LC-1
LC-2
= ( π /4 × D t 2 × H) + (π/12× Dt 3)
Dimana:
H = (3/2) ×Dt
h = (1/4) ×Dt (Perry’s Chem.Eng, Tabel 6-51)
maka,p
V t ×8
Dt =
√ 3
3×π
464,10 ×8
=
√ 3
3 x 3,14
= 9,58 m
= 29,49 ft
b. Volume Ellipsoidal, Ve
Ve = π/24 × Dt3
= 0,13× (9,58)3
= 114,94 m3
= 3.354,82 ft3
c. Volume Silinder, Vs
Vs = Vt – Ve
= (464,10– 114,94) m3
= 349,17 m3
= 26.838,57 ft3
d. Tinggi Tangki Total, Ht
Tinggi slinder,
H = (3/2) ×Dt
= (3/2) ×9,58 m
= 14,37 m
= 4,38 ft
Tinggi ellipsoidal,
H = (1/4) ×Dt
= (1/4) × 9,58 m
= 2,39 m
LC-3
= 0,73 ft
Maka,
Ht = H + h
= (14,37 + 2,39) m
= 16,76 m
= 5,11 ft
3. Tekanan design
Pabs = Poperasi + Phidrostatis
ρ× h−1
Phidrostatis = ( )
144
= 9,16 Psi
Poperasi = 1Atm
= 14,7 Psi
Pabs = (9,16 + 14,7 ) Psi
= 23,86 Psi
Pdesain = 20,69 Psi
OD = 2t + D
= 2 (0,02) + 9,58
= 9,62 m
= 351,62 in
= 29,30 ft
Tabel C.1 Spesifikasi Tangki Isopropil Alkohol
Fungsi Menyimpan bahan baku Isopropil Alkoholdalam fase
liquid
Bentuk Silinder vertical dengan tutupthorispherical
Kapasitas 4.162,83 kg/jam
Dimensi Diameter (D) = 7,3319 m = 29,4883 ft
Tinggi (Ht) = 12,8310 m = 3,9109 ft
Tebal dinding = 0,7188 in = 0,0599 ft
Tekanan Desain 23,89 psi
Bahan Konstruksi Carbon Steel SA 283 Grade C
lb
8.352, 27 x 7 hari x 24 jam/hari
Jam
V =
lb
48,92
ft 3
V = 28.682,26 ft3
= 811,71 m3
LC-6
3×π
974,05 ×8
=
√ 3
3 x 3,14
= 9,39 m
= 29,49 ft
b. Volume Ellipsoidal, Ve
Ve = π/24 × Dt3
= 0,13× (9,39)3
= 108,23 m3
= 3.354,82 ft3
c. Volume Silinder, Vs
Vs = Vt – Ve
= (974,05 – 108,23) m3
= 865,82 m3
= 26.838,57 ft3
LC-7
3. Tekanan design
Pabs = Poperasi + Phidrostatis
ρ× h−1
Phidrostatis = ( )
144
= 3,89 Psi
Poperasi = 1Atm
= 14,7 Psi
Pabs = (3,89 + 14,7 ) Psi
= 18,59 Psi
Pdesain = 20,45 Psi
Dimana,
P = tekanan desain = 20,45 Psi
D = diameter tangki = 9,39 m
S = working stress yang diizinkan = 13700 psi = 931,9728 atm
E = effisiensi pengelasan = 0,85
C = korosi yang diizinkan = 0,0032 m
Maka,
2 0,45 psi x 9,39 m
t= + 0,0032 m
( 13700 psi x 0,85 ) x (0,2 x 57,8069 psi)
t = 0,02 m
OD = 2t + D
= 2 (0,02) + 9,39
= 9,43 m
= 351,62 in
= 29,30 ft
Tabel C.2 Spesifikasi Tangki Aseton
Fungsi Menyimpan produk Asetondalam fase liquid
Bentuk Silinder vertical dengan tutupthorispherical
Kapasitas 3.787,88kg/jam
Dimensi Diameter (D) = 9,3873 m =30,7858 ft
Tinggi (Ht) = 16,4277 m =5,0072 ft
Tebal dinding = 0,7188 in = 0,0646 ft
Tekanan Desain 20,45 psi
Bahan Konstruksi Carbon Steel SA 283 Grade C
( T1-t2 ) -(T2-t1)
ΔT LMTD =
ln (T1-t2)/(T2-t1)
( 302-212 ) -(122-86)
=
ln (302-212)/(122-86)
54
=
3,99
= 13,54oF
Tav =212 oC
tav = 192 oC
b. Menentukan Harga Koefisien Perpindahan Panas Keseluruhan
Untuk fluida dingin berupa Isopropil Alkohol dan fluida panas
steammemiliki UD 55 Btu/ft2oF jam. Diambil UD 55 Btu/ft2oF jam.
c. Memilih Jenis Ukuran Pipa
Dari tabel 10 Kern dipilih pipa dengan kriteria:
OD = 1 in
BWG = 18 BWG
ID = 0,902 in
att = 0,639 in2
ao = 0,2618 ft2
L
= 16 ft
d. Menentukan Luas Perpindahan Panas
413.751,70Btu/jam
Q
A= = Btu =555,71 ft2
UD.ΔTLMTD 55 .53,46F
jam
e. Menghitung Jumlah Tube
A 555,71 ft²
Nt = =
L.a ¿ 16 ft x 0,2618 ft²/ft
= 133 buah
LC-11
Dipilih jumlah tube dari tabel 9 Kern sebanyak 133 buah, dengan spesifikasi:
OD tube = 1in
Pitch = 1,25 square pitch
Passes =4
f. Koreksi harga UD
Aterkoreksi = Nt x a” x L
= 133 x 0,2618 ft2/ft x 16 ft
= 557,11ft2
Q
UDterkoreksi =
Aterkoreksi x ΔT LMTD
413.751,47 Btu/Jam
=
557,11 ft² x 13,54 F
= 55Btu/Jam Ft2 F
g. Fluida Dingin (Tube)
Flow area tube, a’t = 0,639 in2
Nt x a't
at =
144 x n
133 x 0,639 in²
=
144 x 4
= 0,15 ft2
Kecepatan Massa
9179,04 lb/jam
Gt =
0,15 ft
= 62211,02 lbm/jam ft2
Bilangan Reynold
Pada tav 192oF di peroleh data :
µ = 0,45 cP = 1,09 lb/jam.Ft
De = 0,902 in
Dc = 0,0752 ft
Dc x Gt
Ret =
µ
0,0752 ft x 62.211,02 lbm/jam ft²
=
1,09 lbm/jam.ft
LC-12
= 10.391,54
Menentukan hiodan ho
jH = 20
C = 0,85 Btu/lbm F
K = 0,095 Btu/hr (Ft2)(F/Ft)
1/3
k cxµ
hio = jh ( )x
De k ( )
1/3
0,095 Btu/hr (Ft ² )(F/Ft) 0,85 Btu/lbm x 0,05 cP
= 20 (
0,0752 Ft
)x(0,095 Btu/hr (Ft ² )(F/Ft) )
= 30,6 Btu/jam FtoF
ho
ho = ( ) x Øt
Øt
= 300,99
h. Fluida Panas pada Shell
Flow Area pada Shell, as
ID x C' x B 21,25 x (1,25-1)' x (0,25x21,25
as = ( ) =( )
PT 1,25
= 0,16 ft2
Kecepatan Massa
W 561,04 lbm/jam
Gs = ( ) =( )
as 0,16 ft ²
= 58.542,60 lbm/jam Ft2
Bilangan Reynold
µ = 0,26 cP = 0,63 lb/jam.Ft
De = 0,99 in
Dc = 0,99/12 = 0,0825 ft
Dc x Gs
Res = ( )
µ
0,0825 ft x 58.542,6 lbm/jam.ft ²
=
0, 63lbm/jam.ft
= 7.678,93
LC-13
= 195,22 Btu/(hr)(ft2)(F)
j. Menghitung Dirt Factor, Rd
1 1
=
Ud Uc
+ Rd
Uc - Ud
Rd =
Uc × Ud
195,22 - 55
=
195,22 x 55
= 0,0128
k. Menghitung Pressure Drop (ΔP)
Tube
1. Menentukan Faktor Friksi
Ret = 10.391,54 (Fig. 26, Kern,1965)
f = 0,00018 (Fig. 6, Kern,1965)
s = 0,58 (Fig. 2, Kern,1965)
Øs = 1,02
2. Menentukan Pressure Drop Tube
LC-14
f × G t2× L × n
a. ∆Pt =
5,22 × 1010 × D × s ×ϕ t
ft 2 lb
0,00 018 2
× ( 62.211,02 ) 2 × 16 × 2
= in jam.ft 2
5,22 x 10¹° x 0,0752 ft x 0,58 x 1,02
= 0,00062980 Psi
V²
= 0,04 (Fig. 27, Kern. 1965)
2g'
4n V²
b. ΔPr = ( ) x ( )
S 2g'
4x4
=(
0,58
) x 0,04
= 1,10Psi
ΔPt + ΔPr = 0,00062980 + 1,1034 Psi
= 1,10 Psi
Shell
1. Menentukan Faktor Friksi
Res = 7.678,93 (Fig. 26, Kern,1965)
f = 0,0026 (Fig. 6, Kern,1965)
s = 2,58 (Fig. 2, Kern,1965)
2. Menentukan Pressure Drop Shel
f x Gs² x (N+1)
ΔPs = ( )
5,22 x 10¹° x De x S x Øs
L
N + 1= 12 x ( )
B
16
= 12 x (
0,25 x 21,25
)
= 30,72 Ft
Ds = 30,72/12
= 2,56 ft
0,0026 x 58.542,60² lbm/jam.Ft ²x 30,72
ΔPs =( )
5,22 x 10¹° x 2,56 ft x 2,58 x 0,98
= 0,0049 Psi
LC-15
LC-16
( T1-t2 ) -(T2-t1)
a. ΔT LMTD =
ln (T1-t2)/(T2-t1)
( 842-662 ) -(572-86)
=
ln (842-662)/(572-86)
306
=
5,72
LC-17
= 53,46 oF
T 1−T 2
b. R =
t2 ‒ t 1
842-572
=
842-572
= 0,47
t2 - t1
c. S =
T 1 - t1
662-212
=
842-212
= 0,76
Dari Gambar 19 (Kern, 1965), diperoleh nilai FT = 0,65 maka,
d. Δt = FT× LMTD
Δt = 0,65 ×53,46 ℉
= 34,75oF
c. Menghitung Temperature Kalorik Tc dan tc
T1+ T2
Tc =
2
842+572
=
2
= 707 oF
t +t
tc =1 2
2
212 + 662
=
2
= 417 oC
Cek viskositas pada terminal dingin untuk tiap fluida
Tube :
Pada T = 707oF
µ = 0,05 cP (Fig. 15, Kern, 1965)
Shell :
Pada t = 417 oF
LC-18
Nt x a't
at=
144 x n
226 x 0,639 in²
=
144 x 2
=0,5 ft2
Shell
ID x C' x B 21,25 x (1,25-1)' x (0,25x21,25
as= ( )=( )
PT 1,25
=0,16 ft2
i. Menghitung Mass Velocity
Tube :
1.393,82 lb/jam
Gt =
0,5 ft
= 18.305,46 lbm/jam ft2
Shell :
W 9.179,04 lbm/jam
Gs = ( )=( )
as 0,16 ft ²
= 58.542,6 lbm/jam Ft2
j. Menghitung Bilangan Reynold Number
Tube :
Viskositas pada Tc = 707 oF
µ = 0,05 cP (Fig. 14, Kern,1965)
De = 0,902 in (Tabel. 10, Kern, 1965)
Dc = 0,0752 ft
Dc x Gt
Ret =
µ
0,0752 ft x 18.305,46 lbm/jam ft²
=
0,05 lbm/ft.jam
= 27.519,2
16 ft
L/D =
0,0 752 ft
= 212,86 ft
jH = 80 (Fig. 24, Kern,1965)
LC-21
Shell :
Viskositas pada tc = 417oF
µ = 0,28 cP (Fig. 14, Kern, 1965)
De = 0,99 in (Fig. 28, Kern, 1965)
Dc = 0,99/12 = 0,0825 ft
Dc x Gs
Res = ( )
µ
0,0825 ft x 58.542,6
=
0,28 cP
jH =17.249,16 (Fig. 28, Kern,1965)
k. Menentukan Thermal Function
Tube :
Viskositas pada Tc=707 oF
µ = 0,05 cP (Fig. 14, Kern,1965)
Kapasitas panas, Cp :
Cp = 0,128 Btu/lbm F (Fig.3, Kern,1965)
K = 0,0043 Btu/hr (Ft2)(F/Ft)
c.μ 13
Pr = ( )
k
0, 128 Btu/lb ° F× 0, 05 lb/ft.jam 1/3
=(
0, 0043 Btu/jam.lbm.ft. ° F
)
= 0,4961Btu/(hr)(ft2)(oF/ft)
Shell :
Viskositas pada tc= 414 ºF
µ = 0,28 cP (Fig. 14, Kern,1965)
Kapasitas panas, Cp :
Cp = 3,573 Btu/lbm F (Fig.3, Kern,1965)
K = 0,588 Btu/hr (Ft2)(F/Ft)
c.μ 13
Pr = ( )
k
LC-22
= 2,0052 Btu/(hr)(ft2)(oF/ft)
l. Menghitung Nilai Inside Film Coefficient (hi) dan Outside Film
Coefficient (ho)
Tube :
1
hi k c. μ
∅t
= jH
Dc ( )( k )
3
1/3
0,0043 Btu/hr (Ft ² )(F/Ft) 0,128 Btu/lbm x 0,05 cP
= 80 (
0,0752 Ft
)x(0,0043 Btu/hr (Ft ² )(F/Ft) )
= 204,8 Btu/jam Ft oF
hio hi ID
=( ) x ( )
∅t ∅t OD
= 204,80Btu/hr.ft2.oF
hi o
hi =( ) x Øt
Øt
=204,8 x 0,9363
= 218,73 Btu/hr.ft2.oF
Shell:
1/3
ho k cxµ
∅s
= jh ( )x
De k ( )
1/3
0,59 Btu/hr (Ft²)(F/Ft) 3,57 Btu/lbm x 0,28 cP
= 60 (
0,99
)x(0,59 Btu/hr (Ft²)(F/Ft) )
= 333,96 Btu/jam Ft oF
hi
ho =( ) x Øs
Øs
= 333,96 x 0,83
= 400,21Btu/hr.ft2.oF
Untuk nilai∅ t dan ∅ s diperoleh dari perhitungan tw (temperatur wall).
n. Menghitung Temperatur Wall, tw
LC-23
ho
∅s
tw = tc + (Tc - tc)
hio ho
+
∅t ∅s
2,27 Btu/hr.ft 2. ºF
= 417ºF + x (707 ºF – 417ºF)
204,8 Btu/hr.ft 2 . ºF+ 2,27 Btu/hr.ft 2. ºF
= 378,16ºF
Tube :
Pada tw = 378,16 oF
µw = 0,008 cp (Fig. 14, Kern,1965)
0 ,05 l b/ft.jam
=(
0, 008 lb/ft.jam )
0,14
= 0,94
Shell;
Pada tw = 417 ºF
µw = 0,08 cp (Fig. 14, Kern,1965)
0 ,28 l b/ft.jam
=(
0, 08 lb/ft.jam )
0,14
= 0,83
5. Menghitung Clean Overall Coeficient, Uc
h io x ho 218,73 x 400,21
Uc = =
hio + ho 218,73 + 400,21
=141,43 Btu/(hr)(ft2)(F)
6. Menghitung Dirt Factor, Rd
1 1
= + Rd
Ud Uc
Uc - Ud
Rd =
Uc × Ud
LC-24
= 5,52 Psi
ΔPt + ΔPr = 0,00005921 + 5,52 Psi
= 5,52 Psi
Shell:
1. Menentukan Faktor Friksi
Res = 12.462,52 (Fig. 26, Kern,1965)
f = 0,0026 (Fig. 6, Kern,1965)
s = 2,58 (Fig. 2, Kern,1965)
LC-25
= 30,72 Ft
Ds = 30,72/12
= 2,56 ft
0,0026 x 58.542,60² lbm/jam.Ft ²x 30,72
ΔPs = ( )
5,22 x 10¹° x 2,56 ft x 2,58 x 0,94
= 0,0053 Psi
( T1-t2 ) -(T2-t1)
a. ΔT LMTD =
ln (T1-t2)/(T2-t1)
( 662 - 194 ) -(113-86)
=
ln ( 662 - 194 ) /(113-86)
441
=
6,09
= 72,42oF
T 1−T 2
b. R =
t2 ‒ t 1
662 - 113
=
194 - 86
= 5,08
t2 - t1
c. S =
T 1 - t1
194 - 86
=
662 - 86
= 0,19
Dari Gambar 19 (Kern, 1965), diperoleh nilai FT = 0,93 maka,
d. Δt = FT× LMTD
Δt = 0,93× 72,42oF
= 67,35oF
c. Menghitung Temperature Kalorik Tc dan tc
LC-27
T1+ T2
Tc =
2
662 + 113
=
2
= 387,5oF
t +t
tc =1 2
2
86 + 194
=
2
= 183oC
Cek viskositas pada terminal dingin untuk tiap fluida
Tube :
Pada T = 387,5oF
µ = 0,179 cP (Fig. 15, Kern, 1965)
Shell :
Pada t = 183oF
µ = 0,46 cP (Fig. 15, Kern, 1965)
Karena viskositas fluida ada terminal dingin <1 cP (kern, 1965 Hal. 111), maka :
Tc = Tavg
tc = tavg
d. Memilih Jenis Alat Perpindahan Panas
Hot fluida = tube
Cold fluida = shell
Untuk fluida panas berupa light organics dipilih media pendinginnya
Dowtherm Adengan:
Range Ud = 75-150 Btu/hr.ft2oF
Ud dipilih = 75 Btu/hr.ft2oF
e. Luas Permukaan Untuk Perpindahan Panas
2.143.768,10 Btu/jam
Q
A= = Btu
UD.ΔTLMTD 75 x 72,42F
jam
=424,37 ft2
LC-28
Pada tahap pendinginan light organics, maka direncanakan tipe Shell and
Tube Heat Exchanger. Sehingga dalam perancangan ini digunakan 2-4shell and
tube heat exchanger denganspesifikasi:
Dari tabel 10 Kern dipilih pipa dengan kriteria:
Diameter luar tube, OD = 1 in
Diameter dalam tube, ID = 0,902 in
BWG = 18 BWG
at’ = 0,639 in2
a” = 0,2618 ft2
1
Pitch (PT) = 1 in trianguler pitch
4
L = 16 ft
f. Menghitung Jumlah Tube
A 424,37 ft²
Nt = =
L.a ¿ 16 ft x 0,2618 ft²/ft
= 101 buah
Q
UDterkoreksi =
Aterkoreksi x ΔT LMTD
2.143.768,10 Btu/Jam
=
423,07 ft ² x 72,42 F
=75 Btu/Jam Ft2oF
g. Analisa Kerja HE
Analisa kinerja HE meliputi :
1. Menghitung Koefisien Overall Perpindahan Panas (U)
2. Menghitung Rd
3. Menghitung ∆P
W 6.647,77 lbm/jam
Gs= ( )=( )
as 0,1 0 ft ²
= 64.341,53 lbm/jam Ft2
j. Menghitung Bilangan Reynold Number
Tube :
Viskositas pada Tc = 387,5oF
µ = 0,179 cP (Fig. 14, Kern,1965)
= 0,43 lbm/ft.jam
De = 0,902 in (Tabel. 10, Kern, 1965)
Dc = 0,0752 ft
Dc x Gt
Ret =
µ
0,0752 ft x 81.921,43 lbm/jam ft²
=
0,43 lbm/ft.jam
= 34.400,90
16 ft
L/D =
0,0 752 ft
= 212,86 ft
jH = 100 (Fig. 24, Kern,1965)
Shell :
Viskositas pada tc = 417oF
µ = 0,28 cP (Fig. 14, Kern, 1965)
= 1,11 lbm/ft.jam
De = 0,99 in (Fig. 28, Kern, 1965)
Dc = 0,99/12 = 0,0825 ft
Dc x Gs
Res = ( )
µ
0,0825 ft x 64.341,53 lbm/jam.ft ²
= 1,11 lbm/ft.jam
= 83.116,96
jH =280 (Fig. 28, Kern,1965)
k. Menentukan Thermal Function
LC-31
Tube :
Viskositas pada Tc =387,5oF
µ = 0,179 cP (Fig. 14, Kern,1965)
= 0,43 lbm/jam.ft
Kapasitas panas, Cp :
Cp = 1,88 Btu/lbm F (Fig.3, Kern,1965)
K = 0,493 Btu/hr (Ft2)(F/Ft)
c.μ 13
Pr = ( )
k
1,88 Btu/lb° F× 0,43 lb/ft.jam 1/3
=(
0, 493 Btu/jam.lbm.ft.° F
)
= 0,23 Btu/(hr)(ft2)(oF/ft)
Shell :
Viskositas pada tc= 183,0 ºF
µ = 0,46 cP (Fig. 14, Kern,1965)
= 1,1 lbm/ft.jam
Kapasitas panas, Cp :
Cp = 1,01 Btu/lbm F (Fig.3, Kern,1965)
K = 0,04 Btu/hr (Ft2)(F/Ft)
c.μ 13
Pr = ( )
k
1,01 Btu/lb ° F× 1,1 lb/ft.jam 1/3
=( )
0, 01 Btu/jam.lbm.ft. ° F
= 48,91 Btu/(hr)(ft2)(oF/ft)
l. Menghitung Nilai Inside Film Coefficient (hi) dan Outside Film
Coefficient (ho)
Tube :
hi k c . μ 13
∅t
= jH ( )(
Dc k )
1/3
0,493 Btu/hr (Ft²)(F/Ft) 1,89 Btu/lbm x 2,42 lbm/ft.jam
= 100(
0,0752 Ft
)x (
0,493 Btu/hr (Ft²)(F/Ft) )
= 124,43 Btu/jam Ft oF
LC-32
hio hi ID
= ( )x ( )
∅t ∅t OD
= 112,23Btu/hr.ft2.oF
hi o
hi =( ) x Øt
Øt
= 122,23 x 0,91
= 218,73 Btu/hr.ft2.oF
Shel l:
1/3
ho k cxµ
∅s
= jh ( )x
De k ( )
1/3
0,04 Btu/hr (Ft²)(F/Ft) 1,01 Btu/lbm x 1,11 cP
=280 (
0,99
)x (
0,04 Btu/hr (Ft²)(F/Ft) )
=397,22 Btu/jam Ft oF
hi
ho =( ) x Øs
Øs
= 333,96 x 1,04
= 397,22Btu/hr.ft2.oF
Untuk nilai∅ t dan ∅ s diperoleh dari perhitungan tw (temperatur wall).
n. Menghitung Temperatur Wall, tw
ho
∅s
tw= tc + (Tc - tc)
hio ho
+
∅t ∅s
2,27 Btu/hr.ft 2. ºF
= 183ºF + x (387,5 ºF – 183,0ºF)
204,8 Btu/hr.ft 2 . ºF+ 2,27 Btu/hr.ft 2. ºF
= 183,77ºF
Tube :
Pada tw = 183,77oF
µw = 0,34 cp (Fig. 14, Kern,1965)
= 0,82 lbm/ft.jam
= (0,43 l b/ft.jam
0, 82 lb/ft.jam )
0,14
= 0,91
Shell;
Pada tw = 417 ºF
µw= 0,08 cp (Fig. 14, Kern,1965)
= (1,11 l b/ft.jam
0,80 lb/ft.jam )
0,14
= 1,05
5. Menghitung Clean Overall Coeficient, Uc
h io x ho 397,22 x 113,74
Uc = =
hio + ho 397,22 + 113,74
=88,42 Btu/(hr)(ft2)(F)
6. Menghitung Dirt Factor, Rd
1 1
= + Rd
Ud Uc
Uc - Ud
Rd =
Uc × Ud
88,42 Btu/hr.ft ² .° F- 75 Btu/hr.Ft ² .° F
=
88,42 Btu/hr.ft ² .° F x 75 Btu/hr.Ft ² . ° F
= 0,002 Btu/hr.ft2.oF
Rd yang diperlukan = 0,001 Btu/hr.ft2.ºF (Table. 12, Kern,1965)
= 0,006177606 Psi
ΔPt + ΔPr = 0,000264898 +0,006177606 Psi
= 0,01 Psi
Shell:
1. Menentukan Faktor Friksi
Res = 201.067,28 (Fig. 26, Kern,1965)
f = 0,001 (Fig. 6, Kern,1965)
s =1 (Fig. 2, Kern,1965)
2. Menentukan Pressure Drop Shel
f x Gs² x (N+1)
ΔPs = ( )
5,22 x 10¹° x De x S x Øs
L
N + 1= 12 x ( )
B
16
= 12 x (
0,25 x 17,25
)
= 44,52 Ft
Ds = 44,52/12
= 3,71 ft
0,001 x 64.341,53² lbm/jam.Ft ²x 44,52
ΔPs = ( )
5,22 x 10¹° x 2,56 ft x 1 x 1,04
LC-35
= 0,007 Psi
ΔPs yang diperbolehkan 10 Psi
b. Menentukan ΔT LMTD
Fluida panas Fluida dingin ΔT (F)
T1 302 Temp Tinggi t2 125 177
T2 113 Temp Rendah t1 176 -37
(T1-T2) 189 (t2-t1) -15 174
( T1-t2 ) -(T2-t1)
a. ΔT LMTD =
ln (T1-t2)/(T2-t1)
LC-36
( 302-125 ) -(113-176)
=
ln (302-125)/(113-176)
138,40
=
4,93
= 28,07oF
T 1−T 2
b. R =
t2 ‒ t 1
302-113
=
125-176
= 3,73
t2 - t1
c. S =
T 1 - t1
176 - 125
=
302 - 125
= 0,29
Dari Gambar 19 (Kern, 1965), diperoleh nilai FT = 0,85 maka,
d. Δt = FT× LMTD
Δt = 0,85 × 28,07℉
= 23,86oF
c. Menghitung Temperature Kalorik Tc dan tc
T1+ T2
Tc =
2
302+113
=
2
= 207,5oF
t +t
tc = 1 2
2
125 + 176
=
2
= 213,4oC
Cek viskositas pada terminal dingin untuk tiap fluida
Tube :
Pada T = 207,5oF
LC-37
L = 16 ft
f. Menghitung Jumlah Tube
A 646,91 ft²
Nt = =
L.a ¿ 16 ft x 0,2618 ft²/ft
= 128 buah
g. Analisa Kerja HE
Analisa kinerja HE meliputi :
1. MenghitungKoefisien Overall Perpindahan Panas (U)
2. Menghitung Rd
3. Menghitung ∆P
LC-39
= 3.681,09
jH =35 (Fig. 28, Kern,1965)
k. Menentukan Thermal Function
Tube :
Viskositas pada tc =213,4oF
µ = 1,005 cP (Fig. 14, Kern,1965)
= 2,43 lbm/ft.jam
Kapasitas panas, Cp :
Cp = 1,02 Btu/lbm F (Fig.3, Kern,1965)
K = 2,51 Btu/hr (Ft2)(F/Ft)
c.μ 13
Pr = ( )
k
1,02 Btu/lb ° F× 2,43 lb/ft.jam 1/3
=( )
2,51 Btu/jam.lbm.ft. ° F
= 0,14 Btu/(hr)(ft2)(oF/ft)
LC-41
Shell :
Viskositas pada Tc= 207 ºF
µ = 0,28 cP (Fig. 14, Kern,1965)
= 0,68 lbm/ft.jam
Kapasitas panas, Cp :
Cp = 1,1 Btu/lbm F (Fig.3, Kern,1965)
K = 0,40 Btu/hr (Ft2)(F/Ft)
c.μ 13
Pr = ( )
k
1,1 Btu/lb ° F× 0, 68 lb/ft.jam 1/3
=( )
0, 40 Btu/jam.lbm.ft.° F
= 0,91 Btu/(hr)(ft2)(oF/ft)
l. Menghitung Nilai Inside Film Coefficient (hi) dan Outside Film
Coefficient (ho)
Tube :
1
hi k c. μ
∅t
= jH
Dc ( )( k )
3
1/3
2,512 Btu/hr (Ft ² )(F/Ft) 2,512 Btu/lbm x 2,43 cP
= 12(
0,0752 Ft
)x (
2,512 Btu/hr (Ft ² )(F/Ft) )
= 3,57 Btu/jam Ft oF
hio hi ID
= ( )x ( )
∅t ∅t OD
= 41,00Btu/hr.ft2.oF
hi o
hi =( ) x Øt
Øt
=204,8 x 0,90
= 166,16 Btu/hr.ft2.oF
Shel l:
1/3
ho k cxµ
∅s
= jh ( )x
De k ( )
1/3
0,40 Btu/hr (Ft²)(F/Ft) 1,1 Btu/lbm x 0,68 cP
= 35(
0,99
)x (
0,398 Btu/hr (Ft²)(F/Ft) )
LC-42
= 273,56 Btu/jam Ft oF
hi
ho =( ) x Øs
Øs
= 333,96 x 0,83
= 327,84 Btu/hr.ft2.oF
Untuk nilai∅ t dan ∅ s diperoleh dari perhitungan tw (temperatur wall).
n. Menghitung Temperatur Wall, tw
ho
∅s
tw= tc + (Tc - tc)
hio ho
+
∅t ∅s
35,65 Btu/hr.ft 2. ºF
= 207ºF + x (213,40 ºF –
41,00 Btu/hr.ft 2. ºF +35,65 Btu/hr.ft 2. ºF
207ºF)
= 110,99ºF
Tube :
Pada tw = 110,99oF
µw = 2,1 cp (Fig. 14, Kern,1965)
= 5,08 lb/ft.jam
2,43 l b/ft.jam
=(
5,08 lb/ft.jam )
0,14
= 0,90
Shell;
Pada tw = 110,99ºF
µw= 2,1 cp (Fig. 14, Kern,1965)
= 5,08 lb/ft.jam
= (0,68 l b/ft.jam
5,08 lb/ft.jam )
0,14
= 0,83
LC-43
= 0,0296 Psi
ΔPt + ΔPr = 0,0026 + 0,0296 Psi
= 0,0322 Psi
Shell:
1. Menentukan Faktor Friksi
Res = 3.681,09 (Fig. 26, Kern,1965)
f = 0,0026 (Fig. 6, Kern,1965)
s = 2,58 (Fig. 2, Kern,1965)
2. Menentukan Pressure Drop Shel
f x Gs² x (N+1)
ΔPs =( )
5,22 x 10¹° x De x S x Øs
L
N + 1 = 12 x ( )
B
16
= 12 x (
0,25 x 19,25
)
= 24,93 Ft
Ds = 24,93/12
= 2,08 ft
0,0026 x 30.222,62² lbm/jam.Ft ²x 30,72
ΔPs = ( )
5,22 x 10¹° x 2,56 ft x 2,58 x 0,83
= 0,001 Psi
ΔPs yang diperbolehkan 10 Psi
( T1-t2 ) -(T2-t1)
a. ΔT LMTD =
ln (T1-t2)/(T2-t1)
( 172-86 ) -(86-86)
=
ln ( 172-86 ) /(86-86)
41,06
=
3,71
= 11,05oF
T 1−T 2
b. R =
t2 ‒ t 1
140-86
=
131-86
= 1,91
t2 - t1
c. S =
T 1 - t1
LC-46
131-86
=
172-86
= 0,52
Dari Gambar 19 (Kern, 1965), diperoleh nilai FT = 0,85 maka,
d. Δt = FT× LMTD
Δt = 0,85× 11,05oF
= 9,61oF
c. Menghitung Temperature Kalorik Tc dan tc
T1+ T2
Tc =
2
172 + 86
=
2
= 129,03oF
t +t
tc = 1 2
2
86 + 131
=
2
= 151,50oC
Cek viskositas pada terminal dingin untuk tiap fluida
Tube :
Pada T = 129,03 oF
µ = 0,223 cP (Fig. 15, Kern, 1965)
= 0,54
Shell :
Pada t = 151,5oF
µ = 0,57 cP (Fig. 15, Kern, 1965)
= 1,38
Karena viskositas fluida ada terminal dingin <1 cP (kern, 1965 Hal. 111), maka :
Tc = Tavg
tc = tavg
d. Memilih Jenis Alat Perpindahan Panas
Hot fluida = shell
LC-47
=0,25 ft2
i. Menghitung Mass Velocity
Tube :
W
Gt = ( )
as
3.663,27 lb/jam
=
0,25 ft
= 14.482,91 lbm/jam ft2
Shell :
W 8.352,27 lbm/jam
Gs = ( )=( )
as 0, 25 ft²
= 14.482,91 lbm/jam Ft2
j. Menghitung Bilangan Reynold Number
Tube :
Viskositas pada tc = 155,5oF
µ = 0,22 cP (Fig. 14, Kern,1965)
= 0,54 lbm/ft.jam
De = 0,902 in (Tabel. 10, Kern, 1965)
Dc = 0,0752 ft
Dc x Gt
Ret =
µ
0,0752 ft x 14.482,91 lbm/jam ft²
=
0,54 lbm/ft.jam
= 4.881,76
16 ft
L/D =
0,0 752 ft
= 212,86 ft
jH = 28 (Fig. 24, Kern,1965)
Shell :
Viskositas pada Tc = 129,9 oF
µ = 0,57 cP (Fig. 14, Kern, 1965)
= 1,38 lbm/ft.jam
LC-50
= 2.096,21
jH = 35 (Fig. 28, Kern,1965)
k. Menentukan Thermal Function
Tube :
Viskositas pada tc =151,5oF
µ = 0,22 cP (Fig. 14, Kern,1965)
= 0,53 lbm/jam.ft
Kapasitas panas, Cp :
Cp = 0,43 Btu/lbm F (Fig.3, Kern,1965)
K = 0,09 Btu/hr (Ft2)(F/Ft)
c.μ 13
Pr = ( )
k
0,43 Btu/lb° F× 0,53 lb/ft.jam 1/3
=( )
0, 09 Btu/jam.lbm.ft. ° F
= 0,33 Btu/(hr)(ft2)(oF/ft)
Shell :
Viskositas pada Tc= 129,03 ºF
µ = 0,57 cP (Fig. 14, Kern,1965)
= 1,38 lbm/ft.jam
Kapasitas panas, Cp :
Cp = 1,02 Btu/lbm F (Fig.3, Kern,1965)
K = 0,38 Btu/hr (Ft2)(F/Ft)
c.μ 13
Pr = ( )
k
LC-51
198,89 Btu/hr.ft 2 . ºF
= 183ºF + x(129,03 ºF–
26,10 Btu/hr.ft 2 . ºF+ 198,80 Btu/hr.ft 2 . ºF
151,5ºF)
= 129,03ºF
Tube :
Pada tw = 129,03oF
µw = 0,34 cp (Fig. 14, Kern,1965)
= 0,82 lbm/ft.jam
0,54 l b/ft.jam
=(
0, 82 lb/ft.jam )
0,14
= 0,94
Shell;
Pada tw = 129,03ºF
µw = 0,57 cp (Fig. 14, Kern,1965)
= 2,47
= (1,38 l b/ft.jam
2,47 lb/ft.jam )
0,14
= 0,92
5. Menghitung Clean Overall Coeficient, Uc
h io x ho 183,33 x 273,80
Uc = =
hio + ho 183,33 + 273,80
=109,81 Btu/(hr)(ft2)(F)
6. Menghitung Dirt Factor, Rd
1 1
Ud
=
Uc
+ Rd
Uc - Ud
Rd =
Uc × Ud
LC-53
= 2,02 Psi
ΔPt + ΔPr = 0,00000003833+2,01 Psi
= 2,02 Psi
Shell:
1. Menentukan Faktor Friksi
Res = 2.096,21 (Fig. 26, Kern,1965)
LC-54
= 39,90 Ft
Ds = 39,90/12
= 3,71 ft
0,0026 x 14.482,91² lbm/jam.Ft ²x 39,90
ΔPs = ( )
5,22 x 10¹° x 2,56 ft x 1,01 x 0,92
= 0,001 Psi
ΔPs yang diperbolehkan 10 Psi
b. Menentukan ΔT LMTD
Fluida panas Fluida dingin ΔT (F)
246,5
T1 6 Temp Tinggi t2 122 124,56
T2 86 Temp Rendah t1 86 0
(T1-
T2) 60,56 (t2-t1) 46 124,56
( T1-t2 ) -(T2-t1)
a. ΔT LMTD =
ln (T1-t2)/(T2-t1)
( 246,56-122 ) -(86-86)
=
ln ( 246,56-122 ) -(86-86)
124,56
=
4,82
= 25,82oF
T 1−T 2
b. R =
t2 ‒ t 1
246,56-86
=
122-86
= 4,46
t2 - t1
c. S =
T 1 - t1
122-86
=
246,56-86
= 0,22
Dari Gambar 19 (Kern, 1965), diperoleh nilai FT = 0,98 maka,
d. Δt = FT× LMTD
Δt = 0,98× 25,82℉
LC-56
= 23,86oF
c. Menghitung Temperature Kalorik Tc dan tc
T1+ T2
Tc =
2
246,56+86
=
2
= 166,28oF
t +t
tc =1 2
2
122+86
=
2
= 147oC
Cek viskositas pada terminal dingin untuk tiap fluida
Tube :
Pada T = 166,28 oF
µ = 0,47 cP (Fig. 15, Kern, 1965)
= 1,13 lb/ft.jam
Shell :
Pada t = 147oF
µ = 1,01 cP (Fig. 15, Kern, 1965)
= 2,45
Karena viskositas fluida ada terminal dingin <1 cP (kern,. 1965 Hal. 111), maka :
Tc = Tavg
tc = tavg
= 1,25 -1 in
= 0,25 in
o. ATerkoreksi = Nt ×L × a”
= 348 ×16 ft ×0,2618 ft2/ft
= 2.185,44ft2
p. Ud Terkoreksi
Q
UDterkoreksi =
Aterkoreksi x ΔT LMTD
6.075.457,08 Btu/Jam
=
2.185,44 ft² x 25,30 °F
= 110 Btu/Jam Ft2oF
g. Analisa Kerja HE
Analisa kinerja HE meliputi :
1. MenghitungKoefisien Overall Perpindahan Panas (U)
2. Menghitung Rd
3. Menghitung ∆P
4). Menghitung Koefisien Overall Perpindahan Panas
h. Menghitung Flow Area
Tube:
Flow area tube, a’t = 0,639 in2
Nt x a't
at =
144 x n
348 x 0,639 in²
=
144 x 4
=0,93 ft2
Shell:
ID x C' x B
as= ( )
PT
31 x (1,25-1)' x (0,25x31
=( )
1,25
=0,33 ft2
LC-59
Dc = 0,99/12 = 0,0825 ft
Dc x Gs
Res = ( )
µ
0,0825 ft x 31.977,07
= 2,45
= 31.977,07
jH =100 (Fig. 28, Kern,1965)
k. Menentukan Thermal Function
Tube :
Viskositas pada Tc = 166,28oF
µ = 0,47 cP (Fig. 14, Kern,1965)
= 1,13 lbm/ft.jam
Kapasitas panas, Cp :
Cp = 0,99 Btu/lbm F (Fig.3, Kern,1965)
K = 0,39 Btu/hr (Ft2)(F/Ft)
c.μ 13
Pr = ( )
k
0,99 Btu/lb° F×1,13 lb/ft.jam 1/3
=(
0,39 Btu/jam.lbm.ft.° F
)
= 1,64 Btu/(hr)(ft2)(oF/ft)
Shell :
Viskositas pada tc= 147 ºF
µ = 1,01 cP (Fig. 14, Kern,1965)
= 2,45 lbm/ft.jam
Kapasitas panas, Cp :
Cp = 1,91 Btu/lbm F (Fig.3, Kern,1965)
K = 0,39 Btu/hr (Ft2)(F/Ft)
c.μ 13
Pr = ( )
k
1,91 Btu/lb ° F× 2,45 lb/ft.jam 1/3
=(
0,39 Btu/jam.lbm.ft.° F
)
= 1,64 Btu/(hr)(ft2)(oF/ft)
LC-61
1/3
0,38 Btu/hr (Ft ² )(F/Ft) 0,99 Btu/lbm x 1,13 cP
= 45(
0,0752 Ft (
)x
0,39 Btu/hr (Ft ² )(F/Ft) )
= 4,97 Btu/jam Ft oF
hio hi ID
= ( )x ( )
∅t ∅t OD
= 44,87Btu/hr.ft2.oF
hi o
hi =( ) x Øt
Øt
=44,87 x 0,87
= 389,02 Btu/hr.ft2.oF
LC-62
Shell:
1/3
ho k cxµ
∅s
= jh ( )x
De k ( )
1/3
0,39 Btu/hr (Ft²)(F/Ft) 1,9 Btu/lbm x 2,45 cP
= 100(
0,99
)x (
0,39 Btu/hr (Ft²)(F/Ft) )
= 174,56 Btu/jam Ft oF
hi
ho =( ) x Øs
Øs
= 174,56 x 0,99
= 174,68 Btu/hr.ft2.oF
Untuk nilai∅ t dan ∅ s diperoleh dari perhitungan tw (temperatur wall).
n. Menghitung Temperatur Wall, tw
ho
∅s
tw = tc + (Tc - tc)
hio ho
+
∅t ∅s
174,56 Btu/hr.ft 2. ºF
= 166,23ºF+ x(166 ºF–147ºF)
389,02 Btu/hr.ft 2. ºF + 174,56 Btu/hr.ft 2 . ºF
= 97ºF
Tube :
Pada tw = 97oF
µw = 1,3 cp (Fig. 14, Kern,1965)
= 3,14 lb/ft.jam
1,13 l b/ft.jam
=(
3,14 lb/ft.jam )
0,14
= 0,77
Shell;
Pada tw = 97ºF
µw= 1,02 cp (Fig. 14, Kern,1965)
= 2,47 lb/ft.jam
LC-63
= (2,45 l b/ft.jam
2,47 lb/ft.jam )
0,14
= 0,99
ft2 lb
0,00 024 2
× ( 141.092,60 ) 2 × 16 × 2
= in jam. ft2
5,22 x 10¹° x 0,0752 ft x 1 x 0, 74
= 0,0035 Psi
V²
= 0,003 (Fig. 27, Kern. 1965)
2g'
4n V²
b. ΔPr =( ) x ( )
S 2g'
4x4
=(
1
) x 0,003
= 0,0024 Psi
ΔPt + ΔPr = 0,0035 + 0,0024 Psi
= 0,027 Psi
Shell:
1. Menentukan Faktor Friksi
Res = 31.977,07 (Fig. 26, Kern,1965)
f = 0,00036 (Fig. 6, Kern,1965)
s = 1,79 (Fig. 2, Kern,1965)
2. Menentukan Pressure Drop Shel
f x Gs² x (N+1)
ΔPs =( )
5,22 x 10¹° x De x S x Øs
L
N + 1 = 12 x ( )
B
16
= 12 x (
0,25 x 31,25
)
= 24,77
Ds = 24,77/12
= 2,06 ft
0,00 0 36 x 393.414,90² lbm/jam.Ft ²x 24,77
ΔPs = ( )
5,22 x 10¹° x 2,56 ft x 1,79 x 0,87
= 0,0338 Psi
ΔPs yang diperbolehkan 10 Psi
LC-65
b. Menentukan ΔT LMTD
Fluida panas Fluida dingin ΔT (F)
T1 194 Temp Tinggi t2 230 -36
T2 86 Temp Rendah t1 122 -36
(T1-T2) 108 (t2-t1) 108 0
( T1-t2 ) -(T2-t1)
a. ΔT LMTD =
ln (T1-t2)/(T2-t1)
( 194-230 ) -(86-122)
=
ln ( 194-230 ) /(86-122)
LC-66
1,40
=
0,34
= 4,14oF
T 1−T 2
b. R =
t2 ‒ t 1
194-86
=
230-122
= 1,013
t2 - t1
c. S =
T 1 - t1
230-122
=
194-122
= 0,67
Dari Gambar 19 (Kern, 1965), diperoleh nilai FT = 0,79 maka,
d. Δt = FT× LMTD
Δt = 0,79× 4,14oF
= 3,27oF
c. Menghitung Temperature Kalorik Tc dan tc
T1+ T2
Tc =
2
194 + 86
=
2
= 141oF
t +t
tc =1 2
2
122 + 230
=
2
= 237oC
= 0,53 lb/ft.jam
Shell :
Pada T = 141oF
µ = 0,84 cP (Fig. 15, Kern, 1965)
= 2,03 lb/ft.jam
Karena viskositas fluida ada terminal dingin <1 cP (kern, 1965 Hal. 111), maka :
Tc = Tavg
tc = tavg
L = 16 ft
f. Menghitung Jumlah Tube
A 48,58 ft²
Nt = =
L.a ¿ 16 ft x 0,2618 ft²/ft
= 12 buah
Dc x Gt
Ret =
µ
0,0752 ft x 92,64 lbm/jam ft²
=
2,03 lbm/ft.jam
= 41,12
16 ft
L/D =
0,0 752 ft
= 212,86 ft
jH = 1 (Fig. 24, Kern,1965)
Shell :
Viskositas pada Tc = 141oF
µ = 0,22 cP (Fig. 14, Kern, 1965)
= 0,53 lbm/ft.jam
De = 0,99 in (Fig. 28, Kern, 1965)
Dc = 0,99/12 = 0,0825 ft
Dc x Gs
Res = ( )
µ
0,0825 ft x 755,38 lbm/jam.ft ²
= 0,53 lbm/ft.jam
= 155,62
jH = 14 (Fig. 28, Kern,1965)
k. Menentukan Thermal Function
Tube :
Viskositas pada tc =230oF
µ = 0,84 cP (Fig. 14, Kern,1965)
= 2,03 lbm/jam.ft
Kapasitas panas, Cp :
Cp = 0,46 Btu/lbm F (Fig.3, Kern,1965)
K = 0,22 Btu/hr (Ft2)(F/Ft)
c.μ 13
Pr = ( )
k
LC-71
hi o
hi =( ) x Øt
Øt
= 58,08 x 0,86
= 50,14 Btu/hr.ft2.oF
Shel l:
LC-72
1/3
ho k cxµ
∅s
= jh ( )x
De k ( )
1/3
0,09 Btu/hr (Ft²)(F/Ft) 0,76 Btu/lbm x 0,53 cP
= 14(
0,99
)x (
0,09 Btu/hr (Ft²)(F/Ft) )
= 73,04 Btu/jam Ft oF
hi
ho =( ) x Øs
Øs
= 73,04 x 0,79
= 57,60 Btu/hr.ft2.oF
Untuk nilai∅ t dan ∅ s diperoleh dari perhitungan tw (temperatur wall).
n. Menghitung Temperatur Wall, tw
ho
∅s
tw= tc + (Tc - tc)
hio ho
+
∅t ∅s
73,04 Btu/hr.ft 2. ºF
= 237ºF + x(141 ºF–237ºF)
58,08 Btu/hr.ft 2 . ºF+ 73,04 Btu/hr.ft 2. ºF
= 66,73ºF
Tube :
Pada tw = 66,73 oF
µw = 2,4 cp (Fig. 14, Kern,1965)
= 5,80 lbm/ft.jam
2,03 l b/ft.jam
=(
5,80 lb/ft.jam )
0,14
= 0,86
Shell;
Pada tw = 66,73ºF
µw = 1,2 cp (Fig. 14, Kern,1965)
= 2,90
= (0,53 l b/ft.jam
2,90 lb/ft.jam )
0,14
= 0,79
5. Menghitung Clean Overall Coeficient, Uc
h io x ho 57,60 x 55,58
Uc = =
hio + ho 57,60 + 55,58
=226,59 Btu/(hr)(ft2)(F)
ft2 lb
0,00 045 2
× (41,12 ) 2 × 16 × 4
= in jam. ft2
5,22 x 10¹° x 0,0752 ft x 0,79 x 0,86
= 0,0000000077Psi
V²
= 0,0001 (Fig. 27, Kern. 1965)
2g'
4n V²
b. ΔPr =( ) x ( )
S 2g'
4x4
=(
0,79
) x 0,0001
= 0,002 Psi
ΔPt + ΔPr = 0,0000000077+ 0,002 Psi
= 0,0020 Psi
Shell:
1. Menentukan Faktor Friksi
Res = 155,62 (Fig. 26, Kern,1965)
f = 0,001 (Fig. 6, Kern,1965)
s = 1,23 (Fig. 2, Kern,1965)
2. Menentukan Pressure Drop Shel
f x Gs² x (N+1)
ΔPs =( )
5,22 x 10¹° x De x S x Øs
L
N + 1 = 12 x ( )
B
16
= 12 x (
0,25 x 8
)
= 96 Ft
Ds = 96/12
= 8 ft
0,001 x 755,38² lbm/jam.Ft ²x 96
ΔPs = ( )
5,22 x 10¹° x 2,56 ft x 1,23 x 0,79
= 0,00000013 Psi
ΔPs yang diperbolehkan 10 Psi
LC-75
b. Menentukan ΔT LMTD
Fluida panas Fluida dingin ΔT (F)
T1 194 Temp Tinggi t2 230 -36
T2 86 Temp Rendah t1 122 -36
(T1-T2) 108 (t2-t1) 108 0
( T1-t2 ) -(T2-t1)
a. ΔT LMTD =
ln (T1-t2)/(T2-t1)
( 194-230 ) -(86-122)
=
ln ( 194-230 ) /(86-122)
LC-76
1,40
=
0,34
= 4,14oF
T 1−T 2
b. R =
t2 ‒ t 1
194-86
=
230-122
= 1,013
t2 - t1
c. S =
T 1 - t1
230-122
=
194-122
= 0,67
Dari Gambar 19 (Kern, 1965), diperoleh nilai FT = 0,79 maka,
d. Δt = FT× LMTD
Δt = 0,79× 4,14oF
= 3,27oF
c. Menghitung Temperature Kalorik Tc dan tc
T1+ T2
Tc =
2
194 + 86
=
2
= 141 oF
t +t
tc =1 2
2
122 + 230
=
2
= 237 oC
= 1,11 lb/ft.jam
Shell :
Pada T = 141 oF
µ = 0,49 cP (Fig. 15, Kern, 1965)
= 1,18 lb/ft.jam
Karena viskositas fluida ada terminal dingin <1 cP (kern, 1965 Hal. 111), maka :
Tc = Tavg
tc = tavg
L = 16 ft
f. Menghitung Jumlah Tube
A 818,67 ft²
Nt = = = 195 buah
L.a ¿ 16 ft x 0,2618 ft²/ft
Berdasarkan data jumlah tube yang tersedia secara komersial, dipilih
jumlah tube = 12 buah tube dengan OD tube 1 in, 11/4 in triangular pitch untuk
2passes (Kern, Tabel. 9).
Adapun data selengkapnya sebagai berikut :
m. Susunan tube = triangular pitch
n. Jumlah aliran, n = 4 aliran (passes)
o. Pitch, PT = 11/4 in
p. Diameter shell, ID = 19,25in = 1,60 ft
q. Baffle Space = 0,25× 19,25 in = 4,81ft
r. C = PT – OD tube
= 1,25 -1 in
= 0,25 in
g. ATerkoreksi = Nt ×L × a”
= 195 ×16 ft ×0,2618 ft2/ft
= 816,82ft2
h. Ud Terkoreksi
Q
UDterkoreksi =
Aterkoreksi x ΔT LMTD
2.143.768,10 Btu/Jam
=
816,82 ft ² x 4,13 F
=72 Btu/Jam Ft2oF
g. Analisa Kerja HE
Analisa kinerja HE meliputi :
1. Menghitung Koefisien Overall Perpindahan Panas (U)
2. Menghitung Rd
3. Menghitung ∆P
LC-79
= 18.489,30
jH = 80 (Fig. 28, Kern,1965)
k. Menentukan Thermal Function
Tube :
Viskositas pada tc=230 oF
µ = 0,46 cP (Fig. 14, Kern,1965)
= 1,11 lbm/jam.ft
Kapasitas panas, Cp :
LC-81
= 4,29 Btu/(hr)(ft2)(oF/ft)
Shell :
Viskositas pada Tc= 141 ºF
µ = 0,49 cP (Fig. 14, Kern,1965)
= 1,18 lbm/ft.jam
Kapasitas panas, Cp :
Cp = 1 Btu/lbm F (Fig.3, Kern,1965)
K = 0,38 Btu/hr (Ft2)(F/Ft)
c.μ 13
Pr = ( )
k
1 Btu/lb ° F× 1,18 lb/ft.jam 1/3
=( )
0, 38 Btu/jam.lbm.ft. ° F
= 7,04 Btu/(hr)(ft2)(oF/ft)
l. Menghitung Nilai Inside Film Coefficient (hi) dan Outside Film
Coefficient (ho)
Tube :
hi k c . μ 13
∅t
= jH ( )(
Dc k )
1/3
0,22 Btu/hr (Ft²)(F/Ft) 1,01 Btu/lbm x 1,11 lbm/ft.jam
= 100
0,0752 Ft
)x (
0,22 Btu/hr (Ft²)(F/Ft) )
= 104,56 Btu/jam Ft oF
hio hi ID
= ( )x ( )
∅t ∅t OD
= 94,31Btu/hr.ft2.oF
hi o
hi =( ) x Øt
Øt
= 94,31 x 0,88
LC-82
= 92,55 Btu/hr.ft2.oF
Shel l:
1/3
ho k cxµ
∅s
= jh ( )x
De k ( )
1/3
0,38 Btu/hr (Ft²)(F/Ft) 1 Btu/lbm x 1,18 cP
= 80(
0,99
)x (
0,38 Btu/hr (Ft²)(F/Ft) )
= 120,85 Btu/jam Ft oF
ho
ho =( ) x Øs
Øs
= 120,84 x 0,88
= 106,60 Btu/hr.ft2.oF
Untuk nilai∅ t dan ∅ s diperoleh dari perhitungan tw (temperatur wall).
n. Menghitung Temperatur Wall, tw
ho
∅s
tw = tc + (Tc - tc)
hio ho
+
∅t ∅s
106,60 Btu/hr.ft 2 . ºF
= 237ºF + x(141 ºF–237ºF)
120,84 Btu/hr.ft 2 . ºF +160,60 Btu/hr.ft 2. ºF
= 66,73ºF
Tube :
Pada tw = 66,73 oF
µw = 1,1 cp (Fig. 14, Kern,1965)
= 2,66 lbm/ft.jam
1,11 l b/ft.jam
=(
2,66 lb/ft.jam )
0,14
= 0,88
Shell;
Pada tw= 66,73 ºF
µw= 1,2 cp (Fig. 14, Kern,1965)
= 2,90 lb/ft.jam
LC-83
= (1,18 l b/ft.jam
2,90 lb/ft.jam )
0,14
= 0,88
5. Menghitung Clean Overall Coeficient, Uc
h io x ho 106,60 x 92,54
Uc = =
hio + ho 106,60 - 92,54
=226,59 Btu/(hr)(ft2)(F)
6. Menghitung Dirt Factor, Rd
1 1
= + Rd
Ud Uc
Uc - Ud
Rd =
Uc × Ud
226,59 Btu/hr.ft ² .° F- 75 Btu/hr.Ft ² .° F
=
226,59 Btu/hr.ft ² .° F x 75 Btu/hr.Ft ² . ° F
= 0,009 Btu/hr.ft2.oF
Rd yang diperlukan = 0,001 Btu/hr.ft2.ºF (Table. 12, Kern,1965)
ft2 lb
0,00 01 2
× (187,30 ) 2 × 16 × 4
= in jam. ft 2
5,22 x 10¹° x 0,0752 ft x 1 x 0, 86
= 0,0047Psi
V²
= 0,01 (Fig. 27, Kern. 1965)
2g'
4n V²
b. ΔPr =( ) x ( )
S 2g'
4x4
=(
1
) x 0,01
= 0,16
ΔPt + ΔPr = 0,0047+ 0,61 Psi
= 0,16 Psi
Shell:
1. Menentukan Faktor Friksi
Res = 18.489,30 (Fig. 26, Kern,1965)
f = 0,001 (Fig. 6, Kern,1965)
s = 1,2351 (Fig. 2, Kern,1965)
2. Menentukan Pressure Drop Shel
f x Gs² x (N+1)
ΔPs = ( )
5,22 x 10¹° x De x S x Øs
L
N + 1 = 12 x ( )
B
16
= 12 x (
0,25 x 19,25
)
= 39,38 Ft
Ds = 39,38/12
= 3,28 ft
0,001 x 38.021,86² lbm/jam.Ft ²x 39,38
ΔPs = ( )
5,22 x 10¹° x 2,56 ft x 1,2351 x 0,79
= 0,0005 Psi
ΔPs yang diperbolehkan 10 Psi
LC-85
Dasar Perencanaan:
Temperatur = 30℃ = 86℉
Laju alir massa (F) = 4162,831kg/jam = 152,7759kg/menit = 2,5513lbm/s
Densitas (ρ) = 811,32 kg/m3 = 50,6263 lbm/ft3
Viskositas (μ ¿ = 0,3251 Cp = 0,0002185lbm/ft.s
F
Q =
ρ
9179,0423 lbm/ jam
=
50,6263 lbm /ft 3
= 181,3095 ft3/jam = 0,0503 ft3/s
Desain pompa:
Diopt = 3,9 (Q)0,45 (ρ)0,13
= 3,9 (0,0503 ft3/s)0,45 (50,6263lbm/ft3) 0,13= 1,692726 in
Dari Appendiks A.5 Geankoplis, 1983, dipilih pipa commercial steel:
NPS = 2 in = 0,0508 m
Schedule number = 40 = 1,016 m
Diameter dalam (ID) = 2,38 in = 0,060452m
Diameter luar (OD) =2,067in = 0,0525018m = 0,1722 ft
Inside schedule area (A) = 0,02329ft2
Kecepatan linear, V = Q/A
0,05036 ft 3 /s
=
0,0 2329 ft 2
= 2,1623ft/s = 0,6487 m/s
Bilangan Reynold:
LC-86
ρ ×V ×ID
NRe =
μ
( 50,6263 ) × ( 0,6487 ) ×( 0, 0508 )
=
0,0003252
= 5130,4437> 2100 (aliran turbulen) α = 1
Direncanakan bahan pipa commercial steel
ε = 4,6 x 10-5
= 0,000046m (Geankoplis fig. 2.10-3, hal 88)
ε 0,000046 ft
=
ID 0,0508 ft
= 0,0009055
Frictional losses:
2
ft
Ff
=4 x f x
∆L
ID ( )
x ( ( 3,167946
detik
2 x 1 x 32,174
)
)
2
ft
=4 x 0,0055 x (7,8206696
0,1722 ft
ft
) x (
( 2,1623
detik
2 x 1 x 32,174
)
)
= 0,07260243ft.lbf/lbm
Sehingga total friction loss yang terjadi pada sistem perpipaan:
∑F =Hc+Hex+ Ff
= (0,0396+ 0,07266373+ 0,07260243) ft.lbf/lbm
= 0,1849ft.lbf/lbm
Menentukan Daya Pompa
Diketahui :
Z1 = 0 m
Z2 = 2 m
Dari persamaan Bernouli:
1 ∆ V2 ∆P
+ g ( Z2- Z1) + + ∑ F+ W s
2α gc ρ
( 273578 – 101325 ) pa
0 + 9,8 m/s2 (2 m - 0 m) + + 0,1849+ Ws = 0
811 kg/ m 3
Ws= -232,0969 J/Kg
Efesiensi pompa = 75 %
232,0969 J/kg
Daya actual motor, Wp = =309,4626 J/Kg
0,75
=103,5316 f lbf/lbm
Daya pompa, P = m x Wp
= (2,5513x 103,7598)
= 264,1262f lbf/lbm = 0,4802 hp
LC-89
Dasar Perencanaan:
Temperatur = 50℃ = 122℉
Laju alir massa (F) = 21.008,22 kg/jam= 771,00kg/menit = 12,86lbm/s
Densitas (ρ) = 946,9 kg/m3 = 59,0865 lbm/ft3
Viskositas (μ ¿ = 0,5208 Cp = 0,0003499 lbm/ft.s
F
Q =
ρ
46315,1792 lbm/ jam
=
59,0865 lbm /ft 3
= 783,853032 ft3/jam = 0,217736ft3/sDesain pompa:
Bilangan Reynold:
ρ ×V ×ID
NRe =
μ
( 59,0865 ) × ( 1,273010 ) ×( 0, 07792)
=
0,0003499
= 11005,369> 2100 (aliran turbulen) α = 1
Direncanakan bahan pipa commercial steel
ε = 4,6 x 10-5
= 0,000046m (Geankoplis fig. 2.10-3, hal 88)
ε 0,000046m
=
ID 0,0762 m
= 0,00060367
2
ft
= 0,75 ( ( 4,2433
detik
2 x 1 x 32,174
)
)
= 0,2098ft.lbf/lbm
( )
F f =4 x f x
∆L
ID
x ( ( 4,2433
detik
2 x 1 x 32,174
)
)
LC-92
2
ft
=4 x 0,0055 x (9,2628 ft
0,2526 ft )
x ( ( 4,2433
detik
2 x 1 x 32,174
)
)
= 0,2052ft.lbf/lbm
Sehingga total friction loss yang terjadi pada sistem perpipaan:
∑ F=Hc+ Hex + F f
= (0,151496 + 0,2798+ 0,2052) ft.lbf/lbm
= 0,636524ft.lbf/lbm
Menentukan Daya Pompa
Diketahui :
Z1 = 0 m
Z2 = 2 m
Dari persamaan Bernouli:
1 ∆ V2 ∆P
+ g ( Z2- Z1) + + ∑ F+ W s
2α gc ρ
( 202650 – 101325 ) pa
0 + 9,8 m/s2 (2 m - 0 m) + + 0,63652484+ Ws = 0
946 kg/ m 3
Ws= -127,243601 J/Kg
Efesiensi pompa = 75 %
127,243601 J/kg
Daya actual motor, Wp = =169,6581 J/Kg
0,75
=56,75963 f lbf/lbm
Daya pompa, P = m x Wp
= (12,8757 lb/sx 56,75963 f lbf/lbm)
= 730,8213f lbf/lbm = 1,3 hp
LC-93
Dasar Perencanaan:
Temperatur = 30℃ = 86℉
Laju alir massa (F) = 3787,879kg/jam = 139,015lb/menit = 2,32155lb/s
Densitas (ρ) = 911,2kg/m3 = 56,8589 lbm/ft3
Viskositas (μ ¿ = 0,299 Cp = 0,0002lbm/ft.s
F
Q =
ρ
8350,8433 lbm/ jam
=
56,8589 lbm /ft 3
= 146,8696 ft3/jam = 0,040797ft3/s
Desain pompa:
Diopt = 3,9 (Q)0,45 (ρ)0,13
= 3,9 (0,040797 ft3/s)0,45 (56,8589 lbm/ft3) 0,13
= 1,563046 in
Dari Appendiks A.5 Geankoplis, 1983, dipilih pipa commercial steel:
NPS =2 in = 0,0508 m
Schedule number = 40 = 1,016 m
Diameter dalam (ID) = 2,067 in = 0,0525m
Diameter luar (OD) = 2,38 in = 0,06045 m =0,1983 ft
Inside schedule area (A) = 0,03088ft2
Kecepatan linear, V = Q/A
0,040797 ft 3 /s
=
0,03088 ft 2
= 1,3211ft/s = 0,3963 m/s
Bilangan Reynold:
LC-94
ρ ×V ×ID
NRe =
μ
( 56,8589 ) × ( 1,3211 ) ×( 0, 0508 )
=
0,0002
= 3828,926> 2100 (aliran turbulen) α = 1
Direncanakan bahan pipa commercial steel
ε = 4,6 x 10-5
= 0,000046m (Geankoplis fig. 2.10-3, hal 88)
ε 0,000046m
=
ID 0,062 m
= 0,000742
2
ft
= 0,75 ( ( 1,3212
detik
2 x 1 x 32,174
)
)
= 0,02345ft.lbf/lbm
Frictional losses:
2
ft
( )
F f =4 x f x
∆L
ID
x ( ( 4,2433
detik
2 x 1 x 32,174
)
)
2
ft
=4 x 0,0049 x (7,2720 ft
0,198331 ft )
x (
( 1,3211
detik
2 x 1 x 32,174
)
)
= 0,1949ft.lbf/lbm
Sehingga total friction loss yang terjadi pada sistem perpipaan:
∑ F=Hc+ Hex + F f
= (0,014784+ 0,02712+ 0,1949) ft.lbf/lbm
= 0,236858ft.lbf/lbm
Menentukan Daya Pompa
Diketahui :
Z1 = 0 m
Z2 = 2 m
Dari persamaan Bernouli:
1 ∆ V2 ∆P
+ g ( Z2- Z1) + + ∑ F+ W s
2α gc ρ
( 184411 – 182385 ) pa
0 + 9,8 m/s2 (2 m - 0 m) + + 0,236858+ Ws = 0
911 kg/ m 3
Ws= -22,06085 J/Kg
Efesiensi pompa = 75 %
22,06085 J/kg
Daya actual motor, Wp = =29,41446 J/Kg
0,75
=9,8406 f lbf/lbm
Daya pompa, P = m x Wp
= (2,32155 lb/sx 9,8406 f lbf/lbm)
= 22,8457f lbf/lbm = 0,0415 hp
Dasar Perencanaan:
Temperatur = 30℃ = 86℉
Laju alir massa (F) = 91,3542kg/jam = 3,3527lb/menit = 0,05599lb/s
Densitas (ρ) = 721,1kg/m3 = 44,9966 lbm/ft3
Viskositas (μ ¿ = 0,1908 Cp 0,00013lbm/ft.s
F
Q =
ρ
201,40154 lbm/ jam
=
44,9966 lbm /ft 3
= 4,4759 ft3/jam = 0,001243ft3/s
Desain pompa:
Diopt = 3,9 (Q)0,45 (ρ)0,13
= 3,9 (0,001243 ft3/s)0,45 (44,9966 lbm/ft3) 0,13
= 0,315166in
Dari Appendiks A.5 Geankoplis, 1983, dipilih pipa commercial steel:
NPS =0,5 in = 0,0127 m
Schedule number = 40 = 1,016 m
Diameter dalam (ID) = 0,84 in = 0,0213m
Diameter luar (OD) = 0,622 in = 0,0158 m =0,0518ft
Inside schedule area (A) = 0,00211ft2
Kecepatan linear, V = Q/A
0,001243 ft 3 /s
=
0,0518 ft 2
= 0,5895ft/s = 0,1768 m/s
Bilangan Reynold:
LC-98
ρ ×V ×ID
NRe =
μ
( 44,9966 ) × ( 0,1768 ) ×( 0,0127 )
=
0,000191
= 529,682< 2100 (aliran laminar)
Direncanakan bahan pipa commercial steel
ε = 4,6 x 10-5
= 0,000046m (Geankoplis fig. 2.10-3, hal 88)
ε 0,000046m
=
ID 0,0127 m
= 0,003622
= 0,00405ft.lbf/lbm
Frictional losses:
2
ft
Ff = 4 x f x
∆L
( )
ID
x ( ( 0,5895
detik
2 x 1 x 32,174
)
)
2
ft
¿ 4 x 0,03 x
1,9005 ft
(
0,051833 ft
x ) (
( 0,5895
detik
2 x 1 x 32,174
)
)
= 0,0237625ft.lbf/lbm
Sehingga total friction loss yang terjadi pada sistem perpipaan:
∑ F=Hc+ Hex + F f
= (0,002968+ 0,0054006 + 0,0,0237625) ft.lbf/lbm
= 0,032131ft.lbf/lbm
Menentukan Daya Pompa
Diketahui :
Z1 = 0 m
Z2 = 2 m
Dari persamaan Bernouli:
1 ∆ V2 ∆P
+ g ( Z2- Z1) + + ∑ F+ W s
2α gc ρ
( 212782 – 202650 ) pa
0 + 9,8 m/s2 (2 m - 0 m) + + 0,032131+ Ws = 0
721,1 kg/ m 3
Ws= -33.68358 J/Kg
Efesiensi pompa = 75 %
33,68358 J/kg
Daya actual motor, Wp = =44,91144 J/Kg
0,75
=15,0252 f lbf/lbm
Daya pompa, P = m x Wp
= (0,05599 lb/sx 15,0252 f lbf/lbm)
= 0,84126f lbf/lbm = 0,0015 hp
LC-101
Dasar Perencanaan:
Temperatur = 30℃ = 86℉
Laju alir massa (F) = 17152,12kg/jam = 629,483lb/menit = 10,5124/s
Densitas (ρ) = 998,8kg/m3 = 62,3251/ft3
Viskositas (μ ¿ = 0,2286 Cp = 0,00015 lbm/ft.s
F
Q =
ρ
37813,947 lbm/ jam
=
62,3251 lbm /ft 3
= 606,7208 ft3/jam = 0,168534ft3/s
Desain pompa:
Diopt = 3,9 (Q)0,45 (ρ)0,13
= 3,9 (0,168534 ft3/s)0,45 (62,3251 lbm/ft3) 0,13
= 2,994882 in
Dari Appendiks A.5 Geankoplis, 1983, dipilih pipa commercial steel:
NPS =3 in = 0,0762 m
Schedule number = 40 in = 1,016 m
Diameter dalam (ID) = 3,5 in = 0,0889m
Diameter luar (OD) = 3,068 in = 0,07793 m =0,2556ft
Inside schedule area (A) = 0,05131ft2
Kecepatan linear, V = Q/A
0,168534 ft3 /s
=
0,05131 ft2
= 3,284467 ft/s = 0,98534 m/s
LC-102
Bilangan Reynold:
ρ ×V ×ID
NRe =
μ
( 62,3251 ) × ( 0,98534 ) ×( 0, 0762 )
=
0,00015
= 20470,48> 2100 (aliran turbulen)
Direncanakan bahan pipa commercial steel
ε = 4,6 x 10-5
= 0,000046m (Geankoplis fig. 2.10-3, hal 88)
ε 0,000046m
=
ID 0,00762 m
= 0,000604
2
ft
= 0,75 ( ( 3,284467
detik
2 x 1 x 32,174
)
)
= 0,125735ft.lbf/lbm
2
ft
=4 x 0,03 x (9,374262 ft
0,2556 ft )
x ( ( 3,284467
detik
2 x 1 x 32,174
)
)
= 0,1426103 ft.lbf/lbm
Sehingga total friction loss yang terjadi pada sistem perpipaan:
∑ F=Hc+ Hex + F f
= (0,090763 + 0,1676466+ 0,1426103) ft.lbf/lbm
= 0,40102ft.lbf/lbm
Menentukan Daya Pompa
Diketahui :
Z1 = 0 m
Z2 = 2 m
Dari persamaan Bernouli:
1 ∆ V2 ∆P
+ g ( Z2- Z1) + + ∑ F+ W s
2α gc ρ
( 212782 – 202650 ) pa
0 + 9,8 m/s2 (2 m - 0 m) + + 0,40102+ Ws = 0
998,8 kg/ m 3
Ws= -30,14569 J/Kg
Efesiensi pompa = 75 %
30,14569 J/kg
Daya actual motor, Wp = =40,19426 J/Kg
0,75
=13,44711 f lbf/lbm
Daya pompa, P = m x Wp
= (10,5124lb/sx 13,4471 f lbf/lbm)
= 141,3609 f lbf/lbm = 0,2570 hp
k−1
( )[( ) ]
−4 k P2 k. N at
2,78×10 N st mvl P 2 −1
k−1 P1
Pad =
(Peters,dkk.,2004)
Dimana :
m
mvl =
ρ
= 4.162,83 kg/jam
1.808,32 kg/m3
= 2,30 m3/jam x
1 jam
3600 menit
= 0,0006 m3/s
= 13,60 hp
Pad
P= 1 3,60
η = 80% = 17,00 hp
Keterangan :
F = Umpan Masuk
B = Hasil Bawah
D = Distilasi
C.17.1Penentuan Tipe Kolom Distilasi
Dalam perancangan menara distilasi ini dipilih jenis tray yaitu sieve tray
dengan pertimbangan :
1. Cairan yang ingin dipisahkan memiliki viskositas rendah
2. Pressure drop rendah dan efisiensi tinggi
3. Lebih ringan, dan murah kaena pembuatannya mudah
4. Biaya perawatan murah kaena mudah dibersihkan.
C.17.3Tahap Perancangan
Perhitungan dilakukan untuk mnegetahui spesifikasi menara distilasi (D-
001) meliputi :
1. Kondisi operasi
2. Spesifikasi shell (diameter tinggi, tinggi dan tebal) dan head menara
3. Spesifikasi plate
4. Cek kondisi aliran
5. Isolasi (ketebalan)
6. Spesikasi alat penunjang menara distilasi (nozzle, manhole, bolt, flange,
penyangga).
LC-109
=
Log (1,8568
0,0051 ) x(
0,01
0,00 )
Log 1,4520
= 11,43
5. Menentukan Refluks Ratio Minimum
Untuk menghitung refluks rayio minimum digunakan persamaan
Underwood :
αi x Xi.F
∑ αi- θ =0
LC-111
Keterangan :
αi = Relatif volatilitas rata-rata komponen i
Xi.F = Fraksi mol komponen i dalam feed
Xi.D = Fraksi mol komponen i dalam distilat
Rm = Reluks minimum
R = Refluks
Tabel C.9 Hasil Perhitungan θ untuk Umpan Masuk
αi x Xi.F
Komponen αavg Xi,F αavg*Xi.F ∑ αi- θ
C3H8O 1,4520 0,0084 0,0121 0,0088
C3H6O 1,0724 0,2926 0,3137 0,3130
H2 0,4441 0 0 0
H2O 0,7813 0,9721 0,7596 1,0678
1,9962 = Rm + 1
Rm = 1,9962 – 1
Rm = 0,9962
Roperasi berkisar antara 1,2-1,5 Rm
Roperasi = 1,2 x 0,9962
= 1,1955
6. Penentuan Jumlah Stage Ideal
R Op 1,1955
=
R OP + 1 1,1955 + 1
= 0,54
Rm 0,9962
=
Rm + 1 0,9962 + 1
LC-112
= 0,49
ΣYD
1
µtop avg = YD =
Σ 4,3032
µ
= 0,2324
LC-113
ΣYB
1
µbot avg = YB =
Σ 0,00 50
µ
= 201,1959
µavg = √ µ top X μ bot
= √ 0,2324 x 201,1959
= 6,8378
αLK avg x µavg = 1,0724 x 6,8378
= 7,3327
Eo = 57%
Naktual = 35,1761 plate
Nr
= 0,5575
Ns
Nr = 0,5575 Ns
Jumlah plate termasuk reboiler = 36, sedangkan jumlah plate tanpa reboiler
adalah 35 plate.
Nr + Ns =N
Nr + Ns = 35,1761
(0,5575 Ns) + Ns =35,1761
35,1761
Ns = = 22,5843
1+0,5575
= 23
LC-115
Nr = 0,5575 Ns
= 0,5575 x 22,5843
= 12,5907
= 13
Jadi, umpan masuk pada tray ke 13 dari atas dan tray ke 23 dari bawah.
Keterangan :
FLV = Liquid-vapor flow factor
Lw = Laju alir massa cairan (kg/jam)
Vw = Laju alir massa uap (kg/jam)
ρL = Densitas cairan (kg/m3)
ρv = Densitas uap (kg/m3)
1). Liqud vapour flow reactor on top
Diketahui:
Lw = 4.528,43 kg/jam
Vw = 8.316,31kg/jam
ρv = 2,00 kg/m3
ρL = 184,96 kg/m3
4.528,43 184,96
F LV, top =
√
8.316,31 2,00
FLV, top = 0,06
Plate spacing 0,45 dan FLv = 0,06 maka Ki = 0,08
kg
uf, bot = 0,079
√
= 1,94 m/s
239,41
m3
0,63 kg/ m 3
– 0,63 kg/ m 3
= 4,92 ft/s
Kecepatan uap pada umumnya 70-90% dari kecepatan flooding
(Coulson,1983), untuk perancangan diambil uv = 80% uf
Kecepatan uap pada bagian atas (top):
uv,top = 80% x uf top (C.2)
= 80% x 0,54 m/s
= 0,43 m/s
= 1,42 ft/s
Kecepatan uap pada bagian bawah (bottom):
uv,bot = 80% x uf bottom (C.3)
= 80% x 1,94 m/s
= 1,55 m/s
= 5,10 ft/s
c. Menentukan Laju Alir Volumetrik Maksimum (Uv maks)
LC-118
v
Uvmaks =
ρv x 3600
(C.4)
Keterangan:
Uvmaks = laju alir volumetrik maksimum (m3/s)
V = laju alir massa uap (kg/jam)
Laju alir volumetrik maksimum bagian atas:
8.316,31 kg/jam
UVmaks top = kg
2,00 x 3600
m3
= 1,15 m3/s
Laju alir volumetrik maksimum bagian bawah:
8.316,31 kg/jam
UVmaks botom = kg
0,63 x 3600
m3
= 3,68 m3/s
d. Menentukan Luas Area Netto untuk Kontak Uap-Cair
Qv
An = (C.5)
Uv
Keterangan:
An = Luas area Netto (m2)
Qv = Laju alir volumetrik (m3/s)
Uv = Kecepatan uap (m/s)
Luas area netto bagian atas (top):
1,15
An,top =
0,43
= 2,67 m2
Luas area netto bagian bawah (bottom):
3,68
An,bot =
1,55
= 2,36 m2
LC-119
= 3,33 m2
Luas downcomer (Ad) = 0,12 Ac (C.10)
= 0,40 m2
Luas netto (An) = Ac – Ad (C.11)
= 2,93 m2
Luas aktif (Aa) = Ac – 2 Ad (C.12)
= 2,53 m2
Luas hole (Ah) = 0,03 Aa (C.13)
= 0,08 m2
Dari Gambar D.3 untuk Ad/Ac = 0,16 maka:
lw/Dc = 0,82
Panjang weir (lw) = 0,82 x Dc (C.14)
= 1,69 m
2/3
Lw,min
how, min = 750
[ ρL . I w ]
2/3
1,01 kg/ s
= 750
[ 184,96 kg/ m3 x 1,69 m ]
=0,003 m/sliquid
1,15
=
0,08
= 15,16 m/s
Uam<^u h sehingga tidak terjadi weeping.
2). Menara bagian bawah
2/3
Lw,maks
how,max =750 x
[
ρL . I w ]
2
1,26 kg/s
= 750 x
[ 239,41 kg/ m3 x 1,69 m ]
3
2/3
1,01 kg/ s
= 750
[ 239,41 kg/ m 3 x 1,69 m ]
=0,001 m/sliquid
Pada rate minimum hw + how = 50 mm + 0,002
= 50,002 m/s
Dari fig. 11.30 (coulson,1983), maka di peroleh :
K2= 30
Minimum design vapour velocity (^u h)
[ K2 -0,90 (25,4-dh ]
^u h = 1/2
(ρv )
(C.18)
[ K2 -0,90 (25,4-dh ]
^u h = 1/2
(ρv)
[ 30-0,90 (25,4-5 m ]
= 1/2
( 0,68 kg/ m 3 )
= 1.890,15 m/s
Actual minimum vapour velocity (Uv, min actual)
Qvbot
Uam = (C.19)
Ah
3,68
=
0,08
= 48,36 m/s
Uam<^u h sehingga tidak terjadi weeping.
11. Plate Pressure Drop
a. Menara Bagian Atas
^ h)
Jumlah maksimum vapour yang melewati hole (U
^ h= Qv,maks
U (C.20)
Ah
1,15 m 3 /s
=
0,08 m 2
= 15,16 m/s
LC-126
Keterangan :
uh = Kecepatan uap maksimum melewati hole (m/s)
Ah = Luas hole (m2)
Uv.bottom = Laju alir volumetrik uap maksimum bagian bottom (m3/s)
ρv = densitas uap bagian Top (kg/m3)
ρL = densitas liquid bagian Top (kg/m3)
Co = orifice coefficient hd = Dry plate drop (mm)
hd = Dry plate drop (mm)
2
u^ h ρ v
hd = 51 x [ ]
Co ρ L
LC-127
2
15,16 0,63
hd = 51 x [ ]
0,76 239,41
= 53,65 mm liquid
Residual head (hr)
12,5 x 10 3
hr =
ρL
(C.22)
Keterangan :
hr = residual head (mm)
ρL = densitas liquid bagian bottom (kg/m3)
12,5 x 10 3
hr =
239,41
= 52,21 mm liquid
Total pressure drop (ht)
ht = hd + (hw + how ) + hr (C.23)
= 53,65+ (50+ 0,004 ) + 52,21
= 155,87 mm
ΔPt = 9,81 x 10-3 x ht x ρL (C.24)
= 9,81 x 0,001 x 155,87 x 239,41
= 366,07 Pa
= 0,004 atm
2). Menara Bagian Bawah
^ h)
Jumlah maksimum vapour yang melewati hole (U
^ h = Uv,maks
U
Ah
(C.25)
^ h = 3,68
U
0,08
= 48,36
Dari figure 11.34 JM. Couildson ed 6, untuk:
Platethickness
=1
holediameter
LC-128
Ah Ah
= =0,03
Ap Aa
Ah
x 100 =3
Ap
Sehingga didapat nilai Orifice coefficient (Co) = 0,76
2
48,36 0,6281
= 51 x [ ]
0,76 239,4076
= 546,01 mm liquid
Keterangan :
^h
U = Kecepatan uap maksimum melewati hole (m/s)
Ah = Luas hole (m2)
Uv.bottom= Laju alir volumetrik uap maksimum bagian bottom (m3/s)
ρv = densitas uap bagian Bottom (kg/m3)
ρL = densitas liquid bagian Bottom (kg/m3)
Co = orifice coefficient hd
hd = Dry plate drop (mm)
ht = hd + (hw + how ) + hr
= 546,01+ (50+ 0,002 ) +52,21
= 648,22 mm liquid
ΔPt= 9,81 x 10-3 x ht x ρL
= 9,81 x 0,001 x 648,22 x 239,41
= 1.522,40 Pa
= 0,015 atm
2
1,26
hdc = 166 x [ 184,96 x 0,07 ]
= 1,33 mm
Back up di downcomer (hb)
LC-130
2
1,26
hdc = 166 x [239,41 x 0,07 ]
= 0,80 mm
LC-131
= 88
Iw/Dc = 0,82
Iw/Dh = 0,18
b. Panjang rata-rata unperforated edge strips
α
Lav = × π × (Dc – 0,05) (C.42)
180
88
Lav = ×π×(2,06 – 0,05)
180
= 3,09 m
c. Luas unperforated edge strips
(Aup) = 0,05 × Lav (C.43)
= 0,05 x 3,09 m
= 0,15 m2
d. Luas calming zone
(Acz) = 2 x hw x (lw – (2 x hw)) (C.44)
= 2 x 0,05 x (1,69 – (2 x 0,05)
= 0,16 m2
e. Luas total tersedia untuk perforasi
Ap = Aa – (Aup + Acz) (C.45)
= 2,53 – (0,15 + 0,16)
= 2,22 m2
Ah 0,08
=
Ap 2,22
= 0,03
LC-135
r
w =1 3+ c ( √ ) (C.52)
4 icr
1 84
=
4 ( √ )
3+
5,5
= 1,73 in = 0,04 m
P. r c .w
th = + 0,0127 (C.53)
2 fε-0,2 P
= 0,0005 in = 0,02 m
t head standar = 5/8 in = 0,625 in = 0,015875 m maka tebal yang digunakan:
t head = 0,87 in (0,0221 m)
Untuk tebal head 5/8 in, berdasarkan Tabel 5.8 (Brownell dan Young,
1959) maka sf = 1,5 – 3,5 in. Diambil sf = 2 in (0,0508 m)
2
= rc – ( r c -icr) 2 - ( ID - icr)
b
√ 2
(C.54)
2
= 84 – (84-5,5)2 - ( 81,10 - 1,875)
√ 2
= 14,27 in
= 0,36 m
c. Tinggi Head (OA)
OA = th + b + sf (C.55)
= (0,0005 + 14,27 + 2) in
= 16,27 in
= 0,41 m
AB = rc – icr (C.56)
= 40,59 – 5,5 in
= 35,09 in
= 0,89 m
LC-139
BC = rc – icr (C.57)
= 84 – 5,5 in
= 78,5 in
= 1,9939 m
AC = √ BC2 - AB2 (C.58)
= √ 78,52 – 35,092 in
= 70,23 in
= 1,78 m
d. Tinggi Menara
Data perhitungan:
Diameter kolom (Dc) = 2,06 m = 81,16 in
Luas kolom (Ac) = 3,33 m2
Volume head = 0,000049 Dc3 (C.59)
= 0,000049 (2,06)3
= 0,0001 m3
Volume head pada sf = π/4 x ID2 x sf (C.60)
= 3,14/4 x (2,06)2 x (0,05)
= 0,17 m3
Volume total head = Vhead tanpa sf+ Vhead pada sf (C.61)
= 0,0001 m3 + 0,17 m3
= 0,17 m3
Blank diameter = OD +OD/24 +2sf +2/3.icr (C.62)
= 2,10 + 2,10/2 + 2 x 0,0508 + 2/3 (0,14)
= 0,08 in = 3,34 m
Untuk bagian bottom kolom:
L
Q= (C.63)
ρL
8.316,31
Q=
239,41
Q = 34,74 m3/jam = 0,58 m3/menit
Waktu tinggal cairan di bawah plate terakhir : 5 - 10 menit (Ulrich, 1984).
LC-140
a. Pipa feed
Diketahui:
G = 21.031,35 kg/jam = 5,84 kg/s
μ = 0,000008844 Pa.s
ρ = 227,35 kg/ m3
A’ = 0,864 in2
ID = 3,068 in
OD = 3,5 in
A’ = 7,38 in2
= 838,81 kg
c. Berat Jacket (Isolator)
Data perhitungan :
pIsolator = 489 lb/ft3 (Foust, App. D.10)
Volume Isolator = ρ (Dc) (Tdish) (Sf)
= 3,14 (2,06) (18) (0,0508)
= 6,07 m3
= 214,56 ft3
Berat Isolator = 214,56 ft3 x 489 lb/ft3
= 104.992,56 lb
= 47.583,38 kg
d. Berat Opening
Berat manhole
Manhole 20 in = 428 lb = 194,1375 kg
Berat tutup = 690,22 kg
Total berat Manhole = 194,1375 kg + 690,22 kg
= 884,35 kg
= 1.950,06 lb
Manhole (2) = 2 x 884,35 kg
= 1.768,71 kg
Berat Nozzle
Ukuran nozzle = nozzle feed + nozzle produk
= 10 lb + (2+2+10+10) lb
= 34 lb
= 15,42 kg
Berat nozzle = 3 in + (1+1+3+3) in
= 11 in
Berat Opening total = 1.768,71kg + 15,42 kg
= 1.784,13 kg
e. Berat fluida dalam kolom
Berat bahan baku :
LC-147
Volume feed = 93 m3
Densitas feed dalam kolom = 227,35 kg/m3
Berat fluida dalam kolom = 93 m3 x 227,35 kg/m3
= 21.031,35 kg/m3
Maka berat total kolom adalah :
Berat total = berat shell + berat dish head and bottom + berat isolator + berat
opening +berat fluida dalam kolom
= (1.921,86 + 690,22 + 47.582,38 + 1.768,71 + 1.784,13) kg
Wtot = 53.747,30 kg
23. Penyangga Distilasi Peralatan dan Penunjang Kolom Distilasi
A. Desainskirt support
Skirtadalah penyanggayang digunakandan paling aman untuk menjaga
vertikalvessel. Skirtdisatukan denganvesselmenggunakan pengelasan kontinyu,
ukuran pengelasanditentukan berdasarkan ketebalanskirt.Ketebalan dariskirt
harus mampu untuk menahandead weightdanbending momentdarivessel.
Ketebalan skirtharus lebih dari 6 mm.
a. Momen pada base
M = Pw Dis H. hl (C.74)
(Megesy, 1983) (6.45)
Keterangan:
Pw = wind presure 25 lb/ft2
(Tabel 9.1, Brownel, 1959)
Dis = diameter menara dengan isolator = 2,06 m
H =tinggi total menara = 18,45 m
hl = level arm=H/2 = 9,24 m
M = 122,06 x 2,06 x 18,45 x 9,24
= 42.954,70 m/Kg
b. Momen pada ketinggiantertentu(batas antarapenyambungskirt)
MT = M-hT(V-0,5Pw DishT) (C.75)
(Megesy, 1983)
V = total shear
LC-148
= Pw x Di x Hl
= 4.649,30 Kg
hT = ketinggian skirt
=hl/2 = 4,62 m
Momen pada batas penyambung:
MT = 25.269,37 – 3,30 (3.832,90 – (0,5 x 122,06 x 2,38 x 3,30) )
= 14.214,02 m/Kg
c. Menentukan tebal skirt
12 x M T W
t = 2 x
( R x π x S x E) D x π x S x E
t = 0,0105 m
= 10,5 mm
= 0,4147 in
d. Berat Downcomer
Diketahui:
Ad = 0,40 m2
Tebal = 0,01 m
Jumlah plate = 35 buah
Densitas shell = 7840 kg/m3
Volume = Ad × tebal
= 0,40 m2 × 0,01 m
= 0,005 m3
Berat 1 plate = volume × densitas
LC-149
e. Berat Cairan
Diketahui :
V cairan = 2,89 m3
ρ campuran = 184,96 kg/m3
M = 2,89 m3 × 184,96 kg/m3
M = 535,41 kg
Maka berat menara total = 53.747,30 kg + 1.401,96 kg + 4.599,59 kg + 535,41 kg
= 60.284,25kg
B. Desain Anchor Bolt
LC-150
Vertikal vessel harus merekat erat pada concrete fondation, skirt atau yang
lain dengan anchor bolt dan base (bearing) ring. Jumlahanchor bolt harus 4 atau
kelipatannya untuk setiap vertikal vessel, pada vessel yang tinggi sebaiknya
menggunakan 8 buah anchor bolt.Agar merekat kuat pada concrete fondation,
anchor bolt sebaiknya tidak dipasang terlampau dekat, yakni tidak kurang dari 18
in. Pada vessel diameter kecil agar jarak minimal dari anchor bolt terpenuhi,
sebaiknya menggunakan conical skirt atau wider base ring with gussets, atau
anchor bolt chair.
Penentuan maximum tension dapat menggunakan persamaan sebagai
berikut:
12 M W
T = − (C.76)
AB CB
Keterangan :
M = momen pada base ring berdasarkan tekanan angin
= 42.954,70 kg.m
W = Berat vessel (pada ereksi)
= 453.747,29 kg
Diameter tempat bolt-bolt dipasang diasumsikan sebesar 30 in (Megyesy, 2001).
AB = Area di dalam lingkaran bolt
= 707 in2 = 0,456 m2
CB = Circumference pada lingkaran bolt
= 94 in = 2,387 m
Sehingga tension maksimum pada bolt:
12M W
T = - (C.77)
AB CB
12 ×42.954,70 53.747,29
= -
0,456 2,387
= 1.107.558,29 kg/m
a. Menentukan area bolt
Penentuan besarnya area bolt dapat menggunakan persamaan sebagai
berikut:
LC-151
T CB
BA¿ (C.78)
SB N
Keterangan :
T = maximum tension dari bolt
= 1.107.558,29 kg/m
S B = maximum allowable stress value dari material bolt bahan (SA 307)
= 15.000 psi = 10.546.050 kg/m2 (Megyesy, 2001)
C B = circumference pada lingkaran bolt = 94 in
N = jumlah anchor bolts
= 8 buah
A = 1,75 in E = 0,75 in
B =3 in F = 1,25 in
C = 2,5 in G = 1,5 in
D = 0,5 in
LC-153
Diketahui:
W = momen pada base ring = 42.954,70 kg
M = berat vessel = 53.747,29 kg
CB = circumference pada OD skirt = 94 in = 2,3876 m
AB = area di dalam skirt = 0,4561 m2
FB = safe bearing load on concrete = 500 psi = 351.535 kg/m2
1. Menentukan Maximum Kompresi pada Base Ring
12 M W
Pc = +
AB CB
Pc = 1.152.580,32 kg/m
2. Lebar Base Ring
Pc
I =
Fb
1.152.580,32
I = = 3,28 m = 129,08 in
351.535
Berdasarkan tabel A Megyesy,1985 digunakan bot dengan ukuran 1 in, sehingga
diperoleh:
I2 = 1,375 in
I3 = 1,0625 in
Itot = 1,375 in + 1,0625 in
Itot = 2,4375 in
3. Menentukan Ketebalan Base Ring
Tb = 0,32 × Itot
= 0,32 × 2,4375 in
= 0,78 in
= 0,02 m
D. Perhitungan Flange
a. Sambungan head dengan shell
Sambungan antara tutup bejana dengan bagian shell menggunakan sistem
flange dan baut. Bahan konstruksi yang dipilih berdasarkan pada kondisi operasi.
Data perancangan :
Tekanan desain = 40,56 psi
LC-155
sehingga
y-P.m
do/di =
√ y-[P ( m+1 ) ]
(C.81)
= 1,0057 m
Asumsi bahwa diameter dalam gasket di sama dengan diameter luar shell,
sehingga :
Do = 1,0057 x 2,4171 m = 2,4308 m
lebar gasket minimum ( N) :
do-di
N = (C.82)
2
= 0,006 m = 0,235 in
Digunakan gasket dengan lebar 0,235 in
Diameter gasket rata-rata, G = do + lebar gasket (C.83)
= 2,11 m+ 0,006 m
= 2,116 m
= 83,25 in
Menentukan Berat Gasket
Dari figure 12.12 (brownell and Young), kolom I tipe A diperoleh:
N 0,235
Bo = = = 0,12 in
2 2
= 0,003 m
B = bo ketika bo< b
Berat untuk menjaga joint tight saat operasi digunakan persamaan 12.90 Brownell
Hp =2bπGmp (C.85)
= 2 x 0,003 m x 3,14 x 2,11 m x 2,75 x 28.516,87 psi
= 3.111,37 kg
= 6.859,44 lb
Keterangan :
Hp = beban join tight (lb)
m = faktor gasket (fig 12.11)
b = Effective gasket (in)
G = Diameter gasket rata-rata (in)
P = Tekanan operasi (psi)
Beban dari tekanan internal dihitung dengan persamaan 12.89 Brownell & young
(1959).
π G2
H = P (C.86)
4
3,14 (2,11)2
H = x 28.516,87
4
= 100.095,88 kg
= 220.674,79 lb
Beban operasi total dihitung dengan persamaan 12.91 Brownell & young (1959).
, Wm2 = H + Hp (C.87)
= 100.095,88 kg + 3.111,37 kg
= 103.207,25 kg
= 227.534,22 lb
Wm2lebih besardari Wm1 sehingga beban pengontrol berada pada Wm2 = 227.534,22
lb
Wm1 = beban berat bolt pada kondisi operasi (lb)
Wm2 = beban berat bolt pada kondisi tanpa tekanan dalam (lb)
H = total joint contact surface (lb)
Wm1
Aml =
fb
Keterangan :
LC-158
= 2.628,25 kg x 0,67 m
= 795,55 m.kg
HG dicari menggunakan persamaan 12.98 Brownell & Young.
HG = W – H = Wm1 – H (C.96)
= 64.446,09 kg
hG = ½ (C- G)
= 0,68 m
Momen dicari dengan persamaan 12.98 Brownell & Young
MG = HG x hG (C.97)
= 48.491,85 kg x 0,68 m
= 32.794,31 m.kg
HT dihitung dengan menggunakan persamaan 12.97 Brownell & Young
HT = H - HD (C.98)
= 98.903,73 kg
Hubungan lever arm adalah dengan persamaan 12.102 Brownell & Young.
hT = ½ (hD + hG) (C.99)
= 0,67 m
The moment dicari dengan persamaan 12.97 Brownell & Young
MT = HT x hT (C.100)
= 66.443,86 kg m
Jumlah momen pada kondisi operasi, MO
MO = MD + MG + MT (C.101)
= 795,55 kg m + 32.794,31 kg m + 66.443,86 kg m
= 100.033,72 kg m
(Pers. 12.99, Brownell, 1959)
Momen operasi adalah momen pengontrol, sehingga Mmax = 100.033,72 kg m
t =
√ YMmax (C.102)
fB
Diketahui:
LC-161
K = A/B = 0,34
dari fig. 12.22 Brownell didapat nilai Y = 10
sehingga di dapat ketebalan flange adalah, t = 9,40 in
Gambar C.23 Detail Untuk Flange dan Bolt pada Head Menara
Data perhitungan:
r1 = 1,1901 m
r2 = 1,2085 m
T1 = 393,31 K = 248,29 oF
TU = 308,15 K = 95 oF
kp = 25,7305 Btu/hr.Ft2.oF
kis = 0,053 Btu/hr.Ft2.oF
L = 13,19 m
a. Temperatur Isolasi Permukaan Luar
Isolasi yang digunakan akan dilapisi dengan cat (pigmen) berwarna putih.
Berdasarkan tabel 8.3 (Holman, 1979) diperoleh data:
q
( )sun = 500
A
W/m2
σ surya = 0,18
σ suhu rendah = 0,8
W
σ = 5,669 ×10-8
m2 K 4
q
( )sun× σ surya = σ suhu rendah × σ(T4- T4sur) (C.104)
A
W
500 W/m2×0,18 = 0,8 ×5,669 ×10-8 ×(T4- 303,154K4)
m2 K 4
W
90 W/m2 = 0,000000045352 × (T4- 8445595756 K4)
m2 K 4
T4 = 1430072736
T = 319,5742911 K
T = 46,4242911 ℃
b. Panas yang Hilang dari Dinding Isolasi ke Udara
1. Koefisien perpindahan panas radiasi
εσ( T 4i - T 4u )
hr = (C.105)
T 1 - T2
LC-163
kg 2 m 1
(13,19 m)3 (1,1373109 ) ×9,8 2 ×0,00322 ×(313,384-303,15)
m3 s k
2
m2
( 0,000019 kg.
s )
= 14,68× 1011
c p .μ
Npr = (Geankoplis, pers. 4.7-4, 1993) (C.108)
k
kj m
1,0048 .K ×0,000019 kg.
kg s
=
watt
0,02698`40441 .K
m
= 0,707591336
LC-164
Dengan substitusi persamaan (1) ke (2) maka diperoleh nilai jari-jari isolator (r3)
adalah 2,9479
Tebal isolasi (xis)
xis = r 3 – r2 (C.114)
= 2,9479 – 1,1116
= 1,7394 m
Qlosss = qr × r (C.115)
= 18.405,61r3 x 2,9479
= 54.257,89 Watt/jam
c. Panas Hilang Dari Head Dan Bottom
Asumsi:
1. Tebal isolasi head sama dengan tebal isolasi dinding
2. (hr + hc) head sama dengan (hr + hc) dinding silinder
3. Luas head sama dengan luas bagian silinder
Persamaan panas hilang dari head menara:
Q = (hr + hc). A. (Ti – Tu) (C.116)
A = surface of head
= 0,109 D2 (Tabel 10.6 Wallas, 2005)
= 0,109 ×(2,38)2
= 0,6176 m2
Jadi panas yang hilang dari head menara distilasi adalah:
Q = 7.053,52W/m2.jam. K x 0,6176 x (393,31-308,15)
= 711,56 W/jam
Panas total yang hilang ke lingkungan:
Q = panas hilang dari dinding menara + (2 × panas hilang dari head
menara)
= 54.257,89 Watt/jam + (2 × 711,56 W/jam)
= 55.681,01 Watt/jam
Perhitunganawaltebalshelldanheadmenaratelahdilakukan.Menaracukup
tinggi sehinggaperlu dicek pengaruhangin dangempa.
Spesifikasi menara:
OD shell = 2,42 m
Tinggi menara = 13,19 m
Tekanan operasi = 2,3 atm
Bahan konstruksi = Carbon steel
Tinggi skirt = 3,3 m
Tebal isolasi =0,0937 ft
Diameter = 2,71 m = 106,79 in
Beban Head = 634,65 lb
π
Wshell = x (Do – Di) x ρ x X (Pers. 9.1, Brownell,1959)
4
Wshell = 730,76 X
fdead wt shell = 3,4 X (Pers. 9.3a, Brownell,1959)
X = Jarak dari puncak ke bawah
Isolator
Diketahui:
Dins = 2,38 m
ρ s in = 18 lb/ft3
tins = 1,73 m
π
Wins = x (Dins2) x X x tins x ρins
4
Wins = 1.639,16 X (lb)
ρins x ( X) x t
fdead, ins = ins
(Pers. 9.4a, Brownell,1959)
144 x (ts-c)
fdead, ins = 2,6907 X
Attachment
Wt isolasi = 64,53 lb/ft
LC-168
Untuk ketinggian total menara (vessel + skirt) 54,10 ft, berat menara plus
attachment, liquids, dan lainnya dapat di hitung dengan mengalikan compressive
stress total terhadap berat dengan luas permukaan penampang menara.
fdw shell = 11.505,60 psi
fdw ins = 634,65 psi
fdw attach = 10.151,9276 psi
fdw tray+liquid = 69,43 psi
fdw total = 22.361,61 psi
Berat Menara Pada Kondisi Operasi
ΣW = fdw(total) π d ts
= 22.361,61 psi x 3,14 x 7,81 ft x 0,06 ft
= 33.054 lb
W avg = 2.754 lb/ft
Momen Karena Gempa
4 CW X 2 (3H-X)
Msx =
H
Keterangan:
Msx = Momen bending, lb
C = Koefisien seismic = 0,05
H = Tinggi menara total = 43,27 ft
W = Berat menara = 120.674,90 lb
X = Tinggi total menara – tinggi skirt= 54,10 ft
4 (0,05 x 120.674,90 x ( 54,102 (3(43,27)-(54,10))
Msx=
43,27
= 196.506,52 lb
Stress Karena Gempa, fsx
M sx
fsx =
π r 2 (ts-c)
= 444,54 psi
Stress karena angina:
fwx = 8,11 X2
= 0,5595 x 43,272
LC-170
= 1.047,55 Psi
LC-171
2. Struktur kuat
3. Tahan terhadap korosifitas tinggi.
C.18.3Tahap Perancangan
Perhitungan dilakukan untuk mnegetahui spesifikasi menara distilasi (D-
101) meliputi :
1. Kondisi operasi
2. Spesifikasi shell (diameter tinggi, tinggi dan tebal) dan head menara
3. Spesifikasi plate
4. Cek kondisi aliran
5. Isolasi (ketebalan)
6. Spesikasi alat penunjang menara distilasi (nozzle, manhole, bolt, flange,
penyangga).
1. Menentukan Kondisi Operasi Menara Distilasi
Berikut adalah neraca massa pada menara distilasi 001.
Tabel C.14 Neraca Massa Distilasi (D-101)
Masuk (Kg/jam) Keluar (Kg/jam)
Komponen
Feed Top Bottom
C3H8O 72,4111 72,4111 0
C3H6O 18,9393 18,9393 0
H2 0 0 0
H2O 17152,12159 0,0036 17152,1179
91,3541 17152,1179
Total 17243,47214
17243,47214
=
Log (0,8921
0,0070 )
x ( 1,3438 )
Log 1,2247
= 22,4307
5. Menentukan Refluks Ratio Minimum
Untuk menghitung refluks rayio minimum digunakan persamaan
Underwood :
αi x Xi.F
∑ αi- θ =0
Keterangan :
αi = Relatif volatilitas rata-rata komponen i
Xi.F = Fraksi mol komponen i dalam feed
Xi.D = Fraksi mol komponen i dalam distilat
Rm = Reluks minimum
R = Refluks
Tabel C.19 Hasil Perhitungan θ untuk Umpan Masuk
Kompone αi x Xi.F
n
αavg Xi,F αavg*Xi.F ∑ αi- θ
C3H8O 1,2247 0,0070 0,0086 0,0074
C3H6O 0,5238 0,0013 0,0007 0,0015
H2O 0,6431 0,8921 0,5738 1,0010
Maka :
αi x Xi.D
∑ αi- θ = Rm +1
2,260 = Rm + 1
LC-176
Rm = 2,2609 – 1
Rm = 1,2609
Roperasi berkisar antara 1,2-1,5 Rm
Roperasi = 1,2 x 1,2609
= 1,8914
6. Penentuan Jumlah Stage Ideal
R Op 1,8914
=
R OP + 1 1,8914 + 1
= 0,6542
Rm 1,2609
= =0,5577
Rm + 1 1,2609 + 1
ΣYD
1
µtop avg = YD = = 0,8305
Σ 1,2040
µ
Tabel C.22 Hasil Perhitungan µavg Produk Bawah
Kompone BM Bottom
Yj, B µ,B Y,B/µ
n (Kg/Kmol) (Kmol/jam)
C3H8O 60,0960 0 0 1,91E+01 0
C3H6O 58,0800 0 0 2,31E-01 0
H2O 18,0151 952,0969 1 7,61E-140 1,77E+167
ΣYB
1
µbot avg = YB =
Σ 1,77E-167
µ
= 5,65E-168
µavg = √ µ top X μ bot
= √ 0,8305 x 1,77E-167
=2,16E-84
αLK avg x µavg = 2,16E-84 x 1,2247
= 2,65E-84
Eo = 64%
Naktual = 47,12 plate
LC-178
Nr B X HK,F X LK,B 2
Log = 0,206 x Log [ ( )( )]
Ns D X LK,F X HK,D
953,6279 0,9947 0
= 0,206 x Log [ ( )( )2]
1,2049 0,0041 0,000039
Nr
= 0,2155
Ns
Nr = 0,2155 Ns
Jumlah plate termasuk reboiler = 48, sedangkan jumlah plate tanpa reboiler
adalah 47plate.
Nr + Ns =N
Nr + Ns = 47,1233
(0,2155 Ns) + Ns =47,1233
47,1233
Ns = = 38,7667
1+0,2155
= 39
Nr = 0,2155 Ns
= 0,2155 x 38,7667
= 8,3566
=8
Jadi, umpan masuk pada tray ke 8 dari atas dan tray ke 39 dari bawah.
Keterangan :
FLV = Liquid-vapor flow factor
Lw = Laju alir massa cairan (kg/jam)
Vw = Laju alir massa uap (kg/jam)
ρL = Densitas cairan (kg/m3)
ρv = Densitas uap (kg/m3)
1). Liqud vapour flow reactor on top
Diketahui:
LC-181
Lw = 172,7954 kg/jam
Vw = 264,1496 kg/jam
ρv = 4,0043 kg/m3
ρL = 239,4076 kg/m3
172,7954 239,4076
F LV, top =
√
264,1496 4,0043
FLV, top = 0,0211
Plate spacing 0,45 dan FLv =0,021 maka Ki = 0,08
kg
uf,bot = 0,062
√
= 0,6926 m/s
239,7808
m3
1,8042 kg/m 3
– 1,8042 kg/m 3
= 2,2722 ft/s
Kecepatan uap pada umumnya 70-90% dari kecepatan flooding
(Coulson,1983), untuk perancangan diambil uv = 80% uf
Kecepatan uap pada bagian atas (top):
uv,top = 80% x uf top (C.118)
= 80% x 0,3065 m/s
= 0,2452 m/s
= 0,8045 ft/s
Kecepatan uap pada bagian bawah (bottom):
uv,bot = 80% x uf bottom (C.119)
= 80% x 0,6926 m/s
= 0,5540 m/s
= 1,8177 ft/s
264,1496 kg/jam
UVmaks botom = kg
0,5543 x 3600
m3
= 0,1323 m3/s
d. Menentukan Luas Area Netto untuk Kontak Uap-Cair
Qv
An = (C.121)
Uv
Keterangan:
An = Luas area Netto (m2)
Qv = Laju alir volumetrik (m3/s)
Uv = Kecepatan uap (m/s)
Luas area netto bagian atas (top):
m3
0,2938
s
An,top =
m
0,2452
s
= 1,1981m2
Luas area netto bagian bawah (bottom):
m3
0,1323
s
An,bot =
m
0,5540
s
= 0,2389 m2
e. Menentukan Luas Penampang Lintang Menara
Menghitung luas penampang lintang menara:
An
Ac = (C.122)
1-Ad
Luas penampang downcomer (Ad)= 20% dari luas keseluruhan, sehingga:
An
Ac,top =
1-Ad
1,1981 m 2
=
1- 0,2
= 1,4977 m2
LC-184
An
Ac,bot =
1- Ad
0,2389 m 2
=
1 - 0,2
= 0,2986 m2
LC-185
Dari figure11.28 (Coulson, 1983) untuk QLB = 0,00021 m3/s, maka jenis alirannya
adalah reverse flow
10. Perancangan Tray
Tray spacing = 0,45 m
Diameter menara, Dc = 1,38 (Coulson, 1983)
Luas tray (Ac) = (π/4 x Dc2) (C.125)
= 1,4977 m2
Luas downcomer (Ad) = 0,12 Ac (C.126)
= 0,1797 m2
Luas netto (An) = Ac – Ad (C.127)
= 1,3179 m2
Luas aktif (Aa) = Ac – 2 Ad (C.128)
= 1,1382 m2
Luas hole (Ah) = 0,03 Aa (C.129)
= 0,0341 m2
Dari Gambar D.3 untuk Ad/Ac = 0,12 maka:
lw/Dc = 0,74
Panjang weir (lw) = 0,74 x Dc (C.129)
= 1.0221 m
LC-187
= 0,0977 mm liquid
2/3
Lw,min
how, min = 750
[ ρL . I w ]
2/3
3,8702 kg/ s
= 750
[
239,4076 kg/ m3 x 1,02 m ]
=0,0825 m/sliquid
Pada rate minimum hw + how = 50 mm + 0,0977 m/s
= 50,0977 m/s
LC-189
= 1,971 in
Dari fig. 11.30 Coulson 1983, nilai K2 diperoleh ebagai berikut:
0,1323
=
0,0341
= 3,8768 m/s
Uam<^u h sehingga tidak terjadi weeping.
2). Menara bagian bawah
2/3
Lw,maks
how,max =750 x
[ ρL .I w ]
2
4,8378 kg/s
= 750 x
[ 239,4076 kg/ m3 x 1,02 m ]
3
0,1323
=
0,0341
= 3,8768 m/s
Uam<^u h sehingga tidak terjadi weeping.
11. Plate Pressure Drop
a. Menara Bagian Atas
^ h)
Jumlah maksimum vapour yang melewati hole (U
^ h= Qv,maks
U (C.135)
Ah
0,2938 m 3 /s
=
0,0341 m 2
= 8,6042 m/s
Dari figure 11.34 JM. Couildson ed 6, untuk:
= 103,5685 mm
ΔPt = 9,81 x 10-3 x ht x ρL (C.138)
= 9,81 x 0,001 x 103,5685 x 239,7808
= 243,6191 Pa
= 0,0024 atm
2). Menara Bagian Bawah
^ h)
Jumlah maksimum vapour yang melewati hole (U
^ h = Uv,maks
U
Ah
(C.139)
^ h = 0,1323
U
0,0341
= 3,87 m/s
Dari figure 11.34 JM. Couildson ed 6, untuk:
Plate thickness
=1
hole diameter
Ah Ah
= =0,03
Ap Aa
Ah
x 100=3
Ap
Sehingga didapat nilai Orifice coefficient (Co) = 0,757
2
3,87 0,5543
= 51 x [ ]
0,757 239,7808
=3,091 mm liquid
Keterangan :
^h
U = Kecepatan uap maksimum melewati hole (m/s)
Ah = Luas hole (m2)
Uv.bottom= Laju alir volumetrik uap maksimum bagian bottom (m3/s)
LC-194
= 50 – 10
= 40 mm
= 0,001574 in
Area under apron (Aap)
Aap = hap . IW (C.143)
= 40 (1,02)
= 40,8856 m
= 0,0408 m2
Head loss in the downcomer (hdc)
2
Lm,max
hdc = 166 x
[ ρL Aap ] (C.144)
2
4,8378
hdc = 166 x [239,4076 x 0,0408 ]
= 0,000008381 mm
Back up di downcomer (hb)
hb = (hw + how) + ht + hdc (C.145)
= ( 50+ 0,0977 )+103,5685 + 0,0000083
= 153,6663 mm
= 0,153 m
1
hb < (lt + hw) = 0,25 m
2
Ketentuan bahwa nilai hb harus lebih kecil dari (plate spacing + weir
height)/2, telah terpenuhi. (J.M. Couldson.p.474)
b. Menara Bagian Bawah
Downcomer pressure loss (hap)
Pada saat menara distilasi dioperasikan, diharapkan tidak terjadi
downcomer liquid back-up. Besaran-besaran yang perlu dihitung untuk
menentukan apakah terjadi downcomer liquid back-up atau tidak adalah :
hap = hw - (5 to 10 mm) (C.146)
hap = hw – (10 mm)
= 50 – 10
LC-196
= 40 mm = 0,001574 in
Area under apron (Aap)
Aap = hap . IW (C.147)
= 40 (1,02)
= 40,8856 m
= 0,0408 m2
Head loss in the downcomer (hdc)
2
Lm,max
hdc = 166 x
[ ρL Aap ] (C.148)
2
4,8378
hdc = 166 x [
239,4076 x 0,0408 ]
= 0,0000184 mm
Back up di downcomer (hb)
hb = (hw + how) + ht + hdc (C.149)
= ( 50+ 0,0977 )+103,5685+ 0,0000184
= 153,6663 mm
= 0,153 m
1
hb < (lt + hw) = 0,25 m
2
Ketentuan bahwa nilai hb harus lebih kecil dari (plate spacing + weir
height)/2, telah terpenuhi. (J.M. Couldson.p.474)
uv
%flooding= x 100
uf
0,2229 m/s
%flooding= x 100
0,3065 m/s
%flooding=72,72 %
Untuk nilai FLv = 0,03 dari fig.29 didapat nilai ψ = 0,034. ketentuan
bahwa nilai ψ harus lebih kecil dari 0,1 telah terpenuhi.
b. Menara bagian Atas
Entrainment dihitung dari % flooding, dengan persamaan :
uv
% flooding = x100% (C.162)
u
(Coulson, 1986)
Keterangan :
uv = kecepatan uap aktual, m/s
uf = kecepatan uap perancangan, m/s
Persen flooding actual
Uv,maks
uv= (C.162)
An
0,1323
uv =
1,3179
= 0,1004
uv
%flooding= x 100
uf
0,1004 m/s
%flooding= x 100
0,6926 m/s
%flooding=14,50 %
Untuk nilai FLv = 0,04 dari fig.29 didapat nilai ψ = 0,0029. ketentuan
bahwa nilai ψ harus lebih kecil dari 0,1 telah terpenuhi.
= 88
Iw/Dc = 0,74
Iw/Dh = 0,18
b. Panjang rata-rata unperforated edge strips
α
Lav = × π × (Dc – 0,05) (C.165)
180
88
Lav = ×π×(1,32 – 0,05)
180
= 2,0436 m
c. Luas unperforated edge strips
(Aup) = 0,05 × Lav (C.166)
= 0,05 x 2,0436 m
= 0,1021 m2
d. Luas calming zone
(Acz) = 2 x hw x (lw – (2 x hw)) (C.167)
= 2 x 0,05 x (1,02– (2 x 0,05)
= 0,0,922 m2
e. Luas total tersedia untuk perforasi
Ap = Aa – (Aup + Acz) (C.168)
= 1,1382– (0,1021+ 0,0,922)
LC-201
= 0,9438 m2
Ah 0,0341
=
Ap 0,9438
= 0,0361
= 364,77 kpa
= 52,9055 psi
Keterangan:
ts = Tebal shell (m)
P = Tekanan operasi (psi)
f = Allowable stress (psi)
r = Jari-jari shell (m)
E = Efisiensi pengelasan
C = Faktor korosi (in)
P ×r
ts = +c
F × E−0,6 × P
52,90 × 0,6906
= + 0,0127
10000 × 0,85-0,6 × 52,90
LC-204
= 0,0170 m
Digunakan tebal standar untuk shell : 5/8 in = 0,625 in = 0,015875 m
d. Menentukan Tebal Head
OD = ID + (2 x ts) (C.174)
= (1,38) + (2 x 0,0170)
= 1,4153 m
= 55,72 in
Berdasarkan tabel 5.7 (Brownel, 1959), maka diperoleh:
icr = 3,625 in ( 0,0920m)
rc = 54 in (1,3716 m)
r
w =1 3+ c ( √ ) (C.175)
4 icr
1 84
=
4 ( √ )
3+
5,5
= 1,7149 in= 0,0439 m
P . rc . w
th = + 0,0127 (C.176)
2 f ε−0,2 P
= 0,0189m= 0,0004in
t head standar = 5/8 in = 0,625 in = 0,015875 m maka tebal yang digunakan:
t head = 0,87 in (0,0221 m)
Untuk tebal head 5/8 in, berdasarkan Tabel 5.8 (Brownell dan Young,
1959) maka sf = 1,5 – 3,5 in. Diambil sf = 2 in (0,0508 m)
2
= rc – ( r c -icr) 2−( ID - icr)
b
√ 2
2
(C.177)
= 11,9772 in
= 0,3042 m
AB = rc – icr (C.179)
= 27,1903 – 3,625 in
= 23,5653 in
= 1,0504 m
BC = rc – icr (C.180)
= 54 – 3,625 in
= 50,375 in
= 1,9939 m
AC = √ BC2 −AB2 (C.181)
= √ 50,3752−23,56532 in
=44,5231 in
= 1,6947 m
d. Tinggi Menara
Data perhitungan:
Diameter kolom (Dc) = 1,38 m = 93,7115 in
Luas kolom (Ac) = 1,4977 m2
Volume head = 0,000049 Dc3 (C.182)
= 0,000049 (1,38)3
= 0,000129132 m3
Volume head pada sf = π/4 x ID2 x sf (C.183)
= 3,14/4 x (1,38)2 x (0,0508)
= 0,0760 m3
Volume total head = Vhead tanpa sf+ Vhead pada sf (C.184)
= 0,000129132 + 0,0760m3
= 0,0762 m3
Blank diameter = OD +OD/24 +2sf +2/3.icr (C.185)
= 1,4153 + 1,4153/24 + 2 x 0,0508 + 2/3 (0,0920)
= 0,0580 in = 2,28 m m
LC-206
Berikut ini adalah neraca massa dan neraca energi reaktor (R-101).
Perhitungan nya dapat dilihat pada lampiran A dan lampiran B.
Tabel C.23 Neraca Massa Reaktor (R-101).
F1 F2
Komponen
Kg/Jam Kmol/Jam Kg/Jam Kmol/Jam
C3H8O 3999,3457 66,5493 79,9869 1,3310
C3H6O - - 3.787,8788 65,2183
H2 - - 131,4801 65,2183
H2O 163,4853 9,0749 163,4853 9,0749
Total 4162,8310 75,6242 4.162,8310 140,8425
B. Laju Reaksi
LC-210
dimana:
A = konstanta Arhenius, 315.000 m3/kg cat s
Ea = Energi aktivasi 72,38 kJ/mol
(Halim dkk, 2010)
R = Konstanta gas ideal, 8,314 J/mol K = 8,314 x 10-3 kJ/mol K
T = Suhu, 350℃ = 623,15 K
-72,38
(k) = 315.000exp 8,314 x 10 -3
× 623,15
Dimana :
Dp/Dt = rasio diameter katalis per diameter pipa
Hw/h = rasio koefisien transfer panas pipa berisi katalis terhadap koefisien
transfer panas pada pipa kosong
Dari data diatas hw/h terbesar pada 7,8 pada (Dp/Dt) = 0,15
Dp 0,3 7 cm
Dt = = = 2,4667 cm = 0,9712 in
0,15 0,15
Untuk pipa komersial : (kern,1983)
NPS = 1 in
ID = 1,049 in = 0,026645m = 2,66446 cm
OD = 1,32 in = 0,03353 m = 3,3528 cm
a’ = 0,864 in2
Dt = 2,4 cm
G (umpan total) = 4162,8310Kg/jam
= 1156,341962gr/s
OD ×V0 × ρ
Jumlah tube=
μ
0,0335∈× 0,049 ×5606
¿
0,216 Pas
= 42 buah
Z panjang tube standar 24 ft = 7,3152 m
Susunan pipa yang digunakan adalah triangular pitch (segitiga sama sisi)
dengan tujuan agar memberikan turrbulensi yang lebih baik, sehingga akan
memperbesar koefisien transfer panas konveksi (ho). Sehingga transfer panasnya
lebih baik dari square pitch (Kern,1983).
0,14
μ
hi =
0,021 x kf x Re0,8 x Pr 0,33 x ( )
μw
IDt
Volume Tube
Volume Total Tube =
Nt
248,8871 in3
= 791
3,14
2 ×11,0847
=
√
3
3,14
= 75,19in = 6,2ft = 1,91m
W steam
Gs =
as
50412,4194 lb/jam
=
2,3768 ft 2
= 21209,78853lb/jam ft2
0,55 1/3
0, 5055 0,0671 x 33,39 0,5055 x 0,0641
= 0,36 (
0, 0671 0,0641 ) ( 0,5055 )
= 7,689214965btu/jamFt2f
12 L
(N+1) = = 16,30
B
f. Gs2 .IDs. ( N+1 )
∆ Ps =
5,22.10 10 .De.Sg. φs
0,001 9 x ( 54.576,9157 ) 2 x 6,2939 x16,30
=
5,22 x 10 10 x 0,0671 x 1 x1
= 0,0250psi
Tebal shell
Spesifikasi bahan stainless steel SA 167 grade 11 type 316
Tekanan yang diijinkan (f) = 18.750 psi
Efisiensi sambungan (E) = 0,8 (double welded joint)
Corrosion allowanced = 0,25 in
Tebal shell dihitung dengan persamaan
Tebal shell dihitung dengan persamaan
P.r
ts = +C
(f.E-0,6P)
44,0877 ×37,7636
= + 0, 125
( 18750 ×0,8 ) -(0,6 × 44,0877)
= 0,2361 in
ts : tebal shell, in
P : tekanan dalam reaktor, psi
r : jari-jari dalam shell = ½ x IDs = 0,5 x 75,5273 in = 37,7636 in
E : efisiensi pengelasan ; 0,8
C : faktor korosi 0,25
f : allowable stress, psi
( Brownell& Young.1979)
1 78
w =
4
x (3 +
√
4,75
)
= 1,7631in
Ca0
ln =k t
(1-x)
Ca 0
ln =kt
(1- 0,98)
1
ln =k t
(0,02)
ln 50 =k t
3,9120 =1082,0380
t =0,0036 jam=13,01 detik
Sehingga volume reaktor :
Fa 0 dXA = ( -ra ) Dv
V t
=
Fa o Ca0
V 0,0036
=
66,5492 kmol/jam 0,0488
V =11,0847 m 3
9. Nozzle Umpan dan Steam pada Reaktor
Saluran dibuat dengan menggunakan bahan carbon steel. Diameter
optimum tube yang carbon steel dan alirannya turbulen (Nre > 2100) dihitung
dengan persamaan :
di opt = 226. G 0,5. Ρ-0,37 (Brownel,1959)
Dengan
Di opt = diameter dalam pipa, mm
G = kecepatan aliran massa fluida, kg/s
P = densitas fluida, kg/m3
a. Nozzle Umpan
1. Nozzle Aliran Bahan Baku Masuk
Diketahui :
G = 4162,8311kg/jam = 1,1564 kg/s
ρ = 2,6779kg/m3
µ = 0,0154cp
maka :
di opt = 266. G 0,5. Ρ-0,37
= 266 (4162,8311kg/jam)0,5 (2,6779 kg/m3) -0,37
= 168,7958mm (6,6455in)
Dari tabel 11 (kern,1965) diperoleh
Nominal pipe size = 8 in
Schedule number = 40
OD = 8,625 in = 0,2191 m
ID = 7,981 in = 0,2027 m
Flow area per pipe,a’ = 50 in2 = 0,0333 m2
Spesifikasi nozzle standar (Brownell and Young, 1959,App F item 1 dan 2 hal
349)
Size = 8 in
OD of pipe = 8,625 in
LC-226
b. Nozzle Produk
1. Nozzle Aliran Produk
Diketahui :
G = 4162,8311kg/jam = 1,1564 kg/s
ρ = 1,447kg/m3
µ = 0,021410cp
maka :
di opt = 266. (1,1564)0,5. (1,447)-0,37
= 211,9718mm (8,3453in)
Dari tabel 11 (kern,1965) diperoleh
Nominal pipe size = 10 in
Schedule number = 40
OD = 10,75 in = 0,2730m
ID = 10,02 in = 0,2545m
Flow area per pipe,a’ = 78,8 in2= 0,0525m2
=941977,1481(turbulen)
Maka anggapan menggunakan turbulen adalah benar
Spesifikasi nozzle standar
Size = 10 in
OD of pipe = 10,75in
Flange nozzle thickness (n) = 0,5in
Diameter of hole in reinforcing plate (DR) = 8,875in
Length offside of reinforcing plate, L = 24,5 in
Width of reinforcing plate, W = 30,125in
Distance, shell to flange face, outside, J = 10 in
Distance, shell to flange face, inside, K = 8 in
Distance from bottom of tank to center of nozzle
- Regular, type H = 15 in
- Low, type C = 12,25 in
G ID
NRe =
a' µ
22866,6888 ( 0,0525 )
= 3,35 ( 0,899 )
=13.523,45506(turbulen)
Maka anggapan menggunakan turbulen adalah benar
Spesifikasi nozzle standar
Spesifikasi nozzle standar (Brownell and Young, 1959,App F item 1 dan 2 hal
349)
Size = 2 in
OD of pipe = 2,38 in
Flange nozzle thickness (n) = 0,218 in
Diameter of hole in reinforcing plate (DR) = 2,5 in
Length offside of reinforcing plate, L = 10 in
Width of reinforcing plate, W = 12,625 in
Distance, shell to flange face, outside, J = 6 in
Distance, shell to flange face, inside, K = 6 in
Distance from bottom of tank to center of nozzle
- Regular, type H = 7 in
- Low, type C = 3,5 in
d. Nozzle Steam Keluar
Diketahui :
G = 22.866,6888Kg/jam = 6,351858kg/s
ρ = 997 Kg/m3
µ = 0,0265 cp
maka :
di opt = 266. (6,3518)0,5. (997)-0,37
= 44,26307901mm (1,79 in)
Dari tabel 11 (kern,1965) diperoleh
Nominal pipe size = 2 in
Schedule number = 40
LC-229
OD = 2,38 in = 0,0604 m
ID = 2,067 in = 0,0525 m
Flow area per pipe,a’ = 3,35 in2 = 0,0022 m2
Pengecekan bilangan reynold
G ID
NRe =
a' µ
22866,6888 ( 0,0525 )
= 3,35 ( 0,899 )
=13.523,45506(turbulen)
Maka anggapan menggunakan turbulen adalah benar
Spesifikasi nozzle standar
Spesifikasi nozzle standar (Brownell and Young, 1959,App F item 1 dan 2 hal
349)
Size = 2 in
OD of pipe = 2,38 in
Flange nozzle thickness (n) = 0,218 in
Diameter of hole in reinforcing plate (DR) = 2,5 in
Length offside of reinforcing plate, L = 10 in
Width of reinforcing plate, W = 12,625 in
Distance, shell to flange face, outside, J = 6 in
Distance, shell to flange face, inside, K = 6 in
Distance from bottom of tank to center of nozzle
- Regular, type H = 7 in
- Low, type C = 3,5 in
LC-230
44,17629
√
= 47,08338635 0,75(
12.650
)
= 2,4096in
Diambil tebal standart t = 2,4 in
dengan
Cph = konstanta design =1,1
Dp = diameter shell47,0833 in
ΔP = perbedaan tekanan 0,052
λ = ligament efficiency = 0,5
f = maximum allowable stress = 12.650 in
c = corrosion allowance = 0,25 in
bahan konstruksi seperti yang digunakan sebagai bahan shell yaitu stainless steel
SA 167 grade 11 type 316
ΔP
tp = Cph . Dp.
√ λf
+C
0,052
= 1,1 (47,0833)
√ 0,5 ( 12.650 )
+ 0,25
= 0,398501822
= 0,5 in
12. Innert Ballast
Alat ini digunakan untk melindungi permukaan katalisator dari pengaruh
langsung aliran fluida dan meratakan aliran fluida umpan.Innert ballast berupa
bola-bola keramik dengan tebal tumpukan 0-6 in, digunakan tinggi tumpukan 6 in.
13. Distributor
LC-233
y−P . m
do/di =
√ y −[ P ( m+1 ) ]
pers 12.2 Brownell and
Young 1959)
dimana :
do = diameter luar gasket, in
di = diameter dalam gasket, in
y = yield stress, lb/in2 (fig 12.11)
m = faktor gasket (fig 12.11)
digunakan material gasket yaitu soft steel, dari Fig 12.11 Brownell and Young
diperoleh :
y = 18.000 dan m = 5,5
sehingga
y-P.m
do/di =
√ y-[P ( m+1 ) ]
N 0 ,04726
bo = = = 0,0236in b=bo jika bo<0,25
2 2
sehingga b = 0,0236in
Wm2 = Hy
=πxbxGxy
= 3,14 x 0,0236x 76,0469x 18.000
= 101566,5241lb
Keterangan :
Hy = berat beban bolt maksimum (lb)
b = effective gasket (in)
G = diameter gasket rata-rata (in)
Berat untuk menjaga joint tight saat operasi digunakan persamaan 12.90 Brownell
Hp =2bπGmp
= 2 x 0,0236x 3,14 x 76,0469 x 5,5 x 44,0877
= 2736,4543lb
Keterangan :
Hp = beban join tight (lb)
m = faktor gasket (fig 12.11)
b = Effective gasket (in)
G = Diameter gasket rata-rata (in)
P = Tekanan operasi (psi)
Beban dari tekanan internal dihitung dengan persamaan 12.89 Brownell & young
(1959).
π G2
H = P
4
3,14 ( 76,0469 )2
H = 44,0877
4
= 200147,748lb
LC-236
Beban operasi total dihitung dengan persamaan 12.91 Brownell & young (1959).
Wm1 = H + Hp
= 200147,748 lb + 2736,4543lb
= 202884,2024lb
Berdasarkan perhitungan diatas, diperoleh Wm1 lebih kecil daripada Wm2, sehingga
beban pengontrol berada pada Wm1 = 79158,93862lb
Wm1 = beban berat bolt pada kondisi operasi (lb)
Wm2 = beban berat bolt pada kondisi tanpa tekanan dalam (lb)
H = total joint contact surface (lb)
Hubungan lever arm diberikan pada persamaan 12.101, Brownell & Young
(1959).
hg = ½ (BC-G)
LC-238
= ½ (77,4748–76,0469)
= 0,7139in
Keterangan :
hG = tahanan radial circle bolt (in)
BC = bolt circle diameter (in)
G = diameter gasket rata-rata (in)
= 147437,4955lb.in
Perbedaan antara flange-design bolt load dengan hydrostatic end force total
adalah
HG =W–H
= Wm1 – H
= 202884,2024lb –200147,748lb
= 2736,4543lb
Momen komponen dihitung dengan persamaan 12.98 Brownell &Young :
MG = HG x hG
= 2736,4543lb x 0,7139in
= 1953,6357lb-in
Momen komponen hydrostatic end force total dan hydrostatic force end pada luas
area dalam flange, HT (persamaan 12.97 Brownell &Young)
HT = H – HD
= 200147,748 lb - 199899,0567lb
= 248,6912lb
Hubungan lever arm, hT (persamaan 12.102 Brownell &Young,1959):
hT = ½ (hD + hG)
= ½ (0,7375+ 0,7139)
= 0,77257in
The moment (persamaan 12.97 Brownell &Young, 1959).
MT = HT x hT
= 248,6912lb x 0,77257 in
= 180,4863lb-in
Jumlah moment untuk kondisi saat beroperasi, Mo (persamaan 12.97 Brownell
&Young ,1959).
Mo = MD + MG + MT
= 147437,4955+ 1953,6357+ 180,4863
= 149571,6176lb-in
Sehingga moment saat beroperasi sebagai pengontrol :
LC-240
Mmax = Mo = 149571,6176lb-in
ts = 0,4521 in
P desain = 44,087 psi
P ×d
f ap =
4 (ts-C)
44,087 psi × 75,52
f ap =
4 (0, 4521 -0,25)
f ap = 4117,80767 psi
Keterangan:
f ap = stress aksial sheel (psi)
d = diameter dalam shell (in)
P = tekanan desain (psi)
ts = tebal shell menara (in)
C = corrosion allowance (in)
f dead wt shell = (X × ρs)/144 (Pers 9.3a, Brownell and Young 1959)
= 3,4 X
Isolator
Isolator yang digunakan adalah asbestos and bonding karena temperatur operasi
dalam reaktor besar, memiliki konduktivitas termal yang kecil sehingga efektif
sebagai isolator.
Diketahui:
Dins = diameter termasuk isolator
Wins = berat isolator
ρ ins = densitas isolator = 18 lb/ft3
t ins = tebal isolator = 0,06 ft = 0,72 in
π
W ins = × Dins 2 ×X ×t ins × ρ ins
4
3,14
W ins = × 6,35332 ×X × 0,06 × 18
4
W ins = 34,2209 X lb
ρ ins X t ins
f dead wt ins = (Pers 9.4a, Brownell and Young 1959)
14 4 (ts-C)
18 X 0,06
f dead wt ins=
14 4 (0, 4521-0,25)
f dead wt in s = 0,03 X
Attachment
W top head =418,8917 lb
Wt tangga (asumsi) = 25 lb/ft
Wt pipeover head vapor line (NPS 2 in, OD 2 in)
= 3,36 lb/ft (Apendix K, Brownell and Young 1959)
Wt shell = 2341,30 lb
Wt total = W top head + Wt tangga + Wt shell + Wtpipa
= 418,8917 + 2364,6774 X
f dead wt attechment =
∑ Wt of att
π Dm (ts-C)
418,8917 + 2364,6774 X
f dead wt attechment =
3,14 × 75,93 (0, 4521 - 0,25)
346,3776 + 78,5840 X
f dead wt attechment =
48,1982
f dead wt attechment = 8,69100 + 49,1651 X
LC-243
n = (2x-4 +1 )
x
n = -1
2
Wt tray = 40 lb/ft
f dead wt attechment =
∑ Wt of att
12 π Dm (ts-C)
x π× D 2
=
( )
2
-1 × 40 ×
4( )
12 π Dm (ts-C)
x 3,14 × 6,32
=
( )
2
-1 × 40 ×
4 ( )
12 × 3,14 × 6,3 (0,4521 - 0,25)
x
=
( 2 )
-1 × 1246,266
48,2302
fc max berdasarkan yield point (Tabel 3.2, Brownell and Young 1959)
yield point = 50.000 psi
= (1/3) y p
= 16.666,6667 psi
= 1,5 × 106 (t/r) ≤ (1/3) y.p
= 1,5 × 106 × (0,4521/27) ≤ (1/3) y.p
= 25119,8289 psi > 16.666,6667 psi
= 56872,9447 lb. ft
t =14,06 in
Digunakan ketebalan skirt15 in
But welding
Tebal skirt
LC-248
Gambar C.44Skirt
d. Desain Anchor Bolt
Vertikal vessel harus merekat erat pada concrete fondation, skirt atau yang
lain dengan anchor bolt dan base (bearing) ring. Jumlah anchor bolt harus 4 atau
kelipatanya untuk setap vertikal vessel. Pada vessel yang tinggi sebaiknya
menggunakan 8 buah anchor bolt. Agar mareka kuat pada concrete pondation,
anchor bolt sebaiknya tidak dipasang terlalu dekat yakni tidak kurang dari 18 in.
Pada vessel diameter kecil agar jarak minimal dari anchor bolt terpenuhi,
sebaiknya menggunakan conical skirt atau wider base ring with gussets, atau
anchor bolt chair.
B = 5 in
C = 3,5 in
D = 0,75 in
E = 1,75 in
F = 2,25 in
G = 2,5 in
f. Penentuan Manhole
Ukuran standar 20 in berdasarkan rekomendasi API Standar 12 C (B&YY 1959
Appendix F item 4)
LC-250
H2O
C3H8O
C3H6O
H2
H2O
C3H8O
C3H6O
H2O
Solven
Komponen
kg/jam % Massa kgmol/jam % Mol
H2O 17.163,4851 1,0000 952,7277 1,0000
17.163,4851 1,0000 952,7277 1,0000
TOTAL
37.838,6192lb/jam 1,0000 2.100,3835lb/jam 1,0000
Keterangan:
P : Tekanan umpan masuk = 2 atm
T : Suhu umpan masuk= 303,15 K
R : 0,0821 atm m3/kmol K
4.162,8311
V1 = ..........................................................................(C.200)
29,5566
= 140,8425 kg/jam
= 310,5013lb/jam
17.163,4851
b. Umpan solvent rate = ...................................................(C.201)
18,0151
= 952,7277 kmol/jam
= 2100,3835 lbmol/jam
c. Umpan aseton yang masuk
y1 = 0,4631
y1
Y1 = ...................................................................................(C.202)
1-y 1
0,022171
=
1-0,022171
= 0,0227
y2 = V1 x Aseton tidak terserap (D.68)
= 140,8425 x 0
=0
y2
Y2 = ....................................................................................(C.203)
1-y 2
0,00
=
1- 0,0
=0
65,2183
X1 = .........................................................................(C.204)
1. 017,9460
= 0,0641
X2 =0
h. Laju alir minimum
Gmin = Y1 – Y2 ....................................................................................(C.205)
= 0,8624 - 0
= 0,8624
Lmin = X1 – X2.................................................................................(C.206)
= 0,0641 - 0
=0,064
Data Equilibrium
Jadi :
( 1- 0,28 ) - ( 1- 1,02271 )
= ( ln [ ( 1- 0,21 ) - (1- 1,02271 ) ] )
LC-259
( 1- x i1) - ( 1- x1 )
(1-x)im =
( )
ln [ ( 1- x i1 ) - ( 1- x 1 ) ]
........................................................(C.208)
( 1- 0,28 ) - ( 1 - 0,343682161 )
= (
ln [ ( 1- 0,38 ) - ( 1 - 0,343682161 ) ] )
=2,711835 (Geankoplis,1983 per 10.4-6)
5. Menentukan Koefisien Film Untuk Penyerapan Aseton
Dipilih 25,4 mm (1 in), keramik intalox rashing ring dari tabel 11.2
packing factor (Fp) adalah 525 m-1 (1722,4409 ft-1) dan Surface are (a) adalah 190
m2/m3 (623,3607 ft2/ft3) (Coulson, 1983, hal: 591).
T : 318,15 K = 113oF
Nilai dari ∑ va dan ∑ vb didapat dari Tabel 6.2-2 volume diffusi atom.
LC-261
∑ vaC H O
3 8 =3(16,15) + 8(1,98) + 1(5,48) = 69,77
∑ va C H O
3 6 =3(16,15) + 6(1,98) + 1(5,48) = 65,81
∑ vaH O
2 =2(1,98) + 1(5,48) = 12,7
∑ v bH 2 = 7,07
1 1
DAB =
1 x 10-7 . T1,75 ( Ma
+ ² )
M b ...............................................(C.210)
1/3 1/3
P [( ∑ va ) + ( ( ∑ yb ) ]²
DAB =
1 x 10-7 . 318,151,75 (1136,1910 + 1138,2071 ) ² 2
1/3 1/3
P [ ( 148,28 ) + ( (7,07 ) ]
(Geankoplis,1983pers 6.2-45 hal 396)
= 0,00000278236 m2/s
= 0,00002994907 ft2/s
µ
Nse = ..................................................................................(C.211)
ρ D AB
0,0000082 kg/m.s
= kg
4,9893 .x 0,00000139118 m 2 /s
m3
= 1,181382117
Data diketahui:
α = 0,557
β = 0,32
γ = -0,51
GY = 0,814
GX = 20,34
HG = α G βY G γX N 0,5
se ........................................................................(C.212)
µ
Nse =
ρ D AB
...................................................................... (C.213)
0,0011 kg/m.s
=
997,9860 kg/ m3 x 1,02359E-06 m 2 /s
= 1,0768
Kemudian subsitusikan ke persamaaan 10.8-3, menggunakan data dari
Tabe10.8-2.
GX
- HL =ϴ ( )
µL
.................................................................... (C.214)
ꬼ = 0,22
Gx = 20,34
μl = 0,0011
HL =ϴ (GµL ) ...............................................................................(C.215)
X ꬼ
20,34
= 2,35 X 10-3 ( 0,0011 ) ꬼ
= 0,0212 m = 0,0695 ft
Konversi Kya dan Kxa menggunakan persamaan 10.6-36 dan 10.4-24
GY
K`ya = ( )
HG
........................................................................................(C.216)
0,814
= 58,08 )
(
0,1219
= 0,1149
GY
K`xa = ( )
HL
....................................................................................(C.219)
20,34
= 18,0151 )
(
0,0212
= 53,3144
m’ = 0,0011
LC-264
Pada nilai ini kecepatan gas akan menjadi sekitar 80 persen dari kecepatan
flooding. Nilai desain yang direkomendasikan, mm air per packingadalah absorber
dan stripper 15 hingga 50 (Coulson,1983 hal 602).
Maka : pada flooding K4 = 1,1 dan FLV0,0761, makaK4=0,645(Coulson,1983.
Fig11-44 hal 603)
b. Persentase flooding
K4
Persentase flooding =
√ Pada FloodngK4
x 100%.........................(C.227)
0,645
=
√ 1,1
x 100%...........................................(C.228)
= 76,5744 %
c. Kecepatan flooding
ρl− ρv
uf= K4
√ ρv
..................................................................................(C.229)
Keterangan:
uf =Kecepatan flooding (m/s)
K4 = Konstanta
Kecepatan flooding bagian atas :
ρl− ρv
uf = K4
√ ρv
........................................................................(C.230)
ρv
column area required= ...............................................................(C.232)
VW
0,3403
=
0,1703
= 1,9982 m2= 21,5009 ft2
b. Diameter
4
D =
√ П
x column area required..................................(C.234)
4 x 1,9982
=
√ 3,14
= 1,5955 m = 62,8134 in
c. Kolom area
П
S = x D2 ...................................................................(C.235)
4
П
= x 1,59552
4
= 1,9982 m2= 21,5009 ft2
d. Tingggi Packed
V1
V1` = ......................................................................................(C.236)
s
4.162,8311 kgmol/jam
=
1,9982 m 2
= 2.083,2688 kg/jam.m
G min
V2` = 1 - y ................................................................................(C.237)
2. S
0,8624 kg/jam
=
1 - 0 . 1,9982 m 2
= 0,4316 kg/jam.m2
V1`+ V2`
V` = ..............................................................................(C.238)
2
LC-268
2.083,2688+0,4316
= kg/jam.m2
2
= 1.041,8502 kg/jam.m2
V`
z = ......................................................................(C.240)
K` YA . 3600
1.041,8502 kgmol/jam.m 2
=
0,1149 kg/mol/s.m3 . 3600 s
= 2,5210 m = 99,2529 in
L
HOL= ........................................................................................(C.243)
K Xa S
(Geankoplis, 1983 pers 10.6-39)
L
HOL = ....................................................................... (C.244)
K Xa S
= 0,0339 m= 1,3346 in
LC-269
Menghitung diameter:
4. Ac
Dc =
√ π
...................................................................(C.250)
4 x 2,6627 m 2
Dc =
√ 3,14
= 1,8417 m = 72,5092 in
Keterangan:
Th = tebalhead (in)
Icr =inside corner radius (in)
R = radius of dish (in)
Sf = straight flange (in)
OD = diameter luar (in)
ID = diameter dalam (in)
B = depth of dish (in)
OA = tinggihead (in)
a. Menentukantebalshell
Data perhitungan:
Poperasi = 2 atm
Pdesign = 1 atm x Poperasi..........................................................(C.252)
= (14.6959 x 2) Psi
= 35,2560 psi
Material Stainless steel SA 167 Grade 11 type 316 (alasan pemilihan
material: tahan terhadap korosifitas danmemiliki struktur kuat)
f =18.750 psi (BrownellandYoung, 1959)
c =0,125 in (BrownellandYoung, 1959)
E =0,85 (BrownellandYoung, 1959, Tabel 13.2)
LC-272
D =60 in =1,58115 m
R = 30in
P.ri
ts = + c ...........................................................(C.253)
f.E-0,6.P
35,2560 psi x 36,2546 in
= + 0,125 in
12.650,00 psi x 0,80-0,6( 35,2560 psi)
= 0,3766 in (Brownel, 1959)
Digunakan tebal standar untuk shell :1/2 in
Keterangan :
ts = tebal shell (in)
P = tekanan operasi (psi)
f =allowable stress (psi)
r = jari-jari shell (in)
E = efisiensi pengelasan
c = faktor korosi (in)
1 rc
w=
4 ( √ )
3+
icr
(C.255)..................................................................... =
1 3,2500
4( √
3+
54,00 )
= 1,7690 in
Jenis tutup yang dipilih : Flanged standart dished head
Bahan konstruksi :Stainless steel SA SA 283 Grade C
LC-273
2
= rc – (rc−icr)2 – ( ID −icr ) ..................................................(C.257)
b
√ 2
= 54,0000 – √ (54,0000 – 3,2500)2 – ( 72,5092 - 3,2500)2
= 15,4480in = 0,3924m
AB = ri – icr ................................................................(C.259)
= (36,2546 – 3,2500) in
= 33,0046in = 0,8383 m
BC = rc – icr ..............................................................(C.260)
= (54,00 – 3,25)
LC-274
= 50,75 in = 1,2891m
AC = √ BC 2 – AB 2...........................................................(C.261)
= √ (50,7500)2 – ( 33,0046 )2
= 38,5520 in
d. Tinggi Menara
Data perhitungan :
Diameter kolom (Dt) =1,8417 m = 72,5092 in
Luas kolom (Ac) = 2,6627 m2= 28,6508 ft2
Volume head = 0,000049 Dt3
= 0,000049 (1,8417)3
= 0,0003 m3
π
Volume head padasf= x ID2 x sf ..................................................... (C.262)
4
3,14
= x ( 72,5092 in)2 x 3 in
4
= 12.381,6007 in3 = 0,2029 m3
Volume total head = Volumehead + Volume head padasf
=0,0003m3 + 0,2029 m3
= 0,2032 m3
L
Q= ............................................................................... (C.263)
ρL
17.163,4851 kg/jam
= = 0,2866 m3/menit = 17.6 m3/s
998 kg/m3
Waktu tinggal cairan dibawah plate terakhir 5-10 menit (Ulrich, 1984)
Waktu tinggal cairan dipilih = 5 menit
Vcairan = Q x waktu tinggal.............................................................(C.264)
= 0,50 m3/menit x 5 menit
= 2,5 m3= 88.28 ft3
Tinggi cairan dalam shell (HL)
π
Vcairan= x Dc 2 x HL.........................................................................(C.265)
4
Vcairan
HL= π
x (Dc)2
4
1,4332 m3
= 3,14 x ( 1,8417 )2
4
=0,5382 m = 21,1905 in
Menentukan tinggi menara
Jarak Packed = 0,5 m = 1.64042 ft
Jarak dari Packed Teratas =1m = 3.28084 ft
Jumlah packed =2
Tinggi packed = 2,304 m = 7.55906 ft
Tinggi head dengan tebal head = OA – sf................................(C.266)
= 18,8644 m– 3,0000 m
= 15,8644 in = 0,4030 m
Tinggi dibawah packed = HL + (OA – sf)...................(C.267)
= 0,5382 m+0,4030 m
= 0,9412 m = 37,0568 in
Tinggi total = Jarak dari packed teratas + (jumlah paked x jarak packed)+
Tinggi packed + Tinggi head dengan tebal head + Tinggi di
bawah packed terbawah
LC-276
a. Lebar gasket
d0 y-p.m
di
=
√ y-(p ( m+1 ) )
............................................................(C.267)
c. Flange
Perhitungan diameter flange luar :
Flange OD (A) = bolt circle diameter (BC) + 2 E
Flange OD (A) = 63,05 in + (2 x 0,75000) in = 64,550 in2
Perhitungan tebal flange :
y.P
t =
√ f aB
.........................................................................(C.269)
m
Q= ...............................................................................................(C.270)
ρL
LC-278
9.177,3744 lb/jam
= lb = 8,1846 ft3/s
0,3115 x 3600 s
ft 3
m
Q= ...............................................................................................(C.278)
ρL
37.838,6192 lb/jam
= lb = 0,1687 ft3/s
62,3023 x 3600 s
ft 3
Low, Type C = 6 in
18. Ukuran Packing
Packing merupakan bahan isian yang digunakan sebagai alat kontak antar
fasa dalam kolom pemisah.
Berdasarkan (Coulson,1983 hal 592) dengan diameter lebih dari 0,9 m
ukuran packing adalah:
Ukuran packing : 65 mm = 2.5591 in
Strukutur packing : Random
HETP : 0,35 m = 114.8294ft
Jenis Packing : Ceramic, Rashing Ring
Kelebihan rashing ring
1. Harganya lebih murah
2. Tidak terlalu berat
3. Dapat digunakan untuk bahan yang tidak tahan suhu tinggi.
Gambar data aktual packing dapat dilihat pada gambar C.50
Sumber : (Bar Grid Support. Used By Mission of U.S. Stoneware Co.Now Norton
Chemical Process Products Corp)
Diameter : 60 in
Diameter packed : 58 in
Overall height : 9 in
Support ledge : 2 in
LC-285
Menentukan weir flow distributor dimensi pdapat dilihat pada gambar C.55
.Gamba
r C.53 Dimensi Weir Flow Distributor
Sumber : (weir flow distributor. Used By Mission of U.S. Stoneware Co.Now
Norton
Chemical Process Products Corp)
Diameter : 60 in
Diameter packing (A) : 50 in
Overall diameter (B), dan (C) : 58 in , dan 6 in
LC-286
d. Berat aksesoris Pada Reaktor diambil dari (Brownel and Young,1983 item
2 hal 390).
- Nozzle umpan masuk
OD = 2,8750 in
Berat = 10 lb = 4,5359 kg
OD = 2,8750 in
Berat = 10 lb =4,5359 kg
- Nozzle feed gas keluar
OD = 2,8750 in
Berat = 10 lb =4,5359 kg
- Nozzle umpan feed liquid keluar
OD = 2,8750 in
Berat = 10 lb =4,5359 kg
Berat Total = Berat shell + Berat Head dan Bottom + Berat packed
+ Nozzle umpan masuk + Nozzle umpan liquid masuk
+ Nozzle umpan feed gas keluar+ Nozzle umpan liquid keluar
Berat Total = 102,24610 kg + 134,880708 kg + 103,82 kg + 28,758 kg
+ 4,894 kg
= 398,4628 kg = 878.45906 lb
23. Desain Sistem Penyangga
Skirt adalah penyangga yang digunakan dan paling aman untuk penyangga
vertikel vessel. Skirt disatukan dengan vessel menggunakan pengelasan kotinyu,
ukuran pengelasan ditentukan berdasarkan ketebalan skirt. Ketebalan skirt harus
mampu untuk menahan berat mati dan bending moment dari vessel. Ketebaan
skirt harus lebih dari 6 mm.
a. Momen pada base
Penentuan besarnya momen pada base menggunakan persamaan berikut:
M = Pw x Dis x H x hi.........................................................................(C.287)
Keterangan :
Pw = wind pressure = 25 lb/ft2 (Brownell dan yaoung 1959, Tabel 9.1)
Dis = diameter vessel dengan isolatornya = 1,8417 m
H = tinggi menara total = 5,6483 m
hi = levell arm = H/2 = 5,6483 m / 2 = 2,8241 m
M = Pw x Dis x H x hi
= 122,0607 kg/m2 x 1,8417 m x 5,6483 x 2,8241 m
= 3.585,9201 m/kg
LC-288
= 0,1058 m = 4,1643 in
Tebal skirt dan penyambungan kolom dan skirt dapat dilhat pada gambar berikut:
LC-289
= 1.163.008,71 kg/m
b. Menentukan area bolt
Penentuan besarnya area bolt dapat menggunaan persamaan sebagai
berikut:
TC B
B4 = .......................................................................................(C.291)
SB N
Keterangan :
T = maximum tension dari bolt = 1.163.008,71 kg/m
SB = maximum allowable stress value dari material bolt bahan (SA-307)
= 15000 psi (Megsysey,2001)
CB =cicumference pada lingkaran bolt = 94 in = 2,3876 m
N = jumlah anchor bolts = 8 buah
TC B
B4 = ..................................................................................(C.292)
SB N
1.163.008,71 x 2,3876
=
15000 x 8
= 0,2984 m
Dipakai bolt area seluas = 0,2984 m
Area bolt 0,890 in2 maka ukuran bolt = 1 ¼ (Tabel A Megyesy, 2001)
Bolt root area = 0,551 in2
LC-291
π d2 t ρ
Bebanhead = x ..............................................(C.295)
4 1728
3,14 ( 73,26 in)2 (0,25 + 1,306 ft) 490 lb/ft 3
= x
4 1728
= 1.858,8907 lb
26. Pemeriksaantebalshell
1. Stress padakondisioperasi
a. Perhitunganstress aksialdalamshell:
di = 73,26 in
ts = 0,37 in
Pdesign = 35,26 psi
Pxd
fap= ........................................................................................(C.296)
4 (ts-c)
35,26 psi x 73,26 in
=
4 ( 0,37 in- 0,125 in)
= 2.582,83 psi (pers 3.13, Brownel,1959)
b. Perhitungan berat mati (dead weights)
Shell
Diketahui :
Do =Diameter luar shell = 73,26 in(tanpa isolator)
Di =Diameter dalam shell = 72,51 in
ρ s =densitasshell =490,05 lb/ft3
π
Wshell = x (Do – Di) x ρ x X (Pers. 9.1, Brownell,1959)
4
Wshell = 288,52 X
fdead wt shell = 3,4 X (Pers. 9.3a, Brownell,1959)
X = Jarak dari puncak ke bawah
LC-294
Isolator
Diketahui:
Dins = 1,84 m
ρ s in = 18 lb/ft3
tins = 3 in
π
Wins = x (Dins2) x X x tins x ρins
12
Wins = 128,91 X (lb)
ρins x ( X) x t
fdead, ins = ins
(Pers. 9.4a, Brownell,1959)
144 x (ts-c)
fdead, ins = 1,07 X
Attachment
Wt isolasi = 89,39lb/ft
Wt top head = 310,30 lb
Wt tangga = 25 lb/ft (pp.157, Brownell, 1959)
Wt over head vapor line = 28,56 lb/ft (App.K,157, Brownell,1959)
Total Wt = 53,5600 + 310,30 X
Dari Pers. 9.6, Brownell and Young, 1959:
Σweight of attachment
Fdead wt atch =
12 x π x Dm x (ts-c)
fdead wt attachment = 2.679,08 + 14,45 X
2. Perhitungan stress karena beban angin
P angin = 25 lb/ft2
deff = 32,98 in
Fwx = 0,78 X2
3. Perhitungan stress gabungan pada kondisi operasi
c. Kombinasi stress dalam pengaruh angin
- Up wind side, f Tensile
Ft(max) = fwx - fdw
= 0,7813 X^2 + 2679,0784 +14,4543 x
F = 11.650
LC-295
E = 0,8000
fallowable = f x E
= 10.120 Psi
Kemudian
= 0,7813 X2 +14,4543 x+ 2679,0784 = 10.120 Psi
= 8,11 X2 + 2,99 X – 10.113,31 = 0
= X2 + 0,3687 X – 1.247,02
-b± √ b 2 - 4ac
X =
2a
X = 77,50 ft
= 23,62 m (Eq.9.78, Brownell and Young, 1959)
- Up wind side, f compresi (fc)
Ft(max) = fwx – fap + fdx
= 0,7813 X2 +14,4543 x+ 2679,0784
Fc = 1,5 x 106 (t/r) ≤ 1/3 y.p
Keterangan :
t = ketebalan shell = 0,25 in
r1= jari-jari dalam shell = 27,15
yield point = 50.000 psi (Tab 3.2 Brownell and Young
1.959)
1/3.y.p = 16.666,67 psi
Fc = 13.814,36 ≤16.666,67 psi
Karena fc lebih kecil dari 1/3 y.p maka digunakan fc = 13.814,36 psi
Fc = fc (max)
13.814,36 = 0,7813 X2+ 14,4543 X + 2679,0784
0 = 0,7813 X2 + 14,4543 X - 11135,2816
= X2 + 18,5003 X - 14252,2483
-b± √ b 2 - 4ac
X =
2a
X = 110,49 ft
= 33,68 m (Eq.9.78, Brownell and Young, 1959)
LC-296
3×π
652,7515 ×8
=
√
3
3 x 3,14
= 2,5033 m
= 8,2131 ft
b. Volume Ellipsoidal, Ve
Ve = π/24 × Dt3
= 0,13× (2,5033)3
= 2,0525 m3
= 72,4849 ft3
c. Volume Silinder, Vs
Vs = Vt – Ve
= (18,4729 m3– 2,5033) m3
= 16,4203 m3
= 579,8789 ft3
d. Tinggi Tangki Total, Ht
Tinggi slinder,
H = (3/2) ×Dt
= (3/2) ×2,5033 m
= 3,7550m
= 1,1445 ft
LC-298
Tinggi ellipsoidal,
h = (1/4) ×Dt
= (1/4) ×2,5033 m
= 0,6258 m
= 0,1907 ft
Maka,
Ht = H + h
= (3,7550 + 0,6258) m
= 4,3809 m
= 1,3353 ft
3. Tekanan design
Pabs = Poperasi + Phidrostatis
ρ× h−1
Phidrostatis = ( )
144
= 2,3954 Psi
Poperasi = 1Atm
= 14,7 Psi
Pabs = (2,3954+ 14,7 ) Psi
= 17,0955 Psi
Pdesain = 18,8050 Psi
Maka,
18,8050 psi x 2,5033 m
t= + 0,0032 m
( 13700 psi x 0,85 ) x (0,2 x 57,8069 psi)
t = 0,0071 m
OD= 2t + D
= 2 (0,0072) + 2,5033
= 2,5179 m
= 99,1281 in