PENGARUH LAJU ALIR FILTER WATER DENGAN LAJU
ALIR AIR LIMBAH TERHADAP PENURUNAN NILAI
CHEMICAL OXYGEN DEMAND (COD) PADA UNIT ANOKSIK
PT. ASIA PACIFIC FIBERS, Tbk.
Influence of Filter Water Flow Rate with Wastewater Flow Rate
Toward Reduction of Chemical Oxygen Demand (COD) Value in
Anoxic Unit PT. Asia Pacific Fibers, Inc.
TUGAS AKHIR
Oleh :
PENGARUH LAJU ALIR FILTER WATER DENGAN LAJU
ALIR AIR LIMBAH TERHADAP PENURUNAN NILAI
CHEMICAL OXYGEN DEMAND (COD) PADA UNIT ANOKSIK
PT. ASIA PACIFIC FIBERS, Tbk.
Influence of Filter Water Flow Rate with Wastewater Flow Rate
Toward Reduction of Chemical Oxygen Demand (COD) Value in
Anoxic Unit PT. Asia Pacific Fibers, Inc.
TUGAS AKHIR
Oleh :
JULI 2012
NIM : 091411043
KATA PENGANTAR
Bismillahirrahmanirrahim
Puji dan syukur penulis panjatkan kehadirat Allah SWT yang telah
memberikan rahmat dan karunia-Nya, sehingga penulis dapat menyelesaikan Tugas
Akhir ini sebagai salah satu syarat kelulusan pada Jurusan Teknik Kimia Politeknik
Negeri Bandung.
Penyusunan laporan ini tidak lepas dari bantuan berbagai pihak. Oleh karena
itu, penulis mengucapkan terima kasih kepada semua pihak yang telah memberikan
bantuan baik secara langsung maupun secara tidak langsung. Ucapan terima kasih
diberikan khususnya kepada :
1. Ir. Emma Hermawati, MT, selaku Dosen Pembimbing yang telah bersedia
untuk meluangkan waktu membimbing, memeriksa, dan memberikan
petunjuk-petunjuk serta saran dalam penyusunan laporan ini.
2. Ir. Dwi Nirwantoro Nur, M.Sc., selaku Ketua Jurusan Teknik Kimia
Politeknik Negeri Bandung
3. Rispiandi, ST, MT, selaku Koordinator Tugas Akhir Jurusan Teknik Kimia
Politeknik Negeri Bandung
4. Bapak Wahjoedi Priambodo, selaku pembimbing lapangan di PT. Asia Pacific
Fibers Tbk, Karawang yang telah membantu dalam hal pengumpulan data dan
perizinan.
5. Bapak Irawan, selaku staff yang telah membantu dalam hal pengumpulan data
6. Bapak Aif, bapak Carwan, dan bapak Amin, selaku staff yang ada di Instalasi
Pengolahan Air Limbah (IPAL) yang selalu memberikan saran dan bantuan
ketika penulis menghadapi kesulitan.
i
membalas segala amal budi serta kebaikan pihak-pihak yang telah membantu penulis
dalam penyusunan laporan ini dan semoga tulisan ini dapat bermanfaat bagi penulis
khususnya
dan bagi pembaca umumnya. Penulis menyadari bahwa laporan ini masih
jauh dari sempurna dan masih banyak kekurangan. Penulis mengharapkan saran dan
kritik yang membangun dari semua pihak. Atas segala perhatiannya, penulis
mengucapkan terima kasih.
Penulis
ii
ABSTRAK
Unit anoksik merupakan salah satu unit yang ada pada Instalasi Pengolahan Air
Limbah (IPAL) di PT. Asia Pacific Fibers, Tbk. Effluent dari unit anoksik akan
langsung dimasukkan ke dalam unit aerasi, tetapi permasalahan seringkali muncul
ketika effluent dari unit anoksik yang masuk ke dalam unit aerasi memiliki nilai
Chemical Oxygen Demand (COD) di atas 6000 ppm karena unit aerasi memiliki
standar nilai COD yang masuk tidak boleh melebihi nilai tersebut. Salah satu metoda
yang dilakukan
untuk memenuhi standar tersebut adalah menggunakan penambahan
filter water pada unit anoksik. Pada penelitian ini dipelajari pengaruh laju alir filter
water dengan laju alir air limbah terhadap penurunan nilai COD. Berbagai variasi
yang dilakukan adalah laju alir filter water, laju alir air limbah, dan nilai COD awal.
Hasil penelitian diperoleh pengaruh laju alir filter water dengan laju alir air limbah
terhadap penurunan nilai COD mengikuti persamaan y = 560,38x + 3524,8 terhadap
nilai COD awal dan persamaan y = 0,0018x – 3,474 terhadap penurunan nilai COD.
Kata kunci : unit anoksik, Chemical Oxygen Demand (COD), filter water, air limbah
iii
ABSTRACT
Anoxic unit is one unit of the Wastewater Treatment Plant (WWTP) in PT. Asia
Pacific Fibers, Tbk. Effluent from the anoxic unit will directly flow to the aeration
unit, but problems often arise when the anoxic unit’s effluent which enter the aeration
unit has a value of Chemical Oxygen Demand (COD) above 6000 ppm because the
aeration unit has a standard value for incoming COD that should not exceed that
value. One of the method to fulfilled that standard is adding filter water to the anoxic
unit. This
research was conducted to study about the influence of initial COD value
toward ratio of filter water flow rate with wastewater flow rate and the influence of
ratio of filter water flow rate with wastewater flow rate toward the decreasing of
COD value at the range of 5000 – 12000 ppm. From the research, the average ratio
between the flow rate of filter water with wastewater flow rate obtained followed the
equation y = 560,38x + 3524,8 toward initial COD value and equation y = 0,0018x –
3,474 toward decreasing of COD value.
Keywords : anoxic unit, Chemical Oxygen Demand (COD), filter water, wastewater
iv
DAFTAR ISI
HALAMAN
JUDUL
HALAMAN PENGESAHAN
KATA PENGANTAR .......................................................................................... i
ABSTRAK
............................................................................................................ iii
ABSTRACT
.......................................................................................................... iv
DAFTAR ISI ......................................................................................................... v
DAFTAR TABEL ................................................................................................. vii
DAFTAR GAMBAR ............................................................................................ viii
DAFTAR LAMPIRAN ......................................................................................... ix
BAB I PENDAHULUAN
1.1 Latar Belakang Penelitian ............................................................... 1
1.2 Tujuan Penelitian ............................................................................ 2
1.3 Ruang Lingkup Penelitian ............................................................... 2
1.4 Tahapan Penelitian .......................................................................... 3
1.5 Sistematika Penulisan...................................................................... 3
BAB II TINJAUAN PUSTAKA
2.1 Pengertian Limbah .......................................................................... 4
2.2 Karakteristik Limbah ...................................................................... 4
2.2.1 Sifat Fisik ........................................................................... 4
2.2.2 Sifat Kimia ......................................................................... 6
2.2.3 Sifat Biologi ....................................................................... 7
2.3 Chemical Oxigen Demand (COD) .................................................. 7
2.4 Pengolahan Limbah Cair ................................................................. 10
2.5 Sistem Pengolahan Air Limbah PT Asia Pacific Fibers, Tbk ......... 11
2.6 Pengenceran .................................................................................... 13
2.6.1 Macam-macam Pelarut....................................................... 13
2.6.2 Pembuangan dengan Pengenceran ..................................... 16
BAB III METODOLOGI PENELITIAN
3.1 Tahap Persiapan .............................................................................. 18
v
vi
DAFTAR TABEL
Tabel 4.1
Kalibrasi Laju Alir pada Bukaan Katup Filter Water ............................... 22
Tabel 4.1 Nilai COD dan pH Sebelum dan Sesudah Penambahan Filter Water
dengan Variasi Laju Alir Air Limbah dan Filter Water .......................... 23
Tabel 4.2 Rasio Rata-Rata (Laju Alir Filter Water / Laju Alir Air Limbah)............ 25
vii
DAFTAR GAMBAR
Gambar 2.1 Skema Instalasi Pengolahan Air Limbah PT. Asia Pacific Fibers
Tbk ....................................................................................................... 11
Gambar 3.1 Skema Langkah Penelitian .................................................................... 20
Gambar 3.2 Unit Anoksik Tampak Atas ................................................................... 21
Gambar 4.1 Kalibrasi Laju Alir pada Bukaan Katup Filter Water .......................... 23
viii
DAFTAR LAMPIRAN
LAMPIRAN A
Daftar Notasi ....................................................................................................... 30
LAMPIRAN
B
Gambar
B.1 Layout Intalasi Pengolahan Air Limbah ......................................... 32
Gambar B.2 Unit Anoksik A............................................................................... 33
LAMPIRAN C
LAMPIRAN D
LAMPIRAN E
ix
x
DAFTAR PUSTAKA
Anonim.
Tanpa tahun. Wastewater Treatment Methods and Disposal. (online),
(http://web.deu.edu.tr/atiksu/ana52/wtreat.html, diakses 22 juni 2012).
Aprimadini, Eva. 2009. Perubahan Iklim Global dan Kaitannya dengan
Pengendalian Pencemaran Air. (online),
(http://uwityangyoyo.wordpress.com/2009/11/10/perubahan-iklim-global-dan-
kaitannya-dengan-pengendalian-pencemaran-air/, diakses 12Juni 2012).
Effendi, H. 2003. Telaah Kualitas Air bagi Pengelolaan Sumber Daya dan
Lingkungan Perairan.Yogyakarta: Kanisius.
Fernandez, Borja. 2009. Tanpa Judul. (online),
(http://halamanputih.wordpress.com/tag/air-suling/, diakses 26 Juni 2012).
Ginting, Perdana. 2007. Sistem Pengelolaan Lingkungan dan Limbah Industri.
Bandung: YramaWidya.
Hidayat, Wahyu. 2008. Teknologi Pengolahan Air Limbah. (online),
(http://majarimagazine.com/2008/01/teknologi-pengolahan-air-limbah/,
diakses 07 Juli 2012).
Kristanto, Philip. 2002. Ekologi Industri. Yogyakarta: Penerbit Andi.
Metcalf and Eddy. 2004. Wastewater Engineering, 4th edition. New York
:McGraw Hill International Editions.
Nurhasanah. 2009. Penentuan Kadar COD (Chemical Oxygen Demand) pada
Limbah Cair Pabrik Kelapa Sawit, Pabrik Karet dan Domestik. (online),
(http://repository.usu.ac.id/bitstream/123456789/13930/1/09E02463.pdf,
diakses 12 April 2012)
Situmorang, M. 2007. Tekhnologi Penyediaan Air Bersih Edisi Kelima. Jakarta:
Kalma Media Pustaka.
Wardhana, Wisnu Arya. 1995. Dampak Pencemaran Lingkungan. Yogyakarta:
Andi Offset.
Widyabuningsih, Dewi. 2010. Pengelolaan Limbah Industri. Bandung: Politeknik
Negeri Bandung.
28