MENARA DISTILASI
Fungsi : Memisahkan Tetrahydrofuran (C4H8O) dari air (H2O) dan 1,4
Butanediol (C4H10O2) dengan kemurnian 99%
Jenis : Sieve Tray Distillation Tower
MASUK
BM
Komponen Arus 6
(Kg/kmol)
komposisi kmol/jam Kg/jam
BD 90,12 0,0099 1,0612 95,6393
H2O 18 0,2058 110,4301 1987,7425
THF 72,11 0,7843 105,0632 7576,1054
total 1 9659,4872
KELUAR
BM
Komponen Arus 7 (Produk/Distilat) Arus 8 (UPL/Residu)
(Kg/kmol)
komposisi kmol/jam kg/jam komposisi kmol/jam kg/jam
BD 90,12 0 0 0 0,0459 1,0612 95,6393
H2O 18 0,01 4,2089 75,7611 0,9177 106,2212 1911,9814
THF 72,11 0,99 104 7500,3444 0,0364 1,0506 75,7611
subtotal 1 7576,1054 1 2083,3818
1
Lampiran Menara Distilasi
2
Lampiran Menara Distilasi
Komponen Laju (kmol/jam) Fraksi mol (x) P° (mmHg) K= P°/P y =K*x αj = Ki/KHK
BD 1,0612 0,0049 8,7049,E-01 0,0011 0,0000 0,0024
H2O 110,4301 0,5099 3,6162,E+02 0,4758 0,2426 1,0000
THF 105,0632 0,4852 1,1873,E+03 1,5622 0,7579 3,2833
Jumlah 216,5546 1,0000 1,0006
3
Lampiran Menara Distilasi
Tabel Hasil iterasi kondisi atas pada 1 atm 67,03 oC untuk distilat keluar kondesor
αj =
Komponen Laju (kmol/jam) Fraksi mol ( x) P° (mmHg) K= P°/P y=k*x
Ki/KHK
BD 0,0000 0,0000 0,3402 0,0004 0,0000 0,0017
H2O 4,2089 0,0389 204,1792 0,2687 0,0104 1,0000
THF 104,0125 0,9611 783,3239 1,0307 0,9906 3,8365
Jumlah 108,2215 1,0000 1,0011
4
Lampiran Menara Distilasi
Dengan hubungan :
D : Laju alir mol pada hasil atas
F : Laju alir mol pada umpan
𝑥𝑗𝐷 : Fraksi mol komponen j pada hasil atas
Syarat :
𝑥𝑗𝐷 𝐷
a. −0,01 ≤ ≤ 1,01 maka komponen j tersebut terdistribusi sebagai hasil atas dan hasil
𝑥𝑗𝐹 𝐹
bawah
𝑥𝑗𝐷 𝐷
b. > 1,01 maka komponen j tersebut hanya terdistribusi sebagai hasil atas
𝑥𝑗𝐹 𝐹
𝑥𝑗𝐷 𝐷
c. < −0,01 maka komponen j tersebut hanya terdistribusi sebagai hasil bawah
𝑥𝑗𝐹 𝐹
5
Lampiran Menara Distilasi
= √3,7370 × 2,6833
= 3,1666
Persamaan Fenske :
𝑥 𝑥
log [𝑥 𝐿𝑘 ] 𝐷 [ 𝑥𝐻𝑘 ] 𝐵
𝐻𝑘 𝐿𝑘
𝑁𝑚𝑖𝑛 + 1 =
log 𝛼𝑎𝑣𝑔,𝐿𝐾
0,9611 0,9805
log [0,0389] [0,0097]
𝑁𝑚𝑖𝑛 + 1 =
log 3,1666
𝑁𝑚𝑖𝑛 + 1 = 6,7872
𝑁𝑚𝑖𝑛 = 5,7872
Jadi jumlah plate minimum adalah 5,7872 ≈ 6
6
Lampiran Menara Distilasi
7
Lampiran Menara Distilasi
Dengan :
𝑅𝑜𝑝 : Refluks rasio optimum
8
Lampiran Menara Distilasi
Diperoleh :
𝑁𝑖𝑑𝑒𝑎𝑙 = 16,5
Sehingga didapat jumlah plate ideal (N) = 16,5
Menentukan effisiensi plate
Didekati dengan cara O’Connel menggunakan persamaan 11.67 Pada Towler, G., Ray Sinnot,
Chemical Engineering Design, Elsevier, San Diego, (2008), halaman 701
𝐸𝑜 = 51 − 32,5 log(𝜇𝑎 . 𝛼𝑎 )
Keterangan :
Eo = Effisiensi plate (%)
αa = volatilitas realtif komponen LK dalam umpan (mNs/m2)
µa = viskositas rerata dalam umpan
Data viskositas rerata pada umpan menara :
αa = 3,1666
µa = 3,343E-01
Sehingga ,
𝐸𝑜 = 51 − 32,5 log(3,343𝐸 − 01 × 3,1666)
𝐸𝑜 = 50,19%
Menentukan jumlah plate aktual (𝑁𝑎𝑘𝑡𝑢𝑎𝑙 )
𝑁𝑖𝑑𝑒𝑎𝑙
𝑁𝑎𝑘𝑡𝑢𝑎𝑙 =
𝑒𝑓𝑓
Keterangan :
eff = Effisiensi plate (%)
16,5
𝑁𝑎𝑘𝑡𝑢𝑎𝑙 = = 32,87 = 33
50,19%
𝑁𝑎𝑘𝑡𝑢𝑎𝑙 dalam menara = 𝑁𝑎𝑘𝑡𝑢𝑎𝑙 − 1 (𝑅𝑒𝑏𝑜𝑖𝑙𝑒𝑟) = 32
9
Lampiran Menara Distilasi
Dimana :
B = Kecepatan mol bottom (kgmol/jam)
D = Kecepatan mol distilat (kgmol/jam)
Nr = Jumlah plate pada seksi rectifying
Ns = Jumlah plate pada seksi stripping
b = Bottom
d = Distilat
f = Feed
HK = Heavy Key
LK = Light Key
Nr = 0,5702 Ns
Nr + Ns = 32
0,5702 Ns + Ns = 32
Ns = 20,2974 ≈ 20
Nr = 12
Maka diperoleh jumlah plate teoritis :
seksi rectifying = 20
seksi stripping = 12
10
Lampiran Menara Distilasi
Neraca massa :
V1 = L0 + D
V2 = L1 + D
V3 = L2 + D
Vn = Ln-1 + D
Vn+1 = Ln + D
Untuk aliran konstan molal :
V1 = V2 = V3 = Vn+1 = V
L0 = L1 = L2 = L3 = Ln = L
Neraca komponen pada puncak menara :
V . y1,i = L . x0,i + D. xd,i
Keterangan :
V = Kecepatan mol uap (kmol/jam)
L = Kecepatan mol cairan (kmol/jam)
D = Kecepatan mol distilat (kmol/jam)
y1,i = Fraksi mol komponen i pada uap
x0,i = Fraksi mol komponen i pada cairan refluks
11
Lampiran Menara Distilasi
Vi = yi V BM
Komponen yi kg/jam fraksi massa
(kmol/jam) (kg/kmol)
BD 0,0000 0,0000 90,1200 0,0000 0,0000
H2O 0,0389 7,1137 18,0000 128,0462 0,0100
THF 0,9611 175,7949 72,1100 12676,5729 0,9900
Jumlah 1,0000 182,9086 12804,6191 1,0000
Komposisi cair
Dihitung menggunakan persamaan :
Li = Vi - Di
Dimana :
Li : kecepatan mol masing masing komponen cair (kmol/jam)
12
Lampiran Menara Distilasi
Vi Li
Komponen Di (kmol/jam) Li (kg/jam) fraksi mol fraksi massa
(kmol/jam) (kmol/jam)
BD 0,0000 0,0000 0,0000 0,0000 0,0000 0,0000
H2O 7,1137 4,2089 2,9047 52,2851 0,0389 0,0100
THF 175,7949 104,0125 71,7824 5176,2286 0,9611 0,9900
Jumlah 182,9086 108,2215 74,6871 5228,5137 1,0000 1,0000
13
Lampiran Menara Distilasi
𝜎 = ∑ 𝑥𝑚𝑎𝑠𝑠 𝑖 . 𝜎𝑖
Dimana :
𝜎 : tegangan muka (dyne/cm)
xmassi : fraksi massa masing-masing komponen cair
τi : tegangan muka masing-masing komponen cair (dyne/cm)
Dimana 𝜎 dihitung dengan persamaan sudgen :
Keterangan :
σ :Tegangan permukaan (dyne/cm)
Pch : Sudgen’s parachor
ρl : Densitas cairan (kg/m3)
ρv : Densitas uap (kg/m3)
M : Berat molekul (kg/kmol)
14
Lampiran Menara Distilasi
Atom, group or
Konribusi
bond
C 4,8
H 17,1
H dalam OH 11,3
O 20
N 12,5
Cl 54,3
Sigle bond 0
Double bond 23,2
6-membered ring 6,1
Untuk menentukan tegangan muka pada puncak menara digunakan data pada Li
xσ
Komponen Fraksi massa (x) BM (kg/kmol) Pch σ (dyne/cm)
(dyne/cm)
BD 0,0000 90,1200 218,6 16,6236 0,0000
H2O 0,0100 18,0000 54,2 39,4745 0,3947
THF 0,9900 72,1100 176,0 17,0403 16,8699
Jumlah 1,0000 17,2647
𝐿𝑤 𝜌𝑔
𝐹𝐿𝑉 = √
𝑉𝑤 𝜌𝑙
Dimana :
FLV : parameter flooding
LW : kecepatan massa fase cair (kg/jam)
VW : kecepatan massa fase uap (kg/jam)
ρg : rapat massa fase uap (kg/m3)
ρl : rapat massa fase cair (kg/m3)
15
Lampiran Menara Distilasi
5228,5137 2,4930
𝐹𝐿𝑉 = 12804,6191 √834,9319 = 0,0223
uf = 1,1533 m/s
16
Lampiran Menara Distilasi
Luasan yang ditempati oleh downcomer berkisar antara 10 % sampai 20% dari luas menara.
Dirancang :
Downcomer menempati 20% dari luas total.
17
Lampiran Menara Distilasi
Diameter Menara
4. At 4 (1,9329 m2 )
Dt = √ =√ = 1,5692 m
π 3,14
b. Dasar menara
Sketsa permasalahan :
18
Lampiran Menara Distilasi
19
Lampiran Menara Distilasi
Vi Bi Li BM Li fraksi Fraksi
Komponen
(kmol/jam) (kmol/jam) (kmol/jam) (kg/kmol) (kg/jam) mol massa
BD 1,7918 1,0612 2,8530 90,1200 257,1159 0,0098 0,0459
H2O 179,3429 106,2212 285,5641 18,0000 5140,1544 0,9805 0,9177
THF 1,7739 1,0506 2,8245 72,1100 203,6754 0,0097 0,0364
Jumlah 182,9086 108,3331 291,2417 5600,9457 1,0000 1,0000
20
Lampiran Menara Distilasi
Dimana :
ρg : rapat massa uap (kg/m3)
BMcamp : berat molekul uap (kg/kmol)
PT : tekanan total (atm)
Rg : konstanta gas ideal = 0,0821 m3.atm/kmol.K
T : suhu operasi (K)
kg
19,2313 𝑥 1 𝑎𝑡𝑚 𝑘𝑔 𝑙𝑏
ρg = 𝑘𝑚𝑜𝑙 = 0,5868 = 0,0366
m3 𝑎𝑡𝑚 𝑚3 𝑓𝑡 3
0,0821 𝑥 399,4456 𝐾
𝑘𝑚𝑜𝑙 𝐾
5600,9457 kg/jam 𝑘𝑔 𝑘𝑔 𝑙𝑏
ρl = = 0,9481 = 948,0609 3 = 59,1855 3
5907,7912 L/jam 𝐿 𝑚 𝑓𝑡
Q = 5853,4380 L/jam = 0,0016 m3/s
Tegangan muka
𝜎 = ∑ 𝑥𝑚𝑎𝑠𝑠 𝑖 . 𝜎𝑖
Dimana :
𝜎 : tegangan muka (dyne/cm)
xmassi : fraksi massa masing-masing komponen cair
τi : tegangan muka masing-masing komponen cair (dyne/cm)
21
Lampiran Menara Distilasi
Keterangan :
σ :Tegangan permukaan (dyne/cm)
Pch : Sudgen’s parachor
ρl : Densitas cairan (kg/m3)
ρv : Densitas uap (kg/m3)
M : Berat molekul (kg/kmol)
Data untuk menentukan Pch (coulson,1983)
Atom, group or
Konribusi
bond
C 4,8
H 17,1
H dalam OH 11,3
O 20
N 12,5
Cl 54,3
Sigle bond 0
Double bond 23,2
6-membered ring 6,1
Untuk menentukan tegangan muka pada puncak menara digunakan data pada Li
xσ
Komponen Fraksi massa (x) BM (kg/kmol) Pch σ (dyne/cm)
(dyne/cm)
BD 0,0459 90,1200 218,6000 27,8988 1,2807
H2O 0,9177 18,0000 54,2000 66,2486 60,7983
THF 0,0364 72,1100 176,0000 28,5982 1,0400
Tegangan muka 1,0000 = 1,0400 dyne/cm
𝐿𝑤 𝜌𝑔
𝐹𝐿𝑉 = √
𝑉𝑤 𝜌𝑙
Dimana :
FLV : parameter flooding
LW : kecepatan massa fase cair (kg/jam)
VW : kecepatan massa fase uap (kg/jam)
ρg : rapat massa fase uap (kg/m3)
ρl : rapat massa fase cair (kg/m3)
5600,9457 0,5868
𝐹𝐿𝑉 = 3517,5639 √948,0609 = 0,0396
23
Lampiran Menara Distilasi
uf = 1,4460 m/s
Luasan yang ditempati oleh downcomer berkisar antara 10 % sampai 20% dari luas menara.
24
Lampiran Menara Distilasi
Dirancang :
Downcomer menempati 20% dari luas total.
Diameter Menara
4. At 4 (1,7994 m2 )
Dt = √ = √ = 1,5140 m
π 3,14
25
Lampiran Menara Distilasi
= 0,1833 in
5
Dipakai tebal standar untuk shell (ts) = 16 𝑖𝑛 = 0,3125 in = 0,0079 m
26
Lampiran Menara Distilasi
icr = 4 3/4 in
rc = 78 in
0,885×17,6351 ×78
t head = 11700× + 0,125
0,8 − 0,1 × 17,6351
= 0,255 in
1
Dipakai tebal standar untuk head (th) = 4 𝑖𝑛 = 0,25 in
Dari tabel 5.6 Brownell-Young hal. 88, straight flange antara 1,5 – 2,5 in. Dipilih straight
flange (Sf) = 2 in.
27
Lampiran Menara Distilasi
keterangan :
t : Head thickness, inches
icr : Inside-Corner Radius, inches
sf : Straight Flange, inches
r : Radius Of Dish, inches
OD : Outside Diameter, inches
ID : Inside Diameter, inches
b : Depth Of Dish (Inside), inches
a : Inside Radius, inches
OA : Overall dimension, inches
𝐼𝐷 77,375
𝑎 = = = 38,6875 𝑖𝑛
2 2
AB = a – icr = 38,6875 – 4 3/4 = 33,9375 in
BC = r – icr = 78 – 4 3/4= 73.25 in
AC = √𝐵𝐶 2 − 𝐴𝐵 2
= √73,252 − 33,93752
= 64,9139 in
b = r – AC
= 78 – 64,9139 in
= 13,0861 in
OA = b + sf + th
= (13,0861 + 2 + 1/4) in
= 15,3986 in
Sehingga diperoleh : tinggi head = 15,3986 in = 0,3911 m
28
Lampiran Menara Distilasi
Nilai QL yang digunakan untuk menentukan flow pattern adalah QL top karena QL top > QL
bottom column.
Berdasarkan figure 17.35 halaman 868, Towler, G,, Ray Sinnott, 2008, Chemical Engineering
Design, Elsevier, San Diego, maka jenis flow pattern yang dipilih adalah revers flow.
Properti plate :
Column Diameter (Dc) = 1,9653 m
Ac : Column area (m2)
Ad : Downcomer Area
: 10-20% Ac
An : Net Area available for vapor-liquid disagement
Aa : Active or bubbling area
Ah : Hole area
Ap : Perforated area (including blanked areas)
Aap : The clearence area under the downcomer apron
hw : Weir height (mm)
: 6-12 mm untuk operasi vakum
: 40-90 untuk operasi pada tekanan diatas atmosferik
dh : Hole diameter (mm)
: 2,5-19 mm
Tebal tray : 5 mm for carbon steel
: 3 mm for stainless steel
lp : Pitch (Distance between the hole centers)
: 2,5-4,0 dh
(Towler and Sinnott, “Chemical Engineering Design Principles”, Mc Graw Hill, New York 2008,
hal. 726-727).
Dimana :
Ac = 3,14 x (Dc2)/4 = 3,0321 m2
Ad = 20% x 3,0321 m2 = 0,6064 m2
29
Lampiran Menara Distilasi
1. Seksi Enriching
Trial Ah
Ah = 2,5% x Aa
= 2,5% x 1,8192 m2 = 0,0455 m2
Menentukan panjang weir (lw)
Ad 0,6064
= = 20%
Ac 3,0321
Dipilih :
hw = 40 mm
dh = 4,16 mm
lp = 4x dh = 16,64 mm
Tebal tray = 5 mm
Cek Weeping
Lw max : Maximum liquid rate
Lw max = 5228,5137 kg/jam = 1,4524 kg/s
Lw min : Minimum liquid rate
= 0,8 x Lw Max = 0,8 x 1,4524 kg/s = 1,1619 kg/s
ρL = 834,9319 kg/m3
lw = 1,7122 m
hw = 40 mm
2
𝐿𝑤 3
ℎ𝑜𝑤 = 0,750 ( )
𝜌𝑙 . 𝑙𝑤
2
1,4524 3
ℎ𝑜𝑤 𝑚𝑎𝑥 = 0,750 ( ) = 7,5795 𝑚𝑚
834,9319 × 1,7122
30
Lampiran Menara Distilasi
2
1,1619 3
ℎ𝑜𝑤 𝑚𝑖𝑛 = 0,750 ( ) = 6,5319 𝑚𝑚
834,9319 × 1,7122
Pada kecepatan minimum :
ℎ𝑤 + ℎ𝑜𝑤 = (40 + 6,5319 ) 𝑚𝑚 = 46,5319 𝑚𝑚
Berdasarkan fig.11.32 page 724, Towler, G,, Ray Sinnott, 2008, Chemical Engineering Design,
Elsevier, San Diego diatas, diperoleh K2 sebesar 29,9
Dari persamaan 11.84 (Towler, G,, Ray Sinnott, 2008)
𝐾2 − 0,9(25,4 − 𝑑ℎ )
𝑈ℎ 𝑚𝑖𝑛 =
𝜌𝑣 0,5
31
Lampiran Menara Distilasi
Karena Aktual minimum vapor velocity > Uh min, maka tidak terjadi weeping
2. Seksi Stripping
Trial Ah
Ah = 4% x Aa
= 4% x 1,8192 m2 = 0,0728 m2
Menentukan panjang weir (lw)
Ad 0,6064
= = 20%
Ac 3,0321
Dipilih :
hw = 40 mm
dh = 5 mm
lp = 4 x dh = 20 mm
Tebal tray = 5 mm
Cek Weeping
Lw max : Maximum liquid rate
Lw max = 5600,9457 kg/jam = 1,5558 kg/s
Lw min : Minimum liquid rate
= 0,8 x Lw Max = 0,8 x 1,5558 kg/s = 1,2447 kg/s
ρL = 948,0609 kg/m3
lw = 1,7122 m
hw = 40 mm
2
𝐿𝑤 3
ℎ𝑜𝑤 = 0,750 ( )
𝜌𝑙 . 𝑙𝑤
2
1,5558 3
ℎ𝑜𝑤 𝑚𝑎𝑥 = 0,750 ( ) = 7,2908 𝑚𝑚
948,0609 × 1,7122
2
1,2447 3
ℎ𝑜𝑤 𝑚𝑖𝑛 = 0,750 ( ) = 6,2830 𝑚𝑚
948,0609 × 1,7122
Pada kecepatan minimum :
ℎ𝑤 + ℎ𝑜𝑤 = (40 + 6,2830 ) 𝑚𝑚 = 46,2830 𝑚𝑚
32
Lampiran Menara Distilasi
Berdasarkan fig.11.32 page 724, Towler, G,, Ray Sinnott, 2008, Chemical Engineering Design,
Elsevier, San Diego diatas, diperoleh K2 sebesar 29,8
Dari persamaan 11.84 (Towler, G,, Ray Sinnott, 2008)
𝐾2 − 0,9(25,4 − 𝑑ℎ )
𝑈ℎ 𝑚𝑖𝑛 =
𝜌𝑣 0,5
29,8 − 0,9(25,4 − 5)
𝑈ℎ 𝑚𝑖𝑛 = = 14,9345 𝑚/𝑠
(0,5868)0,5
33
Lampiran Menara Distilasi
34
Lampiran Menara Distilasi
Dimana :
Qv : Kecepatan volume uap (m3/s)
Ah : Hole area (m2)
Qv = 1,4268 m3/s
Ah = 0,0455 m2
1,4268 m3 /s
uh = = 31,3603 𝑚/𝑠
0,0455 𝑚2
Menentukan koeffisien perforated (Co)
Digunakan fig. 11.36 Towler dan Sinnott, hal. 729.
2
𝐴ℎ 𝑑ℎ 0,00416 𝑚 2
= 0,9 ( ) = 0,9 ( ) = 5,63%
𝐴𝑝 𝑙𝑝 0,0166
𝑇𝑒𝑏𝑎𝑙 𝑝𝑙𝑎𝑡𝑒 5 𝑚𝑚
= = 1,2
Diameter lubang 4,16 mm
35
Lampiran Menara Distilasi
hw = 40 𝑚𝑚 𝑙𝑖𝑞𝑢𝑖𝑑
4. Weir liquid Crest how
2
𝐿 3
ℎ𝑜𝑤 = 0,750 ( )
𝜌𝑙 . 𝑙𝑤
Dimana :
how : tinggi cairan diatas weir (m)
L : kecepatan massa cairan (kg/s)
ρl : rapat massa cairan (kg/m3)
lw : panjang weir (m)
2
1,4524 𝑘𝑔/𝑠 3
ℎ𝑜𝑤 = 0,750 ( 3
) = 7,5795 𝑚𝑚 𝑙𝑖𝑞𝑢𝑖𝑑
834,9319 𝑘𝑔/𝑚 × 1,7122 𝑚
Persamaan 11.87 (Towler, G,, Ray Sinnott, 2008, Chemical Engineering Design, Elsevier,
San Diego, hal. 728)
Dimana :
36
Lampiran Menara Distilasi
b. Seksi Stripping
2
𝐴ℎ 𝑑ℎ 5 𝑚𝑚 2
= 0,9 ( ) = 0,9 ( ) = 5,63%
𝐴𝑝 𝑙𝑝 20 𝑚𝑚
𝑇𝑒𝑏𝑎𝑙 𝑝𝑙𝑎𝑡𝑒 5 𝑚𝑚
= =1
Diameter lubang 5 mm
37
Lampiran Menara Distilasi
hw = 40 𝑚𝑚 𝑙𝑖𝑞𝑢𝑖𝑑
4. Weir liquid Crest how
2
𝐿 3
ℎ𝑜𝑤 = 0,750 ( )
𝜌𝑙 . 𝑙𝑤
38
Lampiran Menara Distilasi
Dimana :
how : tinggi cairan diatas weir (m)
L : kecepatan massa cairan (kg/s)
ρl : rapat massa cairan (kg/m3)
lw : panjang weir (m)
2
1,5558 𝑘𝑔/𝑠 3
ℎ𝑜𝑤 = 0,750 ( ) = 7,2908 𝑚𝑚 𝑙𝑖𝑞𝑢𝑖𝑑
948,0609 𝑘𝑔/𝑚3 × 1,7122 𝑚
Persamaan 11.87 (Towler, G,, Ray Sinnott, 2008, Chemical Engineering Design, Elsevier,
San Diego, hal. 728)
Dimana :
Stripping (ΔPs) = 0,0080 𝑎𝑡𝑚 per tray = 6,0553 mmHg per tray
Rectifying (ΔPr) = 0,0217 𝑎𝑡𝑚 per tray = 16,5065 mmHg per tray
Batas Pressure drop per tray yang diizinkan = 4,1 s.d. 6,2 mmHg (Henry Kister, Distillation Design
hal 350).
Berdasarkan hasil perhitungan, maka pressure drop yang diperoleh berada pada wilayah yang
diizinkan.
39
Lampiran Menara Distilasi
Koreksi tekanan
Tekanan pada puncak menara = 1 atm
Ns = 20
Nr = 12
Tekanan pada arus umpan = Tekanan pada puncak menara + Nr x ΔPr
= 1 atm + 12 x 0,0217 atm
= 1,2514 atm
Tekanan pada dasar menara = Tekanan pada arus umpan + Ns x ΔPs
= 1,2514 atm +20 x 0,0080 atm
= 1,4107 atm
40
Lampiran Menara Distilasi
Komponen Laju (kmol/jam) Fraksi mol (x) P° (mmHg) K= P°/P y =K*x αj = Ki/KHK
BD 1,0612 0,0049 1,3854 0,0015 0,0000 0,0031
H2O 110,4301 0,5099 479,1410 0,5038 0,2569 1,0588
THF 105,0632 0,4852 1456,6869 1,5317 0,7431 3,2190
Jumlah 216,5546 1,0000 1,0000
Komponen Laju (kmol/jam) Fraksi mol (y) P° (mmHg) K= P°/P x =y/k αj = Ki/KHK
BD 0,0000 0,0000 0,3987 0,0005 0,0000 0,0011
H2O 7,1137 0,0389 224,9068 0,2959 0,1314 0,6219
THF 175,7949 0,9611 840,4707 1,1059 0,8691 2,3242
Jumlah 182,9086 1,0000 1,0005
Komponen Laju (kmol/jam) Fraksi mol (x) P° (mmHg) K= P°/P y =K*x αj = Ki/KHK
BD 0,0000 0,0000 0,3402 0,0004 0,00000 0,0009
H2O 4,2089 0,0389 204,1792 0,2687 0,01045 0,5646
THF 104,0125 0,9611 783,3239 1,0307 0,99060 2,1662
Jumlah 108,2215 1,0000 1,00105
41
Lampiran Menara Distilasi
Komponen Laju (kmol/jam) Fraksi mol (x) P° (mmHg) K= P°/P y =K*x αj = Ki/KHK
BD 0,0000 0,0000 0,3402 0,0004 0,00000 0,0009
H2O 2,9047 0,0389 204,1792 0,2687 0,01045 0,5646
THF 71,7824 0,9611 783,3239 1,0307 0,99060 2,1662
Jumlah 74,6871 1,0000 1,00105
c. Dasar menara
Komponen Laju (kmol/jam) Fraksi mol (x) P° (mmHg) K= P°/P y = k*x αj = Ki/KHK
BD 1,0612 0,0098 5,2459 0,0049 0,0000 0,0049
H2O 106,2212 0,9805 1067,7877 0,9959 0,9765 1,0013
THF 1,0506 0,0097 2606,6395 2,4312 0,0236 2,4443
Jumlah 108,3331 1,0000 1,0001
Komponen Laju (kmol/jam) Fraksi mol (y) P° (mmHg) K= P°/P x =y/k αj = Ki/KHK
BD 1,7918 0,0098 19,2277 0,0179 0,5462 0,0180
H2O 179,3429 0,9805 2317,4198 2,1615 0,4536 2,1731
THF 1,7739 0,0097 4579,8060 4,2716 0,0023 4,2945
Jumlah 182,9086 1,0000 1,0021
42
Lampiran Menara Distilasi
Tinggi penyangga
Dirancang : tinggi penyangga (H1) = 2 m
Tinggi ruang kosong bawah (H2)
Dihitung berdasarkan Kister, H.Z., Distillation Operation, Mc Graw Hill, New York, 1991, hal.
84.
Sketsa :
Untuk menghitung tinggi ruang kosong bawah, maka perlu
dihitung tingi cairan, dan diameter pipa.
Tinggi cairan :
Dihitung dengan menggunakan persamaan :
Vl
Hl =
At
L1 .θ
Vl = ρl
Dimana :
H1 : tinggi cairan (m)
V1 : volume cairan (m3)
At : luas penampang menara (m2)
L1 : kecepatan volume cairan (m3/s)
θ : waktu tinggal cairan (s)
ρ1 : rapat massa cairan (kg/m3)
43
Lampiran Menara Distilasi
0,1969 𝑚3
Hl = = 0,0649 𝑚
3,0321 𝑚2
Dimana :
Dnozzle : diameter pipa nozzle (m)
Ap : luas penampang pipa nozzle (m2)
4000
vlin = √
ρm
44
Lampiran Menara Distilasi
Dimana :
vlin : kecepatan linear fluida (ft/s)
ρm : rapat massa campuran (lb/ft3)
4000 4000 𝑓𝑡
vlin = √ = √0,0366 = 330,4491 = 100,7209 m/s
ρm 𝑠
𝑚3
1,6652
Ap = s
𝑚 = 0,0165 𝑚2
100,7209
𝑠
4 𝑥 𝐴𝑝 4 𝑥 0,0165 𝑚2
Dnozzle = √ = √ = 0,1451 𝑚 = 5,7135 𝑖𝑛
𝜋 3,14
45
Lampiran Menara Distilasi
Dipilih :
6 NPS, Sch No 80
Diameter luar : 6,625 in
Diameter dalam : 5,761 in
H2 = 0,0649 𝑚 + (12+18+6,625) in x 0,0254 m/in = 0,9952 m
46
Lampiran Menara Distilasi
Tinggi Total
Ht = 2 m + 0,9952 m + 9,2614 m + 1 m
Ht = 13,2567 m
Menentukan ukuran pipa
Diameter optimum pipa dengan bahan carbon steel (Towler, hlm 269)
𝐷𝑖, 𝑜𝑝𝑡 = 0,534 𝐺 0,45 𝜌−0,30
Keterangan :
Di,opt = Optimum inside diameter (m)
G = Fluid flow rate (kg/s)
𝜌 = Fluid density (kg/m3)
Dipakai diameter pipa standar dengan ukuran 5,761 in (Tabel 10, Kern hlm 843)
2. Pipa pemasukan refluks distilasi
Kecepatan refluks (G) = 5228,5137 kg/jam
= 1,4524 kg/s
Densitas refluks (𝜌) = 834,9319 kg/m3
𝐷𝑖, 𝑜𝑝𝑡 = 0,534 (1,4524 )0,45 (834,9319 )−0,30 = 0,0839 𝑚 = 3,3048 𝑖𝑛
Dipakai diameter pipa standar dengan ukuran 3,826 in (Tabel 10, Kern hlm 843)
47
Lampiran Menara Distilasi
Dipakai diameter pipa standar dengan ukuran 25,25 in (Tabel 10, Kern hlm 843)
4. Pipa pengeluaran uap puncak menara distilasi
Kecepatan uap (G) = 12804,6191 kg/jam
= 3,5568 kg/s
Densitas uap (𝜌) = 2,4930 kg/m3
𝐷𝑖, 𝑜𝑝𝑡 = 0,534 (3,5568 )0,45 (2,4930 )−0,30 = 0,7186 𝑚 = 28,2925 𝑖𝑛
Dipakai diameter pipa standar dengan ukuran 28,2925 in (Tabel 10, Kern hlm 843)
5. Pipa pengeluaran cairan dasar menara distilasi
Kecepatan cairan (G) = 5600,9457 kg/jam
= 1,5558 kg/s
Densitas cairan (𝜌) = 948,0609 kg/m3
𝐷𝑖, 𝑜𝑝𝑡 = 0,534 (1,5558 )0,45 (948,0609 )−0,30 = 0,0833 𝑚 = 3,2812 𝑖𝑛
Dipakai diameter pipa standar dengan ukuran 3,826 in (Tabel 10, Kern hlm 843)
48
Lampiran Menara Distilasi
Neraca panas
Tabel Data kapasitas panas
ΔH Masuk
Komponen Laju (kmol/jam) ʃ Cpi dT (kJ/kmol) (kJ/jam)
BD 1,061244174 -53476,38587 -56751,50296
THF 105,0631732 -25081,72609 -2635165,734
H2O 110,4301387 -39865,71085 -4402375,98
Total 216,5545561 -118423,8228 -7094293,217
49
Lampiran Menara Distilasi
Panas Sensibel
Suhu Masuk kondensor = 342,2455 K
Suhu Keluar Kondensor = 340,6380 K
340,6380
ΔH Sensibel = ∫ 𝑛𝑖 ∑ 𝐶𝑝𝑖 𝑑𝑇
298
ΔH Hasil atas
Komponen Laju (kmol/jam) ʃ Cpi dT (kJ/kmol) (kJ/jam)
BD 0 -34542,1514 0
THF 104 -16255,8656 -1690610,022
H2O 4,2089 -25638,24746 -107908,8198
Total 108,2089 -76436,26446 -1798518,842
ΔH Hasil atas
Komponen Laju (kmol/jam) ʃ Cpi dT (kJ/kmol) (kJ/jam)
BD 0 -35992,19849 0
THF 104 -16933,41092 -1761074,736
H2O 4,2089 -26724,14659 -112479,2606
Total 108,2089 -79649,756 -1873553,996
ΔH Hasil bawah
Komponen Laju (kmol/jam) ʃ Cpi dT (kJ/kmol) (kJ/jam)
BD 1,0612 -75558,99304 -80186,54117
THF 1,0506 -35329,30953 -37118,09368
H2O 106,2212 -56572,61159 -6009210,196
Total 108,3331 -167460,9142 -6126514,8312
50
Lampiran Menara Distilasi
51
Lampiran Menara Distilasi
KESIMPULAN
1. Kondisi operasi
Umpan
Umpan masuk MD
Tekanan = 1,2514 atm
Suhu = 87,7209 Celsius
Puncak menara
Uap masuk kondensor
Tekanan = 1,00 atm
Suhu = 69,2455 Celsius
Produk atas MD
Tekanan = 1,00 atm
Suhu = 67,0381 Celsius
Cairan refluks
Tekanan = 1 atm
Suhu = 67,0381 Celsius
Dasar menara
Produk bawah MD
Tekanan = 1,4107 atm
Suhu = 109,9876 Celsius
2. Jumlah Plate
Jumlah Plate pada seksi
Stripping = 20 Plate
Rectifying = 12 Plate
3. Dimensi menara distilasi
Tinggi = 13,2567 m
Dimater = 1,9653 m
4. Tebal menara distilasi
Shell = 0,31 in
Head = 0,31 in
5. Perancangan plate
Seksi Enriching
52
Lampiran Menara Distilasi
53