HEAT EXCHANGER
A. Menentukan volume fluida dingin pada percobaan dengan waktu yang ditentukan.
Data kalibrasi yang didapat:
Waktu (detik) Volume (Liter) Volume rata-rata
2
3 2 2
2
3
5 2 2,41
2,25
3,5
7 3 3,16
3
5
9 4 4,33
4
Grafik kalibrasi antara volume fluida dingin dan waktu kalibrasi:
5
Volume rata-rata (V)
4
f(x) = 0.387 x + 0.653
3 R² = 0.953912295786759
2
1
0
2 3 4 5 6 7 8 9 10
Waktu (detik)
= 1,81512 lbm/jam ft
12 x L 12 x 47,244
N+1 =
B
=
5,22
= 108,606
( )P
0,9 8,7
= 0,785 1
( )
2
T 2
2
do
d o
2
75,69 in
= 0,785 x 0,9 x 2
1,25 in
= 34,22 = 34 in = 2,83 ft
Flow Area Flow Area
IDs x c' x B Nt x a'
as = (Kern, at = (Kern,
n' x 144 x P T n' x 144
1983) 1983)
8,7 x 0,8 x 5,22 34 x 0,0625
= =
1 x 144 x 1,25 2 x 144
= 0,202 in2 = 0,0014 ft2 = 0,00737 in2 = 0,0000512 ft2
M Q x ρc M Q x ρh
Gs = =ac Gt =
at
=ah
as s t
[ ] [ ]
0,14 0,14
μb μb
Karena cairan tidak kental maka =1 Karena cairan tidak kental maka =1
μW μW
[ ][ ] [ ]
1/3 0,14 0,14
D μb 1/3 μb
NNus = 1,86 x NRe x Npr x NNus = 0,027 x N Re0,8 x N pr
L μW μW
= 0,027 x 1.332.973,7450,8 x 4,671 1/3 x
[ ]
0,725
1/3
1
= 1,86 x 170.978,1246 x 5,049 x x
3,937 = 0,027 x 79.406,723 x 1,6716
1 = 3.583,879
= 1,86 x 54,171 x 1
= 100,758
Menghitung ho Menghitung hi dan hio
[ ]
μ
-0,14
kh
Karena cairan tidak kental maka =1 hi = Nnus x
μW di
[ ]
1/3 0,3619
x [
μW ]
kc Cpc x μ c μ
−0 ,14
= 3.583,879 x
= JH x x 0,0586
de kc
ho
= 22.133,204 Btu/jam ft2 ⁰F
[ ]
1/3
0,3591 0,999 x 1,8112 di
= 270 x x x1 hio = hi x
0,0825 0,3591 do
¿270 x 4,352 x 1,715 0,0586
2 = 22.133,204 x
¿ 2.015,1936 Btu/jam ft ° F 0,0833
= 15.570,297 Btu/jam ft2 ⁰F
12 x L 12 x 47,244
N+1 =
B
=
5,22
= 108,606
( )P
0,9 8,7
= 0,785 1
( )
2
T 2
2
do
d o
75,69 in 2
= 0,785 x 0,9 x
1,25 in 2
= 34,22 = 34 in = 2,83 ft
Flow Area Flow Area
IDs x c' x B Nt x a'
as = (Kern, 1983) at = (Kern, 1983)
n' x 144 x P T n' x 144
8,7 x 0,8 x 5,22 34 x 0,0625
= =
1 x 144 x 1,25 2 x 144
= 0,202 in2 = 0,0014 ft2 = 0,00737 in2 = 0,000051 ft2
M Q x ρc M Q x ρh
Gs = =ac Gt =
at
=ah
as s t
[ ][ ]
D
1/3
μb
0,14 μW
NNus = 1,86 x NRe x Npr x
L μW
[ ]
0,14
0,8 1/3 μb
NNus = 0,027 x N x N pr
[ ]
Re
0,725
1/3 μW
= 1,86 x 169.094,855 x 5, 11 x x1
3,937
= 0,027 x 7.128.116,940,8 x
1/3
4,687 x1
= 1,86 x 54,188 x 1 = 13.720,66
= 100,789
Menghitung ho Menghitung hi dan hio
[ ] kh
-0,14
μ
Karena cairan tidak kental maka =1
μW
hi = NNut × di
[ ]
1/3 0,36185
x [
μW ]
kc Cpc x μ c μ
−0 ,14
= 13.720,66 ×
= JH x x 0,0586
de kc
ho
= 84.723,904 Btu/jam.ft2.oF
[ ]
1/3
0,35873 0,999 x 1,835 di
= 265 x x x1
0,0825 0,3587 hio = hi× d o
¿270 x 4,348 x 1,722 0,0586 ft
= 84.723,904 ×
¿ 2.021,559 Btu/jam ft 2 ° F 0,0833 ft