Anda di halaman 1dari 65

1

BOOK 1
MODULE 1A
BOILER BASICS
2
TUJ UAN I NSTRUKSI ONAL UMUM
TUJ UAN I NSTRUKSI ONAL KHUSUS
SETELAH SELESAI TRAINING INI, DIHARAPKAN PARA TRAINEE MAMPU
MENJELASKAN DENGAN BENAR :
TAHAP PROSES PEROBAHAN ENERGI DALAM STEAM CYCLE POWER
PRINSP- 2 KERJA BERBAGAI TYPE BOILER , MENJELASKAN NAMA DAN FUNGSI MASING-2
BAGIAN BOILER
MENGENAL KONSTRUKSI DAN FUNGSI DARI SEMUA EQUIPMENT YANG TERPASANG
MENGETAHUHI PRINSIP-2 CARA MENGOPERASIKAN BOILER DENGAN BENAR DENGAN
DIDASARI PENGERTIAN PROSES APA YANG TERJADI SETIAP OPERATOR MELAKUKAN
PERINTAH PEROBAHAN PADA MAIN CONTROL ROOM
MAMPU MENGANALISA SEBAB DAN AKIBAT YANG AKAN TERJADI SETIAP TERJADI
PEROBAHAN UNJUK KERJA
SETELAH SELESAI TRAINING INI, DIHARAPKAN PARA PESERTA TRAINING
MAMPU MENJELASKAN DENGAN BENAR :
JENIS dan FUNGSI KOMPONEN UTAMA DARI SUATU POWER PLANT
PRINSIP 2 PENGOPERASIAN BOILER DENGAN OUT PUT DAYA YANG OPTIMAL DAN
EFFISIENSI YANG MAKSIMAL ( ASPEK PENGOPERASIAN MENUNJANG PRODUKSI )
CARA MENEKAN SERENDAH MUNGKIN OUTAGE dan MENJAGA KEHANDALAN / OUTPUT
( ENDURANCE ) SETINGGI MUNGKIN ( ASPEK PEMELIHARAAN MENUNJANG BEAYA OPERASI
SERENDAH MUNGKIN )
BOILER BASICS
3
STEAM GENERATOR
/ BOILER / KETTEL
SATURATED
STEAM
STEAM
TURBINE
SUPERHEATED
STEAM
POWER
GENERATOR
INDUSTRIAL
PROCESS
UTILITY
PROSES KONVERSI ENERGI :
FUEL (CHEMICAL ENERGY )
+ WATER
STEAM ( KINETICAL ENERGY )
TURBINE ( MECHANICAL ENERGY )
ELECTRICAL ENERGY
STEAM CYCLE POWER
BOILER BASICS
SUTET
KONDENSOR
TANK
FEEDING PUMP
CONDENSATING PUMP
4
FUEL FIRING SYSTEMS PADA UTILITY BOILER TYPE ( PAITON )
BOILER BASICS
HP. SUPERHEATER
to St.TURBINE
REHEATER
EKONOMIZER
BURNER
FEED WATER
ST. DRUM
WATER DRUM
BURNER
ECON
BURNER
SPHT
DOWN COMER
BOILER BANK
WATER DRUM
St. DRUM
To St. TURBINE
COLLECTOR /
HEADER
COAL FIRED STEAM
GENERATOR UTILITY
OIL FIRED STEAM
GENERATOR MARINE /
INDUSTRIAL
HEADER
LP. SUPERHEATER
from St.TURBINE
5
PROSES PEROBAHAN ENERGY
CHEMICAL ENERGY
( BAHAN BAKAR )
CALORIFIC ENERGY
( GAS PANAS )
HEAT & KINETIC ENERGY
( STEAM )
MECHANICAL ENERGY
( TURBIN BERPUTAR )
ELECTRIC ENERGY
SATURATED STEAM ENERGY
( STEAM )
TERBAKAR
FURNACE
BOILER
STEAM
EKSPANSI
TURBINE
GENERATOR
BOILER
PROCESS
2. ENGINEERING FUNDAMENTALS
BOILER BASICS
6
PROSES PEROBAHAN
AIR MENJ ADI UAP
P
O

2. ENGINEERING FUNDAMENTALS
b
1

b
2

a - b = TEKANAN POMPA PENGISIAN
b - b
1
= KENAIKAN TEMP. SAMPAI TITIK DIDIH ( water saturated ) PADA TEKANAN ( P
1
)
b
1
- b
X
= % AIR MENDIDIH DALAM BENTUK CAIR
b
X
- b
2
= % AIR MENDIDIH DALAM BENTUK STEAM
b
2
- c = STEAM ( saturated ) TERUS DIPANASKAN , BEROBAH MENJADI SUPERHEATED
STEAM.
c - c
1
= STEAM BEREXPANSI DIDALAM TURBINE
c
1
- d = STEAM KELUAR DARI TURBINE dan MASUK KEDALAM KONDENSOR
d - a = PROSES KONDENSASI
b
X

c
1

P
1

P
2

DAERAH
STEAM + STEAM
( KONDENSOR )
Daerah cair / steam
( campuran )
P
1

BOILER BASICS
SETIAP PENURUNAN TEMP. SPHT 28
0
C KE TURBINE
AKAN MENURUNKAN EFISIENSI SIKLUS. 1%
7
6. PERCOBAAN DI ULANG KEMBALI DENGAN AIR 1 ( SATU ) KILOGRAM, TETAPI TEKANAN DINAIKKAN
MENJADI ( P2 ). SEMUA FASE FISIK TSB AKAN TERJADI BERULANG. TETAPI TERJADI PADA TEMPERATUR
YANG LEBIH TINGGI
7. TITIK-2 DIMANA AIR MULAI MENGUAP, DINAMAKAN GARIS BATAS BAWAH.
TITIK-2 DIMANA AIR BEROBAH MENJADI UAP JENUH, DINAMAKAN GARIS ( X ).
TITIK-2 DIMANA UAP JENUH BEROBAH MENJADI UAP KERING, DINAMAKAN GARIS BATAS ATAS.
8. BILA PANAS TERUS DIBERIKAN KEPADA AIR, SIFAT UAP BEROBAH MENJADI UAP PANAS LANJUT (
SUPERHEATED STEAM ). SIFAT-2 DAN HUKUM FISIK BERLAKU SEPERTI HUKUM GAS SEMPURNA
9. - GARIS ( a ) DINAMAKAN GARIS BATAS BAWAH. YAITU TITIK DIMANA AIR MULAI BEROBAH MENJA -
DI STEAM
- GARIS 1-2-3-4-5 DINAMAKAN ISOBAR ( GARIS YANG MENGHUBUNGKAN TITIK-2 DENGAN TEKANAN
YANG SAMA )
- GARIS ( X ) ATAU (C) DINAMAKAN GARIS KONDISI STEAM. MIS. (X = 65 ), BERARTI SEMUA TITIK
SEPANJANG GARIS TSB. MEMPUNYAI KANDUNGAN STEAM 65% DAN AIR 35 %
- GARIS (C) DINAMAKAN GARIS BATAS ATAS. BERARTI SEMUA TITIK SEPANJANG GARIS TSB.
BESARNYA X = 100. BERARTI BILA TEMP. DITURUNKAN, STEAM MULAI BERKONDENSASI.
BILA TEMP. DINAIKKAN, STEAM MULAI BEROBAH MENJADI SUPERHEATED.
- GARIS (d) TEMPAT KEDUDUKAN TITIK YANG MENGANDUNG KALOR YANG SAMA. DINAMAKAN
GARIS ISOTHROPIS
KESI MPULAN
1. AIR AKAN MENDIDIH PADA TEMPERATUR YANG LEBIH TINGGI BILA TEKANAN DINAIKKAN
2. MAKIN TINGGI TEKANAN DAN MAKIN TINGGI TEMPERATURE, STEAM AKAN MENGANDUNG
JUMLAH KALORI YANG LEBIH BESAR PULA.. KANDUNGAN KALOR / PANAS PADA SEPANJANG
GARIS ( d ) YANG SAMA MENGANDUNG JUMLAH PANAS YANG SAMA PULA.
3. TITIK K ( = KRITIS ) ADALAH KEADAAN DIMANA FLUIDA ( AIR / STEAM ) MEMPUNYAI SIFAT FISIK
YANG SAMA.
WATER TO STEAM CONVERSION ( LANJUTAN )
BOILER BASICS
8
SENSIBLE HEAT
PANAS YANG DIPERLUKAN
UNTUK MENAIKKAN
TEMPERATURE . MIS. DARI AIR
SAMPAI AIR MENDIDIH
PROSES TERJADI SEPANJANG
GARIS BATAS BAWAH ( GARIS
WATER SATURATED )
DIAGRAM MOLLIERS [ pada boiler conventional ]
X=30%
X=30% 30% STEAM + 70% WATER
P
P = PRESSURE
LATENT HEAT
PANAS YANG DIPERLUKAN UNTUK
MEROBAH KEADAAN AIR STEAM
PADA TEMPERATURE KONSTAN.
PROSES BERLANGSUNG DI
DAERAH CAMPURAN ( WATER -
STEAM )
BOILER BASICS
9
BASIC DIAGRAM of BOILER
CAMPURAN
UDARA &
FUEL
HEAT
TRANSFER
SURFACE
STEAM - WATER SYSTEM
WATER
FUEL
AIR
FURNACE
STEAM
BLOWDOWN
FLUE GAS
ASH
Hydrogen ( H2)
Carbon ( C)
Sulphur ( S)
Nitrogen ( N2 )
Oxygen ( O2 )
Water ( H2O)
FUEL FLUE GAS
Carbon Monoxida (CO)
Carbon Dioxida ( CO2 )
Oxygen ( O2 )
Nitrogen (N2)
Nitrous oxides (NOX )
Sulphur Oxides ( SOX )
Hydropgen ( H2 )
Aldehydes
Uap Air.
Nitrogen ( N2 )
Oxygen ( O2 )
Water ( H2O)
Ash Mineral
Carbon
Etc
Boiler
Air
ASH
Boiler
2. ENGINEERING FUNDAMENTALS BOILER BASICS
10
ENERGY BALANCE - HEAT BALANCE
RADIASI [ 2.5% ]
TOTAL BTU ( TERMASUK KINETIC
ENERGY )
FLUE GAS ( POTENTIAL ENERGY
UNBURN CHEMICAL LATENT
HEATS SENSIBLE HEAT
STEAM
FLUE GAS
- POTENTIAL ENERGY
- KINETIC ENERGY
- UNBURNED CHEMICAL
- LATENT HEAT
- SENSIBLE HEAT
BLOWDOWN
- SENSIBLE HEAT
- LATEN T HEAT
ASH
- SOOTBLOWING STEAM
- SENSIBLE HEAT IN ASH
- UNBURNED CARBON IN ASH
FUEL
- ( GRINDING POWER )
- CHEMICAL ENERGY
- SENSIBLE HEAT -
LATENT HEAT
- POTENTIAL ENERGY
- KINETIC ENERGY
- ATOMIZING AIR ( POTENTIAL & KINETIC
ENERGY )
- ATOMIZING STEAM ( TOTAL ENERGY )
COMBUSTION AIR
- SENSIBLE HEAT
- LATENT HEAT -
POTENTIAL ENERGY
- KENETIC ENERGY ( FAN
POWER )
FEEDWATER
- TOTAL BTU
- KINETIC ENERGY
- POTENTIAL ENERGY
( PUMP POWER )
2. ENGINEERING FUNDAMENTALS BOILER BASICS
11
SIKLUS RANKINE ( WATER - STEAM CYCLE )

SEMUA KEADAAN WATER / STEAM DALAM BERBAGAI
KONDISI YANG BERBEDA DIPETAKAN DALAM
DIAGRAM MOLLIER ATAU T - s ( TEMPERATURE -
ENTHROPI) DIAGRAM ATAU DIAGRAM h-s
( ENTHALPY - ENTROPY )
DAERAH DISEBELAH KIRI GARIS BATAS BAWAH ( a )
DINAMAKAN DAERAH CAIR.
@ DAERAH YANG DIBATASI GARIS BATAS BAWAH dan
GARIS BATAS ATAS DINAMAKAN DAERAH CAMPURAN.
@ DAERAH SEBELAH KANAN GARIS BATAS ATAS ( c )
DINAMAKAN DAERAH PANAS LANJUT ( SUPER -
HEATED ).
DARI DIAGRAM MOLLIER, SEMUA DATA DIROBAH
MENJADI ANGKA-2, DISUSUN MENJADI DAFTAR UAP
( STEAM TABLE ) BERFUNGSI BILA KITA AKAN
MENGHITUNG DAYA BOILER ATAU TURBIN UAP.
1
2
3
4
Qin
1
2
3
4
1
2
1

1 - 2 = KENAIKAN TEMP. KARENA KERJA POMPA ( FW PUMP)
2 - 2
1
= KENAIKAN TEMP. KARENA PEMBAKARAN ( Q in )
2
1
- 3 = PROSES SATURATED STEAM MENJADI SUPERHEATED
STEAM
3 - 4 = TEMP. STEAM TURUN KARENA EXPANSI DIDALAM
TURBIN
4 - 1 = PROSES KONDENSASI DIDALAM KONDENSOR
X = 85% = STEAM 85 % + WATER 15 %
DAERAH
CAMPURAN
WATER + STEAM
TITIK KRITIS
X
BOILER BASICS
12
I NTRODUCTI ON TO BOI LER
BOILER TYPE
BOILER CAPACITY
BOILER EFFCIENCY
ANGKA PERBANDINGAN JUMLAH TENAGA THERMAL YANG
BERMANFAAT ( BERGUNA , BISA DIJUAL ) DENGAN SELURUH
TENAGA THERMAL YANG DIBERIKAN KE BOILER TSB ( HARGA BH.
BAKAR, TENAGA LISTRIK DARI LUAR / PLN, HARGA FEEDWATER,
HARGA AIR PENDINGIN KONDENSOR, DLL YANG DIPEROLEH DARI
LUAR BOILER )
BESARNYA ( BERATNYA ) STEAM MAXIMAL YANG MAMPU DIHASILKAN OLEH BOILER
TSB DALAM TIAP JAM. MIS. BOILER CAPACITY 150 TPH.
BERDASARKAN TUJUAN PENGGUNAAN ( UTILITY, INDUSTRIAL, KOMBINASI UTILITY - INDUSTRIAL
TOPPING SYSTEM DAN BOTTOMING SYSTEM )
BERDASARKAN KONSTRUKSINYA ( PACKAGE BOILER DAN NON PACKAGE BOILER )
BERDASARKAN SUMBER KALORI YANG DIGUNAKAN ( KONVENSIONAL, HEAT RECOVERY,
KOMBINASI KEDUANYA dan NUCLEAR )
BERDASARKAN JENIS BH. BAKAR YANG DIGUNAKAN : PADAT ( BT. BARA, BAGGASE, MUNICIPAL
REFUSED, BY PRODUCT, WOOD/ CHIPS ), MINYAK ( RESIDU , DISTILATE OIL ), GASEOUS ( LNG,
NG, LPG , GEOTHERMAL )
BERDASARKAN ISIAN PIPA ( PIPA API, PIPA AIR )
BERDASARKAN BUILDING CONSTRUCTION : FOOT - STAND ( PRESSURE PARTS BERDIRI
DIATAS FONDASI / TANAH) dan HANGING-UP ( PRESSURE PARTS TERPASANG DENGAN POSISI
TERGANTUNG PADA PILAR ). D.L.L.
BOILER BASICS
13
LANGKAH-2 UNTUK MENDAPATKAN ENERGY
YANG OPTIMUM DALAM DESIGN
BOILER BASICS
MENENTUKAN
PROSES /
BESARNYA
KEBUTUHAN
RUANG
PERTUKARAN
PANAS
MENENTUKAN JENIS
SUMBER ENERGY










COAL
WOOD
WASTES
OIL
STEAM
HI-TEMP. WASTE GAS
ELECTRICITY
MEMILIH SYSTEM
TRANSPORT
ENERGY





NATURAL GAS
STEAM
STEAM
MEMILIH EQUIPMENT
UNTUK KONVERSI
ENERGY







WATER TUBE BOILER
HEAT RECOVERY
BOILER
ELECTRIC BOILER
BERDASARKAN TUJUAN PENGGUNAAN BOILER ( STEAM GENERATOR )
1. UTILITY STEAM GENERATOR. STEAM YANG DIPRODUKSI KHUSUS UNTUK PEMBANGKIT TENAGA
LISTRIK
2. INDUSTRIAL STEAM GENERATOR. STEAM YANG DIPRODUKSI SELURUHNYA UNTUK PROSES
INDUSTRI
3. COMBINED STEAM COGENERATION :
A. TOP COGENERATION. SEBAGIAN BESAR STEAM YANG DIPRODUKSI UNTUK PEMBANGKIT
TENAGA LISTRIK. SISANYAN UNTUK PROSES INDUSTRI.
B. BOTTOM COGENERATUION SEBAGIAN BESAR PRODUKS STEAM UNTUK PROSES INDUSTRI.
SISANYA UNTUK PEMBANGKIT TENAGA LISTRIK.
14
D-TYPE PACKAGE
BOILER - INDUSTRIAL
D -TYPE PACKAGE BOILER
UTILITY - INDUSTRIAL
D-TYPE PACKAGE BOILER
UTILITY - INDUSTRIAL
MARINE V2M8 DENGAN U -
LOOP SUPERHEATER. TOP-FIRED
BURNER
A - TYPE
MARINE PACKAGE BOILER
BERBAGAI MODEL BOILER
TYPE PACKAGE DAN PENGGUNAANNYA
MARINE CE-SM.
Tekanan 60 Kg/Cm2. Kap. 70T/hr
BOILER BASICS
15
WATER TUBE BOILER
WATER TUBE BOILER
DENGAN FIRE DRUM
TYPE WET BACK
WATER TUBE BOILER
DENGAN FIRE TUBES
TYPE DRY BACK
FIRE TUBE Scotch Marine & Industrial
Tekanan 21 Kg/Cm2, Spreader Stoker
STEAM YANG DIHASILKAN
TEKANAN RENDAH (1- 2.5 kg/ cm
2
), TEMP. RENDAH ( 40 - 100
0
C )
DAN BASAH
PENGGUNAAN KHUSUS
FW TIDAK HARUS DIMURNI KAN
( TREATMENT )
PIPA API DENGAN UK. TEBAL
PADA FIRE DRUM BENTUK DRUM
BERGELOMBANG
COMBUSTION AIR SEKALIGUS
BERFUNGSI SEBAGAI FORCED
DRAFT FAN
BOILER BASICS
16
BENTUK / UKURAN KOMPAK ( KECIL, DAYA
OPTIMAL )
SIRKULASI NATURAL
PACKAGE [ DINDING] BOILER TERDIRI DARI 2
LAPIS. DIANTARA INNER DAN OUTER WALL
DILEWATI UDARA PEMBAKARAN. UDARA
PEMBAKARAN TSB. BERFUNGSI REGENERATIF
( PRE HEATER ) dan SEBAGAI ISOLASI RADIASI
PANAS
PRESSURE dan TEMPERATURE DIBATASI [ 25 - 35 ]
Kg / Cm
2
/ DIBAWAH 300
0
C.
RESPONSIF TERHADAP PEROBAHAN BEBAN
MARINE BOILERS
GAS
DINDING API
= REGENERATIVE
DINDING LUAR
= ISOLASI RADIASI
PACKAGE BOILER TYPE D
BOILER BASICS
17
PACKAGE BOILER TYPE D
VU- 60 BOILER
UNTUK INDUSTRIAL / UTILITY KECIL / COMBINED
TOP / BOTTOM
PRESSURE SESUAI TUJUAN PENGGUNAAN
NATURAL CIRCULATION
BH. BAKAR GAS / MINYAK
BAFFLE
SPHT
FURNACE
COMBUSTOR
STEAM
DRUM
BOILER
BANK
WATER
DRUM
BOILER BASICS
PACKAGE BOILER TYPE D BABCOCK WILCOX
UNTUK INDUSTRIAL / UTILITY KECIL / COMBINED
TOP / BOTTOM
PRESSURE SESUAI TUJUAN PENGGUNAAN
NATURAL CIRCULATION
18
STEAM GENERATOR DENGAN Bh. BAKAR REFUSED dan BATU
BARA KWALITAS RENDAH.
REFUSE - TO - ENERGY BOILER
DENGAN BH. BAKAR SISA BUANGAN
( AMPAS TEBU / BAGGASE )
1000 TON / DAY
INDUSTRI GULA TEBU
55 MW CIRCULATING FLUIDIZED - BED
COMBUSTION UNIT for LOW VOLATILE
BITUMINOUS COAL ( BATUBARA QUALITAS
RENDAH )
REFUSE CHARGING
HOPPER
FEEDER
UNDERGRATE AIR
PLUNGER
ASH
EXTRACTRO
GAS
OUTLET
STEAM
DRUM
COAL
SILO
BOILER BASICS
19
BOILER DENGAN SUMBER PEMANASAN DARI GAS
BUANG DARI SUMBER LAIN ( GAS TURBINE )
NON ADDITIONAL FIRING dan ADDITIONAL FIRING
SINGLE STEAM DRUM, DOUBLE STEAM DRUM ( LP -
HP ), TRIPLE STEAM DRUM ( LP - IP - HP )
SELANJUTNYA DIBAHAS KHUSUS PADA MODULE 1B
HRSG
HEAT RECOVERY STEAM GENERATOR ( HRSG )]
BOILER BASICS
BOILER SEGMENT
PADA HRSG
20
DIAGRAM PEMBANGKIT TENAGA UAP
TYPE UTILITY / INDUSTRIAL
UDARA
PEMBAKARAN
BH. BAKAR:
OIL /
GASEOUS
SATURATED STEAM
UNTUK INDUSTRIAL
PROCCESS
SUPERHEATED
STEAM UNTUK
UTILITY
SATURATED STEAM :

STEAM YANG MENGANDUNG X % AIR PADA TEMP. DAN
PRESSURE TERTENTU. + Y % STEAM . BERFUNGSI
UNTUK PROSES INDUSTRI
SUPEHEATED STEAM : 100% STEAM DALAM BENTUK STEAM +
0 % AIR BERFUNGSSI UNTUK
MENGGERAKKAN STEAM TURBINE.
SATURATED STEAM
STEAM YANG MASIH MENGANDUNG X % WATER DAN Y % STEAM
BERFUNGSI UNTUK PROSES [ INDUSTRI ]
TEMPERATURE dan PRESSURE RELATIF LEBIH RENDAH
SUPERHEATED STEAM
STEAM YANG MENGANDUNG( 0% WATER) dan (100% SUPERHEATED STEAM)
BERFUNGSI UNTUK MENGGERAKKAN STEAM TURBINE
TEMPERATURE DAN PRESSURE TINGGI ( DIATAS 460
0
C / DIATAS 50 KG / Cm
2
).
SUPERHEATER
B
L
R

B
A
N
K

F
U
R
N
A
C
E

W
A
L
L

T
U
B
E
S

BOILER BASICS
21
13
DIAGRAM PEMBANGKIT TENAGA UAP TYPE UTILITY
FURNACE
Pre heater
Precipitator
Pulverizer
ECONOMIZER
UDARA
INLET
ST.
TURBINE
CONDENSOR
STEAM
GENERATOR
1
2
3
4
5
6
7
8
BOILER BASICS
22
SIRKULASI PAKSA ( LANJUTAN )
PEMBANGKIT TENAGA LISTRIK
PLN UNIT #1 & #2 PAITON
KAPASITAS 400 MW.
TYPE CC - PP ( Controlled
Circulation Power Plant )
DILENGKAPI DENGAN BWCP
= Boiler Water Circulation Pump )
(STEAM PRESS. 225 Kg / Cm
2

STEAM TEMP. : 540
0
C
FUEL : OIL ( SOLAR ) UNTUK
PEMBAKARAN AWAL , COAL
UNTUK NORMAL OPERATION ,
dan GAS SEBAGAI
ALTERNATIVE.
COAL
COAL
FEEDER
PULVERIZER
COAL
NOZZLE
AIR HEATER
AIR FAN
BOILER BASICS
FLUE GAS
INITIAL
BURNING ZONE
REBURNING ZONE
PERFECT
BURNING ZONE
23
SCHEMATIC OF COAL FIRED UTILITY POWER PLANT
BATUBARA
PRECIPITATOR
SO2 SCRUBBER
STACK
BOILER
AIR HEATER
H.P. WATER
PREHEATERS
I.P. WATER
PREHEATERS
L.P. WATER
PREHEATERS
WATER TO BOILER
COAL PULVERIZER
COAL FEEDER
FORCED DRIVE FAN
PRIMARY FAN
INDUCED DRIVE
FAN
KONDENSOR
ST. TURBINES
BOILER BASICS
24
WATER - STEAM CIRCUTS
WATER
ECONOMIZER
SATURATED
STEAM
HP / HT
SUPERHEATED
STEAM
STEAM
TURBINE
LP/ LT
STEAM PROCESS
KONDENSOR
SWEET
WATER
TANK
LP / LT
SUPERHEATED
STEAM
LP/ LT
STEAM PROCESS
STEAM DRUM
WALL
TUBES
FURNACE
BOILER
BANK
WATER
DRUM
DOWN
COMER
DOWN
COMER
SYSTEMS
BLOW DOWN SYSTEM
BOILER BASICS
25
SYTEM TEKANAN PEMBAKARAN DIDALAM FURNACE
1. FORCED DRAFT SYSTEM
2. INDUCED DRAFT SYSTEM
1. FORCED DRAFT SYSTEM
FD FAN
BOILER BASICS
26
INDUCED DRAFT SYSTEM
FD FAN
ID FAN
AIR INLET
AIR
HEATER
PRECIPITATOR
ASH
HOPER
ASH HOPERS
FABRIC DENGAN
MUATAN ( + )
MUATAN (
- )
BOILER BASICS
27
SIRKULASI ALAMI
- NATURAL CIRCULATION
- THERMO - SYMPHONIC

SIRKULASI TERJADI KARENA BEDA
GRAVITASI AIR PANAS - DINGIN
TIDAK MENGGUNAKAN POMPA
DIAMETER PIPA BOILER LEBIH BESAR
DARIPADA BOILER DENGAN SIRKULASI
PAKSA
KAPASITAS BOILER LEBIH RENDAH
START - UP LEBIH LAMA
PERBANDINGAN SIRKULASI LEBIH
RENDAH DIBANDINGKAN DENGAN
SIRKULASI PAKSA.
TAHANAN ALIRAN : GESEKAN ANTARA
AIR - PIPA, AIR DEPOSIT, TITIK BELOK,
AIR - DRUM INTERNAL
CIRCULATION RATIO RENDAH ( = BERAT
AIR MASUK KE STEAM GENERATED
TUBES / BERAT STEAM YANG
DIHASILKAN STEAM GENERATED TUBES
YANG MASUK KE STEAM DRUM )
BOILER DENGAN SISTEM
SIRKULASI ALAMI
2. JENIS SIRKULASI WATER-STEAM
DIDALAM BOILER
LEBIH
DINGIN
LEBIH
PANAS
BOILER BASICS
28
SIRKULASI ALAMI ( lanjutan )
1. TINGGI BOILER
2. BESAR TEKANAN KERJA.
3. JUMLAH KALOR YANG DIBERIKAN
4. LUAS PENAMPANG PIPA YANG DILEWATI WATER dan WATER-STEAM.
1. MAKIN TINGGI / BESAR DIMENSI BOILER, MAKIN BESAR BEDA TEKANAN
BAGIAN YANG DIPANASI DAN BAGIAN YANG TIDAK DIPANASI
2. MAKIN TINGGI TEKANAN KERJA, MAKIN TINGGI KEPADATAN ( DENSITY )
WATER dan WATER-STEAM. BERARTI MENURUNKAN BEDA BAGIAN YANG
DIPANASI DENGAN BAGIAN YANG TIDAK DIPANASI.
3. MAKIN TINGGI KONSUMSI BH. BAKAR, MAKIN TINGGI STEAM YANG
DIPRODUKSI dan MAKIN RENDAH KEPADATAN WATER-STEAM. BERARTI
MENAIKKAN KECEPATAN SIRKULASI.
4. MAKIN BESAR LUAS PENAMPANG PIPA, MAKIN TINGGI KEPADATAN
SIRKULASI.
NOTE : PADA NATURAL CIRCULATION, UNTUK MENGHASILKAN [ X ] Kg
SATUAN BERAT STEAM, DIPERLUKAN SIRKULASI WATER
( 3 - 15 ) X
BESARNYA TOTAL SIRKULASI SANGAT DITENTUKAN OKEH 4 FAKTOR :
BOILER BASICS
29
CIRCULATION SYSTEM
SIRKULASI PAKSA ( FORCED DRIVE /
CONTROLLED CIRCULATION )
AIR DIPAKSA MENGALIR DENGAN
MENGGUNAKAN POMPA SIRKULASI
( BWCP )
KAPASITAS PRODUKSI UAP LEBIH TINGGI
DAN LEBIH CEPAT ( 1.8 JUTA KG / JAM )
START- UP LEBIH SINGKAT, SUHU AIR - UAP
SERAGAM, EXPANSI SEMUA BAGIAN BOILER
BERSAMAAN
DIFFERENTIAL PRESSURE DAPAT DIMONI -
TOR ANTARA HISAP dan TEKAN SEBELUM
WATER MASUK KE STEAM RISER. DARI SINI
BERFUNGSI JUGA UNTUK MENGETAHUI
ADANYA PEMBENTUKAN DEPOSIT.
DIAMETER PIPA - PIPA BOILER LEBIH KECIL,
LUAS PERMUKAAN BIDANG PERTUKARAN
PANAS LEBIH BESAR
INSTALASI MENJADI LEBIH RUMIT KARENA
ADANYA POMPA SIRKULASI
PERBANDINGAN SIRKULASI :
Cr ( Ratio of Circulation ) = PERBANDINGAN
AIR TURUN MELALUI DOWNCOMER DENGAN
STEAM YANG MENINGGALKAN AIR DIDALAM
STEAM GENERATOR TUBES
Boiler dengan sirkulasi paksa
ORIFICE
FUNGSI ORIFICE :
- MEMBUAT PRESSURE DROP
- MENGUKUR FLOW
- MENGATUR FLOW BALANCE
POMPA
SIRKULASI
W
S
Cr =
S
W
BOILER BASICS
30
SIRKULASI PAKSA ( LANJUTAN )
PEMISAHAN WATER-STEAM DIDALAM STEAM DRUM MEMERLUKAN PERHITUNGAN DESIGN
LEBIH RUMIT. PEMISAHAN MENJADI INTENSIF DENGAN TURBO SEPARATOR. DENGAN TURBO
SEPARATOR, UKURAN STEAM DRUM MENJADI LEBIH KECIL.
BILA BOILER DIDESIGNED UNTUK BEKERJA PADA TEKANAN KRITIS ( > 3208 psi / 221 bar)
DIMANA WATER DALAM WAKTU SANGAT SINGKAT BEROBAH MENJADI STEAM, UKURAN DRUM
MENJADI LEBIH KECIL LAGI. BAHKAN TIDAK DIPERLUKAN STEAM DRUM LAGI. KONDISI INI
DIKENAL DENGAN ONCE-THROUGH CIRCULATION .

CIRCULATION RATIO
ADALAH PERBANDINGAN ANTARA BERAT WATER YANG MASUK KE DOWNCOMER ( W ) DENGAN
BERAT STEAM DIDALAM CAMPURAN WATER-STEAM YANG MENINGGALKAN STEAM RISER
TUBES ( S ).
LOW LOAD CIRCULATION RATIO
ADALAH PERBANDINGAN ANTARA SIRKULASI WATER (W ) DENBGAN STEAM ( S ) BERDASARKAN
BEDA TEMPERATURE ( THERMAL HEAD ) YANG SELANJUTNYA TERGANTUNG PADA TEKANAN
BOILER, JUMLAH WATER YANG MASUK KE DOWNCOMER AKAN MENINGKAT SEMENTARA LOAD
BERKURANG.
KESIMPULAN :
BILA BEBAN BOILER KURANG DARI 50% MCR ( MAXIMUM CONTINUOS RATE = KAPASITAS MAX.
YANG KONTINYU ), PERBANDINGAN SIRKULASI AKAN SEMAKIN BESAR. EFFISIENSI AKAN
MENJADI RENDAH.
BOILER BASICS
31
FLOW BOILING
1. ADA HUBUNGAN YANG ERAT ANTARA GRAVITY,
MATERIAL DAN MEKANISME PERPINDAHAN
PANAS
2. AIR MASUK KEDALAM PIPA DENGAN TEMP. SUB
BOILED. MELALUI PROSES KONVEKSI, PANAS
DISERAP DARI PIPA KE AIR
3. AIR MULAI SUBCOOLED BOILING DAN BUBBLE
FLOW ( GELEMBUNG ). TEMP. TERUS NAIK
MENCAPAI SATURATION TEMP. DAN MULAI
TIMBUL NUCLEATE BOILING.
4. DI DAERAH INI DIMULAINYA PROSES PERO-
BAHAN WATER - STEAM ( BUBBLE -
INTERMEDIATE DAN ANNULAR )
5. PERPINDAHAN PANAS TERUS BERLANJUT,
DIMANA TERCAPAI KEADAAN ANNULAR FLOW
YANG SANGAT TIPIS ( NUCLEATE ). MULAI DI
DAERAH INI PROSES PERPINDAHAN PANAS
SECARA KONDUKSI DAN KONVEKSI
( CONVECTIVE BOILING ) . MULAI TIMBUL CHF
( CRITICAL HEAT FLUX ).
6. DI DAERAH CONVECTIVE BOILING KENAIKAN
TEMP. SANGAT PESAT dan WATER BEROBAH
MENJADI SATURATED STEAM.
APABILA PROSES INI BERLANGSUNG DALAM
WAKTU YANG SANGAT SINGKAT DAN SERING
TERJADI, BERAKIBAT PIPA CEPAT RUSAK .
BOILER BASICS
32
DNB = DEPARTURE from NUCLEATE BOILING
ADALAH KEADAAN ( BEBERAPA SAAT BERSAMAAN
TERJADINYA PEROBAHAN LOAD YANG BESAR /
MENDADAK ) DIMANA PANAS YANG DIBERIKAN
( DARI PEMBAKARAN ) MELEBIHI JUMLAH WATER
STEAM DIDALAM STEAM RISER.
TERBENTUK KANTONG STEAM PADA DAERAH YANG
LUAS DIDALAM PIPA, MEMBENTUK LAPISAN TIPIS
( ANNULAR ) YANG MENGHAMBAT PROSES
PERTUKARAN PANAS DARI GAS KE PIPA KE WATER /
STEAM.
APABILA KEADAAN DNB INI BERLANGSUNG CUKUP
LAMA ATAU SERING TERJADI, PIPA AKAN CEPAT
RUSAK
AKIBAT YANG TIMBUL :
- OVERHEATED TUBE FAILURES
- PEMBENTUKAN DEPOSIT PADA SISI AIR
- SULIT MENGATUR TINGGI AIR DALAM DRUM
- WATER CARRY AKIBAT TURBULENSI YANG BESAR
DAPAT DIHINDARI DENGAN MENAMBAH BEBAN
BOILER DENGAN BERTAHAP (SEDIKIT DEMI SEDIKIT )
D
A
E
R
A
H

Y
A
N
G

P
O
T
E
N
S
I
A
L


C
E
P
A
T


R
U
S
A
K

BOILER BASICS
33
HEAT TRANSFER ( PERPINDAHAN PANAS )
DIDALAM PROSES PERTUKARAN PANAS DIDALAM
BOILER TERJADI TIGA PROSES ( KONDUKSI,
KONVEKSI DAN RADIASI ) SECARA BERSAMAAN .
BESAR / KECEPATAN PERTUKARAN PANAS
TERGANTUNG PADA LUAS BIANG, KONDISI
PERMUKAAN BIDANG ( HALUS / KASAR, BERSIH /
KOTOR, KILAP / BURAM, TERANG / GELAP ), JARAK
SUMBER PANAS KE BIDANG PENERIMA PANAS,
KECEPATAN ALIR DARI GAS DAN JENIS MATERIAL
YANG DIPANASI ( MURNI / BERLAPIS ).
GAS
PANAS
JELAGA
PIPA
RUGI
PENGARUH KETEBALAN JELAGA TERHADAP
PERTUKARAN PANAS
1/32 SOOT
RUGI 9.5%
1/16 SOOT
RUGI 26.2 %
1/ 8 SOOT
RUGI 45,3 %
3 / 16 SOOT
RUGI 69 %
W
A
T
E
R

DEPOSIT
BOILER BASICS
34
BOILER BASICS
STEAM DRUM INTERNALS
Screen Dryer
Separator
BLOWDOWN
CHEMICAL LINE
TUBE RISER / STEAM
GENERATOR
FEEDWATER INLET
MENCEGAH PERCIKAN
AIR MASUK KE
SALURAN STEAM.
STEAM LOLOS MASUK
KE SEPARATOR
MENCEGAH AIR TITIK-2 MASUK
KE SALURAN STEAM. HANYA
STEAM YANG LOLOS MASUK KE
SALURAN STEAM
MEMISAH STEAM DARI
AIR DENGAN CARA
SENTRIFUGAL. STEAM
( RINGAN ) MASUK KE
SCREEN. AIR ( LEBIH
BERAT ) JATUH KEMBALI
KE AIR
TURBO SEPARATOR
BAFFLE PLATE
UNTUK MEMBELOKKAN ARAH
ALIRAN ( WATER + STEAM YANG
PANAS ) TIDAK LANGSUNG
BERCAMPUR DENGAN
FEEDWATER YANG MASIH
DINGIN
BAFFLE PLATE
UNTUK MENCEGAH FEED WATER (
DINGIN ) BERCAMPUR LANGSUNG
DENGAN WATER DI DALAM DRUM (
PANAS )/ MENCEGAH THERMAL
SCHOCK PADA DRUM METAL
UNTUK MEMBUANG FEEDWATER DI
DALAM STEAM DRUM BILA KADAR
GARAM DIATAS BATAS MAX.
UNTUK MENGISI FEEDWATER
KEDALAM ST. DRUM AGAR TINGGI
GARIS SELALU KONSTAN.
WATER + STEAM DARI STEAM
RISER ( WATER WALL & BOILER
BANK ) MASUK KEDALAM ST.
DRUM.
STEAM + WATER
WATER
UNTUK MEMASUKKAN BH. KIMIA
MENCEGAH PEMBENTUKAN
SCALES, SLUDGE, CORROSION
SECARA PERIODIK DI SUPPLY
UNTUK MENJAGA AGAR
FEEDWATER TETAP MURNI
UNTUK MENGALIRKAN FEEDWATER
KELUAR DARI ST. DRUM DAN
MASUK KE WATER DRUM DAN
SELANJUTNYA MASUK WALL TUBES /
BOILER BANK
DOWN COMER
35
STEAM - WATER SEPARATION ( PEMISAHAN UAP - AIR )
FUNGSI ( TAMBAHAN ) STEAM DRUM
1. MENCAMPUR FW. DENGAN SATURATED WATER YANG
TER[PISAH DARI STEAM
2. MENGONTROL KOROSI DAN WATER TREATMENT ( BILA
DILENGKAPI )
3. MEMISAHKAN KONTAMINANT DAN RESIDUAL MOISTURE DARI
STEAM
4 MEMBUANG SEBAGIAN DARI FW. ( BLOWDOWN ) UNTUK
MENGATUR BOILER WATER CHEMISTRY DAN DEPOSITS
KERAS
5. MENGATUR JUMLAH AIR DALAM ST. DRUM UNTUK
MENGANTISIPASI PEROBAHAN LOAD BOILER DENGAN CEPAT.
FUNGSI ( UTAMA ) ST. DRUM
1. MEMISAH STEAM DARI SAT. WATER DENGAN EFEKTIF
2. MENCEGAH WATER DROPLETS CARRY OVER KEDALAM
SUPERHEATER TUBING KARENA THERMAL SCHOCK.
3. MENCEGAH SEKECIL MUNGKIN STEAM CARRY UNDER
KEDALAM WATER YANG RESIRKULASI KEDALAM
DOWNCOMERS.
4. MENCEGAH DEPOSIT/ SOLIDS ( SCALE ) CARRY OVER KE
SUPERHEATER DAN / ATAU KE TURBIN. SOLIDS ( SCALES )
TERBAWA BERSAMA FW ATAU SWEETWATER
( MAKEUP WATER ).
BOILER BASICS
36
BEKERJA BERDASARKAN GERAK PUTAR DARI STEAM + WATER. KARENA GAYA SENTRIFUGAL,
WATER TERLEMPAR KEARAH LUAR, STEAM MENGALIR DI TENGAH TURBO CYCLONE.
STEAM DITAHAN BAFFLE KEMBALI KE WATER. STEAM TETAP MENGALIR KEARAH ATAS.
MENCEGAH WATER CARRYOVER, STEAM CARYYUNDER dan CARRY OVER OF SOLIDS.
MENCEGAH WATER CARRY OVER DENGAN MEMASANG BAFFLE PLATES, SCRUBBER
ELEMENTS
MENCEGAH STEAM CARRYUNDER DENGAN MEMASANG MANIFOLD BAFFLE PLATES.
TYPE A
TYPE B
STEAM
WATER
TURBO CYCLONE
BOILER BASICS
37
PENGARUH WATER CARRYOVER dan STEAM CARRYUNDER
MOISTURE CARRYOVER KEDALAM STEAM
STEAM CARRYUNDER KEDALAM WATER
TERJADI SECARA BERTAHAP ( SEDIKIT DEMI SEDIKIT ) SAMPAI KE TITIK DIMANA SATURATED
WATER MENCAPAI MAX. DISUSUL WATER CARRYOVER SECARA MENDADAK.
DIIKUTI DENGAN KENAIKAN WATER LEVEL SAMPAI TERJADI OVER FLOW ( MELIMPAH )
SAMPAI TERJADI KENAIKAN STEAM QUALITY
WATER LEVEL MENURUN
INLET STEAM QUALITY TURUN
FAKTOR MEMPENGARUHI KECEPATAN PEMISAHAN WATER - STEAM
DESIGN FAKTOR
PRESSURE
DIMENSI DRUM
KECEPATAN PEMBENTUKAN STEAM
QUALITRAS INLET STEAM RATA-2
TYPE & KONSTRUKSI SEPARATORS
KONSTRUKSI EQUIPMENT FW SUPPLY &
STEAM DISCHARFED
KONSTRUKSI DOWN COMER & RISER
CONNECTIONS TERHADAP DRUM
FAKTOR PENGOPERASIAN
PRESSURE
BOILER LOAD ( STEAM FLOW )
TYPE OF STEAM LOAD
CHEMICAL ANALYSIS PADA FW
WATER LEVEL
BOILER BASICS
38
STEAM DRUM CAPACITY
VOLUME WATER dan VOLUME SATURATED STEAM HARUS
MAMPU MEMENUHI SETIAP PEROBAHAN LOAD (NAIK / TURUN)
DENGAN AMAN TERHADAP TURBINE dan AMAN TERHADAP
BOILER ( SUPERHEATER TUBES )
STEAM TIDAK TERBAWA ALIRAN WATER KE DOWN COMERS
BILA STEAM LOAD BERTAMBAH DALAM WAKTU SANGAT
SINGKAT / MENDADAK dan DALAM JUMLAH BESAR,
MENGAKIBATKAN KEADAAN SBB. :
- WATER LEVEL TURUN ( L
B
)
- TEKANAN STEAM TURUN
- VOLUME STEAM MENINGKAT
- QUALITAS STEAM TURUN ( % WATER DALAM STEAM NAIK )
L
a

L
b

TIMBUL SWELL ( GELOMBANG BESAR KARENA TEKANAN TIBA - 2 BERKURANG, SEDANGKAN
TEKANAN FEED WATER PUMP KONSTAN ). AKIBAT LANGSUNG, WATER LEVEL SULIT DIBACA.
BILA FIRING RATE TERLAMBAT, WATER LEVEL AKAN NAIK ( L
a
), VOLUME STEAM BERKURANG.
BILA BERLANJUT BISA MENYEBABKAN WATER CARRY OVER ATAU SUPPLY WATER
TERLAMBAT, WATER LEVEL TERUS TURUN MENCAPAI TUBE RISER. HAL INI SANGAT
BERBAHAYA KARENA MENGAKIBATKAN PIPA OVER HEATED
DAN SEBALIK NYA BILA LOAD TIBA-2 BERKURANG DALAM JUMLAH BESAR.
DI KENDALIKAN DENGAN 3 WAY CONTROLLED SYSTEM ( DRUM LEVEL - STEAM FLOW -
FEEDWATER FLOW ).
OVERHEATED
BOILER BASICS
39
COMBUSTION SYSTEMS
FURNACE
GAS & FLUEGAS CIRCUITS
COMBUSTOR / BURNER
COMBUSTION AIR ( PA & SA )
EMISSION EMISSION CONTROL
SALURAN GAS DAN FLUEGAS DARI FURNACE
KE TITIK PEMBUANGAN KE ATMOSFER /
STACK.
FORCED DRAFT FAN ( FD FAN ) MENSUPPLY UDARA PEMBAKARAN
INDUCED DRAFT FAN ( ID FAN ) MEMBUAT TEKANAN UDARA / GAS DIDALAM GAS DUCT
LEBIH RENDAH DARI TEKANAN ATMOSFER( MEMBANTU PROSES PEMBAKARAN
DENGAN BH. BAKAR BATUBARA.
UDARA UNTUK PROSES PENGERINGAN BATU BARA / BAGASSE
UDARA UNTUK TRANSPORTASI BAGASSE / PUVERIZED COAL DARI PULVERIZER KE
FURNACE
MENSUPPLY BH. BAKAR KEDALAM FURNACE ( COAL NOZZLES , OIL GUNS, GAS NOZZLE )
DAMPER ( PINTU UNTUK MENGATUR BESARNYA SUPPLY UDARA PEMBAKARAN ), SWIRLER MENGATUR AGAR
UDARA MASUK KEDALAM FURNACE DALAM BENTUK PUSARAN
MENGONTROL GAS YANG KELUAR DARI STACK TIDAK MENIMBULKAN
PENCEMARAN TERHADAP LINGKUNGAN / POLUSI )
BENTUK EMISI :
NOX, SOX, THERMAL, CHEMICAL , DEBU , RACUN,
YANG DILINDUNGI :
MAKHLUK HIDUP, TANAMAN, BANGUNAN & ALAM
RUANG PEMBAKA -
RAN YANG DIBA -
TASI DENGAN PIPA -
2 WATER / STEAM
( WALL TUBE )
BOILER BASICS
40
BERDASARKAN KEUNTUNGAN :
1. EKONOMIS . PENYIAPAN FUEL MUDAH / MURAH
2. VOLUME FURNACE KECIL DENGAN MEMANFAATKAN GERAK CYCLONE
3. PEMBENTUKAN FOULING SANGAT RENDAH ( 15-30 ) % DARI FUEL ASH YANG MASUK KE
CONVECTION PASS DARI 80% FLUE GAS YANG LEWAT ( DENGAN BH. BAKAR COAL )
CYCLONE FURNACE ( 1940 )
CYCLONE FIRING ADALAH PROSES PEMBAKARAN
DENGAN MEMANFAATKAN GERAK UDARA
PEMBAKARAN ( SECONDARY AIR ) & FUEL
SECA RA TANGENTIAL AGAR MENCAPAI EFISIENSI
PEMBAKARAN MAXIMUM.
FUEL :
OIL ( ATOMIZED )
COAL ( PC = PULVERIZED COAL ). 70 % MELEWATI
200 MESH ( 74 MICRON ) SCREEN.
AIR DISTRIBUTION
PRIMARY AIR ( PA ) BERFUNGSI UNTUK
MENGALIRKAN DAN SEKALIGUS MENGERINGKAN
PC DARI COAL MILL KE BURNER
SECONDARY AIR (SA ) BERFUNGSI TERUTAMA
UNTUK LANGSUNG MEMBAKAR FUEL..
TERTIARY AIR ( TA ) BERFUNGSI UNTUK PROSES
PEMBAKARAN AWAL, MENGALIR SEPANJANG
CYCLONE AXIS
FUEL FIRING SYSTEMS
FURNACE DESIGN UNTUK UTILITY / INDUSTRIAL BOILER
BOILER BASICS
41
BOILER BASICS
OIL BURNER TYPE R ( ALSTOM
AIR DAMPER WIND BOX
FURNACE
WALL TUBE
IGNITOR
OIL GUN
PRIMARY AIR
TYPE R OIL BURNER
BURNER
THROAT
SECONDARY AIR
OBSERVATION
HOLE
TYPE SV GAS BURNER
42
COAL FIRING SYSTEMS PADA UTILITY BOILER TYPE ( PAITON )
TANGENTIAL - FIRING WINDBOX
TERPASANG PADA UTILITY / INDUSTRIAL
BOILER
PRIMARY FUEL : COAL.
PRELIMINARY FIRING FUEL : OIL / SOLAR
MAIN / SUPPLEMENT FUEL : GASEOUS /
OIL.
27.5 0 TILT-UP ATAU 27.5 0 TILT-DOWN
UNTUK MENGATUR TEMP. SUPERHEATER
STEAM. START-UP PADA POSISI
HORIZONTAL
START-UP DENGAN PEMBAKARAN OIL
GUN. SETELAH PANAS MERATA DAN TEMP.
FLUE GAS MENCAPAI MINIMAL UNTUK
PENGERINGAN PC. PEMBAKARAN DIAMBIL
ALIH OLEH COAL NOZZLE.
BUKA / TU

TUP DAMPER SESUAI BOILER LOAD.
DIGERAKKAN MELALUI DAMPER DRIVE
MECHANISM.
FLAME MONITOR DENGAN IFM ( ( IONIC FLAME MONITOR ) DAN CONTROL DENGAN FSSS
( FURNACE SAFEGUARD SUPERVISORY SYSTEM )
OFA ( OVER FIRE AIR ) : DISUPPLY DARI NOZZLE ELEVASI TERATAS. BERFUNGSI UNTUK
MENCEGAH TEMP. GAS MENCAPAI MAX ( THERMAL NOX ). Nox max. 0.45 lb / million Btu.
Panas yang dihasilkan
BOILER BASICS
43
BOILER BASICS
PENGATURAN TEMPERATURE PEMBAKARAN
POSISI BURNER HORIZONTAL [ 0
0
]
UNTUK START- UP DAN BEBAN
NORMAL KONSTAN
LIGHT-OFF AWAL DENGAN DENGAN
BH. BAKAR MINYAK UNTUK [ ]
PEMANASAN WALL TUBES.
TEMPERATURE AIR HEATER DARI PA
FAN CUKUP, BATU BARA MULAI
DIBAKAR
TEMP. & TEKANAN STEAM SIAP
DIOPERASIKAN.
TEMPERATURE SUPERHEATED
STEAM TERLALU TINGGI,
POSISI BURNER DITURUNKAN (
TILT-DOWN ) [ -27
0
]
- TEMP. SPHT TURUN
- TEMP. WATER CEPAT NAIK
- TETAPI TEMP SATURATED
STEAM TURUN
SETELAH STABIL, POSISI
BURNER 0
0

TEMP. SPHT STEAM
TERLALU RENDAH, POSISI
BURNER DINAIKKAN ( TILT-
UP) [ +27
0
]
- TEMP. SPHT NAIK
- TEMP. WATER TURUN
- TETAPI TEMP SATURATED
STEAM NAIK
SETELAH TEMP. STABIL,
POSISI BURNER 0
0

44
FURNACE DESIGN UNTUK UTILITY / INDUSTRIAL BOILER
CYCLONE PATERN ( Dikenal sbg.LNCFS = Low Nox
Concentric Firing Systems )
1. HORIZONTALLY INTRODUCED
2. VERTICAL FLOW
3. OFA ( OVER FIRE AIR )
SPRAY PATERN
1. FIXED ANGLE
2. VARABLE ANGLE
FLAME MONITOR
IFM ( IONIC FLAME MONITOR = FLAME SCANNER )
FUEL FIRING SYSTEMS
25 0
OXYGEN RICH
WINDBOX
22 0
OFA
1090

0
C
1427
0
C
FUEL / COPAL
UDARA
PEMBAKARAN
BENTUK NYALA
PEMBAKARAN
BOILER BASICS
45
BOILER BASICS
WEIGHING MODULE
COAL ON BELT SENSOR
BELT SCRAPER
TAKE UP
PULLEY
CLEANOUT CONVEYOR
LOAD BOILER MEMBERI SIGNAL KE MOTOR PENGGERAK PULLEY , MENGATUR KECEPATAN PUTAR
BERFUNGSI UNTUK MENIMBANG BERAT COAL YANG HARUS DI SUPPLY UNTUK DIBAKAR SESUAI LOAD
BOILER
MAKIN BERAT BEBAN PULLEY, MAKIN RENDAH KECEPATAN PUTARNYA.. DAN SEBALIKNYA.
SEAL AIR
VALVE
BOILER LOAD
SCALE CONTROL
MOTOR
COAL FEEDER
[ MENSUPPLY COAL SESUAI BEBAN TURBINE )
TURBINE LOAD
46
PROSES PENANGAN BT. BARA
Ke Burner
50 grams
Sisa 0.025 grams
dengan mesh 30
Sisa 0725 grams
dengan mesh 50
Sisa 4.5 grams
dengan mesh 100
Sisa 9.75 grams
dengan mesh 200
49.975
gram lolos
49.25 gram
lolos
44.75 gram
lolos
35 gram
lolos
GRIND ABILITY
BOILER BASICS
SIAP DI DISTRIBUSI
47
BOILER BASICS
1st
STATIONARY
SECTION
(CLASIFIER)
DSVC = DYNAMICALLY STAGE VARIABLE SPEED
( MODEL B&W )
2nd
STATIONARY
SECTION
48
FURNACE DESIGN UNTUK UTILITY / INDUSTRIAL BOILER
FUEL FIRING SYSTEMS
FUEL
AIR
FLAME SCANNER DI BUNGKUS
UDARA YANG BERFUNGSI SEBAGAI
COOLER.
MENYUDUT KE TITIK FOCUS FLAME.
SENSOR BERDASARKAN TEMP.
TERTINGGI DAN JUGA BERDASARKAN
WARNA NYALA ( ULTRA
VIOLET ).
MAIN OIL BURNER
SECONDARY
GAS NOZZLE
OIL & GAS BURNERS
BERFUNGSI SEBAGAI PRIMARY BURNER DAN /
ATAU AUXILIRY BURNER
UDARA ( SECONDARY ) MASUK KE BURNER
MELALUI WHIRLING VANES . UDARA
( PRIMARY) MASUK LANGSUNG KE NOZZLE
BH. BAKAR GAS MASUK BERSAMA SECONDARY
AIR
BOILER BASICS
49
BOILER BASICS
SISTEM PEMBAKARAN BATUBARA
BATU BARA HARUS DILEMBUTKAN ( PULVERIZED ) SEPERTI BENTUK
TEPUNG UNTUK MEMPERBESAR LUAS BIDANG HEX.
PENGALIRAN SERBUK BATU BARA DENGAN MENGGUNAKAN UDARA
PEMBAKARAN YANG TELAH DIPANASKAN ( PRE-HEATED ) DI AIR
HEATER
NILAI KALOR TIDAK TERLALU TINGGI
% KARBON TINGGI, % KELEMBABAN TINGGI
MUDAH MENDAPATKAN / MURAH HARGA, TIDAK PERLU TEMPAT
PENYIMPANAN KHUSUS
SULIT TERBAKAR DAN BILA SUDAH TERBAKAR SULIT DIPADAMKAN
MEMERLUKAN ALAT PEMBERSIH DEBU / ABU KHUSUS
( EP = ELECTRO PRECIPITATOR )
HEATING VALUES BT.BARA 13. 335 Btu / lb,
MINYAK = 18. 538 Btu / lb, Natural gas = 23. 865 Btu / lb.
SISTEM PEMBAKARAN FUEL OIL
OIL & NATURAL GAS = FOSSIL FUEL = RANGE : CRUDE OIL - DISTILATE OILS ( DIESEL , LIGHT
dan HEAVY RESIDUAL OILS ).
HHV = 18.250 - 20. 000 Btu / Lb.
AGAR MUDAH DAN CEPAT TERBAKAR, OIL HARUS DI ATOMIZED . MAKIN MENDEKATI SIFAT
CRUDE OIL, OIL HARUS DIPANASKAN SEBELUM DI KABUTKAN ( ATOMIZED ).
LAKUKAN TEST PENERIMAAN dan SEBELUM DIBAKAR ( % WATER, FLASH POINT, FIRE POINT,
VISCOSITY,
FLASH POINT = TERBAKAR DENGAN SENDIRINYA KARENA TEMPERATURE RUANG = TITIK NYALA
-----------> UNTUK KEAMANAN PENYIMPANAN
FIRE POINT = TERBAKAR KARENA BERSENTUHAN DENGAN SUMBER PANAS ( MIS. BUSI ). OIL #4,
# 5 & # 6. VISCOSITY = KEKENTALAN. MAKIN TINGGI TEMP. , MAKIN ENCER. DIATAS TEMP.
250
0
F / 120
0
C STABIL ( CAIR KE GAS )
50
SIFAT-2 FOSSIL OIL ( NATURAL GAS ) BOILER BASICS
LUMPUR
/ ASPAL /
SISA
MINYAK
MENTAH
GAS SISA
STEAM / HOT GAS
STEAM
COIL
RESIDU
SOLAR
KEROSENE
AVTUR
AVGAS
BENZENE
LPG
BASIC REFINERY PROCESS
SEBAGAI BH. BAKAR IDEAL ( % WATER KECIL, NO ASH, NO
SULFUR. NO PUMP, NO SCRABER ).
TIDAK BERWARNA dan TIDAK BERBAU.
LNG TERDIRI DARI BEBERAPA JENIS GAS LAIN YANG
BERBEDA ( CO2, N2, CH4, C2H6 ). HHV
ANTARA [ 843 - 1548 ] BILA % PROPANE dan ETHANE TINGGI
= 2000 Btu / Cu. Ft. RATA-2 = 1000 Btu / Cu. Ft.
KEUNTUNGAN



KERUGIAN :





METHOD ANALYSIS : ANALISA KIMIA, INFRA RED
SPECTROMETRY, MASS SPETROMETRY dan GAS
CHROMATOGRAFY.
1. UNTUK KAPASITAS YANG SAMA, BOILER DENGAN GAS
FIRED MEMPUNYAI DIMENSI KECIL DIBANDINGKAN
DENGAN YANG OIL / COAL FIRED.
2. TIDAK MEMERLUKAN TANGKI PENYIMPANAN.
1. % HYDROGEN TINGGI --------> % WATER SETELAH PROSES
PEMBAKARAN.
2. EFISIENSI BOILER RENDAH ( KALOR PEMBAKARAN
SEBAGIAN BESAR UNTUK MEROBAH WATER ( DALAM
F;LAME ) MENJADI VAPOR / STEAM.
3. [ O2, N2, CO2 ] TIDAK MENGHASILKAN KALORI PANAS.
51
BOILER BASICS SIFAT-2 FOSSIL ( OIL FUEL )
SEBAGAI HASIL CRACKING atau DISTILASI MINYAK MENTAH.
SIFAT 2 FISIKA YANG HARUS DIPERTIMBANGKAN : VISKOSITAS, VOLATILITY
( DAYA PENGUAPAN ), GRAVITY, POUR POINT ( TITIK TUANG ), FLASH POINT (
TITIK NYALA ), BURNING / IGNITION POINT ( TITIK TERBAKAR ), ACIDITY (
DERAJAT KEASAMAN ), % CARBON, RESIDU KARBON, % SULFUR, % ASH ,
AIR dan ENDAPAN, , NILAI KALOR ( HHV dan LHV ), CORROSIVENESS,
SIFAT ALAMI Bh. BAKAR MENJADI PARAMETER DALAM MENDESIGN SEBUAH
BOILER ( BENTUK, KONFIGURSI PIPA-2, LUAS BIDANG PERTUKARAN PANAS
dan SISTEM PEMBAKARAN YANG DIPILIH.
HYDRO CARBON BASED. JUMLAH HYDROGEN VARIATIF TERGANTUNG
DIMANA DI TAMBANG. UMUMNYA ELEMEN HYDROGEN [ 15 - 18 ] % BERAT.
ELEMEN LAIN PARAFIN,
UNTUK Bh. BAKAR BOILER VARIATIF GOLONGANNYA : RESIDU ( MFO ) Mi.
DIESEL BERAT ( MDF )
UNTUK EFISIENSI, Bh. BAKAR CAIR BERAT MEMERLUKAN PREHEATING
PROSES.
KANDUNGAN KARBON RELATIF TINGGI. BERAKIBAT ABRASI CUKUP TINGGI
dan PEMBENTUKAN SOOT TINGGI.
YANG PERLU DIWASPADAI ADALAH KANDUNGAN SULFUR HARUS SERENDAH
MUNGKIN MAX [ 0.5 2.0 ] % UNTUK MENGHIDARKAN TIMBULNYA SOX
PADA EMISI GAS BUANG. . Dst..
NILAI KALORI
MAKIN BESAR-
MAKIN ENCER
MAKIN KENTAL-
MAKIN GELAP-
MAKIN TINGGI
KARBON
SIFAT-2 FOSSIL ( COAL FUEL )
DIBAHAS KHUSUS
52
INDUSTRIAL BOILER
ALTERNATIVE PENGGUNAAN BH. BAKAR dan SISTEMNYA
PADA UMUMNYA MENGGUNAKAN COAL dan / atau REFUSED PRODUCT A.L. :
BAGGASE, BIOMASS, REFUSED DERIVED FUEL( RDF ), MUNICIPAL SOLID WASTE ( MSW ),
COAL -SPREADER STOKER DAN COAL PULVERIZED ( PC ) DENGAN PERTIMBANGAN EKONOMI :
FUEL PRICE, FUEL PROCESS COST ( SHIPMENT, PROCESSING COST, HANDLINGS ETC)
CP - FIRED ;
CARBON TIDAK TERBAKAR 0.4%
EFFISIENSI PEMBAKARAN LEBIH TINGGI
KARENA KELEMBUTAN COAL MENCAPAI 200
MESH SCREEN ( 70 - 80 ) % PC
SLAGGING DAN / ATAU FOULING TERJADI
DIDAERAH KANTUNG
PILIHAN CP FIRED Vs STOKER - FIRED BOILER
CP - FIRED
KARBON TIDAK TERBAKAR 4 - 8 %
EFISIENSI PEMBAKARAN RENDAH KARENA COAL LE
-BIH KASAR 20 MESH SCREEN ( 20 mm )
CENDERUNG MEMBENTUK CLINKER ( GUMPALAN
KERAK )
MENENTUKAN TINGGI STACK BERKAITAN DENGAN EMISI.
MENENTUKAN VOLUME FURNACE BERKAITAN DENGAN TIME DALAM
PROSES PEMBAKARAN.
FUEL FIRING SYSTEMS
BOILER BASICS
53
FUEL FIRING SYSTEMS
STOKER FIRING SYSTEM
OVERFEED STOKER
TRAVELLING - GRATE STOKER
RESPONSIVE THD. PEROBAHAN
LOAD
PENGERINGAN SEMENTARA FUEL
MELAYANG . TERBAKAR SEBELUM
JATUH KE TRAVELLING GRATE.
KLINKER MINIMAL
CELLULOSE FUELS ( WOOD,
BAGGASE, RESIDUE SLUDGE, RICE
HULLS, COFFE GROUNDS, DLL )
UNDERFEED STOKER
COCOK UNTUK CONSTANT LOAD
CENDEREUNG MEMBENTUK CLINKER

TANGENTIAL
OFA ( 5 - 20 % )
ACTIVE
COMBUSTION
ZONE
COKING
ZONE
AUX.
AIR
AUX.
AIR
PRIMARY
AIR
ASH ASH
OFA = OVER FIRE AIR
BERFUNGSI UNTUK MENCEGAH TEMPERATURE
GAS PEMBAKARAN MENCAPAI MAX. DAN
MENGONTROL TEMP. SUPERHEATERS.
TEMP. UDARA MAX. BERAKIBAT MERUSAK
LINGKUNGAN MEMBENTUK NOX DAN SOX.
CARBON -
RECOVERY
NOZZLE
DISTRIBUTOR
RETURN RAILS
GRATES
BOILER BASICS
54
SUPERHEATER
PIPA - PIPA PENGERING UAP SATURATED MENJADI
KERING ( SUPERHEATED STEAM )
BERLAKU HUKUM GAS SEMPURNA
KHUSUS UNTUK MENGGERAKKAN TURBIN UAP
MAKIN TINGGI TEKANAN DAN TEMP. UAP SPHT. MAKIN
TINGGI MENYIMPAN KALORI / ENERGY PANAS
PENEMPATAN DIDALAM BOILER :
N LANGSUNG DIDAERAH RADIASI PEMBAKARAN
N ATAU DIBELAKANG PIPA - PIPA AIR YANG BERFUNGSI
SEBAGAI SCREEN / BAFFLE SESUAI TEMP. UAP
YANG DIBUTUHKAN

EKONOMIZER
FUNGSI :
* MENAIKKAN TEMP. FEEDWATER SEBELUM MASUK
KEDALAM STEAM DRUM
* MENURUNKAN TEMP. GAS BUANG
* MENGHEMAT BAHAN BAKAR / MENAIKKAN EFISIENSI
BOILER
* MENGATUR DEW POINT PADA STACK/ AGAR TIDAK
MERUSAK LINGKUNGAN

CARA :
TERPASANG PADA SALURAN BUANG GAS SEBELUM
MASUK KE STACK / CEROBONG
LUAS BIDANG PERTUKARAN PANAS DIBESARKAN
DENGAN MEMASANG CINCIN / FIN
STEAM GENERATOR
BOILER BASICS
55
PEMANAS UDARA (AIR PREHEATER)
UDARA SEBELUM MASUK KEDALAM BOILER
DIPANASKAN TERLEBIH DAHULU UNTUK
MENINGKATKAN TEMP. SEKALIGUS UNTUK
MENINGKATKAN EFISIENSI
MENURUNKAN KERUGIAN PANAS AKIBAT
RADIASI DARI BADAN BOILER


CARA :
PADA BOILER BESAR (UTILITY DAN
INDUSTRIAL) DILENGKAPI DENGAN ALAT
KHUSUS UNTUK MENANGKAP PANAS DARI
GAS BUANG ( ROTARY TYPE)
PADA TYPLE BOILER KECIL (PACKAGE TYPE),
PANAS DIAMBIL DARI SALURAN UDARA /
RUANG DIANTARA DINDING LUAR - DALAM
TUBULAR AIR HEATER ( UDARA YANG
DIPANASKAN MENGALIR DIDALAM PIPA-2
YANG TERPASANG HORIZONTAL DIDALAM
SALURAN GAS BUANG. BENTUK PIPA MIRIP
PIPA-2 EKONOMIZER
HEAT-PIPE AIR HEATERS (Q-PIPE). TYPE INI
TIDAK ADA BAGIAN YANG BERGERAK
Q - PIPE HEATER
BOILER BASICS
56
BEBERAPA TYPE ALAT PEMANAS UDARA PEMBAKARAN ( AI R HEATER )
UDARA
DINGIN
GAS PANAS
GAS DINGIN
DAMPER
BOILER BASICS
57
HOT END ELEMENT ( MILD STEEL )
INTERMEDIATE ELEMENT
COLD END ELEMENT.
TEMP MAX. 74

0
C DENGAN PULVERIZED
COAL atau 66
0
C (OIL / NATURAL GAS).
MATL : STAINLESS STEEL
UNTUK PERTIMBANGAN EKONOMIS, AH.
ELEMEM DIBUAT DALAM 3 SECTION
ELEMENT : HOT END, INTERMEDIATE DAN
COLD END ELEMENT
RPM = 1
AIR HEATER
TERPASANG DI UNIT
PLTU PAITON
AIR PREHEATERS
BOILER BASICS
2 TYPE :
1. BI - SECTOR ( UDARA ATMOSFER PLUS HOT FLUE
GAS SECTION )
2. TRI - SECTOR ( UDARA ATMOSFER PLUS
PRIMARY AIR SECTION UNTUK MILL PLUS
SECONDARY AIR SECTION UNTUK PEMBAKARAN
AIR LEAKAGE DARI AIR STREAM KE GAS STREAM :
1. RADIAL LEAKAGE, DIATASI DENGAN RADIAL
SEALING UPPER & LOWER
2. AXIAL LEAKAGE, DIATASI DENGAN AXIAL
SEALING
58
BOILER BASICS
AIR PREHEATERS
PERLENGKAPAN AIR PRREHEATERS :
1. SOOT BLOWER PADA COLD & HOT END ELEMEMT.
BEKERJA TIAP 8 JAM ( NORMAL SETTING) ATAU SESUAI PRESSURE DROP ( GASIN ) DAN
( GAS OUT ) ATAU BILA ADA SIGNAL DARI FLAME SCANNER.
A. PADA COLD END DENGAN SATURATED STEAM TEMP. 332
0
C ATAU SUPERHEATED
STEAM TEMP. 142
0
C. TEKANAN ( 12 - 14 ) kg/ Cm
2
)
B. PADA HOT END DENGAN SAT. STEAM ( TEMP. 301
0
C ATAU SUPERHEATED 152
0
C )
TEKANAN 9 kg / Cm
2
.
2. OFF-LINE WATER WASHING :
DILAKSANAN PQADA SAAT SHUT-DOWN DENGAN MEDIUM AIR BERSIH.
PERTIMBANGAN WASHING :
- FUEL QUALITY - OPERATING CONDITIONS
- DRYNESS OF SHOOTBLOWING MEDIUM - NATURE OF DEPOSIT
3. SENSOR
- FLAME SCANNER ( MEMONITOR SPARKS atau HOT SPOT ),
- LOW TEMP. SENSOR ( KEMUNGKINAN ELEMEN KOTOR ,
- LOW COOLING WATER FLOW,
- INFRA RED SENSOR HOT ( BEKERJA BILA TERDAPAT HOT SPOT DENGAN TEMP
. 142
0
F ( 61

0
C )
- PRESSURE PROBE DI HOT GAS INTAKE DAN DI COLD GAS OUTLET SIDE.
4. MOTOR DRIVE DENGAN RPM SESUAI TYPE SPECIFIC ( 1 - 2 ) RPM
59
BASKET ELEMENT
BILA SHUTDOWN DALAM JANGKA LAMA,
DISARANKAN AH. ELEMEN DILAPISI DENGAN ANTI
RUST :
- KENDALL
- KENCOAT 60
- TEXACO NO. 1052
- METAL PROTECTIVE OIL
- MOBIL - MOBILARAMA 245
- LOW FLASH POINT
BOILER BASICS
Air Heater LJUNGSTRUM
GAS SIDE EFFICIENCY :

EFISIENSI A.H =---------------------------------

T
DROP
=
TEMP. GAS INLET - TEMP. GAS OUTLET
T
HEAD
=
TEMP. GAS INLET - TEMP. UDARA KELUAR
GAS DROP TEMP
TEMPERATURE HEAD
PLAT ELEMEN
PENYIMPAN
PANAS.
60
BOILER BASICS
EFISIENSI = RENDEMEN = DAYA GUNA
EFISIENSI ADALAH PERBANDINGAN NILAI KEUNTUNGAN YANG BISA DIPEROLEH ( Rp DI
JUAL ) DENGAN DAYA YANG TERSEDIA ( Rp YANG DIBELI )
MAKIN TINGGI NILAI EFISIENSI, BOILER AKAN MAKIN HEMAT BAHAN BAKAR
EFISIENSI DINILAI TIDAK HANYA DARI SEGI PERHITUNGAN TEKNIS SAJA, TETAPI
JUGA DARI PERHITUNGAN EKONOMINYA

= EFFISIENSI =
INPUT - OUTPUT
INPUT
=
H1 - h2
INPUT
INPUT = TOTAL ENERGY YANG DIBERIKAN KEPADA SYSTEM.
OUTPUT = INPUT -- SEMUA KERUGIAN.
BESARNYA KERUGIAN TERGANTUNG PADA KONDISI TEKNIS UNIT, PADA POLA
PENGOPERASIAN, PADA USIA UNIT DAN KOMPONENNYA.
KERUGIAN DALAM BOILER a.l PANAS HILANG, PEMBAKARAN TIDAK
SEMPURNA, KEBOCORAN GAS / UAP / AIR, PIPA BOILER YANG KOTOR PADA
SISI GAS DAN / ATAU SISI AIR, DLL
=
t
1
- t
2

t
1

EFI SI ENSI BOI LER
61
BOILER BASICS
STEAM GENERATOR ENERGY FLOIW
SCAN DSS TRNG HAL 21
Heated Air to Furnace
Furnace
Wall (50%) &
SH (35-45%)
RH Economizer
Air Heater
Steam ke
HP Turbine
Steam ke
LP Turbine
Air from ID Fan
Energy Loss to Stack
(1 - 1,5 % )
5 - 15 %
KALOR HILANG / RADIASI
TGT.KAPASITAS, USIA DAN DESIGN
BOILER ( 1.5 - 2.5 % ).
CREDIT HEAT = ENERGY YANG
DISUPPLY DARI LUAR SYSTEM BOILER
( LISTRIK PLN DLL )

BOILER
62
BOILER BASICS
BAHAN BAKAR GAS ( LNG / LPG )
+ TIDAK MEMERLUKAN POMPA DAN PERSIAPAN UNTUK LIGHT OFF
+ MEMERLUKAN PENGAWASAN YANG KETAT TERHADAP BAHAYA KEBOCORAN
+ SUPPLY UDARA HARUS TEPAT JUMLAHNYA UNTUK MENGHINDARI EXPLOSI
+ KANDUNGAN KARBON SANGAT RENDAH
+ DIUKUR DENGAN FLOWMETER
+ ANGKA NOX SANGAT RENDAH
UDARA PEMBAKARAN
STOICHIOMETRIC = JUMLAH UDARA / OXYGEN YANG DIBUTUHKAN UNTUK TEPAT
MEMBAKAR SEJUMLAH TERTENTU BH. BAKAR. TIDAK ADA SISA BH. BAKAR YANG
TIDAK TERBAKAR. TETAPI TIDAK ADA DISTRIBUSI PANAS KE SEKITARNYA. ( G1)
UDARA / OXYGEN TEORITIS = JUMLAH UDARA YANG DIPERLUKAN UNTUK
MEMBAKAR SEJUMLAH TERTENTU BH. BAKAR DAN MEMIMDAHKAN / MENGALIRKAN
PADA RUANG YANG MEMBATASI PROSES PEMBAKARAN . ( G2 )
EXCESS AIR = JUMLAH UDARA / OXYGEN YANG DIPERLUKAN UNTUK MEMBAKAR
SEJUMLAH BH. BAKAR SEKALIGUS MEMINDAHKAN / MENGALIRKAN PANAS YANG
DIHASILKANNYA KE TEMPAT LAIN. TERJADI DISTRIBUSI PANAS G3 = G1+ G2 + G ex )
OVER FIRE AIR ( OFA ) = UDARA YANG DISUPPLY KEPROSES PEMBAKARAN,
MEMAYUNGI GAS PEMBAKARAN BERFUNGSI UNTUK :



1 MENCEGAH TEMPERATURE SUPERHEATED STEAM MENCAPAI MAXIMUM,
2. MENGENDALIKAN EMISI GAS BUANG KE ATMOSFER TIDAK MERUSAK
LINGKUNGAN ( NOX & SOX )
63
KONSTRUKSI
BUCKSTAY
BUCKSTAY ADALAH KERANGKA YANG MEMPERKUAT BANGUNAN BOILER
KEARAH VERTIKAL - HORIZONTAL SEKALIGUS SEBAGAI PELINDUNG TERHADAP
IMPACT DARI LUAR
HARUS MAMPU MENGANTISIPASI EXPANSI KESEMUA ARAH
MAMPU MENGANTISIPASI KEMUNGKINAN EXPLOSI, IMPLOSI DAN GEO SEISMIC
BOILER BASICS
64
BOILER BASICS
STEEL STRUCTURE
( KERANGKA PENGUAT)
TERGANTUNG DESIGN BOILER
BOTTOM SUPPORT
BOILER DI BERDIRI PADA FONDASI
DIATAS TANAH
PACKAGE BOILER KECIL S / D BESAR

TOP SUPPORT
BOILER DI BERDIRI DENGAN
MENGGANTUNG PADA PILAR-PILAR
BAJA YANG SANGAT KUAT
MENGHEMAT AREAL TANAH
ANTI GEMPA dan FLEXIBLE TERHADAP
PEROBAHAN EXPANSI PADA
FLEXIBLE TERHADAP PEROBAHAN /
PERGESERAN RELATIF ANTARA PIPA-2
DENGAN KONSTRUKSI BOILER
UNTUK BOILER BESAR / RAKSASA
BOILER DENGAN TOP SUPPORT
STEEL STRUCTURE
SEBAGAI TOP
SUPPORT
PRESSURE PARTS
TERPASANG
MENGGANTUNG
65
BOILER BASICS
CONTRACT DATA SHEET
DATA YANG MENYEBUTKAN KEMAMPUAN, SPESIFIKASI TEKNIS DAN DATA
SESUAI PERHITUNGAN DESIGN. CDS DITERBITKAN OLEH PABRIK PEMBUAT
BOILER
SANGAT BERGUNA PADA SAAT PERFORMANCE TEST, SEBAGAI PEDOMAN
DALAM PELAKSANAAN KALIBRASI UNIT BOILER SETELAH SELESAI
PELAKSANAAN PEMELIHARAAN SEBAGAI DATA PEMBANDING,
PEMELIHARAAN DAN PENGUKURAN DAYA / EFISIENSI SECARA BERKALA
CONTRACT DATA SHEET HARUS DIKETAHUI PARA OPERATOR UNTUK
MENGETAHUI APAKAH UNIT BOILER YANG DIOPERASIKAN SESUAI DENGAN
KAPASITAS DESIGN. MANUFACTURER HARUS MENJAMIN KEBENARAN
PRODUKNYA.
MELIPUTI DATA KEMAMPUAN PER KOMPONEN, SUB KOMPONEN DAN
SECARA KESELURUHAN KEMAMPUAN UNIT
SETIAP KALI UNIT BOILER MENJALANI MAJOR OVERHAUL HARUS DISERTAI
COMMISSIONING DAN HASIL PERFORMANCE TEST HARUS SI COCOKKAN
DENGAN PERFORMANCE DALAM CONTRACT DATA SHEET..