Anda di halaman 1dari 15

 

 
PENGARUH LAJU ALIR FILTER WATER DENGAN LAJU
ALIR AIR LIMBAH TERHADAP PENURUNAN NILAI
 
CHEMICAL OXYGEN DEMAND (COD) PADA UNIT ANOKSIK
  PT. ASIA PACIFIC FIBERS, Tbk.
  Influence of Filter Water Flow Rate with Wastewater Flow Rate
 
Toward Reduction of Chemical Oxygen Demand (COD) Value in
Anoxic Unit PT. Asia Pacific Fibers, Inc.
 

 
TUGAS AKHIR

Oleh :

ATWINDA SUKMA PUTRI NIM. 091411038

FAHMI NAZARUDIN ZUHRI NIM. 091411043

PROGRAM STUDI DIII TEKNIK KIMIA


JURUSAN TEKNIK KIMIA
POLITEKNIK NEGERI BANDUNG
JULI 2012

 
 

 
PENGARUH LAJU ALIR FILTER WATER DENGAN LAJU
ALIR AIR LIMBAH TERHADAP PENURUNAN NILAI
 
CHEMICAL OXYGEN DEMAND (COD) PADA UNIT ANOKSIK
  PT. ASIA PACIFIC FIBERS, Tbk.
  Influence of Filter Water Flow Rate with Wastewater Flow Rate
 
Toward Reduction of Chemical Oxygen Demand (COD) Value in
Anoxic Unit PT. Asia Pacific Fibers, Inc.
 

TUGAS AKHIR

Oleh :

ATWINDA SUKMA PUTRI NIM. 091411038

FAHMI NAZARUDIN ZUHRI NIM. 091411043

PROGRAM STUDI DIII TEKNIK KIMIA

JURUSAN TEKNIK KIMIA

POLITEKNIK NEGERI BANDUNG

JULI 2012

 
 

 
 

  Nama : Atwinda Sukma Putri


 
NIM : 091411038
 

  Tempat Tanggal Lahir : Bandung, 12 Februari 1992

  SD Lulus Tahun : 2003 di SDN Moh. Toha II


 
SLTP Lulus Tahun : 2006 di SLTPN 38 Bandung

SMA Lulus Tahun : 2009 di SMAN 11 Bandung

Nama : Fahmi Nazarudin Zuhri

NIM : 091411043

Tempat Tanggal Lahir : Malang, 07 November 1990

SD Lulus Tahun : 2003 di SDIT Al Irsyad Al Islamiyah

SLTP Lulus Tahun : 2006 di SMP Negeri 1 Karawang

SMA Lulus Tahun : 2009 di SMA Negeri 1 Karawang

 
 

  KATA PENGANTAR
 

Bismillahirrahmanirrahim
 

 
Puji dan syukur penulis panjatkan kehadirat Allah SWT yang telah
 
memberikan rahmat dan karunia-Nya, sehingga penulis dapat menyelesaikan Tugas
 
Akhir ini sebagai salah satu syarat kelulusan pada Jurusan Teknik Kimia Politeknik
Negeri  Bandung.
 
Penyusunan laporan ini tidak lepas dari bantuan berbagai pihak. Oleh karena
itu, penulis mengucapkan terima kasih kepada semua pihak yang telah memberikan
bantuan baik secara langsung maupun secara tidak langsung. Ucapan terima kasih
diberikan khususnya kepada :

1. Ir. Emma Hermawati, MT, selaku Dosen Pembimbing yang telah bersedia
untuk meluangkan waktu membimbing, memeriksa, dan memberikan
petunjuk-petunjuk serta saran dalam penyusunan laporan ini.
2. Ir. Dwi Nirwantoro Nur, M.Sc., selaku Ketua Jurusan Teknik Kimia
Politeknik Negeri Bandung
3. Rispiandi, ST, MT, selaku Koordinator Tugas Akhir Jurusan Teknik Kimia
Politeknik Negeri Bandung
4. Bapak Wahjoedi Priambodo, selaku pembimbing lapangan di PT. Asia Pacific
Fibers Tbk, Karawang yang telah membantu dalam hal pengumpulan data dan
perizinan.
5. Bapak Irawan, selaku staff yang telah membantu dalam hal pengumpulan data
6. Bapak Aif, bapak Carwan, dan bapak Amin, selaku staff yang ada di Instalasi
Pengolahan Air Limbah (IPAL) yang selalu memberikan saran dan bantuan
ketika penulis menghadapi kesulitan.

i
 
 

  7. Rekan-rekan Jurusan Teknik Kimia angkatan 2009 yang selalu memberikan

 dukungan dan saran.

 Akhir kata, semoga Allah SWT senantiasa melimpahkan karunia-Nya dan

  membalas segala amal budi serta kebaikan pihak-pihak yang telah membantu penulis
  dalam penyusunan laporan ini dan semoga tulisan ini dapat bermanfaat bagi penulis
khususnya
 
dan bagi pembaca umumnya. Penulis menyadari bahwa laporan ini masih
jauh dari sempurna dan masih banyak kekurangan. Penulis mengharapkan saran dan
 
kritik yang membangun dari semua pihak. Atas segala perhatiannya, penulis
 
mengucapkan terima kasih.

Bandung, Juli 2012

Penulis

ii
 
 

  ABSTRAK
 

 
Unit anoksik merupakan salah satu unit yang ada pada Instalasi Pengolahan Air
 
Limbah (IPAL) di PT. Asia Pacific Fibers, Tbk. Effluent dari unit anoksik akan
  langsung dimasukkan ke dalam unit aerasi, tetapi permasalahan seringkali muncul
ketika effluent dari unit anoksik yang masuk ke dalam unit aerasi memiliki nilai
Chemical  Oxygen Demand (COD) di atas 6000 ppm karena unit aerasi memiliki
standar nilai COD yang masuk tidak boleh melebihi nilai tersebut. Salah satu metoda
yang dilakukan
  untuk memenuhi standar tersebut adalah menggunakan penambahan
filter water pada unit anoksik. Pada penelitian ini dipelajari pengaruh laju alir filter
 
water dengan laju alir air limbah terhadap penurunan nilai COD. Berbagai variasi
yang dilakukan adalah laju alir filter water, laju alir air limbah, dan nilai COD awal.
Hasil penelitian diperoleh pengaruh laju alir filter water dengan laju alir air limbah
terhadap penurunan nilai COD mengikuti persamaan y = 560,38x + 3524,8 terhadap
nilai COD awal dan persamaan y = 0,0018x – 3,474 terhadap penurunan nilai COD.

Kata kunci : unit anoksik, Chemical Oxygen Demand (COD), filter water, air limbah

iii
 
 

  ABSTRACT
 

 
Anoxic unit is one unit of the Wastewater Treatment Plant (WWTP) in PT. Asia
 
Pacific Fibers, Tbk. Effluent from the anoxic unit will directly flow to the aeration
  unit, but problems often arise when the anoxic unit’s effluent which enter the aeration
unit has a value of Chemical Oxygen Demand (COD) above 6000 ppm because the
aeration  unit has a standard value for incoming COD that should not exceed that
value. One of the method to fulfilled that standard is adding filter water to the anoxic
unit. This
  research was conducted to study about the influence of initial COD value
toward ratio of filter water flow rate with wastewater flow rate and the influence of
 
ratio of filter water flow rate with wastewater flow rate toward the decreasing of
COD value at the range of 5000 – 12000 ppm. From the research, the average ratio
between the flow rate of filter water with wastewater flow rate obtained followed the
equation y = 560,38x + 3524,8 toward initial COD value and equation y = 0,0018x –
3,474 toward decreasing of COD value.
Keywords : anoxic unit, Chemical Oxygen Demand (COD), filter water, wastewater

iv
 
 

  DAFTAR ISI
 

HALAMAN
  JUDUL
  HALAMAN PENGESAHAN
  KATA PENGANTAR .......................................................................................... i
ABSTRAK
  ............................................................................................................ iii
ABSTRACT
  .......................................................................................................... iv
  DAFTAR ISI ......................................................................................................... v
DAFTAR TABEL ................................................................................................. vii
DAFTAR GAMBAR ............................................................................................ viii
DAFTAR LAMPIRAN ......................................................................................... ix
BAB I PENDAHULUAN
1.1 Latar Belakang Penelitian ............................................................... 1
1.2 Tujuan Penelitian ............................................................................ 2
1.3 Ruang Lingkup Penelitian ............................................................... 2
1.4 Tahapan Penelitian .......................................................................... 3
1.5 Sistematika Penulisan...................................................................... 3
BAB II TINJAUAN PUSTAKA
2.1 Pengertian Limbah .......................................................................... 4
2.2 Karakteristik Limbah ...................................................................... 4
2.2.1 Sifat Fisik ........................................................................... 4
2.2.2 Sifat Kimia ......................................................................... 6
2.2.3 Sifat Biologi ....................................................................... 7
2.3 Chemical Oxigen Demand (COD) .................................................. 7
2.4 Pengolahan Limbah Cair ................................................................. 10
2.5 Sistem Pengolahan Air Limbah PT Asia Pacific Fibers, Tbk ......... 11
2.6 Pengenceran .................................................................................... 13
2.6.1 Macam-macam Pelarut....................................................... 13
2.6.2 Pembuangan dengan Pengenceran ..................................... 16
BAB III METODOLOGI PENELITIAN
3.1 Tahap Persiapan .............................................................................. 18

v
 
 

  3.2 Tahap Pelaksanaan .......................................................................... 18


3.2.1 Observasi Lapangan ........................................................... 18
  3.2.2 Kalibrasi Laju Alir ............................................................. 19
3.3 Tahap Pengolahan Data................................................................... 19
 
3.4 Tahap Akhir .................................................................................... 19
 
BAB IV HASIL DAN PEMBAHASAN
 
4.1 Kalibrasi Laju Alir untuk Bukaan Katup Filter Water ................... 22
 4.2 Pengaruh Penambahan Filter Water terhadap Nilai COD di
Unit Anoksik ................................................................................... 23
 4.3 Rasio Rata-Rata antara Laju Alir Filter Water dengan Laju
Alir Air Limbah terhadap COD Awal ............................................. 25
  4.3 Hubungan Rasio Rata-Rata terhadap Penurunan COD ................... 26
BAB V KESIMPULAN
5.1 Kesimpulan ..................................................................................... 28
5.2 Saran................................................................................................ 28

DAFTAR PUSTAKA ........................................................................................... 29


LAMPIRAN

vi
 
 

  DAFTAR TABEL
 

Tabel 4.1
  Kalibrasi Laju Alir pada Bukaan Katup Filter Water ............................... 22
 
Tabel 4.1 Nilai COD dan pH Sebelum dan Sesudah Penambahan Filter Water
 

  dengan Variasi Laju Alir Air Limbah dan Filter Water .......................... 23
 
Tabel 4.2 Rasio Rata-Rata (Laju Alir Filter Water / Laju Alir Air Limbah)............ 25
 

Tabel 4.3 Rasio Rata-Rata dan Penurunan COD Rata-Rata ..................................... 26

vii
 
 

  DAFTAR GAMBAR
 

Gambar  2.1 Skema Instalasi Pengolahan Air Limbah PT. Asia Pacific Fibers
  Tbk ....................................................................................................... 11
 
Gambar  3.1 Skema Langkah Penelitian .................................................................... 20

 
Gambar 3.2 Unit Anoksik Tampak Atas ................................................................... 21
 

Gambar 4.1 Kalibrasi Laju Alir pada Bukaan Katup Filter Water .......................... 23

Gambar 4.2 Nilai COD Awal terhadap Rasio Rata-Rata .......................................... 26

Gambar 4.3 Rasio Rata-Rata terhadap Penurunan Nilai COD ................................. 27

viii
 
 

  DAFTAR LAMPIRAN
 

 
LAMPIRAN A
 
Daftar Notasi ....................................................................................................... 30
 

LAMPIRAN
  B

Gambar
  B.1 Layout Intalasi Pengolahan Air Limbah ......................................... 32
 
Gambar B.2 Unit Anoksik A............................................................................... 33

Gambar B.3 Unit Aerasi A .................................................................................. 33

Gambar B.4 Unit Aerasi B .................................................................................. 34

Gambar B.5 Dump Tank ..................................................................................... 34

LAMPIRAN C

Data dan Perhitungan .......................................................................................... 36

LAMPIRAN D

Spesifikasi Instalasi Pengolahan Air Limbah .................................................... 40

Parameter Filter Water ....................................................................................... 46

LAMPIRAN E

Peraturan Menteri Negara Lingkungan Hidup Nomor 8 Tahun 2007 ............... 48

Standar IPAL PT. Asia Pacific Fibers, Tbk ....................................................... 53

ix
 
 

  SK Gubernur No. 6 Tahun 1999 Lampiran III ................................................... 55

x
 
 

 
DAFTAR PUSTAKA

Anonim.
  Tanpa tahun. Wastewater Treatment Methods and Disposal. (online),
(http://web.deu.edu.tr/atiksu/ana52/wtreat.html, diakses 22 juni 2012).
 
Aprimadini, Eva. 2009. Perubahan Iklim Global dan Kaitannya dengan
  Pengendalian Pencemaran Air. (online),
(http://uwityangyoyo.wordpress.com/2009/11/10/perubahan-iklim-global-dan-
 kaitannya-dengan-pengendalian-pencemaran-air/, diakses 12Juni 2012).

  J. E. 1999. Kimia Universitas Asas dan Struktur. Jakarta: Binarupa Aksara.


Brady,

  Effendi, H. 2003. Telaah Kualitas Air bagi Pengelolaan Sumber Daya dan
Lingkungan Perairan.Yogyakarta: Kanisius.
Fernandez, Borja. 2009. Tanpa Judul. (online),
(http://halamanputih.wordpress.com/tag/air-suling/, diakses 26 Juni 2012).
Ginting, Perdana. 2007. Sistem Pengelolaan Lingkungan dan Limbah Industri.
Bandung: YramaWidya.
Hidayat, Wahyu. 2008. Teknologi Pengolahan Air Limbah. (online),
(http://majarimagazine.com/2008/01/teknologi-pengolahan-air-limbah/,
diakses 07 Juli 2012).
Kristanto, Philip. 2002. Ekologi Industri. Yogyakarta: Penerbit Andi.
Metcalf and Eddy. 2004. Wastewater Engineering, 4th edition. New York
:McGraw Hill International Editions.
Nurhasanah. 2009. Penentuan Kadar COD (Chemical Oxygen Demand) pada
Limbah Cair Pabrik Kelapa Sawit, Pabrik Karet dan Domestik. (online),
(http://repository.usu.ac.id/bitstream/123456789/13930/1/09E02463.pdf,
diakses 12 April 2012)
Situmorang, M. 2007. Tekhnologi Penyediaan Air Bersih Edisi Kelima. Jakarta:
Kalma Media Pustaka.
Wardhana, Wisnu Arya. 1995. Dampak Pencemaran Lingkungan. Yogyakarta:
Andi Offset.
Widyabuningsih, Dewi. 2010. Pengelolaan Limbah Industri. Bandung: Politeknik
Negeri Bandung.

28
 

Anda mungkin juga menyukai