PEMELIHARAAN
Client:
PT. ABADI PRIMA INTI KARYA
Proyek:
RUSUN UGM
Gang Kinanthi Kel. Catur Tunggal Kec. Depok Sleman – D.I. Yogyakarta
Halaman
KATA PENGANTAR 1
BAB I PENDAHULUAN 2
BAB II PROSES 3
2.1 Separation Tank 4
2.2 Anaerob Tank 4
2.3 Aeration Tank 4
2.4 Sedimentation Tank 5
2.5 Effluent Tank 5
2.6 Blower Room 5
BAB III DASAR PERENCANAAN 6
3.1 Inlet Water Quality 6
3.2Outlet Water Quality 6
BAB IV SPESIFIKASI PERALATAN 7
4.1 Bioreactor Tank STP System 7
4.2 Honey Comb 7
4.3 Bioball 7
4.4 Air Blower 7
4.5 Effluent Pump 7
4.6 Air Diffuser 8
4.7 Control Panel 8
4.8 Piping Installation & Valve 8
4.9 Cable & Accessories 8
BAB V PENGOPERASIAN 9
5.1 Umum 9
5.2 Standar Operasional Prosedur (SOP) 10
BAB VI PEMELIHARAAN 11
6.1 Umum 11
6.2 Pemeriksaan dan Pemeliharaan 13
6.3 Inspeksi Sebelum Penggunaan 15
6.4Inspeksi dan Pemeliharaan Berkala 16
BAB VII PENYELESAIAN MASALAH UMUM DI STP 17
BAB VIII STANDAR OPRASIONAL PROSEDUR TANGGAP DARURAT 18
BAB IX PENUTUP 19
LAMPIRAN 20
1
PT. RECKAT COMPOSITES DELMIMA
KATA PENGANTAR
Terima kasih atas kepercayaan yang telah diberikan PT. Abadi Prima Inti Karya
kepada PT. Reckat Composites Delmim untuk membangun Instalasi Pengolahan Air
Limbah Domestik (IPAL) dengan kapasitas 20 m / hari di Rusun UGM, Yogyakarta.
Buku ini disusun untuk dijadikan petunjuk dan dasar kerja operator dalam
mengoprasikan dan memelihara IPAL/STP yang ada di Rusun UGM, Yogyakarta
tersebut.
Mudah-mudahan bukuini dapat membantu para operator Sewage Treatment Plant (STP)
agar dapat lebih memahami sistem kerja STP sehingga hasil air olahan akan selalu dapat
memenuhi bakumutu lingkungan yang ada.
2
PT. RECKAT COMPOSITES DELMIMA
BAB I
PENDAHULUAN
Sistem Pengolahan Air Limbah (Sewage Treatment Plant/STP) ini khusus didesain untuk
mengolah air limbah yang dibuang oleh Rusun UGM, Yogyakarta ini didesain
berdasarkan kapasitas air limbah buangan sebesar 20 m / hari.
`
Fungsi dariunit STP ini adalah melakukan proses pengolahan untuk mengurangi
parameter-parameter pencemar dalam air limbah sehingga air hasil olahannya aman
untuk dibuang ke saluran umum (drainase).
Metode pengolahan air limbah pada sistem ini adalah pengolahan secara biologis dengan
menggunakan bakteri yang ditumbuhkan pada media Honeycomb (pada kondisi an-
aerob)dan Bioball (pada kondisi aerob) dimana bakteri-bakteri yang terkandung di dalam
air limbah dapat berkembang biak dengan baik pada media, sesuai kondisi lingkungannya
dan melakukan proses dekomposisi/penguraian zat-zat pencemar secara optimal.
Unit STP ini didesain dengan System BioReckat dan beroperasi secara kontinyu / terus
menerus. Air Limbah Domestik ini, akan mengalami proses pengolahan hingga
memenuhi peraturanyang dipersyaratkan dan aman untuk dibuang ke dalam saluran
drainase perkotaan.
Buku Petunjuk ini digunakan sebagai buku panduan bagi operator untuk mengoperasikan
dan memelihara IPAL agar sesuai dengan prosedur sehingga sistem dapat bekerja secara
optimal.
3
PT. RECKAT COMPOSITES DELMIMA
BAB II
PROSES
Sistem ini terdiri dari Separation Tank, Anaerob Tank, Aeration Tank, Sedimentation
Tank, Effluent Tank dan Blower Room lengkap dengan berbagai aksesoris, dengan uraian
penjelasannya sebagai berikut:
4
PT. RECKAT COMPOSITES DELMIMA
Blower dan Diffuser, yang berfungsi menciptakan gelembung-gelembung udara
halus (fine bubble) agar proses penyerapan oksigen oleh mikroorganisme dapat
lebih optimal.
5
PT. RECKAT COMPOSITES DELMIMA
BAB III
DASAR PERENCANAAN
Amoniac : 50 mg/L
BOD : 30 mg/L
Amoniac : 10 mg/L
6
PT. RECKAT COMPOSITES DELMIMA
BAB IV
PERALATAN
4.2 HONEYCOMB
- Model : Wide Contact
- Material : PVC
- Quantity : 1 Unit (3.06 m3)
4.3 BIOBALL
- Model : Wide Contact
- Material : HDPE
- Quantity : 1 Lot (80000Pcs)
7
PT. RECKAT COMPOSITES DELMIMA
4.7 PANEL CONTROL
- Brand :Indoor
- Type : Push Bottom
- Display : Indicating Lamp
- Component : Merlin Gerlin, Telemecanique, Omron, etc
- Quantity : 2 Unit
8
PT. RECKAT COMPOSITES DELMIMA
BAB V
PENGOPERASIAN
5.1 Umum
No. Peralatan Sistem Operasi Keterangan
Effluent Tank
- Chlorination Pipe - Sebagai tempat untuk memasukan Tablet - 1 Unit
Chlorine ke dalam tangki dengan cara
membuka penutup pipa secara manual.
Blower Room
- Air Blower - Bekerja secara kontinyu 24 jam. Sistem - 4 Unit
distribusi udara diatur secara manual dengan (2 run + 2 stand
6. menggunakan valve ke tiap tank by)
- Bekerja secara bergantian secara auto
berdasarkan timer.
9
PT. RECKAT COMPOSITES DELMIMA
5.2 Standar Operasional Prosedur (SOP) Pengoperasian
Unit pengolahan limbah ini dirancang dengan sistim pengoperasian otomatis. Dan
pengoperasiannya dikendalikan berdasarkan level air di dalam setiap bak-bak
penampungan. Meskipun sistim ini didesain secara otomatis, namun untuk
mengantisipasi terjadinya trouble, dalam pengoperasian dapat dilakukan secara manual,
agar sistim dapat terus berjalan dengan baik.
2. Pengoperasian Sistem :
2.1.Pengoperasian Secara Otomatis
Putar semua Selector Switch kearah “AUTO”.
Untuk mematikan pengoperasian putar Selector Switch kearah “OFF”.
Catatan :
10
PT. RECKAT COMPOSITES DELMIMA
BAB VI
PEMELIHARAAN
6.1 Umum
3. Periode Pemeriksaan
Pemeriksaan pertama dilakukan sebelum pengoperasian dimulai, pada saat test
dan commissioning.
Pemeriksaan selanjutnya sebaiknya dilakukan setiap bulan sekali.
Periksa tablet chlorine dalam pipa klorinasi dan masukkan tablet chlorine jika
diperlukan setiap 1 minggu sekali.
Periksa waktu penyedotan sludge, lakukan penyedotan jika memang diperlukan,
diperkirakan setiap 2 tahun sekali.
11
PT. RECKAT COMPOSITES DELMIMA
12
PT. RECKAT COMPOSITES DELMIMA
6.2 Pemeriksaan Dan Pemeliharaan
A Grease Trap Pembersihan sampah / 1. Periksa screen dari kotoran yang tertahan
(Supplied by kotoran / lemak / minyak (sisa makanan, dll) angkat dan buang
Other) kotoran, sebaiknya dilakukan setiap hari
2. pemeriksaan lemak, angkat dan buang,
sebaiknya dilakukan 1 minggu sekali atau
lebih sering, terutama untuk mencegah bau
yang tidak sedap
13
PT. RECKAT COMPOSITES DELMIMA
F Effluent Tank Pipa Klorinasi Pastikan terdapat Tablet Chlorine pada pipa
klorinasi. Lakukan pengecekan tablet klorin
setiap 1 minggu sekali.
Pipa Outlet
1. Pastikan tangki tidak bocor
2. Periksa pipa outlet tidak bocor dan tidak
ada sumbatan
Effluent Pump
1. Pastikan pompa berjalan normal
2. Periksa jangan sampai ada sumbatan pada
pompa
14
PT. RECKAT COMPOSITES DELMIMA
15
PT. RECKAT COMPOSITES DELMIMA
6.4 Inspeksi Dan Pemeliharaan Berkala
Periode
Jenis
Titik Inspeksi
Pemeriksaan 1 1 3 6 12 2
mgg bln bln bln bln thn
16
PT. RECKAT COMPOSITES DELMIMA
BAB VII
Tidak ada aliran udara 1. Blower tidak terhubung 1. Cek koneksi dan voltase
atau aliran udara di dengan power supply
BakAerasi kecil 2. Kerusakan elektrik 2. Cek kondisi elektrik dengan
alat tes
3. Filter blok 3. Bersihkan filter udara
4. Pemipaan bocor 4. Sambungan dan perbaiki
kebocoran
5. Valve Tertutup 5. Buka valve
6. Valve Rusak 6. Buka valve lama, ganti dengan
valve baru
Air lift pump tidak 1. Valve tertutup 1. Buka valve
mengalir dari sedimentasi 2. Valve rusak 2. Buka valve lama, ganti dengan
ke bak aerasi valve yang baru
3. Tidak ada power supply 3. Cek koneksi dan voltase
4. Pemipaan bocor 4. Sambung dan perbaiki
kebocoran
5. Volume lumpur berlebih 5. Kuras lumpur di bak
dan terjadi sumbatan sedimentasi dan bersihkan
pipa air lift
Pompa tidak berjalan 1. Tidak ada power supply 1. Cek koneksi dan voltase
pertama kali 2. Otomatis tidak berfungsi 2. Cek water level control
Aliran air kecil atau tidak 1. Saringan pompa tersumbat 1. Bersihkan saringan pompa
mengalir 2. Pemipaan bocor 2. Sambung dan perbaiki
kebocoran
Pompa tidak bergantian 1. Switch di posisi manual 1. Pindahkan switch di control
secara otomatis atau off panel keposisi auto
2. Komponen timer rusak 2. Perbaiki dan ganti komponen
timer auto
Air outlet timbul bau 1. Kekurangan bakteri 1. Tambahkan bakteri starter
BOD tidak tercapai pengurai 2. Isikan tablet klorin pada
2. Tablet klorin kosong tabungklorin
3. Cek kondisi blower dan
3. Aerasi tidak berfungsi pemipaan difusser
4. Cek volume lumpur, kuras
4. Volume lumpur berlebih dengan mobil pengambil
lumpur yang memiliki izin
limbah B3
5. Belum dilakukan cek 5. Lakukan pengecekan
laboratorium laboratorium untuk
mengetahui hasil pengolahan
limbah
6. Over Capacity 6. Ukur dan pastikan debit
limbah tidak melebihi
kapasitas STP
17
PT. RECKAT COMPOSITES DELMIMA
BAB VIII
Sistem Operasional Prosedur (SOP) Tanggap Darurat
2. Apabila aliran listrik utama di IPAL pada melebihi dari 2 (dua) jam. Hidupkan genset
Gedung, hal ini untuk mencegah bakteri Aerob kolaps/mati karena tidak ada supply
oksigen. Apabila dalam 24 jam listrik masih dalam kondisi padam penambahan bakteri
starter Aerob harus dilakukan.
3. Apabila terjadi kebocoran/keretakan bak atau kolam IPAL (akibat gempa bumi tau hal
lainnya). Proses IPAL dihentikan sementara. Selanjutnya melakukan pemeriksaan dan
perbaikan setelah kondisi dinilai aman.
4. Apabila terjadi kecelakaan tersebut ke kolam/bak IPAL maka diberi pertolongan pertama di
tempat kejadian. Selanjutnya segera dibawa ke klinik/rumah sakit terdekat untuk
mendapatkan pertolongan medis lanjutan.
5. Apabila terjadi permasalahan pada equipment yang menyebabkan banjir pada IPAL dan
tercampurnya seluruh air limbah pada sistem. Hal ini menyebabka matinya bakteri, baik
aerob atau anaerob. Proses IPAL harus dihentikan dan dilakukan pengurasan pada setiap
bak STP serta penambahan bakteri starter ketika limbah sudah masuk STP.
6. Khusus Rumah Sakit apabila IPAL memiliki sumber air limbah yang berasal dari
Laboratorium dan mengandung bahan kimia atau reagen harus melalui bak Neutralizing
sebelum masuk IPAL. Karena apabila senyawa kimia masuk kedalam STP maka bakteri
Anaerob dan Aerob mati karna terpapar senyawa/bahan kimia laboratorium, selain itu
minimalisir tersebarnya senyawa kimia ke badan air. Apabila senyawa kimia tersebut
masuk ke dalam IPAL maka harus dilakukan pengursan.
18
PT. RECKAT COMPOSITES DELMIMA
BAB IX
PENUTUP
Demikian buku Operational Manual ini dibuat, semoga buku operation manual ini dapat
berguna dalam pelaksanaan pengoprasian dan pemeliharaan peralatan Sewage Treatment
Plant (STP) yang terpasang di Rusun UGM, Yogyakarta.
19
PT. RECKAT COMPOSITES DELMIMA
LAMPIRAN
20
%
+66XEPHUVLEOH3RUWDEOH'HZDWHULQJ3XPS
+6 = 6+6(6
+6 = 6+6 = 6
23(5$7,210$18$/
,1752'8&7,21
7KDQN\RXIRUVHOHFWLQJWKH7VXUXPL+66XEPHUVLEOH9RUWH[3XPSIRU\RXUDSSOLFDWLRQ
7KLVHTXLSPHQWVKRXOGQRWEHXVHGIRUDSSOLFDWLRQVRWKHUWKDQWKRVHOLVWHGLQWKLVPDQXDO
)DLOXUHWRREVHUYHWKLVSUHFDXWLRQPD\OHDGWRDPDOIXQFWLRQRUDQDFFLGHQW,QWKHHYHQWRI
DPDOIXQFWLRQRUDQDFFLGHQWWKHPDQXIDFWXUHUZLOOQRWDVVXPHDQ\OLDELOLW\$IWHUUHDGLQJ
WKLV2SHUDWLRQ0DQXDONHHSLWLQDORFDWLRQWKDWLVHDVLO\DFFHVVLEOHVRWKDWLWFDQEHUH
IHUUHGWRZKHQHYHULQIRUPDWLRQLVQHHGHGZKLOHRSHUDWLQJWKHHTXLSPHQW
&217(176
%(685(725($')256$)(7<
3$571$0(6
35,257223(5$7,21
,167$//$7,21
(/(&75,&$/:,5,1*
23(5$7,21
0$,17(1$1&($1',163(&7,21
',6$66(0%/<$1'5($66(0%/<352&('85(
7528%/(6+227,1*
768580,0$18)$&785,1*&2/7'
%(685(725($')25<2856$)(7<
Be sure to thoroughly read and understand the SAFETY PRECAUTIONS given in this section before using
the equipment in order to operate the equipment correctly.
The precautionary measures described in this section are intended to prevent danger or damage to you or
to others. The contents of this manual that could possibly be performed improperly are classified into two
categories: WARNING, and CAUTION. The categories indicate the extent of possible damage
or the urgency of the precaution. Note however, that what is included under CAUTION may at times
lead to a more serious problem. In either case, the categories pertain to safety-related items, and as such,
must be observed carefully.
WARNING : Operating the equipment improperly by failing to observe this precaution may possibly
lead to death or injury to humans.
CAUTION : Operating the equipment improperly by failing to observe this precaution may possibly
cause injury to humans and other physical damage.
● NOTE : Gives information that does not fall in the WARNING or CAUTION categories.
● Explanation of Symbols:
:The mark indicates a WARNING or CAUTION item. The symbol inside the mark describes the
precaution in more detail ("electrical shock", in the case of the example on the left).
:The mark indicates a prohibited action. The symbol inside the mark, or a notation in the vicinity of
the mark describes the precaution in more detail ("disassembly prohibited", in the case of the
example on the left).
:The mark indicates an action that must be taken, or instructs how to perform a task. The symbol
inside the mark describes the precaution in more detail ("provide ground work", in the case of the
example on the left).
35(&$87,216727+(352'8&763(&,),&$7,216
CAUTION
Do not operate the product under any conditions other than those for which it is speci-
Frequency
fied. Failure to observe the precaution can lead to electrical leakage, electrical Voltage
shock, fire, water overflow or other problems.
35(&$87,216'85,1*75$163257$1',167$//$7,21
WARNING
Use an appropriate lifting equip- Install the product properly in
ment to lift the unit. Improper accordance with this instruction
lifting may result in the fall of manual. Improper installation
the product which could cause may result in electrical leakage,
damage of the product or electrical shock, fire, water
human injury. leakage, or injury.
Electrical wiring should be Provide a secure grounding
performed in accordance with all dedicated for the product. Never
applicable regulations in your fail to provide an earth leakage
country. Imperfect wiring or circuit breaker and a thermal
neglecting the installation of overload relay in your starter or
proper equipment will cause control panel (Both available on
electrical leakage or fire. the market). If an electrical
leakage occurs by due to a
product failure, it may cause
electrical shock.
Use a power outlet that has a sufficient rating and has been exclusively Power
provided for the pump. If the power outlet is shared with other equipment, Supply
it can lead to an abnormal heat of the outlet and can cause fire as a Capacity
result.
CAUTION
Be sure to provide a ground wire Prevent a metallic object or dust
securely. Do not connect the from sticking to the power plug.
ground wire to a gas pipe, Adhesion of foreign object to the
water pipe, lightening rod, or plug could cause electrical
telephone ground wire. Improper shock, short-circuit, or fire.
grounding could cause electri-
cal shock.
Do not scratch, fold, twist, make Do not use the cabtyre cable, power
alterations, or bundle the cable, or plug, or power outlet if it is damaged
use it as a lifting device. The cable or it is not closely fitted. Connect
may be damaged, which may every conductor of the cabtyre cable
cause electrical leakage, short- securely to the terminals. Failure to
circuit, electrical shock, or fire. observe this can lead to electrical
shock, short-circuit, or fire.
Install the discharge pipe When the product will be carried by
securely so that no water leakage hand, decide the number of persons
may occur. In addition, It is considering the mass of the product.
suggested to provide a stand-by When lifting up the product, do
pump in case of flooding. Failure not attempt to do it by simply
to do so may result in damage bowing from the waist. Use the
to nearby walls, floors, and knees, too, to protect your back.
other equipment.
This pump is neither dust-proof nor Allow the pump to suck as few
explosion-proof. Do not use it at a foreign object as possible. If there
dusty place or at a place where is a risk that the pump could be
toxic, corrosive or explosive gas is buried under the sediment, place it
present. Use in such places on a solid base like concrete
could cause fire or explosion. block. Failure to do so may
result in breakdown of the
If a hose is used for the discharge pump and could cause electri-
line, take a measure to prevent the cal leakage or short circuit.
hose from shaking. If the hose
shakes, you may be wet or
injured.
35(&$87,216'85,1*7(6723(5$7,21$1'23(5$7,21
WARNING
Never try to operate the pump if When changing power connection is
somebody is present in the pump needed to correct the direction of OFF
sump. If an electrical leakage rotation, be sure to turn off the
occurs, it can cause electrical power supply (earth leakage circuit
shock. breaker, etc.), and perform the work
after making sure that the impeller
Never start the pump while it is has stopped completely. Failure to
suspended, as the unit may jerk do so may lead to electrical
and could lead to injury. shock, short-circuit, or injury. STOP
CAUTION
Do not operate the product under Do not touch the product with bare
any voltage other than described hands during or immediate after
on the nameplate with the voltage the operation, as the product may
variation limit within ±10%. If it is become very hot during operation.
operated with a generator, it is Failure to observe this caution
strongly suggested not to operate Rated
Voltage may lead to be burned.
other equipment with the same
generator. Failure to observe this caution
may cause malfunction and breakdown
of the product, which may lead to
electrical leakage or electrical shock.
Do not use the pump for oil, sea Do not run the product dry or
water, or strong acid. Use for operate it with its gate valve
these liquid may result in the closed, as doing so will damage
damage of the pump. For oil, the product, which may lead to
sea water, electrical leakage or electrical
or strong acid shock.
CAUTION
!
! doing so "
will damage the product, which !# %$$
may lead to electrical leakage or
electrical shock. Deterioration of the insulation
! may lead to electrical leakage,
! electrical shock, or fire.
Failure to observe
this caution could cause it to
malfunction or to operate abnor-
mally, which may lead to electri-
cal leakage or electrical shock.
35(&$87,216'85,1*0$,17(1$1&($1',163(&7,21
WARNING
Absolutely turn off the power OFF Do not disassemble or repair any
supply or disconnect the plug parts other than those designated
before starting maintenance or in the operation manual. If repairs
inspection. Do not work with wet are necessary in any other than
hands. Failure to observe these the designated parts, consult with
cautions may lead to electrical the dealer where it was
shock or injury. STOP purchased or Tsurumi representa-
tive. Improper repairs can
In case any abnormality (excessive result in electrical leakage,
vibration, unusual noise or odor) is electrical shock, fire, or water
found in the operation, turn the OFF leakage.
power off immediately and consult
with the dealer where it was
purchased or Tsurumi representa-
tive. Continuing to operate the
product under abnormal condi-
tions may result in electrical
shock, fire, or water leakage.
CAUTION
After reassembly, always perform a test operation before resuming use of the
product. Improper assembly can result in electrical leakage, electrical Test
shock, fire, or water leakage. operation
35(&$87,217232:(5287$*(
WARNING
power
In case of power outage, turn off the power supply. The product will resume outage
operation when the power is restored, which presents serious danger to
people in the vicinity. OFF
27+(535(&$87,21
CAUTION
Never use the product for potable water. It may present a danger to human
health. Potable
Water
3$571$0(6
([DPSOH
Handle
Cabtyre Cable
Oil Lifter
Mechanical Seal
Oil
Oil Casing Oil Plug
Hose Coupling Shaft Sleeve
Pump Casing Impeller
Stirrer
Casing Packing Strainer Stand
35,257223(5$7,21
$IWHUXQSDFNLQJYHULI\WKHFRQWHQWV
3URGXFW,QVSHFWLRQ
,QVSHFWWKHSURGXFWIRUGDPDJHGXULQJVKLSPHQWDQGPDNHVXUHDOOEROWVDQGQXWVDUHWLJKWHQHGSURSHUO\
6SHFLÀFDWLRQ&KHFN
&KHFNWKHQDPHSODWHRIWKHXQLWWRYHULI\WKDWLWLVWKHSURGXFWWKDW\RXKDYHRUGHUHG3D\SDUWLFXODUDWWHQWLRQ
WRLWVYROWDJHDQGIUHTXHQF\VSHFLÀFDWLRQV
Note: ZDVSXUFKDVHGRUWKH7VXUXPLVDOHVRI¿
,I\RXGLVFRYHUDQ\GDPDJHRUGLVFUHSDQF\LQWKHSURGXFWSOHDVHFRQWDFWWKHGHDOHUZKHUHWKLVHTXLSPHQW
FHLQ\RXUDUHD
$FFHVVRU\&KHFN
9HULI\WKDWDOODFFHVVRU\LWHPVDUHLQFOXGHGLQWKHSDFNDJH
+RVH%DQG SF
2SHUDWLRQ0DQXDO
Note: ,I\RXGLVFRYHUDQ\GDPDJHRUGLVFUHSDQF\LQWKHSURGXFWSOHDVHFRQWDFWWKHGHDOHUZKHUHWKLVHTXLSPHQW
ZDVSXUFKDVHGRUWKH7VXUXPLVDOHVRI¿FHLQ\RXUDUHD
3URGXFW6SHFLÀFDWLRQV
CAUTION 'RQRWRSHUDWHWKLVSURGXFWXQGHUDQ\FRQGLWLRQVRWKHUWKDQWKRVHWKDWKDYH
EHHQVSHFLÀHG
0DMRU6WDQGDUG6SHFLÀFDWLRQV
+*/&/0"* 4*! 0".&*0"..+1*!0".*! ..&*$0".
,,(& ("&-1&!/
"),".01." 1! ..4&*$0". 5 6
),"((". +.0"34,"
1), %#0"( +1("" %*& ("(
".&*$ %&"(!"!((".&*$
," &#& 0&+*/ .41)"./&("*!1 0&+*+0+.+("
*/1(0&+* (//
+0+.
&*&01.",.+0" 0+. '
.+0" 0&+*4/0")1&(0&*
&. ("0%".)(,.+0" 0+. '
1.& *0 1.&*"+&( *+*!!&0&2"
+**" 0&+* +/"+1,(&*$
6WDQGDUGVSHFLÀFDWLRQV +]
Model Bore Phase Starting Output Max.Head Max.capacity WHT
Method (m) (m3/min)
(mm) (kW) (ft.) (GPM) (kg)
12 0.200
HS2.4S 50 1 Capacitor-Run 0.4 39 53 11.3
12 0.200
HSE2.4S 50 1 Capacitor-Run 0.4 39 53 11.9
12 0.200
HSZ2.4S 50 1 Capacitor-Run 0.4 39 53 11.3
HS2.75S 50 1 Capacitor-Run 0.75 18/19
59/62
0.23/0.21
61/55 19.0
HS3.75S 80 1 Capacitor-Run 0.75 18/19
59/62
0.30/0.23
79/61 19.6
HSZ2.75S 50 1 Capacitor-Run 0.75 18/19
59/62
0.23/0.21
61/55 19.0
HSZ3.75S 80 1 Capacitor-Run 0.75 18/19
59/62
0.30/0.23
79/61 19.6
,167$//$7,21
CAUTION 7KHVXSSO\YROWDJHVKRXOGEHZLWKLQRIWKHUDWHGYROWDJH
7KHZDWHUWHPSHUDWXUHIRURSHUDWLQJWKHSXPSVKRXOGEHEHWZHHQaʝ
)DLOXUHWRREVHUYHWKHSUHFDXWLRQVJLYHQDERYHFRXOGFDXVHWKHSXPSWR
PDOIXQFWLRQZKLFKPD\OHDGWRFXUUHQWOHDNDJHRUHOHFWULFDOVKRFN
Note: 7RXVHWKHSXPSIRUDVSHFLDOVROXWLRQFRQWDFWWKHGHDOHUZKHUHLWZDVSXUFKDVHGRUWKH7VXUXPLVDOHVRI
¿FHLQ\RXUDUHD
&ULWLFDO8VH3UHVVXUH
CAUTION 'RQRWRSHUDWHWKHSXPSLQDQDUHDWKDWLVH[SRVHGWRDZDWHUSUHVVXUHWKDW
H[FHHGVWKHYDOXHVJLYHQEHORZ
3UHSDUDWLRQIRU,QVWDOODWLRQ
6LQJOHSKDVHSRZHUVXSSO\
8VHDPHJJHUWRPHDVXUHWKHUHVLVWDQFHEHWZHHQWKHWLSRIWKHFDEW\UHFDEOHSOXJ
DQGWKHJURXQGWHUPLQDOWRYHULI\WKHLQVXODWLRQUHVLVWDQFHRIWKHPRWRU
0HDVXUHWZLFHWKHUHVLVWDQFHEHWZHHQHDFKRIWKHWZRWLSVRIWKHSOXJDQGJURXQG
7KLVGLDJUDPVKRZVDSLQSOXJW\SH
CAUTION %HZDUHWKDWWKHSRZHUSOXJYDULHVE\FRXQWU\RUUHJLRQ
,QVXODWLRQUHVLVWDQFHUHIHUHQFHYDOXH 0ȍPLQLPXP
Note: 7KHLQVXODWLRQUHVLVWDQFHUHIHUHQFHYDOXHRI0ȍPLQLPXPLVEDVHGRQDQHZRUUHSDLUHGSXPS)RUUHIHU
HQFHYDOXHVRIDSXPSWKDWKDVDOUHDG\EHHQSXWLQWRRSHUDWLRQUHIHUWR0DLQWHQDQFHDQG,QVSHFWLRQRI
WKLVPDQXDO
+RZWRXVHOHYHOUHOD\XQLW +6(6+6=6
CAUTION 'RQRWPHDVXUHWKHLQVXODWLRQUHVLVWDQFHZLWKLQVXODWLRQ
UHVLVWDQFHWHVWHUIRUIROORZLQJSDUWV,WFDXVHVDWURXEOH
'RQRWOLIWRUKDQJWKHOHYHOUHOD\XQLW,WZLOOGDPDJHDQG
FDXVHDOHDNDJHDQHOHFWULFVKRFNDQGDÀUH
,QWKHFDVHRIWKHÁRDWW\SHGRQRWOLIWLWE\WKHÁRDW
FDEOHDVLWZLOOGDPDJHWKHFDEOHDQGOHDGWRDOHDNDJH
HOHFWULFDOVKRFNDQGÀUH
EHWZHHQWKHSOXJ EHWZHHQWKHHOHFWURGHRID EHWZHHQWKHHOHFWURGHRIDOHYHO
OHYHOUHOD\XQLW UHOD\XQLWDQGDSOXJ
'RQRWPDNH³RQ´SHULRGEHWZHHQWKHRWKHUOHYHOUHOD\XQLW
3UHFDXWLRQV'XULQJ,QVWDOODWLRQ
WARNING :KHQLQVWDOOLQJWKHSXPSEHPLQGIXORIWKHSXPS VFHQWHURIJUDYLW\DQG
ZHLJKW,IWKHSXPSLVQRWVXVSHQGHGSURSHUO\WKHSXPSPD\IDOODQGEUHDN
ZKLFKPD\OHDGWRLQMXU\
CAUTION :KHQLQVWDOOLQJRUPRYLQJWKHSXPS
QHYHUVXVSHQGWKHSXPSE\WKH
Hose Band
Hose
Discharge Connection
FDEW\UHFDEOH'RLQJVRZLOOGDPDJH Hose Coupling
WKHFDEOHZKLFKPD\FDXVHDFXUUHQW
OHDNDJHHOHFWULFDOVKRFNRUÀUH
:KHQDKRVHLVXVHGDWWDFKWKHKRVHWRWKHKRVHFRXSOLQJDVIDUDVLWZLOOJRWKHQ
IDVWHQLWVHFXUHO\ZLWKDKRVHEDQG
+DQGOHWKHSXPSFDUHIXOO\ZLWKRXWDSSO\LQJVKRFNWRLWVXFKDVE\GURSSLQJLW7R
Rope
VXVSHQGWKHSXPSGRVRPDQXDOO\RUE\DWWDFKLQJDURSHRUFKDLQWRLWVKDQGOHV
CAUTION 7KHURSHIRUVXVSHQGLQJWKHSXPSGXULQJLWVLQVWDOODWLRQ
PXVWEHRIDWKLFNQHVVWKDWDFFRPPRGDWHVWKHZHLJKW
RIWKHSXPS:KHQXVLQJDFKDLQPDNHVXUHWKDWWKH
FKDLQGRHVQRWEHFRPHWZLVWHG)DLOXUHWRREVHUYHWKHVH
SUHFDXWLRQVFRXOGFDXVHWKHURSHRUFKDLQWREUHDNDQGWKH
SXPSWRIDOODQGEUHDNZKLFKFRXOGOHDGWRSHUVRQDOLQMXU\
2SHUDWHWKHSXPSLQDORFDWLRQWKDWKDVDVXI¿FLHQWZDWHUOHYHODQGFROOHFWVZDWHUHDVLO\
Note: )RUWKHZDWHUOHYHOUHTXLUHGIRURSHUDWLQJWKHSXPSUHIHUWRWKH
H[WHUQDOGLPHQVLRQGUDZLQJZKLFKLVSURYLGHGVHSDUDWHO\
Backflow Outflow
5RXWHWKHKRVHDVVWUDLJKWDVSRVVLEOH([FHVVLYHEHQGLQJRIWKH
KRVHFRXOGREVWUXFWWKHÀRZRIZDWHUUHGXFHWKHSXPSLQJYROXPHRU
FORJWKHSXPSZLWKPXGWKXVGLVDEOLQJWKHSXPSLQJIXQFWLRQ
,IWKHKRVHLVNLQNHGDWLWVEDVHLWZLOOFUHDWHDLUSRFNHWVLQWKH
SXPSPDNLQJWKHSXPSRSHUDWHGU\7RSUHYHQWWKLVIURPRFFXUULQJ
VWUDLJKWHQWKHEHQGZKLOHRSHUDWLQJWKHSXPS
CAUTION ,IWKHSXPSGUDZVLQDODUJHDPRXQWRIPXGLWFRXOGFDXVHWKHSXPSWRZHDU
SUHPDWXUHO\DQGOHDGWRDPDOIXQFWLRQFXUUHQWOHDNDJHDQGHOHFWULFDOVKRFN
2SHUDWHWKHSXPSXSULJKW,IWKHUHLVWKHOLNHOLKRRGRIWKHSXPSGUDZLQJLQH[FHVVPXGSODFHDFRQFUHWH
EORFNXQGHUWKHSXPS
,QVWDOOLQJWKH)ORDW
6HWWKHOHQJWKRIWKHÁRDWOHDGZLUHWRWKHGLPHQVLRQLQGLFDWHGEHORZ)DLO L
XUHWRREVHUYHWKLVZLOOOHDGWRDQLPSURSHURSHUDWLRQ
Pump model L
HSZ2.4S 150mm
HSZ2.75S/HSZ3.75S 150mm
CAUTION ,QVWDOOWKHÁRDWVRWKDWLVPRYHVSURSHUO\
XSDQGGRZQ,IWKHÁRDWJHWVFDXJKWLWZLOO
FDXVHWKHSXPSWRRSHUDWHLPSURSHUO\
(/(&75,&$/:,5,1*
(OHFWULFDO:LULQJ:RUN
WARNING $OOHOHFWULFDOZRUNPXVWEHSHUIRUPHGE\DQDXWKRUL]HGHOHFWULFLDQ
LQFRPSOLDQFHZLWKORFDOHOHFWULFDOHTXLSPHQWVWDQGDUGVDQGLQWHUQDO
ZLULQJFRGHV1HYHUDOORZDQXQDXWKRUL]HGSHUVRQWRSHUIRUPHOHFWULFDO
ZRUNEHFDXVHLWLVQRWRQO\DJDLQVWWKHODZEXWLWFDQDOVREHH[WUHPHO\
GDQJHURXV
,PSURSHUZLULQJFDQOHDGWRFXUUHQWOHDNDJHHOHFWULFDOVKRFNRUÀUH
$EXVROXWHO\SURYLGHDGHGLFDWHGHDUWKOHDNDJHFLUFXLWEUHDNHUDQGDWKHUPDO
RYHUORDGUHDO\VXLWDEOHIRUWKHSXPS DYDLODEOHRQWKHPDUNHW )DLOXUH
WRIROORZWKLVZDUQLQJFDQFDXVHHOHFWULFDOVKRFNRUH[SORVLRQZKHQWKH
SURGXFWIDLOVRUDQHOHFWULFDOOHDNDJHRFFXUV
2SHUDWHZHOOZLWKLQWKHFDSDFLW\RIWKHSRZHUVXSSO\DQGZLULQJ
*URXQGLQJ
WARNING %HVXUHWRLQVWDOOWKHJURXQGZLUHVHFXUHO\)DLOXUHWRREVHUYHWKLVSUHFDXWLRQ
FRXOGGDPDJHWKHSXPSDQGFDXVHFXUUHQWOHDNDJHZKLFKPD\OHDGWR
HOHFWULFDOVKRFN
CAUTION 'RQRWFRQQHFWWKHJURXQGZLUHWRDJDVSLSHZDWHUSLSHOLJKWQLQJURGRU
WHOHSKRQHJURXQGZLUH,PSURSHUJURXQGLQJFRXOGFDXVHHOHFWULFDOVKRFN
&RQQHFWLQJWKH3RZHU3OXJ
WARNING %HIRUHLQVHUWLQJWKHSRZHUSOXJRUFRQQHFWLQJWKHZLUHVWRWKHWHUPLQDO
ERDUGPDNHVXUHWKDWWKHSRZHUVXSSO\ LHFLUFXLWEUHDNHU LVSURSHUO\
GLVFRQQHFWHG)DLOXUHWRGRVRPD\OHDGWRHOHFWULFDOVKRFNVKRUWRULQMXU\
FDXVHGE\WKHXQLQWHQGHGVWDUWLQJRIWKHSXPS
CAUTION 'RQRWXVHGDPDJHGFDEW\UHFDEOHVSRZHUSOXJVRUORRVHSRZHURXWOHWV
)DLOXUHWRREVHUYHWKLVSUHFDXWLRQFRXOGOHDGWRHOHFWULFDOVKRFNVKRUWFLUFXLW
RUÀUH
)ROORZWKHGLDJUDPRQWKHULJKWWRFRQQHFWWKHSRZHU
:KHQXVLQJDWKUHHSURQJJURXQGHGSOXJFRQQHFWDVVKRZQLQWKHGUDZLQJ
CAUTION %HVXUHWRXVHDGHGLFDWHG
SRZHUVXSSO\ZLWKDJURXQG
OHDNDJHFLUFXLWEUHDNHU
7KLVGLDJUDPVKRZVDSLQSOXJW\SH
CAUTION %HZDUHWKDWWKHSRZHUSOXJ
YDULHVE\FRXQWU\RUUHJLRQ
Note: 7KHVKDSHRIWKHSOXJPD\GLIIHUIURPWKDWVKRZQLQWKH
LOOXVWUDWLRQ
Single Phase
L1 L2 G
:KHQDVLQJOHSKDVHSRZHUVRXUFHLVXVHGFRQQHFWWKH Ground
OHDGVWRWKHFRQWUROSDQHOWHUPLQDOVDVVKRZQLQWKHGLDJUDP
PDNLQJVXUHWKH\GRQRWEHFRPHWZLVWHGWRJHWKHU
L1-Red(Brown) G-Green
L2-White(Blue) (Green/Yellow)
0RWRU3URWHFWRU
7KHSXPSLVHTXLSSHGZLWKDEXLOWLQPRWRUSURWHFWRU FLUFOHWKHUPDOSURWHFWRUPLQLDWXUHSURWHFWRU
,IDFXUUHQWRYHUORDGRURYHUKHDWLQJRFFXUVXQGHUWKHV\PSWRPVJLYHQEHORZWKHSXPSZLOOVWRSDXWRPDWLFDOO\
WRSURWHFWWKHPRWRUUHJDUGOHVVRIWKHZDWHUOHYHODWWKHWLPHRIRSHUDWLRQ
([WUHPHÁXFWXDWLRQRISRZHUVXSSO\YROWDJH
3XPSRSHUDWHGXQGHURYHUORDGFRQGLWLRQ
3XPSRSHUDWHGDWRSHQSKDVHRUELQGLQJFRQGLWLRQ
Note: $IWHUWKHPRWRUSURWHFWRUKDVWULSSHGWKHPRWRUDXWRPDWLFDOO\UHVXPHVLWVRSHUDWLRQ7KHUHIRUHPDNHVXUH
WRGLVFRQQHFWWKHFDEW\UHFDEOHIURPWKHWHUPLQDOERDUGRUWKHSRZHURXWOHWDQGHOLPLQDWHWKHFDXVHRIWKH
SUREOHP
'RQRWRSHUDWHWKHSXPSDWXQXVXDOO\ORZKHDGRUZLWKWKHLPSHOOHUFORJJHGZLWKGHEULV'RLQJVRZLOOQRW
RQO\SUHYHQWWKHSXPSIURPDWWDLQLQJLWVIXOOSRWHQWLDOEXWPD\DOVRJHQHUDWHDEQRUPDOQRLVHDQGYLEUDWLRQ
DQGGDPDJHWKHSXPS
(OHFWULFDO&LUFXLW'LDJUDPV
Non-Automatic Circuit Non-Automatic Circuit
HS2.4S HS2.75S / HS3.75S
Power Supply:Single-Phase Power Supply:Single-Phase
Red(Brown) Capacitor
Red Red Blue
L1 Circle Thermal Protector
Black Capacitor
Red(Brown) Red Blue Blue
White(Blue) L1
White
L2
Main Coil Aux.Coil Heater Black
Frame Grounding White(Blue)
Green White Main
L2 Frame Coil
(Green/Yellow) Green
Grounding
Green
Ground Miniature Protector (Green/Yellow)
Yellow/Green Aux.Coil
Ground
L1 Black
Triac
White(Blue) Electrode
L2 Transformer
White
Green
(Green/Yellow) Capacitor
Red Red Blue
Black
Ground White
Main Aux.
Miniature Coil
Frame Coil
Grounding Protector
Green
Power Supply: Float Switch (Normally open contact) Power Supply: Float Switch (Normally open contac)
Single-Phase Single-Phase Circle Thermal Protector
Capacitor Red(Brown) Capacitor
Red(Brown) Red Red Blue Red Blue Blue
L1 L1
Black
White(Blue) White Heater Black
White(Blue) White L2 Main
L2 Main Aux. Frame
Frame Green Grounding Coil
Coil Coil
Grounding Miniature (Green/Yellow)
Green
Protector
(Green/Yellow) Yellow/Green Aux.Coil
Green Ground
Ground
23(5$7,21
3ULRUWR2SHUDWLRQ
2QFHDJDLQFKHFNWKHQDPHSODWHRIWKHSXPSWRYHULI\WKDWLWVYROWDJHDQGIUHTXHQF\DUHFRUUHFW
CAUTION ,PSURSHUYROWDJHDQGIUHTXHQF\RIWKHSRZHUVXSSO\ZLOOSUHYHQWWKHSXPS
IURPDWWDLQLQJLWVIXOOSRWHQWLDODQGPD\DOVRGDPDJHWKHSXPS
&KHFNWKHZLULQJSRZHUVXSSO\YROWDJHWKHFDSDFLW\RIWKHJURXQGOHDNDJHFLUFXLWEUHDNHUDQGWKH
LQVXODWLRQUHVLVWDQFHRIWKHPRWRU
,QVXODWLRQUHVLVWDQFHUHIHUHQFHYDOXH 0ȍPLQLPXP
Note: 7KHLQVXODWLRQUHVLVWDQFHUHIHUHQFHYDOXHRI0ȍPLQLPXPLVEDVHGRQDQHZRUUHSDLUHGSXPS)RUUHIHU
HQFHYDOXHVRIDSXPSWKDWKDVDOUHDG\EHHQSXWLQWRRSHUDWLRQUHIHUWR0DLQWHQDQFHDQG,QVSHFWLRQ
:KHQXVLQJDJHQHUDWRUDVPXFKDVSRVVLEOHDYRLGRSHUDWLQJWKHSXPSLQFRQMXQFWLRQZLWKRWKHUW\SHV
RIHTXLSPHQW
121$8720$7,&23(5$7,21
7ULDO2SHUDWLRQ
WARNING 1HYHUVWDUWWKHSXPSZKLOHLWLVVXVSHQGHGDVWKHSXPSPD\MHUNDQGFDXVH
DVHULRXVDFFLGHQWLQYROYLQJLQMXU\
2SHUDWHWKHSXPSIRUDVKRUWWLPH PLQXWHV DQGYHULI\LWVRSHUDWLQJFRQGLWLRQV
CAUTION ,IWKHSXPSJHQHUDWHVDFRQVLGHUDEOHDPRXQWRIYLEUDWLRQQRLVHRUVPHOO
GLVFRQQHFWWKHSRZHUVXSSO\LPPHGLDWHO\DQGFRQWDFWWKHGHDOHUZKHUHWKH
SXPSSXUFKDVHGRUWKH7VXUXPLVDOHVRIÀFHLQ\RXUDUHD,IWKHSXPSLV
FRQWLQXHGWREHXVHGLQWKHDEQRUPDOVWDWHLWPD\FDXVHFXUUHQWOHDNDJH
HOHFWULFDOVKRFNRUÀUH
&RQWLQXHRSHUDWLRQLIQRDEQRUPDOFRQGLWLRQVDUHIRXQGGXULQJWKHWULDORSHUDWLRQ
2SHUDWLRQ
WARNING 7KHSXPSXQLWPD\EHH[WUHPHO\KRWGXULQJRSHUDWLRQ7RSUHYHQWEXUQVGR
QRWWRXFKWKHSXPSXQLWZLWKEDUHKDQGVGXULQJRUDIWHUWKHRSHUDWLRQ
3D\DWWHQWLRQWRWKHZDWHUOHYHOGXULQJWKHSXPSRSHUDWLRQ7KHSXPSPD\EHFRPHGDPDJHGLILWLVDOORZHG
WRRSHUDWHGU\
'XHWRDQRYHUORDGRSHUDWLRQRUDSXPSPDOIXQFWLRQLIWKHPRWRUSURWHFWRUWULSVWRVWRSWKHSXPSPDNHVXUH
WRHOLPLQDWHWKHFDXVHRIWKHSUREOHPEHIRUHUHVWDUWLQJ
Note: $ODUJHDPRXQWRIDPSHUDJHÀ
RZVZKHQDVXEPHUJLEOHSXPSLVVWDUWHGFDXVLQJWKHWHPSHUDWXUHRILWVZLQG
LQJVWRULVHUDSLGO\%HZDUHWKDWDIUHTXHQWVWRSDQGJRRSHUDWLRQRIWKHSXPSZLOODFFHOHUDWHWKHGHWHULRUD
WLRQRIWKHLQVXODWLRQRIWKHPRWRUZLQGLQJVDQGWKXVDIIHFWWKHXVHOLIHRIWKHPRWRU
2SHUDWLQJ:DWHU/HYHO
CAUTION 'RQRWRSHUDWHWKHSXPS
EHORZWKH&:/ &RQWLQXRXV
Pump Model C.W.L.
(mm)
5XQQLQJ:DWHU/HYHO HS2.4S 90
LQGLFDWHGEHORZ)DLOXUHWR HS2/3.75S 90
REVHUYHWKLVFRQGLWLRQPD\
UHVXOWLQGDPDJHWRWKHSXPS C.W.L
HOHFWULFDOOHDNDJHRUHOHFWULFDO
VKRFN
$XWRPDWLF2SHUDWLRQ IRUÁRDWW\SH
7ULDO2SHUDWLRQ Check float switch operation
(TXLSSHGZLWKÁRDWVWRGHWHFWWKHZDWHUOHYHOWKHDXWRPDWLFW\SH +6=
SXPSFDQSHUIRUPDQDXWRPDWLFGUDLQDJHRSHUDWLRQDORQHE\PHUHO\FRQ
QHFWLQJLWVFDEOHWRDSRZHUVXSSO\
&RQQHFWWKHSRZHUDQGSHUIRUPDWULDORSHUDWLRQDVIROORZV
'LUHFWDOOWKHÀRDWVGRZQZDUG Move
5DLVHWKH \HOORZ ÀRDW7KLVZLOOFDXVHWKHSXPSWRVWDUW
1H[WUHWXUQWKH \HOORZ ÀRDWWRWKHLURULJLQDOSRVLWLRQV7KLVZLOOFDXVH
WKHSXPSWRVWRS Float Switch
3HUIRUPVWHSV DQG FRQVHFXWLYHO\WZRRUPRUHWLPHVWRYHULI\WKH
RSHUDWLRQ
Note: 7KHWULDORSHUDWLRQPXVWEHFRPSOHWHGZLWKLQPLQXWH
CAUTION ,QFDVHWKHSXPSH[KLELWVDQDEQRUPDOFRQGLWLRQ VXFKDVDFRQVLGHUDEOH
DPRXQWRIYLEUDWLRQQRLVHRUVPHOO GLVFRQQHFWWKHSRZHUVXSSO\
LPPHGLDWHO\DQGFRQWDFWWKHGHDOHUZKHUH\RXSXUFKDVHGWKHHTXLSPHQWRU
7VXUXPL VVDOHVRIÀFHLQ\RXUDUHD,IWKHSXPSFRQWLQXHVWREHXVHGLQWKH
DEQRUPDOVWDWHLWPD\FDXVHFXUUHQWOHDNDJHHOHFWULFDOVKRFNRUÀUH
$XWRPDWLF2SHUDWLRQ IRUHOHFWURGHW\SH
2SHUDWLRQ:DWHU/HYHO
6WDUWRIWKHSXPS
7KHSXPSVWDUWVZKHQWKHFXUUHQWFRQWLQXRXVO\ÁRZVEHWZHHQWKHWZRHOHFWURGHVIRUPRUHWKDQRQH
VHFRQG
Note: ZKLFKWKHFXUUHQWGRHVQRWÀRZFDXVHRIKLJKVSHFL¿FUHVLVWDQFH
7KHHOHFWURGHPD\QRWGHWHFWWKHZDWHUVXUIDFHXQGHUFRQGLWLRQVVXFKDVSXUL¿HGZDWHURUGLVWLOODWHGZDWHU
Note: 7KHQHFHVVDU\ZDWHUOHYHOWR
In case of forced starting
RSHUDWHWKHSXPSLVPPIURP Level Relay Unit
WKHERWWRPRIDSXPS
,QFDVHRIVWDUWE\UDFLQJGXULQJ
WKHWULDORSHUDWLRQSOHDVHVKRUW Screw driver
FLUFXLWIRUPRUHWKDQRQH more than one (1) second
VHFRQGZLWKH[FLWLQJLWHPV
The lowest starting level
VFUHZGULYHUHWF EHWZHHQWKH
HOHFWURGHVDQGVWDUWIRUFLEO\
3OHDVHNHHSDZD\IURPWKRVHWKDW
PD\FORJLQDSXPS ZLUHQDLO 165mm
FRUGHWF
7ULDO2SHUDWLRQ
WARNING 1HYHUVWDUWWKHSXPSZKLOHLWLVVXVSHQGHGDVWKHSXPSPD\MHUNDQGFDXVH
DVHULRXVDFFLGHQWLQYROYLQJLQMXU\
2SHUDWHWKHSXPSWRPLQXWHVWRYHULI\WKHFRQGLWLRQVOLVWHGEHORZ
CAUTION ,QFDVHWKHSXPSH[KLELWVDQDEQRUPDOFRQGLWLRQ VXFKDVDFRQVLGHUDEOH
DPRXQWRIYLEUDWLRQQRLVHRUVPHOO GLVFRQQHFWWKHSRZHUVXSSO\
LPPHGLDWHO\DQGFRQWDFWWKHGHDOHUZKHUH\RXSXUFKDVHGWKHHTXLSPHQWRU
7VXUXPL VVDOHVRIÀFHLQ\RXUDUHD,IWKHSXPSFRQWLQXHVWREHXVHGLQWKH
DEQRUPDOVWDWHLWPD\FDXVHFXUUHQWOHDNDJHHOHFWULFDOVKRFNRUÀUH
3URFHHGZLWKWKHQRUPDORSHUDWLRQLIQRDEQRUPDOFRQGLWLRQVDUHIRXQGGXULQJWKHWULDORSHUDWLRQ
2SHUDWLRQ)ORZ&KDUW
7RHQDEOHWKHXVHUWREULQJWKHSXPSVDELOLW\LQWRIXOOSOD\WKLVFKDUWGHVFULEHVWKHYDULRXVFRQWUROPRGHVWKDW
DUHPDGHSRVVLEOHE\WKHFRPELQDWLRQVRIWKHHOHFWURGHDQGWLPHUIXQFWLRQV
Water
Level Relay Unit Pump Level Condition
[Switch on] Level Relay
The electrodes of the level relay unit are Unit
submerged, causing the current to operate
the pump.
Start
Operation Drop
Level Relay Unit (Drainage)
Electrode
Stop Rise
0$,17(1$1&($1',163(&7,21
5HJXODUPDLQWHQDQFHDQGLQVSHFWLRQDUHLQGLVSHQVDEOHWRPDLQWDLQLQJWKHSXPS VSHUIRUPDQFH,IWKH
SXPSEHKDYHVGLIIHUHQWO\IURPLWVQRUPDORSHUDWLQJFRQGLWLRQUHIHUWRVHFWLRQ7URXEOHVKRRWLQJDQGWDNH
DSSURSULDWHPHDVXUHVDWDQHDUO\VWDJH:HDOVRUHFRPPHQGWKDW\RXKDYHDVSDUHSXPSRQKDQGIRUDQ
HPHUJHQF\
3ULRUWR,QVSHFWLRQ
WARNING 0DNHVXUHWKDWWKHSRZHUVXSSO\ LHFLUFXLWEUHDNHU LVGLVFRQQHFWHGDQG
GLVFRQQHFWWKHFDEW\UHFDEOHIURPWKHSRZHURXWOHWRUUHPRYHLWIURPWKH
WHUPLQDOERDUG)DLOXUHWRGRVRPD\FDXVHHOHFWULFDOVKRFNRUXQLQWHQGHG
VWDUWLQJRIWKHSXPSZKLFKPD\OHDGWRVHULRXVDFFLGHQWV
:DVKLQJWKH3XPS
5HPRYHDQ\GHEULVDWWDFKHGWRWKHSXPS VRXWHUVXUIDFHDQGZDVKWKHSXPSZLWKWDSZDWHU3D\
SDUWLFXODUDWWHQWLRQWRWKHLPSHOOHUDUHDDQGFRPSOHWHO\UHPRYHDQ\GHEULVIURPWKHLPSHOOHU
,QVSHFWLQJWKH3XPS([WHULRU
9HULI\WKDWWKHUHLVQRGDPDJHDQGWKDWWKHEROWVDQGQXWVKDYHQRWORRVHQHG
Note: ,IWKHSXPSPXVWEHGLVDVVHPEOHGIRUUHSDLUGXHWRGDPDJHRUORRVHEROWVRUQXWVFRQWDFWWKHGHDOHUZKHUH
LWZDVSXUFKDVHGRUWKH7VXUXPLVDOHVRI¿FHLQ\RXUDUHD
'DLO\DQG3HULRGLF,QVSHFWLRQ
Interval Inspection Item
Measuring the operating current To be within the rated current
Daily Measuring the power voltage Power supply voltage variation
= within ± 10% of the rated voltage
Measuring the insulation resistance Insulation resistance reference value = 1MΩ minimum
Monthly [NOTE] The motor must be inspected if the insulation resistance is considerably lower
than the last inspection.
Inspecting oil 1,000 hours or 6 months, whichever comes first.
Semi-yearly
Inspection of liffting rope Replace if damage, corrosion, or wear has occurred to the rope.
Remove if foreign object is attaching to it.
Changing oil 2,000 hours or 12 months, whichever comes first.
Note: 5HIHUWRVHFWLRQ2LO,QVSHFWLRQDQG&KDQJH3URFHGXUHVEHORZIRUIXUWKHUGHWDLO
6WRUDJH
,IWKHSXPSZLOOQRWEHRSHUDWHGIRUDORQJSHULRGRIWLPHSXOOWKHSXPSXSZDVKWKHSXPSDOORZLWWRGU\
DQGVWRUHLWLQGRRUV
Note: )RUUHLQVWDOODWLRQEHVXUHWRSHUIRUPDWULDORSHUDWLRQEHIRUHSXWWLQJWKHSXPSLQWRRSHUDWLRQ
,IWKHSXPSUHPDLQVLPPHUVHGLQZDWHURSHUDWHLWRQDUHJXODUEDVLV LHRQFHDZHHN
2LO,QVSHFWLRQDQG&KDQJLQJ3URFHGXUHV
,QVSHFWLQJ2LO
5HPRYHWKHRLOSOXJDQGWDNHRXWDVPDOODPRXQWRI
RLO7KHRLOFDQEHH[WUDFWHGHDVLO\E\WLOWLQJWKHSXPS Oil Inlet
VRWKDWWKHRLO¿OOHUSOXJIDFHVGRZQZDUG,IWKHRLO Packing
DSSHDUVPLON\RULQWHUPL[HGZLWKZDWHUDOLNHO\FDXVH
LVDGHIHFWLYHVKDIWVHDOLQJGHYLFH LHPHFKDQLFDO
VHDO ZKLFKUHTXLUHVWKDWWKHSXPSEHGLVDVVHPEOHG
DQGUHSDLUHG
&KDQJLQJ2LO
5HPRYHWKHRLOSOXJDQGGUDLQWKHRLOFRPSOHWHO\ Hex Key Wrench
3RXUDVSHFL¿HGYROXPHRIRLOLQWRWKHRLO¿OOHULQOHW Oil Plug
Note: 7KHGUDLQHGRLOPXVWEHGLVSRVHGRISURSHUO\WRSUH
Specified Oil: Turbine Oil VG32 (non-additive)
Unit : m
YHQWLWIURPEHLQJUHOHDVHGLQWRWKHVHZHURUULYHUV
Pump Model Specified
7KHSDFNLQJRUWKH2ULQJIRUWKHRLOSOXJPXVWEH Volume
UHSODFHGZLWKDQHZSDUWDWHDFKRLOLQVSHFWLRQDQG HS2.4S,HSE2.4S,HSZ2.4S 160
FKDQJH HS2/3.75S,HSZ2/3.75S 160
5HSODFHPHQW3DUWV
7KHWDEOHOLVWVWKHSDUWVWKDWQHHGWREHUHSODFHGSHULRGLFDOO\5HSODFHWKHVHXVLQJWKHUHFRPPHQGHGIUH
TXHQF\DVDJXLGHOLQH
',6$66(0%/<$1'5($66(0%/<352&('85(
3ULRUWR'LVDVVHPEO\DQG5HDVVHPEO\
WARNING %HIRUHGLVDVVHPEOLQJDQGUHDVVHPEOLQJWKHSXPSEHVXUHWKDWWKHSRZHU
VXSSO\ LHFLUFXLWEUHDNHU LVGLVFRQQHFWHGDQGUHPRYHWKHFDEW\UHFDEOH
IURPWKHRXWOHWRUWKHWHUPLQDOERDUG'RQRWFRQQHFWRUGLVFRQQHFWWKH
SRZHUSOXJZLWKDZHWKDQGLQRUGHUWRSUHYHQWHOHFWULFDOVKRFN'RQRW
SHUIRUPDQDFWLYDWLRQWHVW WRFKHFNWKHURWDWLRQRIWKHLPSHOOHU GXULQJ
GLVDVVHPEO\DQGUHDVVHPEO\)DLOXUHWRREVHUYHWKLVSUHFDXWLRQFRXOG
OHDGWRDVHULRXVDFFLGHQWLQFOXGLQJLQMXU\
7KLVVHFWLRQH[SODLQVWKHGLVDVVHPEO\DQGUHDVVHPEO\SURFHVVHVWKDWDUHLQYROYHGXSWRWKHUHSODFHPHQW
RIWKHLPSHOOHULWVHOI2SHUDWLRQVLQYROYLQJWKHGLVDVVHPEO\DQGUHDVVHPEO\RIWKHVHDOLQJSRUWLRQ LH
PHFKDQLFDOVHDO DQGRIWKHPRWRUUHTXLUHDVSHFLDOL]HGIDFLOLW\LQFOXGLQJYDFXXPDQGHOHFWULFDOWHVWHTXLS
PHQW)RUWKHVHRSHUDWLRQVFRQWDFWWKHGHDOHUZKHUHWKLVHTXLSPHQWZDVSXUFKDVHGRUWKH7VXUXPLVDOHV
RIÀFHLQ\RXUDUHD
'LVDVVHPEO\3URFHGXUH
Note: )RUDVVHPEO\RUGLVDVVHPEO\SODFHWKHSXPSRQLWVVLGH
5HPRYHWKH+H[%ROWV DQG+H[1XWV WKHQUHPRYHWKH6WUDLQHU6WDQGDQG3XPS&DVLQJ
'LVDVVHPEO\'LDJUDP
Casing Packing
([DPSOH
Shaft Sleave
Impeller
Plain Washer
2 Hex.Nut
Spring Washer
Pump Casing
Stirrer
Strainer Stand
Hex.Bolt
Hose Coupling
Packing
Plain Washer
Hex.Nut
1 Hex.Bolt
5HDVVHPEO\3URFHGXUH
5HDVVHPEO\FDQEHSHUIRUPHGE\UHYHUVLQJWKHVWHSVIRUGLVDVVHPEO\
5HPRYHVDQGDQGRWKHUGHEULVIRUPUXEEHUSDUWVVXFK
DVWKH,PSHOOHUDQG&DVLQJ3DFNLQJEHIRUHDVVHPEOLQJ
WKHSXPS
Oil Casing
0DNHVXUHWKH&DVLQJ3DFNLQJ¿WVVQXJJO\DJDLQVWWKH
2LO&DVLQJ
:KHQWLJKWHQLQJWKH6WLUUHUGRQRWDSSO\H[FHVVLYHIRUFH
WKDWPLJKWGHIRUPWKHLPSHOOHURUFDXVHWKHUXEEHUOLQHU
WRÀDNHRII Casing Packing
Shaft Sleeve
7528%/(6+227,1*
WARNING 7RSUHYHQWVHULRXVDFFLGHQWVGLVFRQQHFWWKHSRZHUVXSSO\EHIRUHLQVSHFWLQJ
WKHSXPS
5HDGWKLV2SHUDWLRQ0DQXDOFDUHIXOO\EHIRUHUHTXHVWLQJUHSDLU$IWHUUHLQVSHFWLQJWKHSXPSLILWGRHVQRW
RSHUDWHQRUPDOO\FRQWDFWWKHGHDOHUZKHUHWKLVHTXLSPHQWZDVSXUFKDVHGRUWKH7VXUXPLVDOHVRI¿FHLQ\RXU
DUHD
7KHIROORZLQJLQIRUPDWLRQLVUHTXLUHGZKHQRUGHULQJUHSDLUVRUPDNLQJRWKHULQTXLULHV
Product model
Manufacturing number
Purchase date
Remarks
'LVSRVDORI3URGXFW
3URSHUO\GLVSRVHRIWKHSURGXFWE\GLVDVVHPEOLQJLWSUHVRUWLQJWKHFRQWHQWVDQGVHQGLQJWKHPWRWKHZDVWH
PDWHULDOWUHDWPHQWVLWH
Instruction Manual
Serial number :
Installation Date :
T20769EU-7
INSTRUCTION MANUAL
Be sure to read through this manual to gain full understanding before proceeding to actual operation.
Please retain this manual for future reference.
SAFETY PRECAUTIONS
Read the precautions carefully before operating the unit. The contents of this section are vital to
ensure safety. Please pay special attention to the following sign.
• WARNING
Indicates a potentially hazardous situation which, if not avoided, could result in death or serious
injury.
• CAUTION
Indicates a potentially hazardous situation which, if not avoided, could result in minor or moderate
injury and/or property damage.
WARNING
This appliance is not intended for use by persons (including children) with reduced physical,
sensory or mental capabilities, or lack of experience and knowledge, unless they have been given
supervision or instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or
similarly qualified persons in order to avoid a hazard.
• CAUTION – Do not step on the blower or place any object on the blower
Neglecting this note may cause damage to the blowers and/or injury.
1
For Installers
Installation
• CAUTION
The pump should be installed in a well ventilated place and away from direct sunlight
preferably undercover.
Install the pump in a place which has neither direct rain water splashing nor water
immersion.
Do not install the pump at the place which is under the kitchen fan or possible to take air
including oil into the pump.
Avoid installing the pump in a bedroom or other places where noises may be a
nuisance.
Install the pump in a place that provides easy access for inspection and maintenance.
• WARNING
All electrical work must be performed by a licensed electrician.
Do not place any object on the power cord.
Neglecting this note may cause electric shock and/or fire.
• CAUTION
Install the pump unit close to an aeration tank preferably within 5 meters. Pipe work
should be with minimum bends.
Install the pump in a place where is apart from the building wall by over 20cm using a
concrete base so as not to transfer the vibration.
Make sure the concrete base is level.
Connect the pump and the pipe by a rubber tube tighten by a pinch cock.
Insert the power plug firmly into the power point. Pulling out a plug by the cable may
damage the cable.
The pump must be connected to a grounded, metallic, permanent wiring system, or an
equipment-grounding terminal or lead on the product.
2
Test Operation
• CAUTION
The unit must be filled with water up to the prescribed line before turning on the pump.
Make sure the unit is aerated properly.
Make sure the pump is making no abnormal noise and vibration.
Measure the working pressure between the unit and pump. The accepted value for the
pressure is ± 20% of the normal pressure which is specified on the blower name plate.
Suggested Installation
Power Cable
Base Concrete
3
Inspection and Maintenance as required
(1) Air Filter (2) Diaphragm / Valve
Inspect and clean every 3 or 4 months Replace every year
Replace every year If the diaphragm/valve becomes damaged, the automatic
-stop function engages (except MAC30R, 40R). Further
In order to optimize the lifespan of the air filter when it is action must be taken to rectify the problem or deterioration of
used in areas where dust accumulation may be high, the wastewater unit due to an inoperable blower may result.
frequent maintenance is required. If the air filter gets A discernable odour will be present in this event. The
too dirty, replacement will be necessary. diaphragm/valve assembly should be replaced before it gets
Failure to adhere to this note may damaged.
cause abnormal heat generation, an
Neglecting this note may adversely
Attention air flow volume decrease and/or
early breakage of the diaphragm. Attention affect the performance of the unit.
(3) Pressure
High pressure is strictly prohibited Caution! Working blower is hot
Irregular heat generation and/or early diaphragm
When in operation, the lower part of the
Attention breakage may result if operation of the blower is Warning blower gets hot. Do not touch directly.
sustained at an abnormally high pressure.
Neglecting this note may cause injury and burn.
Neglecting this note may cause material damage.
Make sure to turn off the power when replacing the diaphragm/valve assembly and/or handling
Warning the auto-stop piece. Neglecting this note may cause an electric shock.
(1) How to remove an auto-stop piece (2) How to set an auto-stop piece
4
Diaphragm Replacement Procedure
Do not remove
these screws!!
1. Remove cover bolts using a 2. Remove an auto-stop piece as 3. Remove a power cable from 4
8mm-box wrench or cross slot instructed above. hooks.
screwdriver. Attention Do not remove screws!!
4. Remove 4 screws from a 5. Remove Nylon nut and take a 6. Place a new diaphragm using
casing using a cross slot diaphragm off from a body. new Nylon nut provided.
screwdriver. *Tightening torque – about 1 Nm
7. Insert a casing air outlet into a 8. Fit a power cable in 4 hooks. 9. Set an auto-stop piece as
rubber grommet and fix a instructed above.
casing assembly with 4 screws.
FLOWED INTO THE WATER THROUGH A DIFFUSER. HIGH AERATION EFFICIENCY Oxygen Capability: 0.15 – 0.38
Oxygen Transfer Efficiency > 20
THE AIR THAT GOES INTO THE WATER WILL BE HIGH OXYGEN TRANSFER EFFICIENCY
Service Area: (m2/piece): 0.6 – 0.9
SHAPED BUBBLES. COARSE BUBBLE DIFFUSERS REQUIRE LESS ENERGY TO RUN
Design Air Flow (m3/h): 1.5 – 2.5
CAN PRODUCE 1/4 TO 1/2 INCH (6.4 TO 13 MM) AIR EASILY ADAPT TO EXISTING BASINS