Anda di halaman 1dari 24

Dental Unit &

Sterilisator

1
PETUNJUK MENGENAI PERAWATAN, PEMELIHARAAN DAN CARA
MENGGUNAKAN PERALATAN KESEHATAN GIGI
(DENTAL EQUIPMENT)

DENTAL UNIT DAN STERILISATOR

PETUGAS KESEHATAN GIGI DAPAT PETUGAS KESEHATAN GIGI MAMPU


MENGETAHUI, MENGERTI, DAN
MENGETAHUI, MENGERTI DAN MEMAHAMI MEKANISME KERJA ALAT-
MEMAHAMI MEKANISME KERJA ALAT YANG TERDAPAT PADA KURSI
ALAT-ALAT YANG TERDAPAT PADA GIGI, STERILISATOR DAN MAMPU
KURSI GIGI DAN STERILISATOR MENGOPERASIONALKAN SECARA BENAR

2
MACAM-MACAM KURSI GIGI

DENTAL CHAIR

KURSI GIGI/
KURSI LAPANGAN

DENTAL UNIT SEMI ELECTRIC DENTAL UNIT FULL ELECTRIC

3
MEKANISIME KERJA ALAT KEDOKTERAN GIGI
PADA KEPERAWATAN GIGI

REFLECTOR
• PERLENGKAPAN, CARA KERJA ALAT DAN PEMELIHARAAN DENTAL UNIT FULL DAN
SEMI ELECTRIC SBB: DENTAL UNIT :
* LAMPU OPERASI GIGI ( DENTAL OPERATING LIGHT), ADA 2 MACAM :
1. OPERATING LIGHT DENGAN LAMPU HALOGEN BIASA DENGAN BENTUK SEDERHANA
2. OPERATING DENGAN SHADOWLESS LIGHT (LAMPU TIDAK BERBAYANG) DAN COLD
LIGHT HALOGEN (LAMPU HALOGEN DINGIN)

CARA MENYALAKAN OPERATING LIGHT YAITU DENGAN MENEKAN ATAU MENGGERAKAN


KEKANAN ATAU KEKIRI CONTROL SWICTH YANG TERDAPAT PADA OPERATING LIGHT
BODY
CARA PERAWATAN OPERATING LIGHT, CUKUP DENGAN MEMBERSIHKAN REFLECTOR
(PEMANTUL CAHAYA) BAIK PADA BAGIAN DALAM/LUAR ATAU BAGIAN
DEPAN/BELAKANG DENGAN MENGGUNAKAN KAIN LAP LEMBUT DAN KERING
(FLANEL). TIDAK BOLEH MENGGUNAKAN KAIN LAP YANG BASAH ATAU BERMINYAK
KARENA DAPAT MENIMBULKAN FLEK/NODA ATAU TERKELUPAS PADA BAGIAN
REFLECTOR SEHINGGA SINAR YANG DIHASILKAN KURANG SEMPURNA. PADA SAAT
MEMBERSIHKAN REFLECTOR TIDAK BOLEH MENYENTUH/TERSENTUH HALOGEN
LAMP/OPERATING LAMP OLEH TANGAN, KARENA DAPAT MENYEBABKAN HALOGEN
LAMP TIDAK AWET/PUTUS, SEHINGGA TIDAK MENYALA

4
SPITTOON BOWL

SPITTOON FLUSH

WASTE RECEPTACLE

• TEMPAT PEMBUANGAN AIR LUDAH ATAU AIR KUMUR-KUMUR (SPITTOON


BOWL). PADA BAGIAN SPITTOON BOWL DILENGKAPI DENGAN SPITOON FLUSH
(PEMBILASAN PELUDAHAN), NAMUN TERKADANG MASIH JUGA KOTOR PADA
BAGIAN-BAGIAN TERTENTU SEHINGGA PERLU DIBERSIHKAN SECARA RUTIN. CARA
MENYALAKAN SPITTOON FLUSH DENGAN MEMUTAR KRAN KEARAH
KANAN/ARAH JARUM JAM YG TERSEDIA PADA BODY UNIT

• CARA MEMBERSIHKAN MEMBERSIHKAN SPITTOON BOWL DENGAN


MENGGUNAKAN BRUSH ATAU SPONGE (SIKAT HALUS/KARET SEPON) YANG
TELAH DIBERIKAN LARUTAN DETERGENT/VIM DENGAN BUSA YANG HALUS,
KEMUDIAN BILAS DENGAN AIR BERSIH. BERSIHKAN JUGA SARINGAN (WASTE
RECEPTACLE) YANG TERDAPAT PADA SPITTOON BOWL DENGAN CARA MENYIKAT
HINGGA BERSIH.

5
CUPFILLER
HOLDER

CUPFILLER PIPE

• PENGISI GELAS (CUPFILLER)


• CUPFILLER : ALAT YG BERFUNGSI UNTUK MENGISI AIR KEDALAM
GELAS KUMUR PADA DENTAL UNIT SEMI ELECTRIC/ FULL
ELECTRIC SECARA MANUAL ATAUPUN SECARA AUTOMATIC
• CARA PERAWATANNYA : -BERSIHKAN CUPFILLER HOLDER DENGAN
SPONGE (KARET SPON) YG TELAH DIBERIKAN DETERGENT
/VIM, GOSOK SAMPAI BERSIH DAN KERINGKAN UNTUK
MENGHINDARI AGAR HOLDERNYA TIDAK ADA FLEK/
KARATAN. – MEMBERSIHKAN CUFILLER PIPE (PIPA
PEMBUANG AIR) DENGAN SIKAT HALUS (SIKAT GIGI) YG TELAH
DIBERIKAN DETERGENT/VIM SIKAT HINGGABERSIH, APABILA LUBANG
PIPA/SALURAN TERSUMBAT TUSUK DENGAN KAWAT BAJA (FINE WIRE)
YG PANJANGNYA KIRA-KIRA 4 CM HINGGA AIR YG TERGENANG DAPAT
MENGALIR LANCAR LALU SIRAM DENGAN AIR BERSIH DAN KERINGKAN
DENGAN KAIN BERSIH/KERING

6
THREE WAYS SYRINGE

PENYEMPROT AIR DAN ANGIN (THREE WAYS SYRINGE)

• THREE WAYS SYRINGE : ALAT YG BERFUNGSI MENGELUARKAN/


MENYEMPROT AIR ATAU ANGIN, DAPAT JUGA SECARA BERSAMA-
SAMA MENYEMPROTKAN AIR DAN ANGIN UNTUK MEMBERSIHKAN
/MENGERINGKAN CAVITAS (LUBANG GIGI), GIGI DIDALAM
RONGGA MULUT DLL
• CARA PERAWATANNYA : SEHABIS PRAKTEK/BEKARJA, BERSIHKAN
UJUNG LUBANG PADA SYRINGE DENGAN MENGGUNAKAN
KAPAS/KAIN HALUS YG BERSIH, KARENA BIASANYA UJUNG
LUBANGNYA TERTUTUP OLEH KOTORAN/PARTIKEL DARI BAHAN
TAMBALAN ATAU LAINNYA. APABILA TERLALU LAMA TIDAK
DIBERSIHKAN AKAN MENGERAS MAKA BERSIHKANLAH DENGAN
AIR BERSIH MENGALIR DENGAN MENGOSOK2 SECARA PERLAHAN ,
BILA MASIH SULIT DAPAT DIRENDAM DENGAN LARUTAN ALKOHOL
70% - 96% SELAMA, 15 – 30 MENIT LALU BERSIHKAN 7
SALIVA EJECTOR

CUSPIDOR BOWL

ORAL EVACUATOR TIP

• PENGHISAP AIR LUDAH (SALIVA EJECTOR)


SALIVA EJECTOR : ALAT YG BERFUNGSI MENGHISAP AIR
LUDAH DAN DARAH PASIEN PADA SAAT MENGERJAKAN
PREPARASI CAVITAS, PENAMBALAN DAN OPERASI BEDAH
MULUT DITEMPAT KERJA/PRAKTEK
• ALAT BANTU SALIVA EJECTOR (TIP) ADA 2 MACAM :
1. ORAL EVACUATOR TIP YAITU TIP YG DAPAT DIPAKAI
BERULANG-ULANG, TERBUAT DARI STAINLESSTEL/ METAL
(DAPAT DISTERILKAN)
2. DISPOSSIBLE TIP YAITU TIP YG DAPAT DIPAKAI HANYA
SEKALI SAJA/DAPAT DIGANTI-GANTI, TERBUAT DARI
PLASTIK YG DIBERI KAWAT
8
 CARA PERAWATAN ORAL EVACUATOR TIP :

CARANYA BERSIHKAN LUBANG YANG TERDAPAT PADA


UJUNG TIP DENGAN CARA MENYIKAT DENGAN SIKAT
HALUS (SIKAT GIGI) HINGGA BERSIH DARI KOTORAN-
KOTORAN YG MENEMPEL PADA UJUNG TIP TERSEBUT,
SEHINGGA DAYA SEDOT/HISAPNYA KUAT DAN
BERFUNGSI DENGAN BAIK. LAKUKAN PERAWATAN
SECARA RUTIN/BERKALA DENGAN MEMBUKA
SARINGAN YG BERADA DITABUNG EVACUATOR.
BIASANYA KOTORANNYA: DARAH MEMBEKU, SISA-SISA
PREPARASI YG MENGERAS DAN BAHAN TAMBALAN DLL,
SEHINGGA MENGGANGGU FUNGSI SALIA EJECTOR

9
SWITCH / CONTROLS

• FUNGSI DARI SWITCH/CONTROL


1 (TOMBOL-TOMBOL PADA DENTAL
UNIT FULL ELECTRIC) :
2
1. MEREBAHKAN/MENEGAKKAN BACK
REST (SANDARAN KURSI)
3 2. MENAIKAN/MENURUNKAN SEAT CHAIR
(TEMPAT DUDUKI KURSI)
3. MENEGAKKAN BACK REST DAN
MENURUNKAN SEATCHAIR SECARA
BERSAMAAN
4. MENGATUR HEAD REST (SANDARAN
KEPALA)
• CARA MENGOPERASIONALKANNYA
4 YAITU DENGAN CARA MENEKAN
TOMBOL/MENGGERAKKAN KEARAH
BAWAH
• CARA PERAWATANNYA YAITU SELALU
SETELAH SELESAI BEKERJA DILAP
DENGAN KAIN BERSIH DAN KERING
5. ARM REST (SANDARAN TANGAN)
CARANYA ANGKAT/GERAKAN KEATAS
10
11
CARA MERAWAT DAN MEMBERSIHKAN
BAGIAN-BAGIAN DENTAL UNIT :

BAHAN DAN ALAT PERAWATAN;


1. DETERGENT/VIM 5. SIKAT LEMBUT
2. AUTOSOL 6. SPON
3. AIR BERSIH 7. KAIN/HANDUK
4. GAYUNG/EMBER BERSIH DAN KERING

BAGIAN-BAGIAN YG DAPAT DIBERSIHKAN


DENGAN ALAT DAN BAHAN TSB DIATAS :
1. HEAD REST
2. BACK REST
3. ARM REST
4. SEAT CHAIR
5. MOTOR COVER
6. BASE CHAIR
7. SPITTOON BOWL
8. CUPFILLER HOLDER
9. CUPFILLER PIPE
10. BODY UNIT
11. POLE LAMP
12. ARM TABLE
13. TABLE INSTRUMENT
14. PLUMBING BOX
15. FOOT CONTROL 12
• DENTAL COMPRESSOR (KOMPRESOR) : MESIN
DENTAL COMPRESSOR
ANGIN YG BERFUNGSI UTK MENJALANKAN HIGH
SPEED AIRTURBINE HANDPIECE, LOW SPEED
AIR MOTOR HANDPIECE AND THREE WAYS SYRINGE,
UTK ITU ANGIN YG DIHASILKAN OLEH KOMPRESOR
JARUS BENAR-BENAR ANGIN MURNI YG TIDAK
TERCAMPUR AIR. UNTUK MENDAPAT ANGIN MURNI,
USAHANKAN SETIAP HABIS PRATEK BUANGLAH ANGIN
DITABUNG SAMPAI HABIS, DENGAN JALAN MEMBUKA
KRAN/DRAINYG BIASANYA TERLETAK PD BAWAH
TABUNG KOMPRESOR
• CARA PERAWATANNYA :
1. BERSIHKAN KOMPRESOR DENGAN KAIN KERING
2. FILTER (SARINGAN) ANGIN KOMPRESOR SELALU DIBERSIHKAN 1 BULAN
SEKALI
3. BILA KOMPRESOR TERSEBUT MEMAKAI PELUMAS,
PERIKSALAH TIAP HARI KEADAAN PELUMASNYA.
APABILA KURANG SEGERA TAMBAH PELUMAS YANG
TELAH DIANJURKAN

BAGIAN-BAGIAN DENTAL COMPRESSOR

• PRESSURE GAUGE (UKURAN TEKANAN): ALAT YG BERFUNGSI UNTUK


MENGETAHUI TEKANAN DALAM TABUNG KOMPRESOR SESUAI
KAPASITAS ISI KOMPRESOR, DAPAT DIATUR SECARA MANUAL
MAUPUN AUTOMATIC
13
• COMPRESSOR AIR FILTER (SARINGAN ANGIN
KOMPRESOR): SARINGAN ANGIN DARI BUANGAN
MESIN KOMPRESOR

• AUTOMATIC DYNAMO MACHINE(MESIN DINAMO


OTOMATIS) : MESIN PENGGERAK MOTOR UNTUK
MENGHASILKAN ANGIN YANG DISALURKAN DAN
DISIMPAN DALAM TABUNG KOMPRESOR

• AIR DRAIN (SALURAN ANGIN) : KRAN YG DIGUNAKAN UNTUK


MEMBUKA DAN MENUTUP SALURAN ANGIN DARI KOMPRESOR KE
DENTAL UNIT

• ON/OF SWITCH (TOMBOL MATI/NYALA) :


TOMBOL YANG BERFUNGSI UNTUK
MENYALAKAN DAN MEMATIKAN MESIN KOMPRESOR

• TUBING COMPRESSOR (TABUNG KOMPRESOR):


TABUNG BERFUNGSI UNTUK MENGUMPULKAN
DAN MENYIMPAN ANGIN YG DIHASILKANMESIN
KOMPRESOR UNTUK DISALURKAN KE DENTAL UNIT

•AIR DRAIN (SALURAN ANGIN) : KRAN YG


DIGUNAKAN UNTUK MEMBUKA DAN MENUTUP
PEMBUANGAN ANGIN DARI KOMPRESOR, SEBELUM
DAN SESUDAH BEKERJA/PRAKTEK 14
KESIMPULAN
CARA MERAWAT DAN MEMBERSIHKAN
BAGIAN-BAGIAN YANG TERDAPAT PADA DENTAL UNIT
FULL DAN SEMI ELECTRIC
1. ALAT-ALAT YANG ADA/TERDAPAT ARUS LISTRIK
TIDAK BOLEH TERKENA AIR ATAU CAIRAN
2. ALAT-ALAT YANG TERBUAT DARI KULIT
DIBERSIHKAN DENGAN MENGGUNAKAN SIKAT,
AIR, DETERGENT ATAU VIM LALU LAP HINGGA
BERSIH DAN KERINGKAN
3. ALAT-ALAT YANG TERBUAT DARI METAL/BESI
DAN FIBER/PLASTIC YANG DILAPISI OLEH CAT,
BERSIHKAN DENGAN KAIN LAP BASAH LALU
KERINGKAN DAN LAPISI DENGAN CAIRAN
PENGKILAP/AUTOSOL

15
MEKANISIME KERJA ALAT KEDOKTERAN GIGI
PADA KEPERAWATAN GIGI

STERILISATOR

MACAM-MACAM STERILISATOR

• BOILING DISINFECTOR : ALAT UNTUK MENSTERILKAN ALAT-ALAT


KEDOKTERAN GIGI SEMI KRITIS DENGAN CARA REBUS/BASAH, DENGAN
SUHU MENCAPAI 100˚ C
• DRY DISINFECTOR : ALAT UNTUK MENSTERILKAN ALAT-ALAT
KEDOKTERAN GIGI SEMI KRITIS/KRITIS DENGAN CARA KERING/UDARA
PANAS/OPEN DENGAN SUHU MENCAPAI 100 DERJAT CELCIUS
• AUTOCLAP : ALAT UNTUK MENSTERILKAN ALAT-ALAT KEDOKTERAN GIGI
SEMI KRITIS/KRITIS DENGAN CARA TEKANAN PANAS TINGGI DIDALAM
RUANG TERTUTUP

16
BOILING
DISINFECTOR

Sterilisasi
kering

17
• BOILING DESINFECTOR STERILISASI BASAH DENGAN CARA MEREBUS
• PERSIAPAN :
ALAT-ALAT
1. DANDANG/PANCI
2. KOMPOR GAS
3. KORENTANG
4. ALAT-ALAT YANG AKAN DISTERLISASIKAN
BAHAN-BAHAN
1. AIR
2. HANDUK KERING DAN BERSIH

CARA MENSTERILKAN
1. REGULATOR PASANG PADA TABUNG GAS
2. LETAKKAN DANDANG/PANCI DIATAS KOMPOR
3. MASUKAN AIR KEDALAM DANDANG KIRA-KIRA
2-3 CM DARI PERMUKAAN DANDANG, KEMUDIAN TUTUP DANDANG
DENGAN RAPAT
4. NYALAKAN KOMPOR DAN DIDIHKAN AIR HINGGA 100˚ C
5. ALAT-ALAT YANG AKAN DISTERILKAN DICUCI BERSIH, KEMUDIAN
MASUKAN KEDALAM DANDANG DENGAN MENGGUNAKAN
KORENTANG SECARA PERLAHAN. TUTUP KEMBALI DAN TUNGGU
MENDIDIH KIRA-KIRA 15-30 MENIT, SETELAH MENDIDIH MATIKAN
KOMPOR DAN BUKA TUTUP DANDANG AGAR UAP PANASNYA
MENGUAP

18
6. SETELAH UAP AIR PANAS BERKURANG, LALU KELUARKAN ALAT-ALAT DENGAN
MENGGUNAKAN KORENTANG LETAKKAN DIATAS HANDUK KERING, BERSIH, DAN STERIL
7. KEMUDIAN ALAT-ALAT DIKERINGKAN

CARA MERAWAT STERILISASI REBUS


• PERSIAPAN; ALAT DAN BAHAN
1. AIR
2. DETERGENT/VIM
3. SIKAT
4. SPON
5. HANDUK KERING DAN BERSIH
• CARA PERAWATAN/MEMBERSIHKAN
1. AIR SETELAH STERILISASI DIBUANG, LALU ANSANG DIKELUARKAN DARI DALAM
DANDANG, KEMUDIAN DICUCI DENGAN MENGGUNAKAN DETERGENT/VIM , BILA PERLU
SIKAT HINGGA BERSIH
2. KERINGKAN DANDANG DAN ANSANG DENGAN HANDUK KERING DAN BERSIH HINGGA
KERING, KEMUDIAN SIMPAN DILEMARI ALAT
3. KOMPOR LAP DENGAN KAIN BASAH HINGGA BERSIH, KEMUDIAN KERINGKAN DENGAN
HANDUK BERSIH
4. REGULATOR LEPASKAN DARI TABUNG GAS BILA PERLU
MENGETAHUI KERUSAKAN DAN CARA MENGATASINYA :
1. APABILA ADA MEMBAU GAS, TIDAK BOLEH MENYALAKAN KOMPOR GAS ATAU API
2. LEPASKAN REGULATOR DARI TABUNG GAS, KEMUDIAN BUKA PINTU DAN JENDELA AGAR
SIRKULASI UDARA KELUAR MASUK MENJADI BAIK
3. PERIKSA KARET PADA KEPALA TABUNG, BILA PERLU GANTI BARU
4. PASANG KEMBALI REGULATOR, APABILA MASIH MEMBAU GAS MAKA GANTI YANG BARU
REGULATORNYA

19
BOILING • BOILING DESINFECTOR : ALAT UNTUK MENSTERILKAN
DESINFECTOR ALAT-ALAT KEDOKTERAN GIGI SEMI KRITIS DENGAN
SUHU 100˚CELCIUS
• PERSIAPAN; ALAT & BAHAN :
ALAT : BOILING DESINFECTOR, KORENTANG
BAHAN : AIR, HANDUK PUTIH BERSIH KERING DAN STERIL
• CARA MENSTERILKAN :
ANSANG 1. KABEL PENGHANTAR LISTRIK BOILING DISINFECTOR DI
COLOKKAN KE STOP KONTAK ARUS LISTRIK
2. BOILING DISINFECTOR DALAM KEADAAN MATI/OFF
3. MASUKKAN AIR KEDLM BD KIRA2 2-3 CM DARI PERMUKAAN
4. NYALAKAN BD DENGAN MENEKAN SWITCH/TOMBOL “ON”
5. TUNGGU AIR MENDIDIH SAMPAI 100˚C
6. ALAT2 YG SUDAH DICUCI BERSIH DIMASUKKAN KEDALAM
BD DENGAN MENGGUNAKAN KORENTANG
7. BOILING DESINFECTOR DITUTUP RAPAT
8. WAKTU/TIMER DIATUR SELAMA 15 MENIT AIR MENDIDIH
DENGAN CARA MENGATUR TEMPERATURE AUTOMATIC CONTROLER
9. SETELAH 15 MENIT LAMPU TEMPERATURE AUTOMATIC CONTROLER
AKAN MATI SENDIRI DAN AKAN KEMBALI MENUNJUKKAN ANGKA NOL
10. MATIKAN BD DENGAN MENEKAN SWITCH/TOMBOL “OFF”
11. KABEL PENGHUBUNG BD DICABUT DARI STOP KONTAK ARUS LISTRIK
12. TUTUP BD DIBUKA SEDIKIT/SELEBAR2NYA AGAR UAP AIR KELUAR
13. SETELAH UAP AIR KELUAR/TIDAK PANAS, LALU KELUARKAN ALAT-
ALAT DENGAN KORENTANG ATAU DENGAN CARA LANGSUNG MENG
ANGKAT ANGSANGNYA, KEMUDIAN ALAT-ALAT TSB DILETAKKAN DI
ATAS HANDUK BERSIH KERING DAN STERIL
14. ALAT-ALAT TSB DIKERINGKAN HINGGA BENAR-BENAR KERING
20
PERAWATAN DAN MENGATASI APABILA BOILING
BOILING DESINFECTOR MENGALAMI KERUSAKAN
DESINFECTOR • PERSIAPAN; ALAT DAN BAHAN :
ALAT : BOILING DESINFECTOR, ELECTRIC TEST PEN,
OBENG PIPIH DAN OBENG KEMBANG, TANG
BAHAN : AIR, DETRERGENT/VIM, SIKAT, SPON, DAN
HANDUK BERSIH KERING
• CARA MERAWAT BOILING DESINFECTOR :
1. ANSANG DIKELUARKAN DARI DALAM BD LALU DICUCI DENGAN AIR
BERSIH PAKAI SPON, BILA PERLU DISIKAT DENGAN MENGGUNAKAN
DETERGENT/VIM, LALU BILAS DIBAWAH AIR MENGALIR, KEMUDIAN
KERINGKAN MEMAKAI HANDUK BERSIH KERING HINGGA BENAR-
BENAR KERING
2. AIR DIDALAM BD SETELAH DINGIN DIKELUARKAN DENGAN CARA
MEMUTAR DRAIN/KRAN KEARAH KIRI, HINGGA AIRNYA HABIS,
KEMUDIAN POSISI KRAN DIKEMBALIKAN SEPERTI SEMULA
3. BD DILAP/DIKERINGKAN DENGAN HANDUK BERSIH KERING HINGGA
BENAR-BENAR BERSIH DAN KERING
4. MASUKKAN KEMBALI ANSANG KEDALAM BD KEMUDIAN TUTUP
RAPAT BD
5. KABEL PENGHUBUNG ARUS LISTRIK BD DIGULUNG, TIDAK BOLEH
PATAH-PATAH
6. LETAKKAN/SIMPAN BD KEDALAM LEMARI ALAT

21
BOILING DESINFECTOR

• CARA MENGATASI APABILA ADA KERUSAKAN RINGAN PADA BOILING


DESINFECTOR (KERUSAKAN PADA ELEMENT PEMANAS)

1. BUKA TUTUP PEMBATAS ELECTRIC DIBAGIAN BAWAH BD DENGAN MEMBUKA


MUR SKRUP DENGAN MENGGUNAKAN OBENG, PUTAR KEARAH
KIRI/BERLAWANAN ARAH JARUM JAM
2. PERIKSA BAGIAN ELEMETNYA, APABILA TERLIHAT TANDA
MENGHITAM/GOSONG MAKA ELEMENT TERSEBUT SUDAH RUSAK
3. ELEMENT DILEPAS, KEMUDIAN DIGANTI DENGAN BENTUK DAN UKURAN YANG
SAMA SEPERTI SEMULA
4. KEMUDIAN PASANG KEMBALI TUTUP PEMBATAS ELECTRIC BAGIAN BAWAH BD,
LALU KUNCI DENGAN MUR SKRUP PUTAR KEARAH KANAN/SEARAH JARUM JAM
DENGAN MENGGUNAKAN OBENG

22
PERINGATAN/WARNING
• STERILISASI BASAH DENGAN MENGGUNAKAN KOMPOR GAS :

1. APABILA MEMBAU GAS TIDAK BOLEH/DILARANG KERAS MENYALAKAN


KOMPOR/MENYALAKAN API
2. APABILA KARET PADA UJUNG TABUNG GAS ATAS REGULATOR GAS RUSAK
HARUS SEGERA GANTI DENGAN YANG BAIK

• BOILING DESINFECTOR (STERILISASI BASAH DENGAN MENGGUNAKAN ARUS


LISTRIK) :

1. PADA SAAT MEMASANG PENGHUBUNG ARUS LISTRIK BOILING DESINFECTOR KE


STOP KONTAK ARUS LISTRIK, TANGAN TIDAK BOLEH BASAH
2. PERHATIKAN ADAKAH KABEL PENGHUBUNG ARUS LISTRIK BOILING
DESINFECTOR YANG TERKELUPAS, APABILA ADA SEGERA DIBALUT DENGAN
SELOTIP LISTRIK
3. PADA SAAT MENYALAKAN BOILING DESINFECTOR, TIDAK BOLEH DALAM
KEADAAN KOSONG/TIDAK TERISI AIR
4. APABILA AKAN MENGAMBIL ALAT-ALAT DARI DALAM BOILING DESINFECTOR,
KABEL PENGHUBUNG ARUS LISTRIK BOILING DESINFECTOR HARUS DILEPAS
DARI STOP KONTAK ARUS LISTRIK
5. PADA SAAT KERJATIDAK BOLEH MEMAKAI PERHIASAN DARI LOGAM

23
TERIMA KASIH
ATAS SEGALA
PERHATIAN

24

Anda mungkin juga menyukai