00 1/2
Ditetapkan oleh
Endorsed by
Tanggal Terbit Direktur
Standar Prosedur
Date of issue Director
Operasional
Standard Operating
Procedure
Cara melakukan pengujian dan penilain kualitas air yang digunakan untuk perawatan
Pengertian hemodialisis
Understanding How do the testing and assessment of the quality of water used for hemodialysis
treatment
Kebijakan
SK………………….
Policy
Prosedur A. Peralatan
Procedure Equipment
1. Sarung tangan
Gloves
2. Apron
3. Masker
Mask
4. Handrub
5. Alcohol swab
6. Sterile sampel
Sample sterile
7. Ember kapasitas 10 Liter
Pail capacity of 10 liters
8. Test kits:
- Chlorine test kits
- Hardness test kits
9. Post RO membrane
10. Titik pertama dari loop distribusi
First point of the distribution loop
11. Titik akhir loop distribusi (port mesin terakhir)
End point of distribution loop (Last machine port)
12. Post carbon filter 1 & 2
ID-MA-OP-008
REKOMENDASI UNTUK PENGUJIAN AIR
Recommendation for Water Testing
No. Dokumen No. Revisi Halaman
Document Number Revision Number Page
00 2/2
B. Pelaksanaan
Implementation
1. Pastikan unit RO telah beroperasi minimal 10 menit
Make sure the RO unit has been operating for at least 10 minutes
2. Gunakan apron, masker dan lakukan cuci tangan
Use apron, mask dan perform hand hygiene
3. Buka tes poin dan biarkan air mengalir selama 2 menit kedalam ember atau
saat ember telah cukup
Open the test point and let the water run for 2 minutes into the pail or when
the bucket is enough
4. Buka tutup wadah bersih, isi dan bilas di aliran yang mengalir untuk
memastikan wadah bersih.
Open the lid of the container clean, fill and rinse in the flowing stream to
make sure the container is clean.
5. Kumpulkan sampel midstream dan rekap sample segera
Collect samples midstream and recap the sample immediately
6. Lakukan tes yang diperlukan jika menggunakan alat uji
Perform tests are required when using test equipment
Atau
Or
ID-MA-OP-008