WAHYUDI SARIMUN.N
WYD SN
PENGERTIAN DASAR TENTANG REAKTANSI
A B
Kawat mempunyai tahanan 2 ohm
S
+ Fluks/garis-garis gaya magnit
BAT.
-
WYD SN - PRI.K
PENGERTIAN DASAR TENTANG REAKTANSI
1,5 Volt
= 0,75 Amper MASIH SAMA DENGAN DI KAWAT
2W
WYD SN - PRI.K
PENGERTIAN DASAR TENTANG REAKTANSI
DIMANA NILAI HAMBATAN “ L “ YANG IMAJINER ITU MEMBENTUK SUDUT 90o DENGAN “ R “
Sumbu imajiner
j
Sumbu riel
R
WYD SN - PRI.K
PENGERTIAN √3 PADA POWER 3 FASA
WYD SN - PRI.K
PENGERTIAN √3 PADA POWER 3 FASA
-
(VAB) 2 = (VAN) 2 + (VBN) 2 - 2 x VAN x VBN x COS (120O)
= (VAN) 2 + (VAN) 2 - 2 x VAN x VAN x ( - 0,5 )
= (VAN) 2 + (VAN) 2 + (VAN) 2
= 3 x (VAN) 2
VAB = √ 3 x VAN JADI V = √ 3 x VAN
V
WYD SN - PRI.K
ATAU VAN =
√3
PENGERTIAN √3 PADA POWER 3 FASA
KEMBALI KE :
PTOTAL 3 FASA = 3 x VAN x IA
3xVxI
=
√3
PTOTAL 3 FASA = √3xVxI
WYD SN - PRI.K
PENGERTIAN DAYA LISTRIK
DAYA LISTRIK
P = V.I.COS (watt) = Daya aktif
S = V.I (Volt Amp) = Daya semu
Q = V.I .Sin (Volt Amp reaktif) = Daya reaktif
WYD SN
PENGERTIAN RUGI JARINGAN
1. IMPEDANSI Z = R + jX
3. RUGI JARINGAN
- DAYA AKTIF I2R (WATT)--- I2R.h (WATT hour)
- DAYA REAKTIF I2X (VAr)
WYD SN
SISTEM PENYALURAN TENAGA LISTRIK
1. Pembangkit ( TM )
2. Trafo Step Up ( TM ke TT )
3. Jaringan Transmisi ( TET, TT )
4. Trafo Step Down Transmisi ( TET ke TT, TT ke TT )
5. Trafo Step Down Distribusi ( TT ke TM )
6. Jaringan Distribusi Primer ( TM )
7. Jaringan Distribusi Sekunder ( TR )
WYD SN
SISTEM PENYALURAN TENAGA LISTRIK
WYD SN
KONFIGURASI JARINGAN DISTRIBUSI PRIMER
• RADIAL
• OPEN LOOP
• CLOSE LOOP / TIE LINE
• SPINDLE
• CLUSTER
WYD SN
JARINGAN SISTEM RADIAL
Transformer
150-70/20 kV
Main Substation
TM
PMT PMT PMT
TS
TC
Keterangan
TM = Telemetering
TS = Telesignalling
TC = Telecontrolling
WYD SN
JARINGAN SISTEM OPEN LOOP
Transformer
150-70/20 kV
Main Substation
TM
PMT PMT PMT
TS
TC
Keterangan
TM = Telemetering
TS = Telesignalling
TC = Telecontrolling
WYD SN
JARINGAN SISTEM CLOSED LOOP / TIE LINE
Transformer Transformer
150-70/20 kV 150-70/20 kV
TM
PMT PMT PMT PMT
TS
TC
Keterangan
TM = Telemetering
WYD SN TS = Telesignalling
TC = Telecontrolling
JARINGAN SISTEM SPINDEL
Transformer
150-70/20 kV
Main Substation
TM NC
PMT PMT PMT
TS
TC
Zone 1
* * *
* * *
Express
MP Feeder
Zone 2
* * *
Keterangan
* = GFD
* * * TM = Telemetering
TS = Telesignalling
TS NC
TC = Telecontrolling
LBS LBS NO MP = Middle Point
TC
Transformer
150-70/20 kV
Main Substation
LBS
*
NO Keterangan
* = GFD
TM = Telemetering
LBS TS = Telesignalling
TC = Telecontrolling
WYD SN NO
Terima Kasih