Anda di halaman 1dari 15

PROJECT

HOTEL HORISON JIMBARAN


Rencana Perbaikan
Kebocoran
Lantai Basement
Analisa Hasil Survey
22 Januari 2022
N A N O - S TA R
N A N O T E C H W AT E R P R O O F I N G & P R O T E C T I O N

Lantai Basement
N A N O - S TA R
N A N O T E C H W AT E R P R O O F I N G & P R O T E C T I O N

1. Ruang
Laundry
N A N O - S TA R
N A N O T E C H W AT E R P R O O F I N G & P R O T E C T I O N

2. Receiving Area
N A N O - S TA R
N A N O T E C H W AT E R P R O O F I N G & P R O T E C T I O N

3. Ruang Kantor
N A N O - S TA R
N A N O T E C H W AT E R P R O O F I N G & P R O T E C T I O N

4. Ruang Genset
N A N O - S TA R
N A N O T E C H W AT E R P R O O F I N G & P R O T E C T I O N

5. Pit Lift
N A N O - S TA R
N A N O T E C H W AT E R P R O O F I N G & P R O T E C T I O N

6. Gudang
N A N O - S TA R
N A N O T E C H W AT E R P R O O F I N G & P R O T E C T I O N

7. Ruang Pompa
N A N O - S TA R
N A N O T E C H W AT E R P R O O F I N G & P R O T E C T I O N

Parking & Loading


N A N O - S TA R
N A N O T E C H W AT E R P R O O F I N G & P R O T E C T I O N

Parking & Loading


N A N O - S TA R
N A N O T E C H W AT E R P R O O F I N G & P R O T E C T I O N

Rencana Perbaikan Lantai Basement

1. Prediksi sumber kebocoran dikarenakan tekanan air tanah yang


sangat tinggi sehingga menembus ke dalam struktur beton plat
lantai dan kolom basement.
2. Area lantai dan dinding yang mengalami rembesan air tanah,
finishingnya harus dibobok dan dibuka semua sampai ketemu
beton asli.
3. Untuk mengurangi tekanan air tanah yang sangat tinggi perlu
dibuatkan beberapa titik sumur bor di area hotel yang nantinya
akan disedot oleh pompa (Dewatering Method).
4. Setelah masalah tekanan air bisa diatasi maka dilakukan
aplikasi penggunaan material NCW & MBC pada plat lantai dan
dinding di area basement hotel.
5. Untuk menjaga agar ke depannya tidak bocor lagi, NCW & MBC
akan diaplikasikan di dinding sekeliling basement dengan
ketinggian 80 cm dan area lantai basement dengan perkiraan
70% dari luasan yang ada.
N A N O S TA R
N A N O T E C H W AT E R P R O O F I N G & P R O T E C T I O N

N C W – N EG AT IVE C EMEN T W ED G E

DESKRIPSI PRODUCT :
Negative Cement Wedge (NCW) adalah pasak padat teknologi titanium nano
berbasis semen. NCW membantu MBC dengan reaksi yang sangat cepat
untuk menghentikan kebocoran air mengalir.
MATERIAL UTAMA : Titanium Nano
FUNGSI : Membantu MBC pada kasus kebocoran
berat / air mengalir
AREA APLIKASI : Dinding dan Lantai Beton yang
mengalir air, pit lift, dan tambalan/perbaikan beton
pada dinding kolam/WTP/WWTP
GARANSI INDONESIA* : 2 Tahun
DAYA SEBAR : N/A (tergantung lubang kebocoran)
CURING TIME : 3 menit
*Syarat dan Ketentuan Berlaku
N A N O S TA R
N A N O T E C H W AT E R P R O O F I N G & P R O T E C T I O N

MB C – MO IST U R E B A R R IER C O AT
DESKRIPSI PRODUCT :
Moisture Barrier Coat (MBC) adalah waterproofing teknologi titanium nano
berbasis semen yang di-design untuk menahan air dari sisi negatif. MBC
mengandung zat aktif yang mampu bereaksi jauh ke dalam beton/substrat
yang mengalami kebocoran/merembes dengan membentuk jaring-jaring
nano penahan air.
MATERIAL UTAMA : Titanium Nano
FUNGSI : Waterproofing Sisi Negatif
AREA APLIKASI : Dinding dan Lantai Beton yang
bocor, rembes, dan bahkan mengalir air, basement,
pit lift, kebocoran bawah tanah lainnya, dan
tambalan/perbaikan beton.
GARANSI INDONESIA* : 2 Tahun
DAYA SEBAR : 5 – 8 Sqm / 10 Kg (tergantung
tingkat kebocoran)
CURING TIME : 3 – 4 minggu
*Syarat dan Ketentuan Berlaku
N A N O S TA R
N A N O T E C H W AT E R P R O O F I N G & P R O T E C T I O N

THANK
YOU

PT Dunia Konstruksi Mandiri


Jln Pulau Ayu 36, Denpasar 80123, Bali
Anang Suryana +62 818 993 198
HDG
Dicky V1 +62 819 9906 3999
Priyono

Anda mungkin juga menyukai