Anda di halaman 1dari 12

Nama : Prajid Egif Auzan

NIM : D1121181023
Matkul : Perancagan Alat Proses

Data
Umpan
Komponen BM Titik Didih Kg/J
g/mol K C
H2O 18.015 373.15 100 371.2288
C6H5OH (hk) 94.113 454.99 181.84 2176.0189
C8H14O2 (lk) 142.198 434 160.85 6578.2761
Total 9125.5238

Konstanta Antoine
Komponen A B C D
H2O 29.8605 -3152.2 -7.3037 2.4247E-09
C6H5OH (hk) 23.5332 -3496.1 -4.899 0.0001216
C8H14O2 (lk) 5.9469 -3021.2 3.259 -0.01419

Penentuan Lk & Hk
Komponen Persentase
Lk = n Butil Meta Krilat 0.99
Hk = Fenol 0.01

Menentukan pers Antoine : Log P = A + B/T + CLogT + DT + ET^2

Neraca Massa (Hasil)


Total : F=Destilat +Bottom
Komponen : z.F = y.D + xB
Umpan : z = yi/ki
ki = Po/P
Trial Σyi=1 (Σki*xi) "Berdasarkan data kondisi umpan dalam keadaan cair jenuh (Bubble Point)"
Tekanan (atm) 1.07 mmhg 813.2
Temperatur ( C ) 126.03 K 412.3371 T Trial

Komponen Flow rate


zi Po (mmHg)
Kg/J Kmol/J
H2O 371.2288 20.6238 0.2140388603 2644.4517
C6H5OH (hk) 2176.0189 29.4057 0.3051795748 196.0995
C8H14O2 (lk) 6578.2761 46.3259 0.4807815649 389.7271
Total 9125.5238 96.3554 1 3230.2784

Hasil yang diinginkan


Komponen Distilate
Kg/Jam Kmol/Jam xdi Po
H2O 371.537757 20.6238 0.3088296826 9.2296851772359
C6H5OH (hk) 27.674586441 0.294057 0.0044033364 0.1619398585892
C8H14O2 (lk) 6521.575824918 45.862641 0.686766981 0.7308348232556
Total 6920.788168359 66.780498 1 10.122459859081
Ttrial 10.0363891092125 C 283.18638911 K
P 1 atm

Komponen Bottom
kg/jam kmol/jam yi Po
H2O 0.0000 0.0000 0.0000 0
C6H5OH (hk) 2739.7841 29.1116 0.9843 1.0834832003605
C8H14O2 (lk) 65.8745 0.4633 0.0157 4.0554249422037
Total 2805.6586 29.5749 1.0000 5.1389081425642
Ttrial 35.0681229545955 C 308.21812295 K
P 1.13 atm

C. Penentuan dan Pengecekan Lk dan Hk


dipakai persamaan Shiras et.al
x id  i  1 x lk,d D  lk   i x hk,d D
 
z if  lk  1 z lk,d F  lk  1 z hk ,d F

Komponen α Xid/Zir Keterangan


H2O 13.4858 12.401599435 Keatas
C6H5OH (hk) 1.0000 0.01 Terdistribusi
C8H14O2 (lk) 1.9874 0.99 Terdistribusi
5.4911
Kesimpulan: Pemilihan LK, HK, dan derajat pemisahan sudah benar & asumsi benar

Penentuan komponen non key


non key adalah air. Air disini semuanya teruapkan sehingga tidak adanya terdistribusi.

Menentukan refluks minimum dan jumlah plate minimum


Menghitung Teta

Trial Teta 10.9478498324256


Komponen zif α mean 1-q xi,d
H2O 0.2140 13.4858 1.1373 0.3088
C6H5OH (hk) 0.3052 1.0000 -0.0307 0.0044
C8H14O2 (lk) 0.4808 1.9874 -0.1066 0.6868
Total 1.0000 1.0000 1.0000
Penentuan Refluks Minimum
Refluks minimum :
digunakan persamaan Colburn dan Underwood Rm+1
Rm
 i x id Rm/(Rm+1) =
 i  
 Rm 1
Refluks yang digunakan berkisar antara (
dimana : Diambil refluks rasio = 1.5 sehingga
α = relative volatility komponen i R: 1,2 Rmin
Rm = minimum refluks ratio R=
xi,d = konsentrasi komponen i pada puncak saat Rm Jumlah Refluks sebesar 0,5859
ө = akar dari persamaan:
Menghitung teta (Coulson, pers.11.61,Underwood equation)

 i z if
  1 q
i  

Dengan :
zif = konsentrasi komponen i di umpan.
q = thermal characteristic umpan, untuk cair jenuh q = 1
Perhitungan Stage Minimum (Nmin)
Stage minimum dapat dihitung dengan menggunakan persamaan fenske

 x LK   x HK  
log 
 
   
 
 x HK  d  x LK
 
b 
Nm 
log  LK
Dengan :
alk = volatilitas relatif rata-rata komponen LK = 4.10998
Diperoleh :
Jumlah Stage Minimum = 6.5021
= 7
Dari Coulson fig. 11-11 p. 419 (Erbar-Maddox Correlation) diperoleh :
Nm/N = 0.25 R/(R+1):
N= 28 stage
Jadi, Pada keadaan nilai Refluks 0,5859 jumlah plate yang dibutuhkan
Temperatur rata - rata kolom menara
Rumus : xb.Tb +xd.Td + xf.Tf
Total Mol : 192.7108 kmol/jam
xi T ( °C )
xi,b 0.1535 35.0681
xi,d 0.3465 10.0364
xi,f 0.5 139.1871
T rata-rata = 61.4305 °C
= 334.5805 K

Menentukan refluks minimum dan jumlah plate minimum


Digunakan Kirkible Equation

Nr ln [(D/F)lk / (D/F)hk]
Ns ln [(B/F)lk / (B/F)hk]

Nr 4.59511985013459
NS -4.5951

Nr/Ns -1
Kmol/J F mol

20.6238 0.2140
29.4057 0.3052
46.3259 0.4808
96.3554 1

E
1.809E-06
9.6537E-13
7.6392E-06

(Bubble Point)"
139.1871 C

Ki = Po/Pt y=zi*Ki α = Ki/Kheavykey

3.2519 0.6960 13.4853


0.2411 0.0736 1.0000
0.4793 0.2304 1.9874
3.9723 1.0000 16.4726

α = Ki/Kheavykey
Ki: Po/Pt x: xdi/Ki
9.2296851772 0.0334604785 56.9945
0.1619398586 0.0271911836 1.0000
0.7308348233 0.9397020491 4.5130
10.122459859 1.0003537113 62.5075
Dirancang : MD menggunakan kondenser total, dimana uap keluar top menara diembun-
kan seluruhnya. Sebagian diambil sebagai distilat dan sebagian dikembalikan
ke menara sebagai refluks. Cairan distilat berada pada kondisi cair jenuh.

α = Ki/Kheavykey
Ki: Po/Pt y : yi*Ki
0 0 0.0000
0.9588346906 0.9438155774 1.0000
3.5888716303 0.0562158104 3.7430
4.5477063209 1.0000313878 4.7430
Dirancang : MD menggunakan reboiler parsial, dimana cairan keluar bottom menara
diuapkan sebagian. Uap dikembalikan ke menara sebagai boil-up dan cairan di-
ambil sebagai bottom product. Bottom product berada pada kondisi cair jenuh.

Jika:
x id < -0.01 → komponen i tidak terdistribusi
z if (ada di hasil bawah semua)

x id
> 0.01 → komponen i tidak terdistribusi
z if
(ada di hasil atas semua)

0.01 < x id < 0.99 → komponen i terdistribusi di hasil atas


z if
dan hasil bawah
asumsi benar
Rmin+1 α destilate α Bottom α avg
1.6410 56.9945 0.0000 0
-0.0004 1.0000 1.0000 1
-0.1523 4.5130 3.7430 4.109981
1.4883 62.5075 4.7430 17.21831

1.4883
0.4883
0.3280748752

ang digunakan berkisar antara (1.2 - 1.5) Rm.


efluks rasio = 1.5 sehingga
dikarenakan mengefesiensi energi dan tidak plate tidak terlalu banyak digunakan dari perhitungan, sehingga
0.5859132748
fluks sebesar 0,5859

plate Dibulatkan menjadi 7 plate dikarenakan lebih dari 6


0.3694484964 Diplotkan grafik R/(R+1) terhadap Nm/N

umlah plate yang dibutuhkan yaitu 28 stage

Penentuan Efesiensi Menara


Dihitung dengan persamaan empiris O'Connel:
Eo : 51 - 32,5 log (μ avg . α avg)
Eo: 60.323868289 %
Sehingga jumlah real plate adalah: N/Eo
N real : 46.4161215 plate
n dari perhitungan, sehingga

Anda mungkin juga menyukai