM

9.00 10.00

8.00

0.00
9.00 10.00

Test Method in accordance to AMCA Standard 210-07/AANSI-ASHRAE 51-07

Motor (Kw) - - 3 4 5,5 - -


Angle 10˚ 15˚ 20˚ 25˚ 30˚ 35˚ 40˚

AXIAL CATALOGUE | 22
CKE Axial Fan

AFD / AFP
Model : 900

Result at Standard Air Speed = 1450 RPM

Test Method in accordance to AMCA Standard 210-07/AANSI-ASHRAE 51-07

Motor (Kw) - 7,5 11 15 - - -


Angle 10˚ 15˚ 20˚ 25˚ 30˚ 35˚ 40˚

AXIAL CATALOGUE | 23
CKE Axial Fan

AFD / AFP
Model : 1000

Result at Standard Air Speed = 1450 RPM

Test Method in accordance to AMCA Standard 210-07/AANSI-ASHRAE 51-07

Motor (Kw) 7,5 11 15 18,5 - - -


Angle 10˚ 15˚ 20˚ 25˚ 30˚ 35˚ 40˚

AXIAL CATALOGUE | 24
Axial Blade

7 / Φ350 12 / Φ280

8 / Φ150 14 / Φ350

9 / Φ200 18 / Φ500

10 / Φ150

AXIAL CATALOGUE | 25
SPECIALIZED IN BUILDING & INDUSTRIAL VENTILATION.