PRAKTIKUM
MESIN KONVERSI ENERGI 2
Oleh:
1. BHAKTI GUMIRA ADI DHARMA 2112182008
2. RESA WARDANA 2112182009
3. ANDAR LETARE LUMBAN GAOL 2112182010
4. MUHAMMAD IQBAL MAULANA 2112182014
Pompa Seri
Debit Daya 1 p5 Daya 2
No p1 (kPa) p2 (kPa) p3 (kPa) p4 (kPa)
(L/mnt) (kW) (kPa) (W)
1 26 154 9.3 26 -8.2 8 17 159
2 24 156 23.4 66 -7.5 25 57 162
3 22 159 41 111 -6.8 46 104 166
4 20 162 61.8 142 6.9 61 136 169
5 18 165 84.6 194 -5.9 86 189 173
6 16 168 97.2 222 -5.6 99 217 174
7 14 173 0 291 -5.1 133 289 182
Pompa Paralel
Debit Daya 1 p5 Daya 2
No p1 (kPa) p2 (kPa) p3 (kPa) p4 (kPa)
(L/mnt) (W) (kPa) (W)
1 44 155 -6.3 41 -7.2 43 19 164
2 42 155 -5.8 48 -7 50 27 164
3 40 157 -6.2 57 -6.7 59 38 166
4 38 158 -6.1 72 -6.3 73 35 169
5 36 159 -5.1 81 -6 83 66 170
6 34 160 -6.7 95 -5.8 97 80 172
7 32 161 -5.5 104 -5.5 106 92 173
8 31 163 -6 114 -5.4 115 101 176
9 30 162 -5.9 117 -5.5 121 107 176
10 29 162 -5.3 126 -5.4 128 117 178
11 28 163 -5.2 136 -5.2 136 165 179
12 27 163 -4.8 139 -5.1 140 129 180
13 26 164 -5.9 145 -4.9 147 137 181
14 25 166 -5.3 153 -4.9 155 144 183
B. Tabel Perhitungan
Head Loss Total Pompa
HLmayor (M)
H1 H1 Tota
H8 H9 H10 1 2H13 l
0.3 0.3 3.89
3 1 5
0.3 0.3 0.81 0.2 0.20
3 1 5 8 5 4.38
0.3 0.3 0.81 0.2 0.2
3 1 5 8 3 5.22
Debit
N HLmayo HLMino Hgedeti Hstatik Hstatik
(L/mnt
o r (M) r (M) k (M) P1 (M) P2(M)
)
1 24 3.895 0.4628 0.815 4.17 0
2 22 3.895 0.4628 0.815 5.68 0
3 20 3.895 0.4628 0.815 7.84 0
4 18 3.895 0.4628 0.815 11.01 0
5 16 3.895 0.4628 0.815 13.48 0
6 14 3.895 0.4628 0.815 16.13 0
7 12 3.895 0.4628 0.815 19.39 0
Debit
N HLmayo HLMino Hgedeti Hstatik Hstatik
(L/mnt
o r (M) r (M) k (M) P1 (M) P2 (M)
)
1 26 4.38 0.666 0.815 1.67 1.62
2 24 4.38 0.666 0.815 4.26 3.25
3 22 4.38 0.666 0.815 7 5.28
4 20 4.38 0.666 0.815 8.02 5.41
5 18 4.38 0.666 0.815 10.94 9.19
6 16 4.38 0.666 0.815 12.48 10.46
7 14 4.38 0.666 0.815 29.1 13.81
H Total
Debit Diameter Luas Pipa Hdinamik
No V2 (m/s) Pompa
(L/mnt) Pipa (m) (m) (M)
(M)
1 26 0.0254 0.000506 0.855628 0.042781 9.193781
2 24 0.0254 0.000506 0.78981 0.039491 13.41049
3 22 0.0254 0.000506 0.723993 0.0362 18.1772
4 20 0.0254 0.000506 0.658175 0.032909 19.32391
5 18 0.0254 0.000506 0.592358 0.029618 26.02062
6 16 0.0254 0.000506 0.52654 0.026327 28.82733
7 14 0.0254 0.000506 0.460723 0.023036 48.79404
Debit
N HLmayo HLMino Hgedeti Hstatik Hstatik
(L/mnt
o r (M) r (M) k (M) P1 (M) P2 (M)
)
1 44 5.22 0.8184 1.63 4.73 5.02
2 42 5.22 0.8184 1.63 5.38 5.7
3 40 5.22 0.8184 1.63 6.32 6.57
4 38 5.22 0.8184 1.63 7.81 7.93
5 36 5.22 0.8184 1.63 8.61 8.9
6 34 5.22 0.8184 1.63 10.17 10.28
7 32 5.22 0.8184 1.63 10.95 11.15
8 31 5.22 0.8184 1.63 12 12.04
9 30 5.22 0.8184 1.63 12.29 12.65
10 29 5.22 0.8184 1.63 13.13 13.34
11 28 5.22 0.8184 1.63 14.12 14.12
12 27 5.22 0.8184 1.63 14.38 14.51
13 26 5.22 0.8184 1.63 15.09 15.19
14 25 5.22 0.8184 1.63 15.83 15.99
c.
d.
e.
D. Analisa Data
E. Kesimpulan
Jika sistem mempunyai kurva karakteristik R2 maka laju aliran akan sama
untuk susunan seri maupun parallel. Namun, jika karakteristik sistem adalah R 1
dan R3 maka akan diperlukan pompa dalam susunan seri atau paralel. Susunan
paralel pada umumnya diperlukan untuk laju aliran besar, dan susunan seri untuk
head yang tinggi pada titik operasi.
Pengaturan kapasitas adalah sebagai berikut:
Pengaturan katup yaitu menggunakan katup pengatur yang dipasang di pipa keluar
pompa. Aliran diatur dengan jalan menghambat aliran dengan merubah-rubah
pembukaan katup maka kerugian head makin besar.
F. Daftar Pustaka
G. Lampiran Foto-foto