TIRTAYASA UNIVERSITY
C i v i l E n g i n e e r i n g
STRUKTUR BETON II

KOLOM
(COLUMN)
by
Baehaki, ST.M.,Eng

STRUKTUR BETON II
Kuliah - 08 1
Program S1 Teknik Spil

TIRTAYASA UNIVERSITY
C i v i l E n g i n e e r i n g
STRUKTUR BETON II

Kuliah_08
(PENDAHULUAN)
by
Baehaki, ST.M.,Eng

STRUKTUR BETON II
Kuliah - 08 2
Program S1 Teknik Spil

1
10/14/2015

TIRTAYASA UNIVERSITY
C i v i l E n g i n e e r i n g
STRUKTUR BETON II

• A column is vertical structural member


supporting axial compressive loads, with or with
out moments. Column support vertical loads
from the floors and roof and transmit these
loads to the foundations. (James G.
MacGregor & James K. Wight)

STRUKTUR BETON II
Kuliah - 08 3
Program S1 Teknik Spil

TIRTAYASA UNIVERSITY
C i v i l E n g i n e e r i n g
KELEBIHAN/KEKURANGAN BETON

Kelebihan Beton Kekurangan Beton

Beton kuat terhadap Beton lemah terhadap


beban Tekan (compression) beban Tarik (Tension)

Sumber : Dr. Rabin Tuladhar


STRUKTUR BETON II
Kuliah - 08 4
Program S1 Teknik Spil

2
10/14/2015

TIRTAYASA UNIVERSITY
C i v i l E n g i n e e r i n g
FUNGSI KOLOM

1. Kolom dominan memikul beban tekan


2. Pada bangunan gedung, kolom berfungsi
meneruskan beban-beban dari lantai atas ke lantai
dibawahnya dan ke tanah melalui pondasi
3. Selain gaya aksial, kolom juga menahan momen
lentur dan gaya lintang

STRUKTUR BETON II
Kuliah - 08 5
Program S1 Teknik Spil

TIRTAYASA UNIVERSITY
C i v i l E n g i n e e r i n g
FUNGSI KOLOM

Satu Arah (Uniaxial)

Momen Lentur

Dua Arah (Biaxial)

STRUKTUR BETON II
Kuliah - 08 6
Program S1 Teknik Spil

3
10/14/2015

TIRTAYASA UNIVERSITY
C i v i l E n g i n e e r i n g
TIPE KOLOM

Sifat kolom sangat dipengaruhi oleh penulangan pengikat


lateral. Berdasarkan jenis penulangan tersebut, kolom
dibedakan menjadi :
1. Kolom ikat (Tied Column) dengan tulangan pengikat
sengkang biasa. Biasanya kolom ini berpenampang
persegi atau bujur sangkar
2. Kolom dengan penulangan spiral (Spiral Column),
biasanya untuk penampang lingkaran
3. Kolom komposit yang menggunakan baja profil atau pipa
yang tanpa atau dengan tulangan memanjang dan
melintang

STRUKTUR BETON II
Kuliah - 08 7
Program S1 Teknik Spil

TIRTAYASA UNIVERSITY
C i v i l E n g i n e e r i n g
TIPE KOLOM
Tipe Kolom Berdasarkan Tulangan Lateral:

Dalam praktek kolom ikat paling umum digunakan, sedangkan kolom


dengan tulangan spiral dapat berfungsi juga untuk menaikan daktilitas
kolom. Daktilitas yang besar diperlukan khususnya untuk daerah gempa.
Kolom spiral mempunyai daktilitas yang besar disebabkan oleh pengaruh
pengekangan beton (confined concrete) oleh tulangan spiral. Pada kolom
berpenampang persegi, pengekangan bisa dilakukan dengan cara
pemasangan begel dan tulangan memanjang dengan jarak rapat.
STRUKTUR BETON II
Kuliah - 08 8
Program S1 Teknik Spil

4
10/14/2015

TIRTAYASA UNIVERSITY
C i v i l E n g i n e e r i n g
TIPE KOLOM
Tipe Kolom Berdasarkan letak beban:

Kolom yang dibebani aksial konsentrik praktis tidak menahan momen


lentur. Dalam praktek, kolom yang dibebani secara konsentrik hampir
tidak ada. Eksentris dapat disebabkan oleh:
• Ketidaksempurnaan pembuatan kolom
• Perpindahan relatif ujung-ujung kolom akibat beban

Eksentrisitas (e) mengakibatkan momen lentur, yang besarnya sama


dengan gaya aksial (P) dikalikan dengan eksentrisitas (e) yaitu, M=P.e.

(Untuk lebih jelasnya perhatikan gambar pada slide berikutnya)

STRUKTUR BETON II
Kuliah - 08 9
Program S1 Teknik Spil

TIRTAYASA UNIVERSITY
C i v i l E n g i n e e r i n g
TIPE KOLOM
Tipe Kolom Berdasarkan letak beban:

P P ey P P P
Mx ey
Mx My
y y y y y
ex
x x x x x

Or Or

Aksial Aksial & Aksial &


Konsentris momen uniaxial momen biaxial

STRUKTUR BETON II
Kuliah - 08 10
Program S1 Teknik Spil

5
10/14/2015

TIRTAYASA UNIVERSITY
C i v i l E n g i n e e r i n g
TIPE KOLOM
Tipe Kolom Berdasarkan Nilai eksentrisitas “e” :

• Nilai Eksentrisitas e Kecil


• Nilai Eksentisitas e Sedang
• Nilai Eksentrisitas e Besar
• Nilai Eksentrisitas e Sangat Besar

STRUKTUR BETON II
Kuliah - 08 11
Program S1 Teknik Spil

TIRTAYASA UNIVERSITY
C i v i l E n g i n e e r i n g
TIPE KOLOM
Tipe Kolom Berdasarkan Nilai eksentrisitas “e” :

Eksentrisitas Momen Teg. Tarik Teg. Tekan Aksial Failure


Kecil kecil kecil Besar P0 Tekan
Sedang sedang sama besar sama besar P  0 Seimbang
Besar Besar Besar Kecil P 0 Tarik
Sangat Besar Sangat Besar Sangat Besar Kecil P=0 Lentur

Sumber : Ali Asroni


STRUKTUR BETON II
Kuliah - 08 12
Program S1 Teknik Spil

6
10/14/2015

TIRTAYASA UNIVERSITY
C i v i l E n g i n e e r i n g
Diagram Interaksi (P-M-M)

Sumber : Ali Asroni


STRUKTUR BETON II
Kuliah - 08 13
Program S1 Teknik Spil

TIRTAYASA UNIVERSITY
C i v i l E n g i n e e r i n g
TIPE KOLOM
Tipe Kolom Berdasarkan panjang kolom :

• Kolom panjang  Kolom panjang sering juga


disebut dengan kolom langsing atau kurus,
kegagalan yang terjadi adalah akibat
kehilangan stabilitas lateral karena Tekuk.
• Kolom Pendek  Kolom pendek sering juga
disebut dengan kolom gemuk, kegagalan
kolom disebabkan oleh kegagalan materialnya
(lelehnya baja tulangan atau hancurnya beton)

STRUKTUR BETON II
Kuliah - 08 14
Program S1 Teknik Spil

7
10/14/2015

TIRTAYASA UNIVERSITY
C i v i l E n g i n e e r i n g
Asumsi Perancangan
1. Distribusi regangan di sepanjang tebal kolom dianggap berupa garis
lurus (linier). Pasal 12.2.2 SNI 2847-2002
2. Tidak terjadi slip antara beton dan tulangan Pasal 12.2.2 sni 2847-2002
3. Regangan tekan maksimal beton dibatasi pada kondisi ultimit = 0,003.
Pasal 12.2.3 SNI 2847-2002
4. Kekuatan tarik beton diabaikan. Pasal 12.2.5 SNI 2847-2002
5. Tegangan baja tulangan tarik maupun tekan yang belum mencapai
leleh dihitung sebesar modulus elastisitas baja tulangan (Es) dikalikan
dengan regangannya. Pasal 12.2.4 SNI 2847-2002
6. Hubungan antara distribusi tegangan tekan beton dan regangan beton
dapat diasumsikan persegi, trapseium, parabola atau bentuk lainnya.
Pasal 12.2.6 SNI 2847-2002
7. Jika diasumsikan tengan beton berbentuk persegi ekivalen, maka nilai
teg beton sebesar 0,85 fc yang terdistribusi merata pd daerah tekan
ekivalen. Pasal 12.2.7.1 SNI 2847-2002

STRUKTUR BETON II
Kuliah - 08 15
Program S1 Teknik Spil

TIRTAYASA UNIVERSITY
C i v i l E n g i n e e r i n g
Distribusi Tegangan

Sumber : Ali Asroni


STRUKTUR BETON II
Kuliah - 08 16
Program S1 Teknik Spil

8
10/14/2015

TIRTAYASA UNIVERSITY
C i v i l E n g i n e e r i n g
SELANJUTNYA…..

KOLOM UNIAKSIAL

PELAJARI
MATERI TERKAIT
TOPIK
PEMBAHASAN
MINGGU DEPAN

STRUKTUR BETON II
Kuliah - 08 17
Program S1 Teknik Spil