JENIS TOWER

TRANSMISI DI PLN

Selasa, 6 mei 2014


PT PLN (Persero) UIP XIII

PT. PLN (PERSERO)


PUSAT ENJINIRING KETENAGALISTRIKAN
Lattice Tower Transmisi

150 kV Crossing mahakam


Transmission Line

Sumber : http://bit.ly/1id6uBe
Lattice Tower Transmisi

SUTET 275 kV Lattice Tower

Sumber : http://bit.ly/1i7Oj4d
Lattice
Tower
Transmisi

Sumber : http://bit.ly/1iXr5yE
Lattice Tower
Transmisi

Sumber : http://bit.ly/1q2UvA4
SUTET 500 kV sirkit ganda Lattice Tower
Lattice Tower
Transmisi

SUTET 500 kV HVDC Lattice Tower


Sumber : http://bit.ly/SnifQR
Tiang Baja (Tubular Steelpole)

Steelpole 500 kV Cawang – Muara tawar


Sumber : http://bit.ly/1mqOwPC
Sumber : http://bit.ly/RddjNs
Tiang Beton

Sumber : http://bit.ly/1ofnZGg
Tipe Tower SUTT 70 kV &
150 kV Lattice Tower
Sudut belok
NO Type Tower Type Insulator
Jalur ()

1 AA 0° - 3° Gantung


2 BB 0° - 20° Tarik

3 CC 20° - 40° Tarik dengan jumper

4 DD 40° - 60° Tarik dengan jumper

5 EE 60° - 90° Tarik dengan jumper

6 DDR 0°-60° Tarik dengan jumper


Tipe Tower SUTET 275 kV &
500 kV Lattice Tower
Type Sudut belok
NO Type Insulator
Tower Jalur ()

1 AA 0° - 5° Gantung

2 BB 0° - 10° Tarik

3 CC 10° - 30° Tarik dengan jumper

4 DD 30° - 60° Tarik dengan jumper

5 EE 60° - 90° Tarik dengan jumper

6 FF Terminal tower tension 45° entry Tarik dengan jumper


Tipe Tiang SUTT 70 kV &
150 kV
Desain Span (Rentang) untuk
Lattice Tower

Wind span : jarak rata-rata dari 2 bentang


(span) yang berdekatan
Weight span : jarak antara titik terendah
konduktor pada 2 bentang (span) yang
berdekatan
Desain Span (Rentang) untuk
Lattice Tower
Rentang Rentang Berat (m) Rentang Angin (m)
No Tower Dasar
(m) Normal Abnormal Normal Abnormal

1 66 KV 250 500 300 350 300

2 150 KV 350 700 400 500 400

Tower gantung = 800 Tower gantung = 800


Tower sudut = 1200 Tower sudut = 1200
Minimum weight Minimum weight
3 275 KV 400 500 375
condition = 0 condition = 0
Uplift condition = -800 Uplift condition = -800
(tower sudut saja) (tower sudut saja)

Tower gantung, tower Tower gantung, tower


sudut & tower ujung = sudut & tower ujung =
1500 1500
Mimimun weight Mimimun weight
4 500 KV 500 condition = 0 condition = 0 550 400
Maksimum weight Maksimum weight
condition =3000 condition = 3000
Uplift condition = -1000 Uplift condition = -1000
(tower sudut saja) (tower sudut saja)
Desain Span (Rentang) untuk
Tiang Baja / Beton
70 kV 150 kV
No Uraian satuan
Tiang Tiang Tiang Tiang
Baja Beton Baja Beton
Rentang
1 m 160 60 200 80
Dasar
Rentang
Angin :
2 -Normal m 220 80 300 100
- Kawat m 160 60 200 80
Putus
Rentang
Berat :
-Normal
m 320 120 400 160
3 - Kawat
m 240 80 300 100
Putus
Ruang bebas dan Jarak
bebas minimum pada SUTT &
SUTET
• Mengacu pada SNI 04-6918-2002.
Ruang bebas dan Jarak
bebas minimum pada SUTT &
SUTET
Ruang bebas dan Jarak
bebas minimum pada SUTT &
SUTET
Ruang bebas dan
Jarak bebas
minimum pada
SUTT & SUTET
Jarak bebas minimum
vertikal dari konduktor (c)
Jarak bebas minimum horizontal
dari sumbu vertikal menara / tiang