NOMOR : SKEP/83/VI/2005
TENTANG
MEMUTUSKAN:
KETENTUAN UMUM
Pasal 1
Pasal 2
Pasal 3
a) Localizer;
b) Glide Path;
c) Middle Marker;
d) Outer Marker.
2. Visual Aids :
Pasal 4
Pasal 5
(2) Pengujian berkala di darat sebagaimana dimaksud pada ayat (1) terdiri
dari :
a. pengukuran parameter;
b. pengukuran output.
Pasal 6
Pasal 8
Pasal 9
Pasal 10
Ditetapkan di : JAK A R T A
Pada tanggal : ___20_Juni 2005
TTD
E.A. S I L O O Y
NIP. 120108009
LAMPIRAN
PERATURAN DIREKTUR JENDERAL PERHUBUNGAN UDARA
NOMOR : SKEP/83/VI/2005
TANGGAL : 20 JUNI 2005 ________________
LAPORAN BULAN :
BANDARA :
NAMA PERALATAN : VHF-AG- ACC
LOKASI PERALATAN
FUNGSI PERALATAN
DATA TEKNIS : FREQ. =
KALIBRASI TERAKHIR : TANGGAL =
PENGUJIAN DI DARAT
HASIL TANGGAL KETERANGAN
NO. PARAMETER PENGUKURAN TOLERANSI TX1 TX2
SETELAH
KALIBRASI HASIL PD IN TOLERANCE OUT OF TOLERANCE HASIL PD INTOLERANCE OUT OF TOLERANCE
TRANSMITTER
a. Power P.Comm'-3 dB
b. Modulation (TX) 90 5%
RECEIVER
a. Squelch On
b. Audio Distortion
CONSOLE
a. Intercom Unit
b. Manual Changeover Unit (Main Standby)
c. Headset menyatu dengan Microphone
d. Hand Microphone/Microphone Meja
e. PTT Foot Switch (saklar PTT injak)
f. Audio Control Unit/Monitor Unit (Loudspeaker)
g. Clock display
h. Lampu meja operator / Dimmer
i. Interconnection (connector, cable)
j. Indicator Lamp
k. Antenna System
l. Recording
m. Fungsi extended range
n. Interference clear
o. Hot Line (Direct Speech)
TEKNISI PELAKSANA
PIMPINAN TEKNISI
( )
Halaman 1 / 5
PENGUJIAN BERKALA DI DARAT
PERALATAN FASLEKTRIK PENERBANGAN
LAPORAN BULAN :
BANDARA :
NAMA PERALATAN : VHF-AG- APP
LOKASI PERALATAN
FUNGSI PERALATAN
DATA TEKNIS : FREQ. =
KALIBRASI TERAKHIR : TANGGAL =
PENGUJIAN DI DARAT
HASIL TANGGAL KETERANGAN
NO. PARAMETER PENGUKURAN TOLERANSI TX1 TX2
SETELAH OUT OF OUT OF
KALIBRASI HASIL PD IN TOLERANCE HASIL PD IN TOLERANCE
TOLERANCE TOLERANCE
TRANSMITTER
a. Power P.Comm'-3 dB
b. Modulation (TX) 90 5%
RECEIVER
a. Squelch On
b. Audio Distortion
CONSOLE
a. Intercom Unit
b. Manual Changeover Unit (Main Standby)
c. Wind Speed (Kecepatan Angin) Indikator
d. Wind Direction (Arah Angin) Indikator
e. Temperature (Suhu) Indikator
f. Tekanan Udara (Pressure) Indikator *
g. Headset menyatu dengan Microphone
h. Hand Microphone/Microphone Meja
i. PTT Foot Switch (saklar PTT injak)
j. Audio Control Unit/Monitor Unit (Loudspeaker)
k. Clock display
l. Lampu meja operator / Dimmer
m. Interconnection (connector, cable)
n. Indicator Lamp
o. Antenna System
p. Recording
q. Nav Aid monitor *
r. Interference clear
d. Hot Line (Direct Speech)
TEKNISI PELAKSANA
PIMPINAN TEKNISI
( )
Halaman 2 / 5
PENGUJIAN BERKALA DI DARAT
PERALATAN FASLEKTRIK PENERBANGAN
LAPORAN BULAN :
BANDARA :
NAMA PERALATAN : RDARA-MWARA
LOKASI PERALATAN :
FUNGSI PERALATAN :
DATA TEKNIS : FREQUENCY.
CHANEL 1
CHANEL 2
CHANEL 3
CHANEL 4
CHANEL 5
CHANEL 6
KALIBRASI TERAKHIR : TANGGAL =
PENGUJIAN DI DARAT
HASIL TANGGAL
NO. PARAMETER PENGUKURAN TOLERANSI TX1 TX2 KETERANGAN
SETELAH OUT OF HASIL IN OUT OF
HASIL PD IN TOLERANCE
KALIBRASI TOLERANCE PD TOLERANCE TOLERANCE
Transmitter
a. Power - 3 dB
b. Modulation 90% 10%
Receiver
a. Squelch On
- Channel 1
- Channel 2
- Channel 3
- Channel 4
- Channel 5
- Channel 6
b. Audio Distortion
- Channel 1
- Channel 2
- Channel 3
- Channel 4
- Channel 5
- Channel 6
c. Antena system
d. Console
- Intercom Unit
- Manual Changeover Unit (Main Standby)
- Fungsi Channel Selector
- Selcall Unit
- Headset menyatu dengan Microphone
Halaman 3 / 5
PENGUJIAN DI DARAT
HASIL TANGGAL
NO. PARAMETER PENGUKURAN TOLERANSI TX1 TX2 KETERANGAN
SETELAH OUT OF HASIL IN OUT OF
HASIL PD IN TOLERANCE
KALIBRASI TOLERANCE PD TOLERANCE TOLERANCE
- Hand Microphone/Microphone Meja
- PTT Foot Switch (saklar PTT injak)
- Audio Control Unit/Monitor Unit
- Master Clock Console (Jam)
- Interconnection (connector, cable)
- Lampu meja operator / Dimmer
- Indicator Lamp/metering
f. Recorder
g. Tranmisi ke Tx/Rx
h. Channel Interference
- Channel 1
- Channel 2
- Channel 3
- Channel 4
- Channel 5
- Channel 6
TEKNISI PELAKSANA
PIMPINAN TEKNISI
( )
Halaman 4 / 5
PENGUJIAN BERKALA DI DARAT
PERALATAN FASLEKTRIK PENERBANGAN
LAPORAN BULAN :
BANDARA :
NAMA PERALATAN : VHF-AG- ADC
LOKASI PERALATAN :
FUNGSI PERALATAN :
DATA TEKNIS : FREQ. =
KALIBRASI TERAKHIR : TANGGAL =
PENGUJIAN DIDARAT
HASIL TANGGAL
NO. PARAMETER PENGUKURAN TOLERANSI TX1 TX2 KETERANGAN
SETELAH OUT OF OUT OF
HASIL PD IN TOLERANCE HASIL PD IN TOLERANCE
KALIBRASI TOLERANCE TOLERANCE
TRANSMITTER
a. Power P.Comm'-3 dB
b. Modulation (TX) 90 5%
RECEIVER
a. Squelch On
b. Audio Distortion
CONSOLE
a. Intercom Unit
b. Manual Changeover Switch (Main Standby)
c. Wind Speed (Kecepatan Angin) Indikator
d. Wind Direction (Arah Angin) Indikator
e. Temperature (Suhu) Indikator
f. Pressure (Tekanan Udara) Indikator
g. Crass Bell Function
h. Headset menyatu dengan Microphone
i. Hand Microphone/Microphone Meja
j. PTT Foot Switch (saklar PTT injak)
k. Audio Control Unit/Monitor Unit (Loudspeaker)
l. Clock display
m. Lampu meja operator / Dimmer
n. Indicator Lamp
o. Interconnection (connector, cable)
p. Antenna System (Tx/Rx)
q. Recording
r. Nav aid monitor
s. Interference clear
t. Hot Line (Direct Speech)
TEKNISI PELAKSANA
PIMPINAN TEKNISI
( )
Halaman 5 / 5
PENGUJIAN BERKALA DI DARAT
PERALATAN FASLEKTRIK PENERBANGAN
LAPORAN BULAN :
BANDARA :
NAMA PERALATAN : MSSR
LOKASI PERALATAN :
FUNGSI PERALATAN :
DATA TEKNIS : FREQ. =
KALIBRASI TERAKHIR : TANGGAL =
PENGUJIAN DIDARAT
HASIL TANGGAL KETERANGAN
NO. PARAMETER PENGUKURAN TOLERANSI TX1 TX2
SETELAH IN OUT OF IN OUT OF
HASIL PD HASIL PD
KALIBRASI TOLERANCE TOLERANCE TOLERANCE TOLERANCE
BUILT IN TEST
A ANTENNA
1 SPEED 5 - 15 RPM
2 MECHANICAL :
ANTENNA DRIVER
ANTENNA MOUNTING
3 DRIVER CONTROL
4 DOOR SAFETY SYSTEM
5 AIR DRYER
6 NORTH SIGNAL 1 PULSE / RPM
7 ENCODER CHANGE OVER
B MSSR PROCESSOR
1 TEST PLOT 1 dan 16
D TRANSMISSION DATA
MEDIA TRANSMISION
a. LEAST CHANNEL
b. V S A T
c. OPTIC CABLE
d. COAXIAL CABLE
e. DATA CABLE
f. RADIO LINK
E PILOT LAMP / METERING
F INTERCONNECTION
A/L TGL.:
TEKNISI PELAKSANA
PIMPINAN TEKNISI
( )
Halaman 1 / 1
PENGUJIAN BERKALA DI DARAT
PERALATAN FASLEKTRIK PENERBANGAN
LAPORAN BULAN :
BANDARA :
NAMA PERALATAN : RADAR DISPLAY
LOKASI PERALATAN :
FUNGSI PERALATAN :
DATA TEKNIS :
KALIBRASI TERAKHIR : TANGGAL =
PENGUJIAN DI DARAT
HASIL
TANGGAL :
PENGUKURA
NO KRITERIA PENILAIAN TOLERANSI DISPLAY 1 DISPLAY 2 DISPLAY3 DISPLAY 4 KETERANGAN
N SETELAH
HASIL HASIL HASIL
KALIBRASI HASIL PD
IN OUT PD IN OUT PD IN OUT PD IN OUT
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
BUILT IN TEST
1 RADAR DISPLAY
a. RAW VIDEO
b. SYNTHETIC VIDEO
c. MAPPING
d. KEYBOARD
e. MODE SELECTION
f. ROLLING BALL
g. CONTROL SWITCH
h. RANGE MARKER
i. MAX RANGE DETECTION
j. MIN RANGE DETECTION
k. TEST PLOT PSR
l. TEST PLOT SSR
m. ZOOMING / SCALE EXP
2 PILOT LAMP / METERING
3 INTERCONNECTION
TEKNISI PELAKSANA
PIMPINAN TEKNISI
( )
Halaman 1 / 1
PENGUJIAN BERKALA DI DARAT
PERALATAN FASLEKTRIK PENERBANGAN
LAPORAN BULAN :
BANDARA :
NAMA PERALATAN : SSR
LOKASI PERALATAN :
FUNGSI PERALATAN :
DATA TEKNIS : FREQ. =
KALIBRASI TERAKHIR : TANGGAL =
PENGUJIAN DIDARAT
HASIL TANGGAL KETERANGAN
NO. PARAMETER PENGUKURAN TOLERANSI TX1 TX2
SETELAH IN OUT OF IN OUT OF
HASIL PD HASIL PD
KALIBRASI TOLERANCE TOLERANCE TOLERANCE TOLERANCE
BUILT IN TEST
A ANTENNA
1 SPEED 5 - 15 RPM
2 MECHANICAL :
ANTENNA DRIVER
ANTENNA MOUNTING
3 DRIVER CONTROL
4 DOOR SAFETY SYSTEM
5 AIR DRYER
6 NORTH SIGNAL 1 PULSE / RPM
7 ENCODER CHANGE OVER
B PROCESSING SECONDARY
1 TEST PLOT 1 dan 16
C TRANSMISSION DATA
MEDIA TRANSMISION
a. LEAST CHANNEL
b. V S A T
c. OPTIC CABLE
d. COAXIAL CABLE
e. DATA CABLE
f. RADIO LINK
D PILOT LAMP / METERING
E INTERCONNECTION
A/L TGL.:
TEKNISI PELAKSANA
PIMPINAN TEKNISI
( )
Halaman 1 / 1
PENGUJIAN BERKALA DI DARAT
PERALATAN FASLEKTRIK PENERBANGAN
LAPORAN BULAN :
BANDARA :
NAMA PERALATAN : PSR
LOKASI PERALATAN :
FUNGSI PERALATAN :
DATA TEKNIS : FREQ. =
KALIBRASI TERAKHIR : TANGGAL =
PENGUJIAN DIDARAT
HASIL TANGGAL KETERANGAN
NO. PARAMETER PENGUKURAN TOLERANSI TX1 TX2
SETELAH
IN OUT OF IN OUT OF
KALIBRASI HASIL PD HASIL PD
TOLERANCE TOLERANCE TOLERANCE TOLERANCE
BUILT IN TEST
A ANTENNA
1 SPEED 5 - 15 RPM
2 MECHANICAL
ANTENNA DRIVER
ANTENNA MOUNTING
3 DRIVER CONTROL
4 DOOR SAFETY SYSTEM
5 AIR DRYER
6 NORTH SIGNAL/ROTASION 1 PULSE
7 ENCODER CHANGE OVER
B TRANSMITTER
1 EXTRA HIGH TENSION 5 - 15 kV
2 EHT CURRENT 650 - 800 mA
3 MAGNETRON /KLYSTRON CURRENT
4 MAGNETRON PULSE 1.2 uS
5 PULSE REPETITION FREQUENCY 340 - 750
6 MAGNETRON FILAMENT VOLTAGE 24 V
7 MAGNETRON COOLING SYSTEM
8 MANUAL / AUTO OPERATION
C RECEIVER
1 AFC
AUTO
MANUAL
2 HIGH / LOW COVERAGE CONTROL
Halaman 1 / 2
PENGUJIAN DIDARAT
HASIL TANGGAL KETERANGAN
NO. PARAMETER PENGUKURAN TOLERANSI TX1 TX2
SETELAH
IN OUT OF IN OUT OF
KALIBRASI HASIL PD HASIL PD
TOLERANCE TOLERANCE TOLERANCE TOLERANCE
D PROCESSING PRIMARY
1 SYNCHRONIZATION / TRIGERING
2 WOBULATION
3 STAGGERING
4 DIFFERSITY
5 NORMAL VIDEO
6 MTI VIDEO
7 TEST PLOT 1 DAN 16
E TRACK PROCESSING
1 OPERATION MAINTENACE MODE
2 SELF DIAGNOSTIC TEST
G TRANSMISSION DATA
MEDIA TRANSMISSION
1. LEAST CHANNEL
2. V S A T
3. OPTIC CABLE
4. COAXCABLE
5. DATA CABLE
6.RADIO LINK
TEKNISI PELAKSANA
PIMPINAN TEKNISI
( )
Halaman 2 / 2
PENGUJIAN BERKALA DI DARAT
PERALATAN FASLEKTRIK PENERBANGAN
LAPORAN BULAN :
BANDARA ;
NAM,A PERALATAN : DME
LOKASI PERALATAN :
FUNGSI PERALATAN :
DATA TEKNIS : FREQ. =
KALIBRASI TERAKHIR : TANGGAL =
PENGUJIAN DIDARAT
HASIL TANGGAL KETERANGAN
NO. PARAMETER PENGUKURAN TOLERANSI TX1 TX2
SETELAH KALIBRASI OUT OF IN OUT OF
HASIL PD IN TOLERANCE HASIL PD
TOLERANCE TOLERANCE TOLERANCE
BUILT IN TEST
1 Peak power output 1 dB from Nom.
2 Pulse spacing
X - Channel 12 0.25 s
Y - Channel 30 0.25 s
3 Variation of peak power in any pair of pulse < 1 dB
4 Pulse repetition frequency (PRF) > 700 pps
5 Time delay
X - Channel 50 uS 1,0 uS
Y - Channel 56 uS 1,0 uS
6 Identification clear
Pulse pair 1350 pulse
7 Monitor Action
Monitor Alarm when reply delay Monitor Alarm when reply
more than 1 s ( 0,5s for DME delay more than 1 s ( 0,5s
assosiated with landing aids) for DME assosiated with
landing aids)
TEKNISI PELAKSANA
PIMPINAN TEKNISI
( )
Halaman1 / 1
PENGUJIAN BERKALA DI DARAT
PERALATAN FASLEKTRIK PENERBANGAN
LAPORAN BULAN :
BANDARA :
NAMA PERALATAN : VOR
LOKASI PERALATAN :
FUNGSI PERALATAN :
DATA TEKNIS : FREQ. = IDENTIFICATION
KALIBRASI TERAKHIR : TANGGAL =
BUILT IN TEST
1 FORWARD POWER (COVERAGE) 3dB down
2 REVERSE POWER 5%
3 IDENTIFICATION SPEED 7 words/minute
4 IDENTIFICATION REPETITION 2 times/min
5 FORWARD UPPER SIDE BAND POWER 3dB down
6 FORWARD LOWER SIDE BAND POWER 3dB down
7 MONITOR
BEARING
MODULATION
8 MANUAL CHANGE OVER SWITCH
9 INTERKONEKSI
10 CHANGE OVER TIME
11 INDICATOR LAMP & METERING
12 REMOTE MONITORING
TEKNISI PELAKSANA
PIMPINAN TEKNISI
( )
Halaman 1 / 1
PENGUJIAN BERKALA DI DARAT
PERALATAN FASLEKTRIK PENERBANGAN
LAPORAN BULAN :
BANDARA :
NAMA PERALATAN : NDB
LOKASI PERALATAN
FUNGSI PERALATAN
DATA TEKNIS : FREQ. = LR/MR/HR IDENTIFICATION
KALIBRASI TERAKHIR : TANGGAL =
PENGUJIAN DIDARAT
HASIL TANGGAL KETERANGAN
NO. PARAMETER PENGUKURAN TOLERANSI TX1 TX2
SETELAH IN OUT OF IN OUT OF
HASIL PD HASIL PD
KALIBRASI TOLERANCE TOLERANCE TOLERANCE TOLERANCE
BUILT IN TEST
1 FORWARD POWER NOM (3 dB down)
2 REFLECTED POWER 5%
3 MODULATION DEPTH 90% 5%
4 MANUAL CHANGE OVER
5 AUTOMATIC TUNING UNIT (ATU)
6 INTERKONEKSI
7 CHANGE OVER TIME 15 seconds
8 INDICATOR LAMP & METERING
9 MONITORING
10 IDENTIFICATION CLEAR
TEKNISI PELAKSANA
PIMPINAN TEKNISI
( )
Halaman 1 / 1
PENGUJIAN BERKALA DI DARAT
PERALATAN FASLEKTRIK PENERBANGAN
LAPORAN BULAN :
BANDARA :
NAMA PERALATAN : ILS LOCALIZER
LOKASI PERALATAN :
FUNGSI PERALATAN :
DATA TEKNIS : FREQ. = IDENTIFICATION
KALIBRASI TERAKHIR : TANGGAL =
1 PARAMETER PERALATAN
BUILT IN TEST
1 RF POWER LEVEL POUT (Commissioning) - 3 db
2 COURSE ALIGNMENT 0.0000 DDM 0,0015 DDM
3 DEPTH OF MODULATION 20% 2%
4 SUM OF MODULATION DEPTHS 40% 4%
5 IDENTIFICATION MODULATION DEPTH 10% + 5%
6 MONITORING :
- COURSE SHIFT 10.5 M
- CHANGE IN DISPLACEMENT 0.17
SENSITIFITY
- CLEARANCE SIGNAL 150 A
- TOTAL TIME OF OUT OF TOLERANCE 10 s
RADIATION
- REDUCTION IN POWER -3 dB dari Comm
7 INTERCONECTION
8 ANTENA
9 CHANGE OVER ( MAIN TO STANDBY ) 10 s
10 INDICATOR LAMP & METERING
11 REMOTE CONTROL AND MONITORING
ADDITIONAL TEST EQUIPMENT
1 RF POWER LEVEL Field strength Comm - 3 db
2 COURSE ALIGNMENT <10,5 meter (35 ft)
3 DISPLACEMENT SENSITIVITY 0,00145 DDM/m 17%
4 SPURIOUS MODULATION <0,005 DDM peak to peak
5 DEPTH OF MODULATION 20% 2%
6 SUM OF MODULATION DEPTHS Modulation depth <95%
7 ORIENTATION Correct
8 FREQUENCY Single frequency : 0.005%
Dual frequency : 0.002%
5kHz < Diff. < 14 kHz
9 CARRIER MODULATION FREQUENCY 2.5%
10 IDENTIFICATION TONE FREQUENCY 1020 50Hz
11 IDENTIFICATION MODULATION DEPTH 10% + 5%
Halaman 1 /2
PENGUJIAN DI DARAT PENGUJIAN DI DARAT
HASIL TANGGAL TANGGAL
NO. PARAMETER PENGUKURAN TOLERANSI TX1 TX2 TX1 TX2
KETERANGAN
SETELAH
KALIBRASI OUT OF OUT OF OUT OF OUT OF
HASIL PD IN TOLERANCE HASIL PD IN TOLERANCE HASIL PD IN TOLERANCE HASIL PD IN TOLERANCE
TOLERANCE TOLERANCE TOLERANCE TOLERANCE
TEKNISI PELAKSANA
PIMPINAN TEKNISI
( )
Halaman 2 /2
PENGUJIAN BERKALA DI DARAT
PERALATAN FASLEKTRIK PENERBANGAN
LAPORAN BULAN :
BANDARA :
NAMA PERALATAN : ILS GLIDE PATH
LOKASI PERALATAN :
FUNGSI PERALATAN :
DATA TEKNIS : FREQ. =
KALIBRASI TERAKHIR : TANGGAL =
6 INTERCONECTION
7 ANTENA
8 CHANGE OVER ( MAIN TO STANDBY ) 10 s
9 INDICATOR LAMP&METERING
10 REMOTE CONTROL AND MONITORING
SYSTEM
ADDITIONAL TEST EQUIPMENT
1 RF POWER LEVEL Field strength Comm - 3 db
2 PATH ALIGNMENT 0.000 DDM 0.055 DDM
3 PATH WIDTH 0.175 DDM 0.050 DDM
4 DEPTH OF MODULATION 40% 2,5%
Halaman 1 / 2
PENGUJIAN DI DARAT PENGUJIAN DI DARAT
HASIL TANGGAL TANGGAL
NO. PARAMETER PENGUKURAN TOLERANSI TX1 TX2 TX1 TX2 KETERANGAN
SETELAH OUT OF OUT OF OUT OF OUT OF
HASIL PD IN TOLERANCE HASIL PD IN TOLERANCE HASIL PD IN TOLERANCE HASIL PD IN TOLERANCE
KALIBRASI TOLERANCE TOLERANCE TOLERANCE TOLERANCE
5 SUM OF DEPTH OF MODULATION 80 % 5 %
(90 Hz + 150 Hz)
6 ORIENTATION Correct
7 FREQUENCY Single : 0.005%
Dual : 0.002%
4kHz < Diff.<32kHz
8 CARRIER MODULATION FREQUENCY 2.5%
TEKNISI PELAKSANA
PIMPINAN TEKNISI
( )
Halaman 2 / 2
PENGUJIAN BERKALA DI DARAT
PERALATAN FASLEKTRIK PENERBANGAN
LAPORAN BULAN :
BANDARA ;
NAM,A PERALATAN : ILS MIDDLE MARKER
LOKASI PERALATAN :
FUNGSI PERALATAN :
DATA TEKNIS : FREQ. =
KALIBRASI TERAKHIR : TANGGAL =
TEKNISI PELAKSANA
PIMPINAN TEKNISI
( )
Halaman 1 / 1
PENGUJIAN BERKALA DI DARAT
PERALATAN FASLEKTRIK PENERBANGAN
LAPORAN BULAN :
BANDARA ;
NAM,A PERALATAN : ILS OUTER MARKER
LOKASI PERALATAN :
FUNGSI PERALATAN :
DATA TEKNIS : FREQ. =
KALIBRASI TERAKHIR : TANGGAL =
TEKNISI PELAKSANA
PIMPINAN TEKNISI
( )
Halaman 1 / 1
PENGUJIAN BERKALA DI DARAT
PERALATAN FASLEKTRIK PENERBANGAN
LAPORAN BULAN :
BANDARA :
NAMA PERALATAN : FLASHING
LOKASI PERALATAN : R/W
FUNGSI PERALATAN :
DATA TEKNIS : ODALS/SQFL/RTIL/LIL
KALIBRASI TERAKHIR : TANGGAL =
TEKNISI PELAKSANA
PIMPINAN TEKNISI
( )
Halaman 1 / 1
PENGUJIAN BERKALA DI DARAT
PERALATAN FASLEKTRIK PENERBANGAN
LAPORAN BULAN :
BANDARA :
NAMA PERALATAN : APPROACH LIGHT
LOKASI PERALATAN : R/W
FUNGSI PERALATAN :
DATA TEKNIS : SALS/MALS/PALS (FULL/TESTRICTED )
KALIBRASI TERAKHIR : TANGGAL =
Halaman 1 / 2
HASIL PENGUJIAN DI DARAT
PENGUKURAN TOLERANSI TGL
NO. PARAMETER KETERANGAN
SETELAH
HASIL PD IN TOLERANCE OUT OF TOLERANCE
KALIBRASI
4. POWER SUPPLAY
CCR1
CCR2
CCR3
CCR4
5 INTERCONNECTION
6 INDICATOR LAMP / METERING
TEKNISI PELAKSANA
PIMPINAN TEKNISI
( )
Halaman 2 / 2
PENGUJIAN BERKALA DI DARAT
PERALATAN FASLEKTRIK PENERBANGAN
LAPORAN BULAN :
BANDARA :
NAMA PERALATAN : PAPI
LOKASI PERALATAN : R/W
FUNGSI PERALATAN :
DATA TEKNIS : PAPI/ APAPI
KALIBRASI TERAKHIR : TANGGAL =
2. OPERASI
LOKAL
REMOTE
3 TAHANAN ISOLASI
CIRCUIT 1 Min 1 M ohm
CIRCUIT 2 Min 1 M ohm
CONTINUITY
CIRCUIT 1
CIRCUIT 2
Halaman 1 / 2
HASIL PENGUJIAN DI DARAT
PENGUKURAN TOLERANSI TGL
NO. PARAMETER KETERANGAN
SETELAH
HASIL PD IN TOLERANCE OUT OF TOLERANCE
KALIBRASI
4 POWER SUPPLAY
CCR1
CCR2
SELECTOR CABINET1
SELECTOR CABINET 2
5 INTERCONNECTION
6 INDICATOR LAMP/METERING
TEKNISI PELAKSANA
PIMPINAN TEKNISI
( )
Halaman 2 / 2
PENGUJIAN BERKALA DI DARAT
PERALATAN FASLEKTRIK PENERBANGAN
LAPORAN BULAN :
BANDARA :
NAM,A PERALATAN : VASI
LOKASI PERALATAN : R/W
FUNGSI PERALATAN :
DATA TEKNIS : 2BAR /3BAR
KALIBRASI TERAKHIR : TANGGAL =
2. OPERASI
LOKAL
REMOTE
3 TAHANAN ISOLASI
CIRCUIT 1 Min 1 M ohm
CIRCUIT 2 Min 1 M ohm
CONTINUITY
CIRCUIT 1
CIRCUIT 2
4 POWER SUPPLAY
CCR1
CCR2
Halaman 1 / 2
HASIL PENGUJIAN DI DARAT
PENGUKURAN TOLERANSI TGL
NO. PARAMETER KETERANGAN
SETELAH
HASIL PD IN TOLERANCE OUT OF TOLERANCE
KALIBRASI
SELECTOR CABINET1
SELECTOR CABINET 2
5 INTERCONNECTION
6 INDICATOR LAMP/METERING
TEKNISI PELAKSANA
PIMPINAN TEKNISI
( )
Halaman 2 / 2
PENGUJIAN BERKALA DI DARAT
PERALATAN FASLEKTRIK PENERBANGAN
LAPORAN BULAN :
BANDARA :
NAMA PERALATAN : THRESHOLD LIGHT
LOKASI PERALATAN : R/W
FUNGSI PERALATAN :
DATA TEKNIS : MI/HI
KALIBRASI TERAKHIR : TANGGAL =
6 POWER SUPPLAY
CCR1
CCR2
CCR3
CCR4
7 INTERCONNECTION
8 INDICATOR LAMP/METERING
TEKNISI PELAKSANA
PIMPINAN TEKNISI
( )
Halaman 2 / 2
PENGUJIAN BERKALA DI DARAT
PERALATAN FASLEKTRIK PENERBANGAN
LAPORAN BULAN :
BANDARA :
NAMA PERALATAN : RUNWAY LIGHT
LOKASI PERALATAN :
FUNGSI PERALATAN :
DATA TEKNIS : WATTAGE LAMPU
- R/W EDGE LIGHT : WATT
- T/A LIGHT : WATT
- R/W C/L LIGHT : WATT
KALIBRASI TERAKHIR : TANGGAL =
Halaman 1/ 2
HASIL PENGUJIAN DI DARAT
PENGUKURAN TOLERANSI TGL
NO. PARAMETER KETERANGAN
SETELAH
HASIL PD IN TOLERANCE OUT OF TOLERANCE
KALIBRASI
CIRCUIT 5
- LOKAL
- REMOTE
5 TAHANAN ISOLASI
CIRCUIT 1 Min 1 M ohm
CIRCUIT 2 Min 1 M ohm
CIRCUIT 3 Min 1 M ohm
CIRCUIT 4 Min 1 M ohm
CIRCUIT 5 Min 1 M ohm
CONTINUITY
CIRCUIT 1
CIRCUIT 2
CIRCUIT 3
CIRCUIT 4
CIRCUIT 5
6 POWER SUPPLAY
CCR1
CCR2
CCR3
CCR4
CCR5
7 INTERCONNECTION
8 INDICATOR LAMP/METERING
TEKNISI PELAKSANA
PIMPINAN TEKNISI
( )
Halaman 2/ 2
PENGUJIAN BERKALA DI DARAT
PERALATAN FASLEKTRIK PENERBANGAN
LAPORAN BULAN :
BANDARA :
NAMA PERALATAN : ILLUMINATED WIND CONE
LOKASI PERALATAN :
FUNGSI PERALATAN :
DATA TEKNIS : WATTAGE LAMPU
KALIBRASI TERAKHIR : TANGGAL =
TEKNISI PELAKSANA
PIMPINAN TEKNISI
( )
Halaman 1/1
PENGUJIAN BERKALA DI DARAT
PERALATAN FASLEKTRIK PENERBANGAN
LAPORAN BULAN :
BANDARA :
NAMA PERALATAN : OBSTRUCTION LIGHT ( DI DAERAH KKOP)
LOKASI PERALATAN :
FUNGSI PERALATAN :
DATA TEKNIS : WATTAGE LAMPU
KALIBRASI TERAKHIR : TANGGAL =
1 OBSTRUCTION LIGHT
JUMLAH LAMPU HIGH INTENSITY
JUMLAH LAMPU MEDIUM INTENSITY
JUMLAH LAMPU LOW INTENSITY
2 OPERASI
MANUAL
AUTO
3 KONSTRUKSI PENEMPATAN
4 INTERCONECTION
TEKNISI PELAKSANA
PIMPINAN TEKNISI
( )
Halaman 1/1
PENGUJIAN BERKALA DI DARAT
PERALATAN FASLEKTRIK PENERBANGAN
LAPORAN BULAN :
BANDARA :
NAMA PERALATAN : ROTATING BEACON
LOKASI PERALATAN :
FUNGSI PERALATAN :
DATA TEKNIS : WATTAGE LAMPU
KALIBRASI TERAKHIR : TANGGAL =
TEKNISI PELAKSANA
PIMPINAN TEKNISI
( )
ttd
E.A. SILOOY
NIP. 120108009
Halaman 1/1