Anda di halaman 1dari 22

KAJIAN KAPASITAS BANGUNAN

SNI 03-1726-2002 TERHADAP SNI


1726-2012 DENGAN METODE STATIC
PUSH-OVER
DRADJAT HOEDAJANTO
MUHAMMAD RIYANSYAH
(FEDERAL EMERGENCY MANAGEMENT AGENCY)

ACI 318: LDP ADALAH


Earthquake KONSULTAN
Resistant Design PERENCANA DAN
is a job for a KONSULTAN
PENGAWAS
specialist (LDP).
LDP = Licensed Design Profesional (UU-RI No.18 th. 99: Penyedia Jasa)
HAKI CONFERENCE: DH-MR - KAJIAN KAPASITAS BANGUNAN SNI 03-1726-2002 TERHADAP SNI 1726-2012 8/23/2016
2
KONSEP PERFORMANCE DAN EVALUATION

Target Minimum

HAKI CONFERENCE: DH-MR - KAJIAN KAPASITAS BANGUNAN SNI 03-1726-2002 TERHADAP SNI 1726-2012 8/23/2016 3
6. Spectral Response Acceleration (disain)

1 2 SRA 2
6. SRA 1
Active fault
PGA 2
5. Ground Acceleration
Rocks
Soft Soil
4. Amplification
3. PGA 1
1. Earthquake source 3. Peak Ground Acceleration
2. Wave propagation di level batuan dasar
(Attenuation)

CATATAN:
SRA MERUPAKAN FUNGSI DARI NILAI PGA DI LEVEL BATUAN DASAR DAN PERSAMAAN AMPLIFIKASI KE PERMUKAAN
AMPLIFIKASI TANAH LUNAK > AMPLIFIKSI TANAH SEDANG
KECUALI KASUS DE-AMPLIFIKASI, BILA NILAI PGA NAIK MAKA UMUMNYA NILAI SRA JUGA NAIK

THE MECHANIC OF EQS WAVE PROPAGATION


(DAMPAK DARI ATTENUASI DAN AMPLIFIKASI)
HAKI CONFERENCE: DH-MR - KAJIAN KAPASITAS BANGUNAN SNI 03-1726-2002 TERHADAP SNI 1726-2012 8/23/2016 4
SNI 03-1726-2002 1726-2012
DATA PGA 15%(g) 33-35%(g)
SECARA TEKNIS KEMUNGKINAN
RS SNI 2002 SALAH

0.8
Spektral Percepatan (g) 0.7
? Dengan asumsi SNI 2012 lebih
akurat, fakta ini menunjukkan
0.6 OK adanya kejanggalan terkait
proses amplifikasi SNI 2002
0.5

0.4

0.3 Soft SNI-2002


Medium SNI-2012
Medium SNI-2002
0.2 Soft SNI-2012

Tanah Soft
Tanah Medium
0.0 ( 10 lantai) ( 20 lantai) ( 30 lantai) T (detik)
0.0 1.0 2.0 3.0 4.0
SPEKTRA JAKARTA SNI 2002 VS SNI 2012 (IRSYAM - 2012)
HAKI CONFERENCE: DH-MR - KAJIAN KAPASITAS BANGUNAN SNI 03-
8/23/2016 5
1726-2002 TERHADAP SNI 1726-2012
GRAVITASI & OPERATI
ANGIN
ONAL

LIFE
SAFETY
SNI 03-1726-2002

SNI 03-1726-2002 BUILDING


Target performance Life Safety
COLLAPSE
PREVENTION
KRITERIA PENENTU
NOT OK
PUBLIC SAFETY
SNI 1726-2012 COLLAPSE

HAKI CONFERENCE: DH-MR - KAJIAN KAPASITAS BANGUNAN SNI 03-1726-2002 TERHADAP SNI 1726-2012 8/23/2016 6
STRUCTURAL ANALYSIS

Konsep dasar
NSP ELF

ELF = Equivalent Lateral Force - MRS = Modal Response Spectrum - LTH = Linear Time History - NSP = Non-
linear Static Push-over - NTH = Non-linear Time History
HAKI CONFERENCE: DH-MR - KAJIAN KAPASITAS BANGUNAN SNI 03-1726-2002 TERHADAP SNI 1726-2012 8/23/2016 7
PERILAKU MATERIAL STRUKTUR

HAKI CONFERENCE: DH-MR - KAJIAN KAPASITAS BANGUNAN SNI 03-1726-2002 TERHADAP SNI 1726-2012 8/23/2016 8
PENGARUH DARI CONFINEMENT BALOK

HAKI CONFERENCE: DH-MR - KAJIAN KAPASITAS BANGUNAN SNI 03-1726-2002 TERHADAP SNI 1726-2012 8/23/2016 9
STUDI KASUS
7 LANTAI
DESIGN CRITERIA
DEAD LOAD
SELF-WEIGHT
SLAB T=150 MM 4@5m
BALOK 250 MM X 400 MM
SIDL = 1.7 KPA
LIVE LOAD = 2.5 KPA
EQ LOAD
SNI 2002 JAKARTA
TANAH SEDANG
FC=30 MPA, FY=400 MPA
4@5m
HAKI CONFERENCE: DH-MR - KAJIAN KAPASITAS BANGUNAN SNI 03-1726-2002 TERHADAP SNI 1726-2012 8/23/2016 10
HASIL DISAIN SNI 03-1726-2002 : IMRF SNI GEMPA 2002
F7 Jakarta, Tanah
Sedang/Medium, IMRF
F6
COLUMN
250 x 250
F5 4D22

F4

COLUMN
F3 300 x 300
4D22
F2 BEAM BEAM
(SUPPORT) (MIDSPAN)
COLUMN 250 x 400 250 x 400
F1 400 x 400 T = 7D16 T = 2D16
8D19 B = 3D16 B = 4D16
S = D10@75 S = D10@175
8/23/2016 11

4@5m
FIRST YIELD AT BEAM FIRST YIELD AT COLUMN BEAM COLLAPSES

Pushover Curve
GEDUNG 500
450

SNI-2002 400
350
300
IMRF THD 250
200

SNI 150
100
MULAI PARTIAL
COLLAPSE 8/23/2016 12

1726:2012 50
0
0,00 0,10 0,20 0,30 0,40 0,50
GEDUNG SNI 2002 DENGAN DITAILING SMRF SNI GEMPA 2002
F7 Jakarta, Tanah
Sedang/Medium, SMRF
F6
COLUMN
350 x 350
F5 4D22

F4

COLUMN
F3 400 x 400
8D19
F2 BEAM BEAM
(SUPPORT) (MIDSPAN)
COLUMN 250 x 400 250 x 400
F1 400 x 400 T = 6D16 T = 2D16
8D19 B = 3D16 B = 3D16
S = D10@75 S = D10@175
8/23/2016 13

4@5m
FIRST YIELD AT BEAM FIRST YIELD AT COLUMN BEAM COLLAPSES

Pushover Curve
GEDUNG 500
450
SNI-2002 400
350

SMRF THD 300


250
200

SNI 150
100 MULAI PARTIAL
50 COLLAPSE 8/23/2016 14

1726:2012 0
0,00 0,10 0,20 0,30 0,40
KESIMPULAN KONSEPTUAL:
GEDUNG YANG DIDISAIN THD SNI 03-1726-2002
Pushover Curve DAPAT DIRETROFIT JADI SMRF DAN OK
500 TERHADAP SNI 1726:2012
450

400

350
SMRF
MULAI COLLAPSE
300 MULAI COLLAPSE
250

IMRF
200

150

100

50

0
0,00 0,05 0,10 0,15 0,20 0,25 0,30 0,35 0,40

HAKI CONFERENCE: DH-MR - KAJIAN KAPASITAS BANGUNAN SNI 03-1726-2002 TERHADAP SNI 1726-2012 8/23/2016 15
KETERBATASAN DARI ELF

HAKI CONFERENCE: DH-MR - KAJIAN KAPASITAS BANGUNAN SNI 03-1726-2002 TERHADAP SNI 1726-2012 8/23/2016 16
STRUCTURAL ANALYSIS

HAKI CONFERENCE: DH-MR - KAJIAN KAPASITAS BANGUNAN SNI 03-1726-2002 TERHADAP SNI 1726-2012 8/23/2016 17
PEER*) ON NSP FOR TALL BUILDINGS (2010)
MAYBE USEFUL AS A DESIGN AID IT PERMITS GRAPHICAL REPRESENTATION AND
SHOULD NOT BE RELIED UPON TO QUANTIFY VISUALIZATION OF PROGRESSION OF INELASTIC
RESPONSE CHARACTERISTICS FOR TALL BUILDINGS BEHAVIOR UNDER SIMPLIFIED LOADING
CAN ASSIST IN INDENTIFYING THE PRIMARY
DEPENDING ON THE OPTION USED, THEY
MODES OF INELASTIC BEHAVIOR UNDER FIRST
PRODUCE RESULTS OF UNKNOWN RELIABILITY
MODE RESPONSE
GENERALY UNABLE TO REPRODUCE PHENOMENA
THAT ARE A CONSEQUENCE OF DYNAMIC IN MANY PRATICAL CASES NOT CAPABLE OF
RESPONSE AND INELASTIC FORCE REDISTRIBUTION INDENTIFYING THE EFFECT OF VARIATIONS IN
FREQUENCY CONTENT OF THE GROUND
SHEAR FORCE AMPLIFICATION IN SHEAR WALLS
CAUSED BY FLEXURAL PLASTIC HINGING AT THE BASE MOTION AND THE VARIATION IN HIGHER MODE
OF THE WALL EFFECTS

HAKI CONFERENCE: DH-MR - KAJIAN KAPASITAS BANGUNAN SNI 03-1726-2002 TERHADAP SNI 1726-2012 8/23/2016 18

*) PACIFIC EARTHQUAKE ENGINEERING RESEARCH CENTER: DESIGN GUIDE LINE FOR TALL BUILDINGS
STRUCTURAL ANALYSIS
PUSHOVER ANALYSIS LOS ANGELES TALL BUILDING
KRAWWINKLER SEAOC - 1996 STRUCTURAL DESIGN COUNCIL 2014
THERE ARE GOOD REASON TO ADVOCATE (Untuk gedung dengan H >> 49m di
THE USE OF INELASTIC PUSHOVER ANALYSIS wilayah gempa)
FOR DEMAND PREDICTION
BUT IT IS COUNTER PRODUCTIVE TO USE IT
AS A GENERAL SOLUTION FOR ALL CASES
IT MAY BE VERY INACCURATE FOR
STRUCTURES IN WHICH HIGHER MODE
EFFECTS ARE SIGNIFICANT AND WHERE
STORY SHEAR FORCE VS STORY DRIFT ARE Tidak merekomendasikan NSP
SENSITIVE TO THE APPLIED LOAD PATTERN.
HAKI CONFERENCE: DH-MR - KAJIAN KAPASITAS BANGUNAN SNI 03-1726-2002 TERHADAP SNI 1726-2012 8/23/2016 19
2009 IBC HANDBOOK, STRUCTURAL PROVISIONS
(S. K. GHOSH & JOHN HENRY)
PUSH-OVER ANALYSIS IS NOT IT IS NOT PARTICULARLY APPLICABLE IN
FORMALLY RECOGNIZED IN IBC OR TALL STRUCTURES OR STRUCTURES WITH
ASCE 7-05 RELATIVELY LONG FUNDAMENTAL
IT IS HIGHLY RECOGNIZED IN ASCE 41 PERIODS OF VIBRATION
SEISMIC REHABILITATION OF EXISTING
BUILDINGS
THE INELASTIC STATIC PUSH-OVER IS
BETTER IN COUNTING THE STRENGTH
IRREGULARITY DISTRIBUTION

HAKI CONFERENCE: DH-MR - KAJIAN KAPASITAS BANGUNAN SNI 03-1726-2002 TERHADAP SNI 1726-2012 8/23/2016 20
ASPEK LEGAL SNI 1726:2012
SNI ADALAH STANDAR KONSTRUKSI YANG LEGALITASNYA DITETAPKAN DAN DI ATUR
DIKELUARKAN OLEH PEMERINTAH DALAM KUH PER PASAL 1320 DAN 1347
SNI KONSTRUKSI SECARA LEGAL OTOMATIS DAN TERKAIT LANGSUNG PADA UU RI NO.
BERLAKU DAN MENGIKAT DI INDONESIA 18 TH. 1999 TENTANG JASA KONSTRUKSI
ACI 318 ATAUPUN ASCE 7-10 DIKELUARKAN PASAL 8 DAN 9
OLEH LEMBAGA NON PEMERINTAH DAN BARU
JADI PERGANTIAN SNI 03-1726-2002 OLEH
PUNYA ASPEK LEGAL BILA DIJADIKAN BAGIAN
DARI KONTRAK PEKERJAAN KONSTRUKSI, SNI 1726:2012 OTOMATIS HARUS
LANGSUNG DIIKUTI OLEH SEMUA PIHAK DI
SECARA TEKNIS SNI KONSTRUKSI MERUPAKAN
INDONESIA, TERUTAMA LEMBAGA
TANGGUNG JAWAB DARI KEMEN PUPR YANG
BERFUNGSI SEBAGAI PEMBINA PEMERINTAH DAERAH DAN PUSAT

HAKI CONFERENCE: DH-MR - KAJIAN KAPASITAS BANGUNAN SNI 03-1726-2002 TERHADAP SNI 1726-2012 8/23/2016 21
TERIMA KASIH

HAKI CONFERENCE: DH-MR - KAJIAN KAPASITAS BANGUNAN SNI 03-1726-2002 TERHADAP SNI 1726-2012 8/23/2016 22

Anda mungkin juga menyukai