Appendix PDF
Appendix PDF
= 3999,140 kg/jam
3
FHCl = FHCl
1
= 2348,701 kg/jam
7
H2O : FH3 2O = 2348,701 kg/jam x
3
= 5480,303 kg/jam
FH2 2O = FH3 2O FH1 2O
= 5480,303 3999,140
= 1481,163 kg/jam
CaCO3(s)
CaCO3(s) MgCO3(s)
MgCO3(s) (5) R-01 (7) FeCl3(s)
FeCl3(s) HCl(aq)
MgCl2(s)
CaCl2(s)
H2O(l)
Untuk reaksi I :
X CaCO3 = 0,99 (William, dkk, 2002)
3183,854 kg
N CaCO3 = = 31,810 kmol
100,09kg/kmol
r1 = 99% . 31,810 = 31,492 kmol
Mis : F1HCl mula-mula = y1 * Mr HCl = B1HCl / XCaCO3 * Mr HCl
Untuk reaksi II :
X MgCO3 = 0,90 (Medjell, 1994)
30,583 kg
N MgCO3 = = 0,364 kmol
84kg/kmol
r2 = 90% . 0,364 = 0,328 kmol
Dari kedua reaksi di atas diperlukan total jumlah HCl mula- mula sebanyak :
1
FHCl 3
= FHCl = F1HCl mula-mula + F2HCl mula-mula
= (B1HCl / XCaCO3 * Mr HCl) + (B2HCl / XMgCO3 * Mr HCl)
= (62,984/ 0,99 * 36,5) + (0,655/ 0,9 * 36,5)
= 2322,137 + 26,564
= 2348,701 kg/jam
= 30,583 0,328 . 84
= 3,058 kg/jam
FeCl3 : 7
FFeCl 3
= FFeCl
5
3
= 4,829 kg/jam
CaCO3 : 7
FCaCO 3
= FCaCO
5
3
- . r1 . M r CaCO 3
= 31,492 . 44 + 0,328 . 44
= 31,492 . 110,99
= 3495,276 kg/jam
H2O : FH7 2 O = FH2O
3
+ r1 . M r H 2 O + r2 . M r H 2 O
Ca(OH)2(aq) 20%
CaCO3(s)
H2O(l) 80% MgCO3(s)
CaCO3(s) FeCl3(s)
MgCO3(s) (10) HCl(aq)
FeCl3(s) MgCl2(s)
HCl(aq) (7) (11) CaCl2(s)
MgCl2(s) R-02
H2O(l)
CaCl2(s) Ca(OH)2(s)
H2O(l) Mg(OH)2(s)
Fe(OH)3(s)
Gambar LA.4 Aliran Proses pada Reaktor Penetral
25,879 kg
N MgCl 2 = = 0,328 kmol
84 kg/kmol
r1 = 70% . 0,328 = 0,229 kmol
Mis : F1Ca(OH)2 mula-mula = y1 * Mr Ca(OH)2 = B1Ca(OH)2 / XMgCl2 * Mr Ca(OH)2
25,879 kg
N HCl = = 0,709 kmol
36,5 kg/kmol
r2 = 90% . 0,709 = 0,638 kmol
Mis : F2Ca(OH)2 mula-mula = y2 * Mr Ca(OH)2 = B2Ca(OH)2 / XHCl * Mr Ca(OH)2
4,829 kg
N FeCl3 = = 0,030 kmol
162,22 kg/kmol
r3 = 90% . 0,030 = 0,027 kmol
M: 0,020 y3 - -
B : 0,027 0,040 0,027 0,040
S: 0,002 y3 0,040 0,027 0,040
Dari ketiga reaksi di atas diperlukan total jumlah Ca(OH)2 mula- mula sebanyak :
8
FCa(OH) 2
10
= FCa(OH) 2
= F1Ca(OH)2 mula-mula + F2Ca(OH)2 mula-mula + F3Ca(OH)2 mula-mula
MgCO3 : 11
FMgCO 3
= FMgCO
7
3
= 3,058 kg/jam
MgCl2 :
11
FMgCl 2
= FMgCl
7
2
- . r1 . M r MgCl 2
= 0,229 . 58,320
= 13,377 kg/jam
Fe(OH)3 : 11
FFe(OH) 3
= r3 . M r Fe(OH) 3
= 0,027 . 106,87
= 2,863 kg/jam
H2O : FH112O = F 7 + F10 + r2 . M r H 2 O
MgCO3: 13
FMgCO 3
= FMgCO
11
3
= 3,058 kg/jam
FeCl3 : 13
FFeCl 3
= FFeCl
11
3
= 0,438 kg/jam
HCl : 13
FHCl = FHCl
11
= 2,588 kg/jam
CaCl2 : 13
FCaCl 2
= FCaCl
11
2
= 3560,606 kg/jam
Mg(OH)2 : 13
FMg(OH) 2
= FMg(OH)
11
2
= 13,377 kg/jam
Ca(OH)2 : 13
FCa(OH) 2
= FCa(OH)
11
2
= 10,242 kg/jam
MgCl2 : 13
FMgCl 2
= FMgCl
11
2
= 9,361 kg/jam
Fe(OH)3 : 13
FFe(OH) 3
= FFe(OH)
11
3
= 2,863 kg/jam
= 6280,493 5024,394
= 1256,099 kg/jam
Asumsi : Tahap kristalisasi memisahkan senyawa terlarut dan 56,4% air dari alur masuk
MgCO3: 15
FMgCO 3
= FMgCO
13
3
= 3,058 kg/jam
FeCl3 : 15
FFeCl 3
= FFeCl
13
3
= 0,438 kg/jam
HCl : 15
FHCl = FHCl
13
= 2,588 kg/jam
CaCl2 : 15
FCaCl 2
= FCaCl
13
2
= 3560,606 kg/jam
Mg(OH)2 : 15
FMg(OH) 2
= FMg(OH)
13
2
= 13,377 kg/jam
Ca(OH)2 : 15
FCa(OH) 2
= FCa(OH)
13
2
= 10,242 kg/jam
MgCl2 : 15
FMgCl 2
= FMgCl
13
2
= 9,361 kg/jam
Fe(OH)3 : 15
FFe(OH) 3
= FFe(OH)
13
3
= 2,863 kg/jam
= 56,4 % . 1256,099
= 708,025 kg/jam
FH152O = FH132O FH142O
= 1256,099 708,025
= 548,074 kg/jam
CaCO3(s) CaCO3(s)
MgCO3(s) MgCO3(s)
H2O (l)
FeCl3(s) FeCl3(s)
(16) HCl(aq)
HCl(aq)
MgCl2(s) (15) (17) MgCl2(s)
DE-01 CaCl2(s)
CaCl2(s)
H2O(l) H2O(l)
Ca(OH)2(s) Ca(OH)2(s)
Mg(OH)2(s) Mg(OH)2(s)
Fe(OH)3(s) Fe(OH)3(s)
MgCO3: 17
FMgCO 3
= FMgCO
15
3
= 3,058 kg/jam
FeCl3 : 17
FFeCl 3
= FFeCl
15
3
= 0,438 kg/jam
HCl : 17
FHCl = FHCl
15
= 2,588 kg/jam
CaCl2 : 17
FCaCl 2
= FCaCl
15
2
= 3560,606 kg/jam
Mg(OH)2 : 17
FMg(OH) 2
= FMg(OH)
15
2
= 13,377 kg/jam
Ca(OH)2 : 17
FCa(OH) 2
= FCa(OH)
15
2
= 10,242 kg/jam
MgCl2 : 17
FMgCl 2
= FMgCl
15
2
= 9,361 kg/jam
Fe(OH)3 : 17
FFe(OH) 3
= FFe(OH)
15
3
= 2,863 kg/jam
= 72 % . 548,074
= 394,613 kg/jam
FH172O = FH152O FH162O
= 548,074 394,613
= 153,461 kg/jam
CaCO3(s) CaCO3(s)
MgCO3(s) MgCO3(s)
FeCl3(s) FeCl3(s)
HCl(aq) HCl(aq)
MgCl2(s) (17) (18) MgCl2(s)
CaCl2(s)
RC-01 CaCl2(s)
H2O(l) H2O(l)
Ca(OH)2(s) Ca(OH)2(s)
Mg(OH)2(s) Mg(OH)2(s)
Fe(OH)3(s) Fe(OH)3(s)
FeCl3 : 18
FFeCl 3
= FFeCl
17
3
= 0,438 kg/jam
HCl : 18
FHCl = FHCl
17
= 2,588 kg/jam
CaCl2 : 18
FCaCl 2
= FCaCl
17
2
= 3560,606 kg/jam
Mg(OH)2 : 18
FMg(OH) 2
= FMg(OH)
17
2
= 13,377 kg/jam
Ca(OH)2 : 18
FCa(OH) 2
= FCa(OH)
17
2
= 10,242 kg/jam
MgCl2 : 18
FMgCl 2
= FMgCl
17
2
= 9,361 kg/jam
Fe(OH)3 : 18
FFe(OH) 3
= FFe(OH)
17
3
= 2,863 kg/jam
MgCO3: 21
FMgCO 3
= 0,99 FMgCO
18
3
= 3,028 kg/jam
19
FMgCO 3
= 0,01 FMgCO
18
3
= 0,031 kg/jam
FeCl3 : 21
FFeCl 3
= 0,99 FFeCl
18
3
= 0,478 kg/jam
19
FFeCl 3
= 0,01 FFeCl
18
3
= 0,005 kg/jam
HCl : 21
FHCl = 0,99 FHCl
18
= 2,562 kg/jam
CaCl2 : 21
FCaCl 2
= 0,99 FCaCl
18
2
= 3525,000 kg/jam
19
FCaCl 2
= 0,01 FCaCl
18
2
= 36,606 kg/jam
Mg(OH)2 : 21
FMg(OH) 2
= 0,99 FMg(OH)
18
2
= 13,243 kg/jam
19
FMg(OH) 2
= 0,01 FMg(OH)
18
2
= 0,134 kg/jam
Ca(OH)2 : 21
FCa(OH) 2
= 0,99 FCa(OH)
18
2
= 10,140 kg/jam
19
FCa(OH) 2
= 0,01 FCa(OH)
18
2
= 0,102 kg/jam
MgCl2 : 21
FMgCl 2
= 0,99 FMgCl
18
2
= 9,268 kg/jam
19
FMgCl 2
= 0,01 FMgCl
18
2
= 0,094 kg/jam
Fe(OH)3 : 21
FFe(OH) 3
= 0,99 FFe(OH)
18
3
= 2,835 kg/jam
19
FFe(OH) 3
= 0,01 FFe(OH)
18
3
= 0,029 kg/jam
CaCO3(s) CaCO3(s)
MgCO3(s) MgCO3(s)
FeCl3(s) FeCl3(s)
HCl(aq) HCl(aq)
MgCl2(s) (19) (20) MgCl2(s)
CaCl2(s) BM-01 CaCl2(s)
H2O(l) H2O(l)
Ca(OH)2(s) Ca(OH)2(s)
Mg(OH)2(s) Mg(OH)2(s)
Fe(OH)3(s) Fe(OH)3(s)
Gambar LA.10 Aliran Proses pada Ball Mill (BM-01)
MgCO3: 20
FMgCO 3
= FMgCO
19
3
= 0,031 kg/jam
FeCl3 : 20
FFeCl 3
= FFeCl
19
3
= 0,005 kg/jam
HCl : 20
FHCl = FHCl
19
= 0,026 kg/jam
CaCl2 : 20
FCaCl 2
= FCaCl
19
2
= 35,606 kg/jam
Mg(OH)2 : 20
FMg(OH) 2
= FMg(OH)
19
2
= 0,134 kg/jam
Ca(OH)2 : 20
FCa(OH) 2
= FCa(OH)
19
2
= 0,102 kg/jam
MgCl2 : 20
FMgCl 2
= FMgCl
19
2
= 0,094 kg/jam
Fe(OH)3 : 20
FFe(OH) 3
= FFe(OH)
19
3
= 0,029 kg/jam
Tabel LB.3 Kontribusi unsur atom urntuk estimasi kapasitas panas padatan
Komponen E (kJ/kmol.OC)
C 10,89
H 7,56
O 13,42
Fe 29,08
Cl 14,69
Sumber : Perry, 1999
T1
2 3 4
Untuk sistem yang melibatkan perubahan fasa persamaan yang digunakan adalah :
T2 Tb T2
CpdT = Cpl dT + H Vl + Cp v dT
T1 T1 Tb
(2)
H2O
28oC
Kondisi Masuk:
- Alur masuk = Alur 1 dan Alur 2
- Komponen masuk = HCl dan H2O
- Temperatur referensi= 25oC
- Temperatur alur 1 = 30oC
- Temperatur alur 2 = 28oC
Kalor yang masuk ke reaktor dapat dihitung dengan:
dQ
=n Cp dT
dT
Untuk HCl:
QHCl = (2348,701:36,5)x[29,13x10-3x(30-25) 0,1341x10-5/2x(302-252) + 0,9714x10-
8
/3x(303-253) 4,335x10-12](304-254)]
Untuk perhitungan H2O digunakan cara yang sama dengan perhitungan HCl.
Tabel LB.6 Panas alur 1 pada T = 30oC
n Cp dT H = n Cp dT
Komponen m (kg/jam)
(kmol/jam) (kJ/kmol) (kJ/jam)
HCl 2348.701 64.348 145.502 9362.758
H2O 3999.140 221.977 377.000 83685.379
Jumlah 93048,137
+ =
o
Dengan menggunakan trial error, diperoleh temperatur keluar sebesar 29,694 C
Saturated Steam
HCl 30% 99,6oC, 1 bar
H2O 70% (3) (6)
CO2
o o
29,694 C 32 C
CaCO3 CaCO3
MgCO3 (5) R-01 (7) MgCO3
FeCl3 32oC FeCl3
30oC HCl
MgCl2
Kondensat CaCl2
99,6oC, 1 bar H2O
= 107,992 kJ/kmol
Kondisi Masuk
- Alur masuk = Alur 3 dan Alur 5
- Komponen masuk = CaCO3, MgCO3, FeCl3, HCl, H2O
- Temperatur referensi= 25oC
- Temperatur alur 3 = 29,694oC
- Temperatur alur 4 = 30oC
Pada Tabel LB.8 diketahui bahwa panas alur 3 adalah 116458,118 kJ/jam
Kondisi Keluar
- Alur keluar = Alur 6 dan Alur 7
- Komponen keluar = CaCO3, MgCO3, FeCl3, HCl, H2O, MgCl2, CaCl2, CO2
- Temperatur referensi= 25oC
- Temperatur alur 6 = 32oC
- Temperatur alur 7 = 32oC
Sebagai media pemanas, dibutuhkan saturated steam yang masuk pada 1 bar dan 99,6oC.
Kondensat keluar pada suhu 99,6oC dan tekanan 1 bar. Jumlah steam yang dibutuhkan,
dimana adalah 2257,9 kJ/kg:
dQ / dT
m =
72244,002 kJ/jam
m = = 32,756 kg/jam
2257,9 kJ/kg
Kondisi Masuk:
- Alur masuk = Alur 1 dan Alur 2
- Komponen masuk = Ca(OH)2 dan H2O
- Temperatur referensi= 25oC
- Temperatur alur 8 = 30oC
- Temperatur alur 9 = 28oC
n Cp dT H = n Cp dT
Komponen m (kg/jam)
(kmol/jam) (kJ/kmol) (kJ/jam)
Ca(OH)2 53,858 1,224 447,500 547,760
Jumlah 547,760
Kondisi Keluar:
- Alur keluar = Alur 10
- Komponen keluar = Ca(OH)2 dan H2O
- Temperatur referensi= 25oC
Diketahui H pelarutan Ca(OH)2 adalah 16,2 kJ/kmol
+ () =
o
Dengan menggunakan trial error,diperoleh temperatur keluar sebesar 26,012 C.
Kondisi Masuk
- Alur masuk = Alur 7 dan Alur 10
- Komponen masuk = CaCO3, MgCO3, FeCl3, HCl, H2O, MgCl2, CaCl2
- Temperatur referensi= 25oC
- Temperatur alur 7 = 32oC
- Temperatur alur 10 = 26,012oC
Pada Tabel LB.11 diketahui bahwa panas alur 7 adalah 191546,251 kJ/jam
Pada Tabel LB.14 diketahui bahwa panas alur 10 adalah 1023,577 kJ/jam
Kondisi Keluar
- Alur keluar = Alur 11
dQ/dT = 188204,025-191546,251-1023,577+(-99,161*0,229)+(-50,019*0,638)-(-
279,742*0,027)
= -4428,462 kJ/jam
Superheated Steam
150oC H2O
CaCO3 1 bar CaCO3
(12) 115oC
MgCO3 MgCO3
FeCl3 (11) FeCl3
(13)
HCl o FE-01 HCl
MgCl2 32 C MgCl2
CaCl2 115oC CaCl2
H2O H2O
Ca(OH)2 Ca(OH)2
Saturated Steam
Mg(OH)2 Mg(OH)2
99,6oC
Fe(OH)3 Fe(OH)3
1 bar
Kondisi Masuk
- Alur masuk = Alur 11
- Komponen masuk = CaCO3, MgCO3, FeCl3, HCl, H2O, MgCl2, CaCl2, Ca(OH)2,
Mg(OH)2, Fe(OH)3
- Temperatur referensi = 25oC
- Temperatur alur 11 = 32oC
Pada Tabel LB.15 diketahui panas pada alur 11 pada 32oC adalah 188204,025 kJ/jam
Kondisi Keluar
- Alur keluar = Alur 12 dan 13
- Komponen keluar = CaCO3, MgCO3, FeCl3, HCl, H2O, MgCl2, CaCl2, Ca(OH)2,
Mg(OH)2, Fe(OH)3
- Temperatur referensi= 25oC
- Temperatur alur 12 = 115oC
- Temperatur alur 13 = 115oC
m n Cp dT H = n Cp dT
Komponen
(kg/jam) (kmol/jam) (kJ/kmol) (kJ/jam)
CaCO3 31,839 0,318 7659,450 2436,499
MgCO3 3,058 0,036 1521,000 55,372
FeCl3 0,483 0,003 6583,500 19,602
HCl 2,588 0,071 2617,937 185,622
MgCl2 9,361 0,098 6615,540 650,300
CaCl2 3560,606 32,080 1545,318 49574,453
H2O 1256,099 69,721 6786,000 473128,764
Ca(OH)2 10,242 0,138 8055,000 1113,351
Mg(OH)2 13,377 0,229 1638,000 375,712
Fe(OH)3 2,863 0,027 8281,800 221,866
Jumlah 527761,541
Kondisi Masuk
- Alur masuk = Alur 13
- Komponen masuk = CaCO3, MgCO3, FeCl3, HCl, H2O, MgCl2, CaCl2, Ca(OH)2,
Mg(OH)2, Fe(OH)3
- Temperatur referensi = 25oC
- Temperatur alur 13 = 115oC
Pada Tabel LB.17 diketahui panas pada alur 13 pada 115oC adalah 527761,541 kJ/jam
Kondisi Keluar
- Alur keluar = Alur 14 dan 15
- Komponen keluar = CaCO3, MgCO3, FeCl3, HCl, H2O, MgCl2, CaCl2, Ca(OH)2,
Mg(OH)2, Fe(OH)3 , H2O
- Temperatur referensi= 25oC
- Temperatur alur 14 = 40oC
- Temperatur alur 15 = 40oC
m n Cp dT H = n Cp dT -Hs*n
Komponen
(kg/jam) (kmol/jam) (kJ/kmol) (kJ/jam)
CaCO3 31,839 0,318 1257,278 399,945
MgCO3 3,058 0,036 253,500 9,229
FeCl3 0,483 0,003 1097,250 3,267 94,385
HCl 2,588 0,071 436,451 30,946 -5303,627
MgCl2 9,361 0,098 1093,703 107,510 853,444
CaCl2 3560,606 32,080 255,382 8192,754 -2659466,956
H2O 548,073 30,421 1131,000 34406,670
Ca(OH)2 10,242 0,138 1342,500 185,559 -2239,142
Mg(OH)2 13,377 0,229 273,000 62,619
Fe(OH)3 2,863 0,027 1380,300 36,978
Jumlah 43435,475 -2666061,896
Data operasi:
a) Udara
Tin = 50C
Tout = 300C
Hin = 0,01 kg H2O/kg udara (asumsi)
b) Cairan Terlarut
Laju Alir = 4890,516 kg/jam
Tin = 1150C
Tout = 400C
Neraca Bahan
GHin + LsXin = GHout + LsXout
Dimana :
G = Laju alir udara, kg/jam udara kering
Ls = Laju alir zat padat, kg/jam
H = Kelembaban udara, massa uap per satuan massa udara kering
X = Kandungan kebasahan-bebas, massa air per satuan massa zat total
Neraca Panas
GH inG + L s H ins = GH out
G + Ls H s
out
+Q
Superheated Steam
150oC H2O (g)
CaCO3 (16)
1 bar o CaCO3
MgCO3 (15) 110 C (17)
o MgCO3
FeCl3 40 C
DE-01 FeCl3
HCl 110oC HCl
MgCl2 MgCl2
CaCl2 CaCl2
H2O H2O
Ca(OH)2 Saturated Steam Ca(OH)2
Mg(OH)2 99,6oC Mg(OH)2
Fe(OH)3 1 bar Fe(OH)3
Kondisi Masuk
- Alur masuk = Alur 15
- Komponen masuk = CaCO3, MgCO3, FeCl3, HCl, H2O, MgCl2, CaCl2, Ca(OH)2,
Mg(OH)2, Fe(OH)3
- Temperatur referensi = 25oC
- Temperatur alur 15 = 40oC
Pada Tabel LB.19 diketahui panas pada alur 15 pada 40oC adalah 43435,475 kJ/jam
Kondisi Keluar
- Alur keluar = Alur 16 dan 17
- Komponen keluar = CaCO3, MgCO3, FeCl3, HCl, H2O, MgCl2, CaCl2, Ca(OH)2,
Mg(OH)2, Fe(OH)3 , H2O
- Temperatur referensi= 25oC
- Temperatur alur 16 = 110oC
- Temperatur alur 17 = 110oC
Sebagai media pemanas, dibutuhkan superheated steam yang masuk pada 1 bar
dan 1500C. Saturated steam keluar pada suhu 99,6oC dan tekanan 1 bar. Jumlah steam
yang dibutuhkan, dimana CpdT steam = 3,47.10-3+1,45.10-6T+0,121-8T3 adalah :
dQ / dT
m =
CpdT
Kondisi Masuk
- Alur masuk = Alur 17
- Komponen masuk = CaCO3, MgCO3, FeCl3, HCl, H2O, MgCl2, CaCl2, Ca(OH)2,
Mg(OH)2, Fe(OH)
- Temperatur referensi = 25oC
- Temperatur alur 17 = 110oC
Pada Tabel LB.21 diketahui panas pada alur 17 pada 110oC adalah 106161,179 kJ/jam
Kondisi Keluar
- Alur keluar = Alur 18
- Komponen keluar = CaCO3, MgCO3, FeCl3, HCl, H2O, MgCl2, CaCl2, Ca(OH)2,
Mg(OH)2, Fe(OH)
- Temperatur referensi= 25oC
- Temperatur alur 18 = 30oC
Neraca Panas
GH inG + L s H ins = GH out
G + Ls H s
out
+Q
Asumsi : tidak ada air yang menguap selama pendinginan dengan udara, sehingga Xin =
Xout = 0,04 dan Hin = Hout = 0,01 kg H2O/kg udara (Pisecky, 1990)
a) Entalpi Cairan Terlarut
Hs = CpS(Ts-To)+XCpA(Ts-To)
(6) (22)
CO2 (g) JC-01 CO2 (l)
o o
T1 = 32 C T2 = 35 C
P1 = 1 atm P2 = 15 atm
Kondisi Masuk
- Alur masuk = Alur 6
- Komponen masuk = CO2
- Temperatur referensi = 25oC
- Temperatur alur 6 = 32oC
Pada Tabel LB.10 diketahui panas pada alur 6 pada 32oC adalah 8321,727 kJ/jam
Kondisi Keluar
- Alur keluar = Alur 22
- Komponen keluar = CO2
- Temperatur referensi= 25oC
- Temperatur alur 22 = 35oC
Tabel LB.23 Panas alur 22 pada T = 35oC
n Cp dT H = n Cp
Komponen m (kg/jam)
(kmol/jam) (kJ/kmol) dT (kJ/jam)
CO2 1402,622 31,878 373,539 11907,586
Jumlah 11907,586
= 57946,779 karung
Perhitungan :
a. Ukuran Tangki
Volume larutan (Vl) = (6347,841/ 1062,785) x 15 x 24
= 2150,222 m3
Faktor kelonggaran = 20 %
Volume tangki = V1 x 1,2
= 2150,222 x 1,2
= 2580,266 m3
Perbandingan tinggi tangki dengan diameter tangki (Hs : D) = 1 : 1
Volume Silinder = /4 x D2Hs = /4 x D3
Tutup tangki berbentuk ellipsoidal dengan rasio axis major terhadap minor 2 : 1,
sehingga: tinggi head (Hh) = 1/6 x D (Brownel & Young, 1959)
= 11,208 m = 441,265 in
Tinggi silinder (Hs) =D = 11,208 m
b. Tekanan design
Tinggi bahan dalam tangki (Hc) = (Vl/Vt) x HT
= (2150,222/2580,266) x 13,076
= 10,897 m
Phidrostatik = x g x Hc
= 1062,785 x 9,8 x 10,897
= 113493,146 Pa
= 113,493kPa
Po = Tekanan Operasi = 1 atm = 101,325 kPa
Faktor kelonggaran = 100%
Pdesign = (1+1) x (Phidrosatik + Po)
= 2 x (214,818)
= 429,636 kPa = 4,240 atm = 61,499 psi
Perhitungan:
a. Perencanaan Pompa
Untuk aliran turbulen (Nre >2100), (Peters & Timmerhaus, 1991)
Di,opt = 0,363 Q0,45 0,13
Untuk aliran laminar ,
Di,opt = 0,133 Q0,4 0,2 (Peters & Timmerhaus, 1991)
dengan : Di,opt = diameter optimum (m) = densitas (kg/m3)
Q = laju volumetrik (m3/s) = viskositas (cP)
d. Menentukan Friksi, F
F = (4 . f . V2. L)/(2. gc. D)
= (4 . 0,005 . 1,6275 2. 72,808)/(2 . 32,174 .0,134)
= 0,4468 ft.lbf/lbm
Perhitungan pompa air bersih analog dengan perhitungan pompa tangki penampungan
HCl (P-01) :
Spesifikasi:
Di,opt = 0,363 Q0,45 0,13 = 1,1164 in (Peters & Timmerhaus, 1991)
Pipa (Geankoplis, 2003) :
Ukuran pipa nominal = 1,5 in
Schedule pipa = 40
V = 1,1757 ft/s
NRe = 16484,04645
L1 = 50 ft
L2 = 1,7442 ft
L3 = 8,05 ft
L4 = 4,2933 ft
L5 = 8,7208 ft
L = 72,8083 ft
f = 0,005 (Geankoplis, 2003)
F = 0,3268 ft.lbf/lbm
z = 10 m
P =0
-Ws = 33,1364 ft.lbf/lbm
Wp = 0,0626 hp
Daya aktual = 0,0782 hp
Digunakan pompa daya pompa standar 0,25 hp
Vt = Vs + Vh
= +
=
= 5,896 m = 232,141 in
Tinggi silinder (Hs) =D = 5,896 m
Tinggi tutup ellipsoidal (Hh) = 1/6 x D
= 0,983 m
Tinggi tangki (HT) = Hs + (2 x Hh)
= 5,896 + (2 x 0,983)
= 7,862 m
c. Tekanan Design
Tinggi bahan dalam tangki = (Vl/Vt) x HT
= (178,896/214,675) x 7,862
= 6,552 m
Phidrostatik = x g x Hc
= 1050,309 x 9,8 x 6,552
= 67434,972 Pa = 67,435 kPa
Po = Tekanan Operasi = 1 atm = 101,325 kPa
Faktor kelonggaran = 20%
Pdesign = (1+0,2) x (Phidrosatik + Po)
= 1,2 x (67,435 + 101,325)
= 202,512 kPa = 1,999 atm = 28,988 psia
f. Pengaduk (impeller)
Jenis : flat six blade open turbine (turbin datar enam daun)
Dari figure 3.4-4 (Geankoplis, 2003) dengan menggunakan kurva 2, untuk pengaduk
jenis flat six blade open turbine dengan 4 baffle, diperoleh Np = 3,5
Maka,
=
= , , ,
= 107820,578 Watt = 144,590 HP
Effisiensi motor penggerak = 80%
,
() = = ,
,
Digunakan daya 200 hp
Perhitungan:
a. Waktu Tinggal () Reaktor
XA = 0,99
,
= = ,
,
CA = CAO (CAO x XA)
= 7,447 (7,447 x 0,99)
= 0,0368 M
Asam klorida membutuhkan waktu 3 jam bereaksi dengan kalsium klorida untuk
berubah menjadi kalsium klorida apabila kondisi operasi pada reaktor tercapai (William,
dkk, 2002)
= 3 jam
b. Ukuran Reaktor
V = . campuran
= 3 jam . 8639 liter/jam
= 25917,953 liter = 25,918 m3
Volume larutan (VL) = 25,918 m3
Faktor kelonggaran = 20%
= 3,097 m = 121,922 in
Tinggi silinder (Hs) =D = 3,097 m
Tinggi tutup ellipsoidal (Hh) = 1/6 x D
= 0,516 m
Tinggi tangki (HT) = Hs + (2 x Hh)
= 3,097 + (2 x 0,516)
= 4,129 m
c. Tekanan Desain
Tinggi bahan dalam tangki = (Vl/VR) x HT
= (25,923 /31,107) x 4,129
f. Pengaduk (impeller)
Jenis : flat six blade open turbine (turbin datar enam daun)
Kecepatan putaran (N) : 60 rpm = 1 rps
Efisiensi motor : 80% (Peters & Timmerhaus, 1991)
Pengaduk didesain dengan standar berikut:
Da : Dt =1:3 (Geankoplis, 2003)
W : Da =1:5 (Geankoplis, 2003)
C : Dt =1:3 (Geankoplis, 2003)
4 Baffle : Dt / J = 12 (Geankoplis, 2003)
dimana : Da = diameter pengaduk
Dt = diameter tangki
W = lebar daun pengaduk
C = jarak pengaduk dari dasar tangki
Jadi:
Diameter pengaduk (Da) : 1/3 x Dt = 1/3 x 3,097 = 1,032 m
Lebar daun pengaduk (W) : 1/8 x Da = 1/8 x 1,032 = 0,129 m
Dari figure 3.4-4 (Geankoplis, 2003) dengan menggunakan kurva 2, untuk pengaduk
jenis flat six blade open turbine dengan 4 baffle, diperoleh Np = 3,5
Maka,
=
= , , ,
= 5247,081 Watt = 7,035 HP
Effisiensi motor penggerak = 80%
,
() = = ,
,
Digunakan daya 10 hp
g. Jaket Pemanas
Dari neraca panas, jumlah steam pemanas yang diperlukan = 5,576 kg/jam
Volume spesifik steam pada suhu 99,6oC adalah 0,695 m3/kg
,
= = , /
,
Perhitungan pompa (P-03) analog dengan perhitungan pompa tangki penampungan HCl
(P-01):
Spesifikasi:
De = 3 Q0,36 0,18 = 2,596 in (Peters & Timmerhaus, 1991)
Pipa (Geankoplis, 2003):
Ukuran pipa nominal = 3 in
Schedule pipa = 40
Diameter dalam (ID) = 3,068 in = 0,2557 ft = 0,0788 m
Diameter luar (OD) = 3,5 in = 0,2917 ft = 0,09 m
Luas penampang dalam (Ai) = 0,0513 ft2
V = 1,4779 ft/s
NRe = 25770,28095
L1 = 50 ft
L2 = 3,3237 ft
L3 = 15,34 ft
L4 = 8,1813 ft
L5 = 16,618 ft
L = 93,463 ft
f = 0,005 (Geankoplis, 2003)
F = 0,2482 ft.lbf/lbm
z = 10 m
P =0
-Ws = 33,0582 ft.lbf/lbm
Wp = 0,355 hp
Daya aktual = 0,4438 hp
Digunakan pompa daya pompa standar 0,5 hp
= 969,444 karung
Perhitungan:
a. Waktu Tinggal () Reaktor
XA = 0,9
0,9
= 0,09122 .
0,021
= 3,909 jam
b. Ukuran Reaktor
V = . campuran
= 3,909 jam . 276 liter/jam
= 1080,123 liter = 1,080 m3
Volume larutan (VL) = 1,080 m3
Faktor kelonggaran = 20%
Volume reaktor (VR) = ( 1 + 0,2 ). VL
= 1,2 (1,080)
= 1,296 m3
= 1,074 m = 3,523 in
Tinggi silinder (Hs) =D = 1,074 m
Tinggi tutup ellipsoidal (Hh) = 1/6 x D
= 0,179 m
Tinggi tangki (HT) = Hs + (2 x Hh)
= 1,296 + (2 x 0,179)
= 1,432 m
c. Tekanan Desain
Tinggi bahan dalam tangki (Hc) = (Vl/Vt) x HT
= (1,080/1,296) x 1,432
= 1,193 m
Phidrostatik = x g x Hc
= 1244,283 x 9,8 x 1,193
= 14547,154 Pa = 14,547 kPa
Po = Tekanan Operasi = 1 atm = 101,325 kPa
Faktor kelonggaran = 20%
Pdesign = (1+0,2) x (Phidrosatik + Po)
f. Pengaduk (impeller)
Jenis : flat six blade open turbine (turbin datar enam daun)
Kecepatan putaran (N) : 60 rpm = 1 rps
Efisiensi motor : 80% (Peters & Timmerhaus, 1991)
Pengaduk didesain dengan standar berikut:
Da : Dt =1:3 (Geankoplis, 2003)
W : Da =1:5 (Geankoplis, 2003)
C : Dt =1:3 (Geankoplis, 2003)
4 Baffle : Dt / J = 12 (Geankoplis, 2003)
dimana : Da = diameter pengaduk
Dt = diameter tangki
W = lebar daun pengaduk
C = jarak pengaduk dari dasar tangki
Jadi:
Diameter pengaduk (Da) : 1/3 x Dt = 1/3 x 1,074 = 0,358 m
Lebar daun pengaduk (W) : 1/5 x Da = 1/8 x 0,959 = 0,045 m
Tinggi pengaduk dari dasar (C) : 1/3 x Dt = 1/3 x 1,074 = 0,358 m
Lebar baffle (J) : 1/12 x Dt = 1/12 x 1,074 = 0,089 m
Daya untuk pengaduk :
() =
, ,
=
, /
Perhitungan pompa (P-04) analog dengan perhitungan pompa tangki penampungan HCl
(P-01) :
Spesifikasi:
Di,opt = 3 Q0,36 0,18 = 2,6233 in (Peters & Timmerhaus, 1991)
Pipa (Geankoplis, 2003):
Ukuran pipa nominal = 3 in
Schedule pipa = 40
Diameter dalam (ID) = 3,068 in = 0,2557 ft = 0,0788 m
Diameter luar (OD) = 3,5 in = 0,2917 ft = 0,09 m
Fluida panas :
Laju alir steam masuk = 4524,614 kg/jam = 9975,0544 lbm/jam
Temperatur awal (T1) = 133,5 C = 272,3F
Temperatur akhir (T2) = 133,5 C = 272,3F
Fluida dingin :
Laju alir cairan masuk = 9914,910 kg/jam = 21858,6089 lbm/jam
Perhitungan:
(1) t = beda suhu sebenarnya
Fluida Panas Fluida dingin Selisih
T1 = 272,3F Temperatur yang lebih tinggi t1 = 89,6F t1 = 182,7F
T2 = 272,3F Temperatur yang lebih rendah t2 = 239F t2 = 33,3F
T1 T2 = 0F Selisih t2t1 = 149,4F t2t1 = 149,4F
+ , + ,
= = =
(2) Tc dan tc
T 1 +T 2 272,3 + 272,3
Tc = = = 272,3o F
2 2
t 1 +t 2 89,6 + 239
tc = = = 164,3o F
2 2
b. Dari Tabel 9, hal 842, Kern, 1965, nilai yang terdekat adalah 54 tube dengan ID
shell 15 in.
c. Koreksi UD
= "
= ,
= 353,268 ft2
Q 11684847.86
UD = = = 306,263 ft 2
A t 353,268 108
N t a 't 54 1,04
at = = = 0,098 ft 2 (Kern, 1695)
144 n 144 4
(4) Kecepatan massa
W
Gt = (Kern, 1695)
at
9975,054 lb m
Gt = = 102308,250
0,098 jam ft 2
(5) Bilangan Reynold
Pada Tc = 272,3F, = 0,015 cP = 0,0351 lbm/ft2jam
Dari Tabel 10, Kern (1965), untuk 1 in OD, 18 BWG, diperoleh:
ID = 1,15 in = 0,0958 ft
ID G t
Re t = (Kern, 1695)
0,0958 102308,250
Re t = = 279515.198
0,0351
hio = 1500 Btu/jam.ft2oF
15,25 0,3125 9
as = = 0,191 ft 2
144 1,5625
(4) Kecepatan massa
9975,054
= = = . (, )
, .
Pressure drop
Fluida panas: steam, tube side
(1) specific volume steam pada Tc = 272,3 oF adalah 7,044 ft3/lb
, = = ,
, ,
Untuk Ret = 271960,707
f = 0,00008 ft2/in2 (Kern, 1695)
s = 1
L 20
(2) N + 1 = 12 = 12 = 26,667 (Kern, 1695)
B 9
Ds = 15,25/12 = 1,2708
1 f G t Ds (N + 1)
2
Pt = (Kern, 1695)
2 5,22 1010 ID s s
Pressure drop
f Gs L n
2
Ps =
(0,00038)(76445,420 ) (20)(1)
2
Perhitungan pompa (P-05) analog dengan perhitungan pompa tangki penampungan HCl
(P-01) :
Spesifikasi:
Di,opt = 3 Q0,36 0,18 = 1,9308 in (Peters & Timmerhaus, 1991)
liquid/crystal
channel
liquid/crystal
space
Hc
Dn
Hn
Hs
Hs
2,085
= (1,389 + 0,233)
2,503
= 1,359 m
Phidrostatik = x g x Hf
= 2005,586 x 9,8 x 1,359
= 26709,448 Pa = 26,709 kPa
Po = Tekanan Operasi = 1 atm = 101,325 kPa
Faktor kelonggaran = 20%
Pdesign = (1+0,2) x (Phidrosatik + Po)
= 1,2 x (26,709 + 101,325)
= 153,641 kPa = 21,992 psia
v. Tebal Dinding Silinder
A = 1 / 4 D 2
1/ 2
4 x 0,856m 2
1/ 2
4 xA
D= = = 1,044 m = 3,424 ft
3,14
Diameter rotary dryer biasanya antara 0,25-2 m (hal.12-56, Perry, 1999), sehingga
desain diameter terpenuhi.
= 1 / 4(3,14)(1,044) 2 x (10,437)
= 8,930 m3
Hold-up = 0,1x 8,930 m3 = 0,893 m3
hold up
Time of passage() =
feed rate
0,893 x1871,721
= = 0,400 jam = 23,976 menit
4182,491
7,875
23,976 = 3195,6098
S
0,253
23,976 + 3195,6098 = , S1 = 0,0001415
S1
0,253
23,976 3195,6098 = , S2 = 0,00001437
S1
Slope dari rotary cooler biasanya antara 0-8 (Perry,1999), sehingga nilai slope
terpenuhi.
f. Menghitung Daya
Total daya penggerak untuk rotary cooler antara 0,5 D2 sampai 1,0 D2 (hal.12-56,
Perry, 1999),untuk desain alat diambil 0,5 D2
Daya (P) = 0,5D2 = 0,5(3,424)2 = 11,725 hp
Digunakan daya 12 hp
A = 1 / 4 D 2
1/ 2
4 x 2,676m 2
1/ 2
4 xA
D= = = 1,846 m = 6,056ft
3,14
Diameter rotary cooler biasanya antara 0,2-2 m (hal.12-56, Perry, 1999), sehingga
desain diameter terpenuhi.
= 1 / 4(3,14)(1,846) 2 x (7,384 )
= 19,761 m3
Hold-up = 0,1 19,761 m3 = 1,976 m3
0,305
64,440 43562,832 = , S2 = 0,00000700
S1
Slope dari rotary cooler biasanya antara 0-8 (hal.12-56, Perry,1999), sehingga
nilai slope terpenuhi.
f. Menghitung daya
Total daya penggerak untuk rotary cooler antara 0,5 D2 sampai 1,0 D2 (Perry,
1999),untuk desain alat diambil 0,5 D2.
Daya (P) = 0,5D2 = 0,5(6,056)2 = 18,338 hp
Digunakan daya 19 hp
Perhitungan:
Umpan masuk : 3787,878 kg/jam
Fraksi terayak : 0,9
=
, =
,
Padatan yang lolos = 3787,878 (0,9) = 3409,090 kg/jam
Ukuran ayakan ditaksir dari table A.5-3 Tyler Standart Screen Scale, Geankoplis, 1997.
Maka dipakai ayakan dengan spesifikasi:
Ukuran = 80 mesh
Bukaan ayakan = 0,175 mm
Nominal diameter kawat = 0,142 mm
Dpi = 0,317 mm
Perhitungan:
Umpan masuk : 378,787 kg/jam = 0,105 kg/s
Diameter partikel produk, Dp : 0,3 mm
Total daya penggerak untuk ball mill:
, , ,
= = = , = ,
,
Daya standar yang digunakan 10 hp
= 31818,175 karung
k p 2
( k 1) / kN st
4
Pad = 2,78 10 N st mvl p1 1 (Peters & Timmerhaus, 1991)
k - 1 p1
Data:
Laju alir massa = 1402,622 kg/jam = 51,537 lb/menit
campuran = 719,6 kg/m3
1402,622 kg / jam
mvl = 3
= 1,9492 m3/jam = 0,0005 m3/detik
719,6 kg / m
1,4 1519,875
(1, 4 1) / 1, 43
4
Pad = 2,78 10 3 1,9492 101,325 1
1,4 - 1 101,325
= 0,1696 hp
Perhitungan :
a. Ukuran Tangki
Volume larutan (Vl) = 1402,622 / 719,6) x 15 x 24
= 701,701 m3
Faktor kelonggaran = 20 %
Volume tangki = V1 x 1,2
= 701,701 x 1,2 = 842,041 m3
Perbandingan tinggi tangki dengan diameter tangki (Hs : D) = 1 : 1
Volume Silinder = /4 x D2Hs = /4 x D3
Tutup tangki berbentuk ellipsoidal dengan rasio axis major terhadap minor 2 : 1,
sehingga: tinggi head (Hh) = 1/6 x D (Brownel & Young, 1959)
= 9,722 m = 382,765 in
Jari jari (R) = 4,861 m = 191,384 in
Tinggi silinder (Hs) =D = 9,722 m
Tinggi tutup ellipsoidal (Hh) = 1/6 x D
= 1/6 x 9,722 m = 1,62 m
Tinggi total tangki (HT) = Hs + Hh = 11,343 m
b. Tekanan design
Tinggi bahan dalam tangki (Hc) = (Vl/Vt) x HT
= (701,701 /842,041) x 11,343
= 9,452 m
Phidrostatik = x g x Hc
= 719,6 x 9,8 x 9,452
= 66657,407 Pa = 66,657 kPa
Po = Tekanan Operasi = 15 atm = 1519,875 kPa
Faktor kelonggaran = 20%
Pdesign = (1+0,2) x (Phidrosatik + Po)
= 1,2 x (66,657 + 101,325)
= 1903,839 kPa = 18,789 atm = 272,518 psi
20 mm
2m
20 mm
Desain pompa
Di,opt = 0,363 (Q)0,45()0,13 (Peters & Timmerhaus, 1991)
= 0,363 (0,0009 m3/s)0,45 (996,24 kg/m3)0,13
= 0,0371 m = 1,4617 in
= 0,0131 ft.lbf/lbm
v2 (1,2999 ) 2
1 elbow 90: hf = n.Kf. = 1(0,75) = 0,0197 ft.lbf/lbm
2.g c 2(32,174)
v2 (1,2999 ) 2
1 check valve: hf = n.Kf. = 1(2) = 0,0525 ft.lbf/lbm
2.g c 2(32,174)
= 0,0263 ft.lbf/lbm
dimana : v1 = v2
P1 = P2
Z = 50 ft
32,174ft / s 2
maka : 0 + (50 ft ) + 0 + 0,2031 ft.lbf / lbm + Ws = 0
32,174ft.lbm / lbf .s 2
Ws = 50,2031 ft.lbf/lbm
Untuk efisiensi pompa 80 %, maka:
Ws = - Wp
50,2031 = 0,8 Wp
Wp = 62,7538 ft.lbf/lbm
Daya pompa : P = m Wp
3075,9398 1 hp
= lbm / s 62,7538 ft.lbf / lbm
(0,45359)(3600) 550ft.lbf / s
= 0,2149 hp
Maka dipilih pompa dengan daya motor 0,25 hp.
h
Desain panjang ideal bak : L = K v (Kawamura, 1991)
0
dengan : K = faktor keamanan = 1,5
h = kedalaman air efektif (9-16 ft); diambil 9 ft.
Maka : L = 1,5 (9/1,57) 0,2593 = 2,2292 ft
Diambil panjang bak = 2,5 ft = 0,7620 m
Uji desain
Va pl t
Waktu retensi (t) : t = =
Q laju volumetrik
2,5 1 9 ft 3
= = 9,643 menit
2,333 ft 3 / min
Desain diterima, dimana t diizinkan 6-15 menit. (Kawamura, 1991)
Q laju volumetrik
Surface loading: =
A luas permukaan masukan air
Kondisi operasi :
- Temperatur = 28C
- Densitas air () = 996,24 kg/m3 = 62,1396 lbm/ft3 (Geankoplis, 2003)
- Viskositas air () = 0,8360 cP = 0,0006 lbm/fts (Geankoplis, 2003)
Laju alir massa (F) = 3075,9398 kg/jam = 1,8837 lbm/detik
Desain Tangki
a. Ukuran Tangki
0,1975 kg/jam 24 jam/hari 30 hari
Volume larutan, Vl = = 0,3477 m3
0,3 1363 kg/m3
Volume tangki, Vt = 1,2 0,3477 m3 = 0,4172 m3
Direncanakan perbandingan diameter dengan tinggi tangki, D : H = 2 : 3
1
V= D 2 H
4
1 3
0,4172 m3 = D 2 D
4 2
3
0,4172 m3 = D3
8
Maka: D = 0,7076 m; H = 1,0615 m
0,3477
Tinggi cairan dalam tangki = 1,0615 = 0,8845 m
0,4172
c. Daya pengaduk
Jenis pengaduk : flat 6 blade turbin impeller
Jumlah baffle : 4 buah
Untuk turbin standar (McCabe, 1999), diperoleh:
Da/Dt = 1/3 ; Da = 1/3 0,7076 m = 0,2359 m = 0,7739 ft
E/Da = 1 ; E = 0,2359 m = 0,7739 ft
L/Da = 1/4 ; L = 1/4 0,2359 m = 0,0590 m = 0,1935 ft
W/Da = 1/5 ;W = 1/5 0,2359 m = 0,0472 m = 0,1548 ft
J/Dt = 1/12 ; J = 1/12 0,7076 m = 0,0590 m = 0,1935 ft
dengan :
Dt = diameter tangki
Da = diameter impeller
E = tinggi turbin dari dasar tangki
L = panjang blade pada turbin
W = lebar blade pada turbin
J = lebar baffle
N (D a )2
N Re = (Geankoplis, 2003)
P= (McCabe, 1999)
gc
KT = 6,3 (McCabe, 1999)
6,3 (1 put/det)3 (0,7739ft)5 (85,0898 lbm/ft3 ) 1 hp
P= 2
32,174 lbm.ft/lbf.det 550 ft lbf/det
= 0,0084 hp
Efisiensi motor penggerak = 80 %
0,0084
Daya motor penggerak = = 0,0105 hp
0,8
Dipilih daya motor standar 0,05 hp.
Friction loss:
1 Sharp edge entrance: hc = 0,00000010 ft.lbf/lbm
2 elbow 90: hf = 0,00000029 ft.lbf/lbm
1 check valve: hf = 0,00000039 ft.lbf/lbm
Pipa lurus 30 ft: Ff = 0,000006 ft.lbf/lbm
1 Sharp edge exit: hex = 0,00000020 ft.lbf/lbm
Total friction loss: F = 0,000007 ft.lbf/lbm
dimana : v1 = v2
P1 = 2484,3029 lbf/ft
P2 = 2727,9837 lbf/ft
P
= 2,9009 ft.lbf/lbm
Z = 30 ft
maka: Ws = 32,909 ft.lbf/lbm
Wp = 41,1261 ft.lbf/lbm
Daya pompa: P = 0,0000090 hp
Maka dipilih pompa dengan daya motor 1/20 hp.
Perhitungan spesifikasi Tangki pelarutan Soda Abu (Na2CO3) (TP-02) analog dengan
perhitungan spesifikasi Tangki pelarutan Alum [Al2(SO4)3] (TP-01)
a. Ukuran tangki
Volume larutan, Vl = 0,1929 m3
Volume tangki, Vt = 0,2314 m3
D = 0,5814 m ; H = 0,8721 m
b. Tebal dinding tangki
Tinggi cairan dalam tangki = 0,7268 m = 2,3844 ft
Tekanan hidrostatik, Phid = 9,4513kPa
Poperasi = 110,8914 kPa
Pdesain = 116,3151 kPa
Tebal shell tangki:
t = 0,0005 m = 0,0191 in
Maka tebal shell yang dibutuhkan = 0,0191 in + 0,125 in = 0,1441 in
Tebal shell standar yang digunakan = in (Brownell & Young,1959)
Friction loss:
1 Sharp edge entrance: hc = 0,00000003 ft.lbf/lbm
2 elbow 90: hf = 0,0000001 ft.lbf/lbm
1 check valve: hf = 0,0000001 ft.lbf/lbm
Pipa lurus 30 ft: Ff = 0,0000019 ft.lbf/lbm
1 Sharp edge exit: hex = 0,000000060cft.lbf/lbm
Total friction loss: F = 0,0000022 ft.lbf/lbm
dimana : v1 = v2
P1 = 2316,0285 lbf/ft; P2 = 2727,9837 lbf/ft
=
(3075,9398 )
= 996,3014 kg/m3
3075,9398 0,1975 0,1066
+ +
996,24 2710 2533
3075,9398 kg / jam 1 jam
Volume cairan, V = = 3,0877 m3
996,2878
V = D2H
1/ 2
4V 4 3,0877
D = ( )1 / 2 = = 1,1450 m
H 3,14 3
Maka, diameter clarifier = 1,1450 m
Tinggi clarifier = 1,5 D =1,7176 m
Kondisi operasi:
Temperatur = 28C
Tekanan = 1 atm
Laju massa air = 3075,9398 kg/jam
Densitas air = 996,24 kg/m3 = 62,1935 lbm/ft3(Geankoplis, 2003)
Kondisi operasi:
- Temperatur = 28C
- Densitas air () = 996,24 kg/m3 = 62,1396 lbm/ft3 (Geankoplis, 2003)
- Viskositas air () = 0,8360 cP = 0,0006 lbm/fts (Geankoplis, 2003)
Laju alir massa (F) = 3075,9398 kg/jam = 1,8837 lbm/detik
Debit air/laju alir volumetrik = 0,0303 ft3/s = 0,0009 m3/s
Di,opt = 0,0371 m = 1,4617 in
Dari buku Geankoplis App A.5, dipilih pipa commercial steel :
- Ukuran nominal : 2 in
- Schedule number : 40
- Diameter Dalam (ID) : 2,067 in = 0,1723 ft = 0,0525 m
- Diameter Luar (OD) : 2,375 in = 0,1979 ft
- Luas penampang dalam (At) : 0,0233 ft2
Kecepatan linier : v = 1,2999 ft/s
Bilangan Reynold : NRe = 24788,918
dimana : v1 = v2
P1 = 2933,5743 lbf/ft
P2 = 2768,4871 lbf/ft
P
= -2,6225 ft.lbf/lbm
Z = 30 ft
maka: Ws = 27,8074 ft.lbf/lbm
Wp = 34,7593 ft.lbf/lbm
Daya pompa: P = 0,1529 hp
Maka dipilih pompa dengan daya motor 0,25 hp.
Desain Tangki
a. Volume tangki
3075,9398 kg/jam 4 jam
Volume air, Va = 3
= 12,3502 m3
996,24 kg/m
Volume tangki, Vt = 1,2 12,3502 m3 = 14,8202 m3
b. Diameter tangki
Direncanakan perbandingan diameter dengan tinggi silinder, D : H = 2 : 3
1 2
V= D H
4
1 3
14,8202 m3 = D 2 D
4 2
3
14,8202 m3 = D3
8
Maka, D = 2,326 m
H = 3,4892 m
c. Tebal tangki
12,3502 m3
Tinggi air dalam tangki = 3,4892 m = 2,9076 m
14,8202 m3
Tekanan hidrostatik: P = gh
= 996,24 kg/m3 9,8 m/det2 2,9076 m
= 28,3878 kPa
Tekanan operasi = 1 atm = 101,325 kPa
P = 28,3878 kPa + 101,325 kPa = 129,7128 kPa
Faktor kelonggaran = 5%
Friction loss:
1 Sharp edge entrance: hc = 0,0301 ft.lbf/lbm
3 elbow 90: hf = 0,1356 ft.lbf/lbm
1 check valve: hf = 0,1205 ft.lbf/lbm
Pipa lurus 20 ft: Ff = 0,2758 ft.lbf/lbm
1 Sharp edge exit: hex = 0,0603 ft.lbf/lbm
Total friction loss: F = 0,6223 ft.lbf/lbm
dimana : v1 = v2
P1 = 2768,4871 lbf/ft
P2 = 2903,447 lbf/ft
P
= 2,2962 ft.lbf/lbm
Z = 20 ft
maka: Ws = 22,9186 ft.lbf/lbm
Wp = 28,6482 ft.lbf/lbm
Daya pompa: P = 0,0383 hp
Maka dipilih pompa dengan daya motor 0,05 hp.
dimana : v1 = v2
P1 = 2768,4871 lbf/ft
P2 = 3067,9966 lbf/ft
P
= 4,9420 ft.lbf/lbm
Z = 40 ft
maka: Ws = 45,7958 ft.lbf/lbm
Wp = 57,2448 ft.lbf/lbm
Daya pompa: P = 0,1081 hp
Maka dipilih pompa dengan daya motor 0,25 hp.
Friction loss:
1 Sharp edge entrance: hc = 0,0007 ft.lbf/lbm
3 elbow 90: hf = 0,0030 ft.lbf/lbm
1 check valve: hf = 0,0027 ft.lbf/lbm
Pipa lurus 20 ft: Ff = 0,0062 ft.lbf/lbm
1 Sharp edge exit: hex = 0,0013 ft.lbf/lbm
Total friction loss: F = 0,0139 ft.lbf/lbm
dimana : v1 = v2
Friction loss:
1 Sharp edge entrance: hc = 0,0007 ft.lbf/lbm
3 elbow 90: hf = 0,0030 ft.lbf/lbm
1 check valve: hf = 0,0027 ft.lbf/lbm
Pipa lurus 20 ft: Ff = 0,0062 ft.lbf/lbm
1 Sharp edge exit: hex = 0,0013 ft.lbf/lbm
Total friction loss: F = 0,0139 ft.lbf/lbm
dimana : v1 = v2
P1 = P2 = 2271,6084 lbf/ft2
Z = 20 ft
maka: Ws = 20,014 ft.lbf/lbm
Wp = 25,0174 ft.lbf/lbm
Daya pompa: P = 0,005 hp
Maka dipilih pompa dengan daya motor 0,05 hp.
Friction loss:
1 Sharp edge entrance: hc = 0,0007 ft.lbf/lbm
3 elbow 90: hf = 0,0030 ft.lbf/lbm
1 check valve: hf = 0,0027 ft.lbf/lbm
Pipa lurus 20 ft: Ff = 0,0062 ft.lbf/lbm
1 Sharp edge exit: hex = 0,0013 ft.lbf/lbm
Total friction loss: F = 0,0139 ft.lbf/lbm
a. Ukuran tangki
Volume larutan, Vl = 0,0083 m3
Volume tangki, Vt = 0,01 m3
D = 0,2039 m ; H = 0,3058 m
Friction loss:
1 Sharp edge entrance: hc = 6,79.10-11 ft.lbf/lbm
3 elbow 90: hf = 1,528.10-10 ft.lbf/lbm
1 check valve: hf = 1,358.10-10 ft.lbf/lbm
Pipa lurus 30 ft: Ff = 2,363.10-9 ft.lbf/lbm
1 Sharp edge exit: hex = 1,358.10-10 ft.lbf/lbm
Total friction loss: F = 2,855.10-9 ft.lbf/lbm
dimana : v1 = v2
P1 = 2182,5825 lbf/ft
P2 = 2903,447 lbf/ft
P
= 9,0779 ft.lbf/lbm
Z = 20 ft
maka: Ws = 29,0779 ft.lbf/lbm
Wp = 36,3474 ft.lbf/lbm
Daya pompa: P = 0,000000139 hp
Maka dipilih pompa dengan daya motor 0,05 hp.
Desain tangki
a. Volume tangki
1200 kg/jam 24 jam
Volume air, Va = = 28,9087 m3
996,24 kg/m 3
Volume tangki, Vt = 1,2 28,9087 m3 = 34,6904 m3
c. Tebal tangki
Tekanan hidrostatik: Ph = gh
= 996,24 kg/m3 9,8 m/det2 3,8606 m
= 37,692 kPa
Tekanan operasi = 1 atm = 101,325 kPa
P = 37,692 kPa + 101,325 kPa = 139,017 kPa
Faktor kelonggaran = 5 %
Maka, Pdesign = (1,05) (139,017 kPa) = 145,9679 kPa
Joint efficiency = 0,8 (Brownell & Young, 1959)
Allowable stress = 12650 psia = 87218,714 kP (Brownell & Young, 1959)
Tebal shell tangki:
PD
t=
2SE 1,2P
(145,9679 kPa) (3,0885 m)
=
2 (87218,714 kPa) (0,8) 1,2 (145,9679 kPa)
= 0,0032 m = 0,1273 in
Faktor korosi = 0,125 in
Maka tebal shell yang dibutuhkan = 0,1273 in + 0,125 in = 0,2523 in
Tebal shell standar yang digunakan = 0,5 in (Brownell & Young, 1959)
dimana : v1 = v2
P1 = P2 = 2116,2281 lbf/ft
Z = 30 ft
maka: Ws = 30,898 ft.lbf/lbm
Wp = 38,623 ft.lbf/lbm
Daya pompa: P = 0,05 hp
Maka dipilih pompa dengan daya motor 0,25 hp.
Desain tangki
a. Volume tangki
1696,597 kg/jam 24 jam
Volume air, Va = 3
= 40,872 m3
996,24 kg/m
Volume tangki, Vt = 1,2 40,872 m3 = 49,0464 m3
Tebal shell standar yang digunakan = 0,5 in (Brownell & Young, 1959)
dimana : v1 = v2
P1 = P2 = 3067,9966 lbf/ft
Z = 20 ft
maka: Ws = 20,4398 ft.lbf/lbm
Wp = 25,5497 ft.lbf/lbm
Daya pompa: P = 0,0483 hp
Maka dipilih pompa dengan daya motor 0,05 hp.
Kondisi operasi :
Temperatur = 90C
Tekanan = 1 atm
Laju massa air = 179,343 kg/jam
Densitas air = 965,321 kg/m3 (Perry, 1999)
Kebutuhan perancangan = 1 jam
Faktor keamanan = 20%
Friction loss:
1 Sharp edge entrance: hc = 0,0007 ft.lbf/lbm
3 elbow 90: hf = 0,0030 ft.lbf/lbm
1 check valve: hf = 0,0027 ft.lbf/lbm
Pipa lurus 20 ft: Ff = 0,0062 ft.lbf/lbm
1 Sharp edge exit: hex = 0,0013 ft.lbf/lbm
Total friction loss: F = 0,0139 ft.lbf/lbm
dimana : v1 = v2
P1 = 2258,064 lbf/ft
P2 = 2116,2281 lbf/ft
P
= -2,3533 ft.lbf/lbm
Z = 40 ft
maka: Ws = 37,6648 ft.lbf/lbm
Wp = 47,081 ft.lbf/lbm
Daya pompa: P = 0,0094 hp
Maka dipilih pompa dengan daya motor 0,25 hp.
Dalam rencana pra rancangan pabrik Kalsium Klorida digunakan asumsi sebagai
berikut:
Pabrik beroperasi selama 330 hari dalam setahun.
Kapasitas maksimum adalah 30.000 ton/tahun.
Perhitungan didasarkan pada harga peralatan tiba di pabrik atau purchased-equipment
delivered (Peters et.al., 2004).
Harga alat disesuaikan dengan nilai tukar dolar terhadap rupiah adalah :
US$ 1 = Rp 8.685,- (Analisa, 29 April 2011).
r=
[n X i Yi X i Yi ] (Montgomery, 1992)
(n X i 2 (X i )2 ) (n Yi 2 (Yi )2 )
Dengan memasukkan harga harga pada Tabel LE-2, maka diperoleh harga koefisien
korelasi :
r = (14) . (28307996) (27937)(14184)
[(14). (55748511) (27937)] [(14)(14436786) (14184) ]
= 0,98 1
Harga koefisien yang mendekati +1 menyatakan bahwa terdapat hubungan linier
antar variabel X dan Y, sehingga persamaan regresi yang mendekati adalah persamaan
regresi linier.
105
Jan,2002
P-82
103 2
10-1 1 10 10 103
Capacity, m3
Gambar LE.1 Harga Peralatan untuk Tangki Penyimpanan (Storage) dan Tangki
Pelarutan (Peters et.al., 2004)
Indeks harga tahun 2011 (Ix) adalah 1.274,099. Maka estimasi harga tangki untuk (X2)
529,644 m3 adalah :
0 , 49
794,452 1.274,099
Cx = US$ 6.700
1 1.103
Cx = US$ 204.050 (Rp 8.685,-)/(US$ 1)
Cx = Rp 1.772.170.559 ,-/unit
Dengan cara yang sama diperoleh perkiraan harga alat lainnya yang dapat dilihat
pada Tabel LE.3 untuk perkiraan peralatan proses dan Tabel LE.4 untuk perkiraan
peralatan utilitas.
Untuk harga alat non impor sampai di lokasi pabrik ditambahkan biaya sebagai berikut :
- PPn = 10 % (Rusjdi, 2004)
- PPh = 10 % (Rusjdi, 2004)
- Transportasi lokal = 0,5 %
- Biaya tak terduga = 0,5 %
- Total = 21 %
Total harga peralatan tiba di lokasi pabrik (purchased equipment delivered) adalah :
= 1,43 (Rp 30.831.566.464,- + Rp 19.641.739.779,-) + 1,21
(Rp 239.821.324,- + Rp 331.935.195,-)
= Rp 72.868.653.616,-
7. Refrigerant (R-717)
Kebutuhan = 83260,5817 k/jam
Harga amonia untuk industri = Rp. 17.000,-/liter (ICIS Pricing, 2011)
Harga total = 90 hari 24 jam/hari 83260,5817 ltr/jam Rp 17.000,-/liter
= Rp 459.061.710.965,-
Total biaya persediaan bahan baku proses dan utilitas selama 3 bulan (90 hari) adalah
Rp 466.870.542.845,-
Penjualan :
1. Harga jual kalsium klorida (CaCl2) = US$ 4,8675/kg (ICIS Pricing, 2011)
Kelompok Masa
Tarif (%) Beberapa Jenis Harta
Harta Berwujud (tahun)
I. Bukan Bangunan
1.Kelompok 1 4 25 Mesin kantor, perlengkapan, alat
perangkat / tools industri
2. Kelompok 2 8 12,5 Mobil, truk kerja
3. Kelompok 3 16 6,25 Mesin industri kimia, mesin industri
mesin
II. Bangunan
Permanen 20 5 Bangunan sarana dan penunjang
(Sumber: Rusdji, 2004)
2. Perawatan bangunan
Diperkirakan 8% dari harga bangunan (Peters et.al., 2004).
Biaya perawatan bangunan = 0,08 Rp 22.649.500.000,-
= Rp 1.811.960.000,-
3. Perawatan kendaraan
Diperkirakan 8% dari harga kendaraan (Peters et.al., 2004).
Biaya perawatan kendaraan = 0,08 Rp 5.970.000.000,-
= Rp 477.600.000,-
5. Perawatan perpipaan
Diperkirakan 10 % dari harga perpipaan (Peters et.al., 2004).
Biaya perawatan perpipaan = 0,1 Rp 43.721.191.989,-
= Rp 4.372.119.199,-
7. Perawatan insulasi
Diperkirakan 8% dari harga insulasi (Peters et.al., 2004).
Biaya perawatan insulasi = 0,08 Rp 8.744.238.398,-
= Rp 699.539.072,-
Total biaya persediaan bahan baku proses dan utilitas selama 1 tahun adalah :
330
= Rp 509.404.023.612,- = Rp 1.867.814.753.246,-
90
Pengurangan bonus atas penghasilan bruto sesuai dengan UU RI No. 17/00 Pasal 6 ayat
1 sehingga :
Laba sebelum pajak (bruto) = Rp 373.022.089.300,-
Rp 373.022.089.300,-
PM = 100 %
Rp 2.541,734.873.354,-
PM = 14,68 %
Rp 181.351.218.493,-
BEP = 100 %
Rp 2.541,734.873.354,- Rp 1.985.487.082.700 -
BEP = 32,60 %
Kapasitas produksi pada titik BEP = 32,60 % 30.000 ton/tahun
= 9.780,7787 ton/tahun
Nilai penjualan pada titik BEP = 33,53 % Rp 2.541.734.873.354,-
= Rp 828.671.545.514,-
Rp 279.766.566.975,-
ROI = 100 %
Rp 1.481.535.032.026,-
ROI = 18,88 %
Rp 279.766.566.975,-
RON = 100 %
Rp 702.183.503.896,-
RON = 39,84 %
52.367.766.460 -33.544.728.915
. . .
= % + ( % %)
( . . . ( . . . )
= , %
Gambar E.1 Grafik Break Even Point (BEP) Pabrik Kalsium Klorida dari Batu Kapur dan Asam Klorida