Perkiraan List Alat Aspetik
Perkiraan List Alat Aspetik
Vertical : berfungsi sama baiknya dengan horizontal laminar air flow dengan udara yang
dialirkan secara vertical ke bawah kedalam area kerja. Aliran udara meninggalkan area kerja
melalui lubang-lubang yang terdapat di dasar. Kabinet model ini dapat memberikan
perlindungan lebih kepada operator.
VWS Series vertical laminar flow
cabinets
ShareFacebookTwitterGoogle+LinkedIn
Model : Vertical Laminar Flow Cabinet | Category : Laminar
Flow Cabinet | Brand : Clyde Apac
APPLICATIONS
VWS Series cabinets are designed to provide a high degree of protection for process products
and apparatus in laboratory and production facilities. Many critical applications in the
medical, pharmaceutical, scientific and electronics fields demand an ultra-clean work
environment that is free from biological and particulate contamination. Typical applications
include: Aseptic dispensingAssembly of electronics and optics componentsCell
culturingMedia pouringPreparation of medical devicesSterility testingVWS Series cabinets
are intended for work with nonhazardous materials in such applications.
Description
VWS Series cabinets are self-contained Class 3.5 vertical laminar flow work stations
designed for installation on standard laboratory benches, or on optional floor stands. Cabinets
are available with work zone width of 90cm, 120cm or 180cm. Each cabinet is factory-tested
and certified by a NATA-registered laboratory to establish compliance with the performance
requirements. Please refer to our Standardspage.
Construction
Cabinet.
The housing is constructed in electro-galvanised steel, etch-primed and finished in a special
baked enamel that has been developed for laboratory equipment.The work zone is
constructed in Grade 304 stainless steel, with the fitting of panels designed to minimise
crevices and to aid routine cleaning. A removable, washable metal screen protects the HEPA
filter from mechanical damage.
Fans.
A direct-drive fan is regulated by a speed controller to enable airflow to be maintained
through filter life. Fans and filter plenums are designed to provide ultra-quiet operation and
low vibration level.
HEPA filters.
Clyde-Apac HEPA filters are manufactured to the most exacting standards for critical
applications. Each filter is individually certified to achieve an arrestance efficiency of not less
than 99.995% to the stringent BS3928 Sodium Flame test, and to be leak-free in accordance
with AS1807.6. All testing is conducted in a NATA-registered factory laboratory and a
NATA-endorsed test label, being an extract of the test report, is affixed to each filter. The
positive-pressure filter seal is surrounded by a negative pressure zone, thus enhancing the
reliability of the filter installation.
Prefilters.
An easily-accessed, washable prefilter arrests not less than 90% of particles 5 micron and
larger, thus prolonging HEPA filter life. A warning light in the control panel signals the need
for prefilter service.
Physical Data
Overall dimensions Work zone dimensions Weight
Model
(mm) (mm) (kg)
W D H W D H
Electrical.
A low voltage touch control panel is located on the front of the cabinet. The status of all switched
functions is indicated by LEDs. An integral fluorescent lamp housing reduces heat build-up near the
operator. Glare-free lamps provide a minimum lighting intensity of 800 luxat the work floor.
Standard features
Stainless steel work zonePrefilter service indicatorPartial airflow recirculationComprehensive
operation manualLow-voltage touch controlsGlare-free fluorescent lightingQuiet, low-vibration
operationOptionsGermicidal UV lampUV shield/work zone coverIV hanging
railHourmeterManometerPower outletService taps for air, gas and vacuumFloor standDouble-sided
operationUV sterilising chamberHeated work surface for IVF applications
On-Site Testing
VWS Series cabinets are factory-tested and certified by a NATA-registered laboratory. Additional
testing and certification is recommended as follows: On site prior to use After any electrical or
mechanical maintenance After filter replacement After re-location At least annually In special
circumstances, e.g. if faulty cabinet operation is suspected
ShareFacebookTwitterGoogle+LinkedIn
Model : Horizontal Laminar Flow Cabinet |
Category : Laminar Flow Cabinet | Brand : Clyde Apac
Applications
HWS Series cabinets are designed to provide a high degree of protection for process products
and apparatus in laboratory and production facilities. Many critical applications in the
medical, pharmaceutical, scientific and electronics fields demand an ultra-clean work
environment which is free from biological and particulate contamination. Typical
applications include: Aseptic dispensingAssembly of electronics and optics componentsCell
culturingMedia pouringPreparation of medical devices/equipmentSterility testing HWS
Series cabinets are intended for work with non-hazardous materials in such applications.
Australian and International Standards
Please refer to our Standards page.
Description
HWS Series cabinets are self-contained Class 3.5 horizontal laminar flow work stations
designed for installation on standard laboratory benches, or on optional floor stands. Cabinets
are produced with work zone width of 90cm, 120cm or 180cm, with the option of 60cm or
75cm work zone height. Each cabinet is factory-tested and certified by a NATA-registered
laboratory to establish compliance with the performance requirements of AS1386, Part 5.
Operation
Horizontal laminar flow in the work zone creates a biologically-clean, particle-free work
environment. A direct-drive fan draws in ambient air through a prefilter on the top of the
cabinet and supplies it to the work zone through a HEPA filter. The average air velocity in
the work zone is maintained between 0.45 and 0.5 m/s, with all velocity readings within 20%
of their average. Air cleanliness within the work zone is better than Class 3.5 (Class 100). To
enhance work zone air cleanliness, it is recommended that cabinets are installed in
cleanrooms which provide a secondary barrier.
ConstructionCabinet.
Constructed in electro-galvanised steel, etch primed and
finished in a special baked enamel that has been developed
for laboratory equipment. The work zone is constructed in
Grade 304 stainless steel. The stainless steel work surface
incorporates a lip to prevent liquid spills from contacting the
HEPA filter. A removable, washable metal screen protects
the HEPA filter form mechanical damage.
Fans.
A direct-drive fan is regulated by a speed controller to enable airflow to be maintained
through filter life. Fans and filter plenums are designed to provide ultra-quiet operation and
low vibration level.
HEPA filters.
Clyde-Apac HEPA filters, are manufactured to the most exacting standards for critical
applications. Each filter is individually certified to achieve an arrestance efficiency of not
less than 99.995% to the stringent BS3928 Sodium Flame test. All testing is conducted in a
NATA-registered factory laboratory and a NATA-endorsed test label, being an extract of the
test report, is affixed to each filter. Prefilters.
An easily-accessed, washable prefilter arrests not less than 90% of particles 5 micron and
larger, thus prolonging HEPA filter life. A warning light in the control panel signals the need
for Prefilter service. Physical data
W D H W D H
Electrical.
A low voltage touch control panel is located on the front of the cabinet. The status of all switched
functions is indicated by LEDS. Glare-free lamps provide a minimum lighting intensity of 800 lux at the
work floor.
Laminar Air Flow Services, a NATA-registered laboratory and a division of Clyde-Apac, provides
comprehensive on-site maintenance, testing and certification services for safety cabinets, laminar flow
work stations, cleanrooms and HEPA filter installations. This service is available from fully-equipped,
Due to ongoing research & development, Clyde-Apac reserves the right to modify the product &
specifications without notice.
24 Masker N 95 Rp 16.400