Uncertainty Budget sebagai Pendukung Kemampuan Kalibrasi dan Pengukuran (CMC)
Nama laboratorium : PT NIPSEA PAINT AND CHEMICALS
Alamat : Subang,
Jawa Barat
UNCERTAINTY BUDGET SEBAGAI PENDUKUNG KLAIM CMC
Besaran yang diukur : Massa
Jenis alat yang dikalibrasi : Timbangan digital
Standar yang digunakan : Anak Timbang kelas F1
Model matematis pengukuran : Δ = R - S; Δ = koreksi, S = Pembacaan Alat, R = nilai standard
Rentang ukur : 100.00 g
Komponen Satuan Distribusi u Pembagi Vi ui
(1) (2) (3) (4) (5) (6) (7)
1. Repeatability mg Normal 11.40 3.16 9 3.6055513
2. Standard Anak Timbang mg Normal 2 60 0
3. Resolusi Alat mg Rect 0.50 1.73 1000 0.2886751
4. Massa Instability mg Rect 0.04 1.73 1000 0.023094
Sums max(
Ketidakpastian baku gabungan, uc,
Derajat kebebasan efektif, neff
Faktor cakupan, k-student’s untuk neff dan CL 95 %
Ketidakpastian bentangan, U = kuc,
Alamat Campaka-Purwakarta
DATA KALIBRASI
1. Repeatability 1/2 Kapasitas 2. Repeatability Maximum Kapasitas
Beban : 500 g Beban : 900 g
Zi Mi Selisih No Zi Mi Selisih
0.000 500.086 500.0860 1 0.000 900.127 900.1270
0.000 500.085 500.0850 2 0.001 900.122 900.1210
0.000 500.084 500.0840 3 0.000 900.100 900.1000
0.005 500.124 500.1190 4 0.006 900.120 900.1140
0.004 500.087 500.0830 5 0.007 900.125 900.1180
0.000 500.080 500.0800 6 0.004 900.111 900.1070
0.003 500.089 500.0860 7 0.000 900.121 900.1210
0.006 500.088 500.0820 8 0.005 900.119 900.1140
0.006 500.089 500.0830 9 0.004 900.110 900.1060
0.005 500.087 500.0820 10 0.005 900.124 900.1190
Skala Nominal
Center of Loading
Notes :
* Reported results only applicable to the calibrated devices.
* Correction are added to the equipment reading for obtaining true reading.
* The uncertainty of measurement at level of confidence of 95%, and the coverage factor is equal 2.
* Calculation of measurement uncertainty refers to ISO GUM 2008.
* The reported calibration results are traceable to SI units through -