DAN
MENILAI DALAMNYA ANESTESIA
= REFLEKS LAKRIMASI :
TERJADI LAKRIMASI LEBIH DARI NORMAL PADA PLANE
1 & 2 STADIUM III
= REFLEKS MENELAN :
TERLIHAT SEBELUM PLANE 1, YAITU AWAL STA DIUM
III
= REFLEKS MUNTAH :
TERLIHAT PADA AKHIR STADIUM II (PADA WAK TU
RECOVERY REFLEKS INI TERLIHAT SAAT
PERALIHAN DARI STADIUM III KE STADIUM II)
= REFLEKS CARINA :
RANGSANGAN PADA CARINA OLEH PIPA ENDOTRAKEAL,
BRONKOSKOP, ATAU SUCTION-CATHETER, AKAN
MENYEBABKAN BATUK-BATUK PADA SEMUA
STADIUM SEBELUM STADIUM IV
= REFLEKS LARINGS :
RANGSANGAN PADA LARINGS DAN EPIGLOTIS AKAN MENGAKIBATKAN
BATUK-BATUK DAN ADDUKSI PITA SUARA (SPASME) REFLEKS INI
HILANG PADA AWAL STADIUM III PLANE 2
= TRACHEAL-TUG :
TERJADI PERGERAKAN YANG TAJAM DARI LARINGS DAN TRAKEA KEARAH
BAWAH REFLEKS INI TERLIHAT PADA STADIUM III PLANE 3
ATAU 4
APPARATUS DAN SIRKUIT
ANESTESIA :
SISTIM NON – REBREATHING :
UDARA EKSPIRASI TIDAK AKAN
BERCAMPUR DENGAN UDARA INSPIRASI
SEBAGAI CONTOH :
RUBEN VALVE (AMBU – HESSE VALVE)
KEUNTUNGAN ;
1. METODE INI NON - REBREATHING UDARA EKSPIRASI TIDAK
AKAN DI INSPIRASI LAGI
2. BILA INFLASI RESERVOIR - BAG TETAP , TIDAL - VOLUME DAPAT
DITENTUKAN TEPAT, MAKA FLOW (ALIRAN) GAS SAMA DENGAN
MINUTE - VOLUME PENDERITA BISA DIRUBAH DARI RESPIRASI
SPONTAN KE RESPIRASI KONTROL TANPA PENGATURAN VALVE
4. BISA DIGUNAKAN PADA KEADAAN - KEADAAN DI MANA
PEMAKAIAN CO2 ABSORPTION MERUPAKAN KONTRA INDIKASI
MISALNYA ANESTESIA DENGAN OBAT TRILENE
C2HCl3 + NaOH C2Cl2 + NaCl + H 2O
Trilene Soda-lime Dichloracetylene
(CO2 Absorpt) (Toksis utk n.cranialis)
KERUGIAN :
1. VALVE BISING DAN SUKA MENEMPEL / MELEKAT VALVE TIDAK
DAPAT DISTERILKAN DENGAN PEMANASAN
3. TANGAN PELAKSANA ANESTESIA HARUS DILATIH (DENGAN
PERASAAN YANG LAIN) UTK KONTROL RESPIRASI
4. PADA SAAT RESPIRASI SPONTAN, FLOW GAS HA RUS DIRUBAH
RUBAH OLEH KARENA MINUTE –VOLUME PENDERITA BERUBAH
UBAH
5. METODE INI BOROS
SISTIM REBREATHING (CLOSED - METHODE) :
= INI ADALAH METODE REBREATHING DENGAN
CO2 ABSORPTION
= SISTIM CLOSED MURNI HAMPIR TIDAK DIPAKAI
LAGI ; YANG SERING DIPAKAI SISTIM SEMI –
CLOSED, YAITU DENGAN MEMBUKA SEDIKIT VALVE
NYA ; HAL INI DISEBABKAN OLEH KARENA :
1. KONSENTRASI OBAT ANESTESIA VOLATILE SEPERTI
ETER, HALOTAN, BISA SANGAT MENINGKAT DALAM
SIRKUIT DAN BISA BERBAHAYA UNTUK PENDERITA
2. PERBANDINGAN N2O : O2 YANG DIBERIKAN
BISA MENGALAMI PERUBAHAN YANG BERARTI
DAN MUNGKIN BISA MEMBAHAYAKAN
3. BILA FUNGSI SODA- LIME KURANG BAIK, MAKA
CO2 DALAM SIRKUIT AKAN SANGAT MENINGKAT
= APPARATUS YANG TERGOLONG DALAM SISTIM INI ,
DAN SERING DIPAKAI ADALAH :
SISTIM CIRCLE :
A – VAPORIZER E – EXPIRATORY VALVE
B – VALVE F - CO2 ABSORPTION
C – CORRUGATED -TUBE G – REBREATHING – BAG
D – PENDERITA
KERUGIAN :
1. PIPA ATAU MASKER YANG TERLALU KETAT DAPAT
MENYEBABKAN TRAUMA PADA PENDERITA
2. DEBU ALKALI (SODA-LIME) BISA MASUK KE DALAM
RESPIRASI PENDERITA
3. PANAS YANG DIHASILKAN REAKSI KIMIAWI SODA –
LIME BISA MENYEBABKAN KERINGATAN PADA PENDERITA
4. TAHANAN RESPIRASI DAN DEAD-SPACE MENINGKAT
5. BILA ABSORPSI SODA-LIME KURANG BAIK, AKAN
TERJADI PENINGKATAN KADAR CO2 DALAM SIRKUIT
= CO2 ABSORPTION :
ANESTESIA BALANS
TEHNIK ANESTESIA DENGAN MEMBERIKAN BEBERAPA MACAM
OBAT DALAM JUMLAH / DOSIS KECIL, UNTUK MENCAPAI
TRIAS – ANESTESIA (HIPNOSIS , ANALGESIA , DAN RELAKSASI OTOT)