Kualitas citra Coronary CT-Angiography (CCTA) mempunyai peranan penting
dalam mendeteksi aterosklerosis. Aterosklerosis merupakan penyebab terbesar cardiovascular disease (CVD). CCTA memiliki kemampuan untuk menentukan karakteristik plak dan kuantifikasi volume plak. Salah satu faktor yang dapat mempengaruhi evaluasi plak ateroskleoris adalah filter kernel. Tujuan penelitian ini adalah untuk mengetahui pengaruh variasi filter kernel dalam mengevaluasi plaque burden pada pemeriksaan coronary ct-angiograpy (CCTA). Dari 20 pasien, didapatkan sebanyak 30 sampel plak aterosklerosis yang terdiri dari 15 (50%) non-calcified plaque (NCP) dan 15 (50%) calcified plaque (CP). Tiga level filter kernel digunakan dalam rekonstruksi, kemudian dihitung nilai atenuasi (HU), total volume plak (TPV), dan plaque burden (PB). Perhitungan nilai atenuasi melalui nilai ROI dipertengahan plak dan TPV serta PB menggunakan aplikasi otomatis. Hasil penelitian menunjukkan ada perbedaan yang signifikan (pvalue<0,05) pada nilai atenuasi NCP, nilai atenuasi CP, dan TPV, sedangkan pada PB menunjukkan tidak ada perbedaan yang signifikan (pvalue>0,05). Maka dapat disimpulkan bahwa filter kernel mempengaruhi nilai atenuasi dan TPV, namun pada PB pengaruh variasil filter tidak berpengaruh. Hal ini karena PB merupakan volume plak yang dinormalisasikan dengan volume total pembuluh darah.
Kata kunci: plak aterosklerosis, plaque burden, filter kernel
1 Mahasiswa Program Studi D-IV Teknologi Radiologi Pencitraan Departemen Kesehatan Fakultas Vokasi Universitas Airlangga, Surabaya 2 Staff Radiologi Departemen Kesehatan Fakultas Vokasi Universitas Airlangga, Surabaya 3 Staff Radiografer Rumah Sakit Umum Daerah Dr.Soetomo, Surabaya
ix
SKRIPSI PENGARUH VARIASI FILTER... RIZKY UTAMI AYUNINGDYAH
IR - PERPUSTAKAAN UNIVERSITAS AIRLANGGA
ABSTRACT
Influence of Kernel Filters Variations to Evaluate Plaque Burden on
Image quality has a mayor role to evaluate atherosclerosis. Atherosclerosis is
well-known as the common cause of cardiovascular disease (CVD). CCTA has the ability to determine plaque characterization and quantification of plaque volume. There were several factors that influenced CCTA to evaluating atherosclerosis plaque, one of them is kernel filter. The aim of this study was to determine the influence of kernel filter to evaluate plaque burden on coronary ct- angiography (CCTA). Of 20 patients, there are 30 samples of atherosclerotic plaque consisted 15 (50%) non-calcified plaque (NCP) and 15(50%) calcified plaque (CP). Each sample was reconstructed using three kernel filters then the attenuation values (HU), total plaque volume (TPV), and plaque burden (PB) were calculated. ROI placed in the middle of plaque to measured the attenuation values. The TPV and PB were determined using automated software. The results showed there were significant differences (pvalue<0,05) in NCP and CP attenuation values and TPV, meanwhile in PB showed that there were no significant differences (pvalue>0,05). It can be concluded that kernel filter affects the attenuation values and TPV, but not on PB. It could be PB is normalized plaque volume to the total of coronary vessel volume.
1 Student of Radiologic Imaging Technology Program, Departement of Health Studies, Faculty of Vocational Studies, Universitas Airlangga, Surabaya 2 Staff of Radiologic Imaging Technology Program, Departement of Health Studies, Faculty of Vocational Studies, Universitas Airlangga, Surabaya 3 Staff Radiographer of Dr.Soetomo Hospital, Surabaya
SKRIPSI PENGARUH VARIASI FILTER... RIZKY UTAMI AYUNINGDYAH