Anda di halaman 1dari 4

STORY OF

TROUBLE

CWP 2A TRIP
BUTTERFLY VALVE
TIDAK BISA CLOSE
6 JUNI 2020

8912518ID
DETAIL ACTION
1. Vibrasi CWP 2A HIGH
MOV OUTLET CONDENSER A 2. CWP 2A Triped
MOV OUTLET CONDENSER B 3. Change over mode operasi CCS
AC T I O N N O R M A L I TAT I O N

INLET KONDENSER A to Base, ketika flow feeder C dan F


INLET KONDENSER B di Kurangi mode Coal Flow Boiler
VACUUM KONDENSER B masih auto, sehinga ketika coal
TEMPERATUR INLET KONDENSER flow di kurangi mode auto boiler
memberikan perintah coal feeder
yg lain menuju setting awal
AMPERE CWP A

AMPERE CWP B
4. Setting mode boiler manual
PRESSURE OUTLET CWP A
stop coal mill C dan F coal flow
PRESSURE OUTLET CWP B
turun dari 183 T/H to 85 T/h,
VIBRASI CWP A
LOAD turun dari 296 Mw to 112 Mw
COAL FLOW
5. Close MOV outlet Condenser
LOAD MW
AMPERE VACUMP PUMP B
A&B
6. Close butterfly valve CWP 2A
TEMPERATURE CLOSE COOLING
dari kontaktor

CATATAN : CLOSE BUTTERFLY VALVE


- Waktu penanganan masalah 23menit MENGGUNAKAN KONTAKTOR :
terkendala perlu bantuan personel Instrumen
untuk menutup butterfly valve - pressure hydraulic normal diatas 10 Mpa
- Vacuum kondenser tertinggi 13,71 Kpa, - Ada 3 kontacktor berjejer dlm panel pintu bawah,
Temperatur close cooling tertinggi 44.6 degC dr kiri 1, 2, 3 Untuk close manual kalo dr tombol tidakbisa
yaitu colok kontaktor no 2(tengah) dan no 3 kanan
- Penyebab butterfly CWP tidak dapat Close disebabkan
karena tekanan hydrolic butterfly nol
TRENDING DATA