Design By WESHARDIN
Q2 : MCB2 out Trafo 110 Vac supply PLC E/S : Emergency stop
K1 : Kontaktor Main Up (Esc Up) /K1KMU NPR Phase relay 3 phase 380
Notes symbol
RSS
Design By Mr. Weshardin Page :
Date 2 Novemeber -2021
MODIFIKASI PANEL ESCALATOR
PILLAR
Emergency stop Toogle Auto RUN
Selector Switch Power
Power supply
24 vdc /5A
MCB control
Phase Relay
Trafo kontroll
Kontaktor UP
MCB fuse 10Al Kontaktor UP
Kontaktor Down
Kontaktor
Safety Panel
ty
MODIFIKASI PANEL ESCALATOR EX PILLAR
OPERATIONAL MANUAL
TROUBELE SHOOTING
Q1 MCB 3 P
MCB Q2
`
SR/U 1 3 5 1 3 5
KMU KMD
L (K1) (K2)
N SR/D
220 VAC
2 4 6 2 4 6
Trafo 1
`110 VAC
` MCB OLR
u1 v1 w1
Q3
NOTE :
MOTOR 3p
TB-1 8 kw KONTAKTOR K4 DELTA
TB-2 u2 v2 w2 SPARE
PE
FOR USING DELTA OR STAR SPEED MODE
P/S 24 VDC 1 3 5 jumper N24 --- X15 plc
WIRING DAYA DELTA SUDAH TERPASANG
K3/ STAR SISTEM DELTA DIPAKAI JIKA PENUMPANG
TB- 4/5
SYA KONDISI PENUH
TB 10/11/12
2 4 6
mcb fuse 10 A
NPR A2
A2 A2 A2 A2
6
A1 A1 A1 A1 A1
95 22 22
KR kmd kmu
safety Kontak 21 21
96
9 5 5 9
A2
(SA) (SB) SU
A1
MCB
PLC WIRING LAY OUT 110 VAC (Q3)
PILLAR ESCALATOR MODIFIKASI Trafo 110 vac
Mr. Weshardin Page :
Jika menggunakan
220 VAC 110 VAC
Out Q2 Out Q3
RELAY Safety
6
MCB 14 14
SA SA SB
10
13 13
D10 D21
14 14 P24 kabel 11
K1 K2
MCB-Fuse 10 A
13 13
PS-24 VDC
Jalur Jalur
10 N24
Safety ATAS Safety BAWAH
SB
6
Netral D1 D13
kabel 9
UVW
BRAKE Catatan :
MOTOR
safety kabel
atau hijau-merah
dari PLC OUTPUT Y5
JIKA BRAKE PAKAI ktk 110 vac
MOTOR 3 PHASE DIAGRAM SAFETY LINE + BRAKE SYSTEM
PT.RSS
Page : Design By Mr. Weshardin
Date 02-Nov-21
TERMINAL FUNCTION PANEL UTAMA A / TA/TB
DALAM PANEL
Terminal TA 1 2 3 4
DALAM PANEL
Terminal TB 1 2 3
Terminal TD 1 2 3 4 5 6 7 8 9 10 11 12
Terminal TD 13 14 15 16 17 18 19 20 21 22 23 24
Terminal TC 1 2 3 4