d 119 )
Fungsi
Bentuk
Bahan konstruksi : Refractory dengan tube terbuat dari bahan chrome-nickel (25 % Cr, 20 %
Ni, 0,35 0,45 % C grade HK-40)
Data :
Panas yang diperlukan
= 1921489,8213 kJ/jam
= 1821213,7900 Btu/jam
Temperatur keluar
= 700 C = 1292F
= 41595,7307 kg/jam
= 163,7627 kmol/jam
= 91701,9479 lb/jam
= ( 79/21 ) x mol O2
= (79/21) x 393,0305
= 1478,5434 kmol/jam
= 393,0305 + 1478,5434
= 1871,5739 kmol/jam
= 1871,5739 kmol/jam x 28,84 kg/kmol
= 53976,1923 kg/jam
= 118995,9135 lb/jam
= 12000 Btu/jam.ft2
Q
2
=2 x average flux=2 x 12000=24000 Btu/ jam ft
A Cp
Overall exchange factor ( ) = 0,57
Q
24.000
2
=
=42105,2631 Btu / jam ft
A Cp
0,57
(Kern,1965)
Jika temperatur tube ts = 12912F (700 C) maka dari Fig 19.14 (Kern,1965) diperoleh
temperatur flue gas keluar TG = 1900F = 2359,67 R
QF = 11121,0524 Btu/jam
Udara dipanaskan awal (preheat) pada 400F.
o
QA
(Geankoplis,1997)
o
Asumsi : QR = QS = 0
QW
QG
G =
QG=91701,9479 x 1+
91701,9479
x 0,247 x (2359,67520)
118995,9135
= 73780827,2957 Btu/jam
Q
= QF + QA Qw - QG
= 64012263,7575 Btu/jam
Keterangan :
Q
o
QA = Panas sensibel di atas 60 F pada pembakaran udara (Btu/jam)
o
QR = Panas sensibel di atas 60 F pada resirkulasi gas bakar (Btu/jam)
QS
o
= Panas sensibel di atas 60 F pada steam yang digunakan (Btu/jam
= 2 8 in
Bahan konstruksi = chrome-nickel (25% Cr, 20% Ni, 0,350,45% C grade HK-40)
Panjang tube
= 10 40 ft
Diambil:
OD tube
= 7 in
Panjang tube
= 35 ft
Luas permukaan/tube
Jumlah tube , Nt =
64012263,7575
=83,1663 buah 84 buah
12000 x 64,1409
Coba 84 tube
Acp per tube=
85
x 35=24,7917 ft 2
12
Total untuk single row refractory backed dari Fig. 19.11 Kern, hal: 688 dengan rasio
dari centre to centre / OD
2
Acp
= 8,5/7
= 24,5483 ft x 84
2
2
= 2061,6750 ft
Permukaan refractory :
2
= 1275,4132 ft
End walls
Side walls
= 2 x 29,0417 x 21,9583
= 21,9583 x 35
Bridge walls
Floor and
= 10,625 x 35
= 2 x 29,0417 x 35
arch
= 768,5417 ft
= 371,8750 ft
= 2032,9167 ft
AT
= 4448,7464 ft
2
23
Vol. furnace
3
L=
23
35 x 29,0417 x 21,9538=18,7703 ft
3
PCO
= 0,1084
PHO
= 0,1284
PCO.L
PHO.L
Dari Fig 19.12 dan Fig 19.13, Kern, hal: 693 dan 694 diperoleh:
(q pada PCO2.L)TG = 10.000 Btu/jam.ft
(q pada PCO2.L)ts = 2.700 Btu/jam.ft
T
(qb)TG =0,173 b G dan b=1,00
100
(qb)TG =53635,3585
4
(qb)ts =0,173 b
ts
100
(qb)ts =16287,5316
asumsi : % koreksi = 8 %
(Kern,1965)
AR
=1,1578
A Cp
Q
=44355,2408 maka desain dapat diterima
A Cp .