Anda di halaman 1dari 65

BOOK 1

MODULE 1A
BOILER BASICS

1
BOILER BASICS

TUJUAN INSTRUKSIONAL UMUM


SETELAH SELESAI TRAINING INI, DIHARAPKAN PARA TRAINEE MAMPU
MENJELASKAN DENGAN BENAR :
• TAHAP PROSES PEROBAHAN ENERGI DALAM STEAM CYCLE POWER
• PRINSP- 2 KERJA BERBAGAI TYPE BOILER , MENJELASKAN NAMA DAN FUNGSI MASING-2
BAGIAN BOILER
• MENGENAL KONSTRUKSI DAN FUNGSI DARI SEMUA EQUIPMENT YANG TERPASANG
• MENGETAHUHI PRINSIP-2 CARA MENGOPERASIKAN BOILER DENGAN BENAR DENGAN
DIDASARI PENGERTIAN PROSES APA YANG TERJADI SETIAP OPERATOR MELAKUKAN
PERINTAH PEROBAHAN PADA MAIN CONTROL ROOM
• MAMPU MENGANALISA SEBAB DAN AKIBAT YANG AKAN TERJADI SETIAP TERJADI
PEROBAHAN UNJUK KERJA

TUJUAN INSTRUKSIONAL KHUSUS


SETELAH SELESAI TRAINING INI, DIHARAPKAN PARA PESERTA TRAINING
MAMPU MENJELASKAN DENGAN BENAR :

• JENIS dan FUNGSI KOMPONEN UTAMA DARI SUATU POWER PLANT


• PRINSIP – 2 PENGOPERASIAN BOILER DENGAN OUT PUT DAYA YANG OPTIMAL DAN
EFFISIENSI YANG MAKSIMAL ( ASPEK PENGOPERASIAN MENUNJANG PRODUKSI )
• CARA MENEKAN SERENDAH MUNGKIN OUTAGE dan MENJAGA KEHANDALAN / OUTPUT
( ENDURANCE ) SETINGGI MUNGKIN ( ASPEK PEMELIHARAAN MENUNJANG BEAYA OPERASI
SERENDAH MUNGKIN ) 2
BOILER BASICS
INDUSTRIAL UTILITY SUTET
PROCESS

SATURATED SUPERHEATED
STEAM STEAM

PROSES KONVERSI ENERGI :

FUEL (CHEMICAL ENERGY )


STEAM GENERATOR
+ WATER
STEAM POWER
/ BOILER / KETTEL TURBINE GENERATOR
STEAM ( KINETICAL ENERGY )
KONDENSOR

TURBINE ( MECHANICAL ENERGY )

TANK
ELECTRICAL ENERGY
CONDENSATING PUMP
FEEDING PUMP 3
STEAM CYCLE POWER
BOILER BASICS FUEL FIRING SYSTEMS PADA UTILITY BOILER TYPE ( PAITON )
St. DRUM
HP. SUPERHEATER
to St.TURBINE
To St. TURBINE
ECON
REHEATER
LP. SUPERHEATER DOWN COMER
from St.TURBINE

HEADER
ST. DRUM SPHT

EKONOMIZER
BURNER

BURNER BOILER BANK


BURNER WATER DRUM
COLLECTOR /
HEADER
FEED WATER

WATER DRUM

COAL FIRED STEAM OIL FIRED STEAM


GENERATOR UTILITY GENERATOR MARINE /
4
INDUSTRIAL
BOILER BASICS PROSES PEROBAHAN ENERGY

2. ENGINEERING FUNDAMENTALS

CHEMICAL ENERGY
( BAHAN BAKAR )
TERBAKAR
FURNACE

CALORIFIC ENERGY
( GAS PANAS )

BOILER

HEAT & KINETIC ENERGY


STEAM ( STEAM )
EKSPANSI
TURBINE

MECHANICAL ENERGY
( TURBIN BERPUTAR )
BOILER
GENERATOR

SATURATED STEAM ENERGY


PROCESS 5
ELECTRIC ENERGY ( STEAM )
BOILER BASICS 2. ENGINEERING FUNDAMENTALS

PROSES PEROBAHAN
AIR MENJADI UAP

b1 P1 P1
bX b2 PO
P2
c1
Daerah cair / steam
( campuran )

DAERAH
STEAM + STEAM
( KONDENSOR )

SETIAP PENURUNAN TEMP. SPHT 280C KE TURBINE


AKAN MENURUNKAN EFISIENSI SIKLUS. 1%

a- b = TEKANAN POMPA PENGISIAN


b - b1 = KENAIKAN TEMP. SAMPAI TITIK DIDIH ( water saturated ) PADA TEKANAN ( P1 )
b1- bX = % AIR MENDIDIH DALAM BENTUK CAIR
bX- b2 = % AIR MENDIDIH DALAM BENTUK STEAM
b2 - c = STEAM ( saturated ) TERUS DIPANASKAN , BEROBAH MENJADI SUPERHEATED
STEAM.
c - c1 = STEAM BEREXPANSI DIDALAM TURBINE
c1 - d = STEAM KELUAR DARI TURBINE dan MASUK KEDALAM KONDENSOR 6
d-a = PROSES KONDENSASI
BOILER BASICS WATER TO STEAM CONVERSION ( LANJUTAN )
6. PERCOBAAN DI ULANG KEMBALI DENGAN AIR 1 ( SATU ) KILOGRAM, TETAPI TEKANAN DINAIKKAN
MENJADI ( P2 ). SEMUA FASE FISIK TSB AKAN TERJADI BERULANG. TETAPI TERJADI PADA TEMPERATUR
YANG LEBIH TINGGI
7. TITIK-2 DIMANA AIR MULAI MENGUAP, DINAMAKAN GARIS BATAS BAWAH.
TITIK-2 DIMANA AIR BEROBAH MENJADI UAP JENUH, DINAMAKAN GARIS ( X ).
TITIK-2 DIMANA UAP JENUH BEROBAH MENJADI UAP KERING, DINAMAKAN GARIS BATAS ATAS.
8. BILA PANAS TERUS DIBERIKAN KEPADA AIR, SIFAT UAP BEROBAH MENJADI UAP PANAS LANJUT (
SUPERHEATED STEAM ). SIFAT-2 DAN HUKUM FISIK BERLAKU SEPERTI HUKUM GAS SEMPURNA
9. - GARIS ( a ) DINAMAKAN GARIS BATAS BAWAH. YAITU TITIK DIMANA AIR MULAI BEROBAH MENJA -
DI STEAM
- GARIS 1-2-3-4-5 DINAMAKAN ISOBAR ( GARIS YANG MENGHUBUNGKAN TITIK-2 DENGAN TEKANAN
YANG SAMA )
- GARIS ( X ) ATAU (C) DINAMAKAN GARIS KONDISI STEAM. MIS. (X = 65 ), BERARTI SEMUA TITIK
SEPANJANG GARIS TSB. MEMPUNYAI KANDUNGAN STEAM 65% DAN AIR 35 %
- GARIS (C) DINAMAKAN GARIS BATAS ATAS. BERARTI SEMUA TITIK SEPANJANG GARIS TSB.
BESARNYA X = 100. BERARTI BILA TEMP. DITURUNKAN, STEAM MULAI BERKONDENSASI.
BILA TEMP. DINAIKKAN, STEAM MULAI BEROBAH MENJADI SUPERHEATED.
- GARIS (d) TEMPAT KEDUDUKAN TITIK YANG MENGANDUNG KALOR YANG SAMA. DINAMAKAN
GARIS ISOTHROPIS

KESIMPULAN
1. AIR AKAN MENDIDIH PADA TEMPERATUR YANG LEBIH TINGGI BILA TEKANAN DINAIKKAN
2. MAKIN TINGGI TEKANAN DAN MAKIN TINGGI TEMPERATURE, STEAM AKAN MENGANDUNG
JUMLAH KALORI YANG LEBIH BESAR PULA.. KANDUNGAN KALOR / PANAS PADA SEPANJANG
GARIS ( d ) YANG SAMA MENGANDUNG JUMLAH PANAS YANG SAMA PULA.
3. TITIK K ( = KRITIS ) ADALAH KEADAAN DIMANA FLUIDA ( AIR / STEAM ) MEMPUNYAI SIFAT FISIK
7
YANG SAMA.
BOILER BASICS DIAGRAM MOLLIER’S [ pada boiler conventional ]
SENSIBLE HEAT
• PANAS YANG DIPERLUKAN
UNTUK MENAIKKAN
TEMPERATURE . MIS. DARI AIR
SAMPAI AIR MENDIDIH
• PROSES TERJADI SEPANJANG
GARIS BATAS BAWAH ( GARIS
WATER SATURATED )

X=30%

LATENT HEAT
• PANAS YANG DIPERLUKAN UNTUK
P = PRESSURE MEROBAH KEADAAN AIR  STEAM
PADA TEMPERATURE KONSTAN.
X=30% 30% STEAM + 70% WATER
• PROSES BERLANGSUNG DI
DAERAH CAMPURAN ( WATER -
STEAM ) 8
BOILER BASICS 2. ENGINEERING FUNDAMENTALS

BASIC DIAGRAM of BOILER

Boiler
STEAM
WATER
STEAM - WATER SYSTEM
BLOWDOWN
FUEL FLUE GAS
CAMPURAN HEAT
UDARA &
FURNACE TRANSFER
AIR FUEL SURFACE
ASH

Carbon Monoxida (CO)


Hydrogen ( H2) Carbon Dioxida ( CO2 )
Carbon ( C) FUEL FLUE GAS Oxygen ( O2 )
Sulphur ( S) Nitrogen (N2)
Nitrogen ( N2 ) Boiler Nitrous oxides (NOX )
Oxygen ( O2 ) Sulphur Oxides ( SOX )
Water ( H2O) Hydropgen ( H2 )
Air ASH Aldehydes
Uap Air.

Nitrogen ( N2 )
Oxygen ( O2 ) Ash Mineral
Water ( H2O) Carbon 9
Etc
BOILER BASICS 2. ENGINEERING FUNDAMENTALS
ENERGY BALANCE - HEAT BALANCE
STEAM

- ATOMIZING AIR ( POTENTIAL & KINETIC • TOTAL BTU ( TERMASUK KINETIC


ENERGY ) RADIASI [ 2.5% ] ENERGY )

- ATOMIZING STEAM ( TOTAL ENERGY ) • FLUE GAS ( POTENTIAL ENERGY


UNBURN CHEMICAL LATENT
HEATS SENSIBLE HEAT
FUEL
- ( GRINDING POWER )
- CHEMICAL ENERGY
- SENSIBLE HEAT - FLUE GAS
LATENT HEAT
- POTENTIAL ENERGY - POTENTIAL ENERGY
- KINETIC ENERGY - KINETIC ENERGY
- UNBURNED CHEMICAL
- LATENT HEAT
- SENSIBLE HEAT
COMBUSTION AIR
- SENSIBLE HEAT
- LATENT HEAT - BLOWDOWN
POTENTIAL ENERGY
- KENETIC ENERGY ( FAN - SENSIBLE HEAT
POWER ) - LATEN T HEAT

FEEDWATER ASH
- TOTAL BTU
- KINETIC ENERGY - SOOTBLOWING STEAM
- POTENTIAL ENERGY - SENSIBLE HEAT IN ASH
( PUMP POWER ) - UNBURNED CARBON IN ASH10
BOILER BASICS SIKLUS RANKINE ( WATER - STEAM CYCLE )

• SEMUA KEADAAN WATER / STEAM DALAM BERBAGAI


KONDISI YANG BERBEDA DIPETAKAN DALAM
3 DIAGRAM MOLLIER ATAU T - s ( TEMPERATURE -
21 ENTHROPI) DIAGRAM ATAU DIAGRAM h-s
( ENTHALPY - ENTROPY )
Qin • DAERAH DISEBELAH KIRI GARIS BATAS BAWAH ( a )
4 DINAMAKAN DAERAH CAIR.
@ DAERAH YANG DIBATASI GARIS BATAS BAWAH dan
GARIS BATAS ATAS DINAMAKAN DAERAH CAMPURAN.
2
1 @ DAERAH SEBELAH KANAN GARIS BATAS ATAS ( c )
DINAMAKAN DAERAH PANAS LANJUT ( SUPER -
1
3 HEATED ).

TITIK KRITIS • DARI DIAGRAM MOLLIER, SEMUA DATA DIROBAH


MENJADI ANGKA-2, DISUSUN MENJADI DAFTAR UAP
( STEAM TABLE ) BERFUNGSI BILA KITA AKAN
MENGHITUNG DAYA BOILER ATAU TURBIN UAP.
X

1 - 2 = KENAIKAN TEMP. KARENA KERJA POMPA ( FW PUMP)


2 - 21 = KENAIKAN TEMP. KARENA PEMBAKARAN ( Q in )
4
2 21 - 3 = PROSES SATURATED STEAM MENJADI SUPERHEATED
STEAM
DAERAH
1 CAMPURAN 3 - 4 = TEMP. STEAM TURUN KARENA EXPANSI DIDALAM
WATER + STEAM TURBIN
4 - 1 = PROSES KONDENSASI DIDALAM KONDENSOR
11
X = 85% = STEAM 85 % + WATER 15 %
BOILER BASICS

BOILER TYPE INTRODUCTION TO BOILER

BOILER CAPACITY

BOILER EFFCIENCY

ANGKA PERBANDINGAN JUMLAH TENAGA THERMAL YANG


BERMANFAAT ( BERGUNA , BISA DIJUAL ) DENGAN SELURUH
TENAGA THERMAL YANG DIBERIKAN KE BOILER TSB ( HARGA BH.
BAKAR, TENAGA LISTRIK DARI LUAR / PLN, HARGA FEEDWATER,
HARGA AIR PENDINGIN KONDENSOR, DLL YANG DIPEROLEH DARI
LUAR BOILER )

BESARNYA ( BERATNYA ) STEAM MAXIMAL YANG MAMPU DIHASILKAN OLEH BOILER


TSB DALAM TIAP JAM. MIS. BOILER CAPACITY 150 TPH.

• BERDASARKAN TUJUAN PENGGUNAAN ( UTILITY, INDUSTRIAL, KOMBINASI UTILITY - INDUSTRIAL


TOPPING SYSTEM DAN BOTTOMING SYSTEM )
• BERDASARKAN KONSTRUKSINYA ( PACKAGE BOILER DAN NON PACKAGE BOILER )
• BERDASARKAN SUMBER KALORI YANG DIGUNAKAN ( KONVENSIONAL, HEAT RECOVERY,
KOMBINASI KEDUANYA dan NUCLEAR )
• BERDASARKAN JENIS BH. BAKAR YANG DIGUNAKAN : PADAT ( BT. BARA, BAGGASE, MUNICIPAL
REFUSED, BY PRODUCT, WOOD/ CHIPS ), MINYAK ( RESIDU , DISTILATE OIL ), GASEOUS ( LNG,
NG, LPG , GEOTHERMAL )
• BERDASARKAN ISIAN PIPA ( PIPA API, PIPA AIR )
• BERDASARKAN BUILDING CONSTRUCTION : FOOT - STAND ( PRESSURE PARTS BERDIRI
DIATAS FONDASI / TANAH) dan HANGING-UP ( PRESSURE PARTS TERPASANG DENGAN 12
POSISI
TERGANTUNG PADA PILAR ). D.L.L.
BOILER BASICS
LANGKAH-2 UNTUK MENDAPATKAN ENERGY
YANG OPTIMUM DALAM DESIGN
MENENTUKAN JENIS
SUMBER ENERGY
MEMILIH EQUIPMENT
COAL UNTUK KONVERSI
MEMILIH SYSTEM
TRANSPORT ENERGY
MENENTUKAN
WOOD ENERGY
PROSES / WATER TUBE BOILER
BESARNYA STEAM
WASTES
KEBUTUHAN
STEAM HEAT RECOVERY
RUANG BOILER
OIL
PERTUKARAN
PANAS NATURAL GAS STEAM
ELECTRIC BOILER
HI-TEMP. WASTE GAS

ELECTRICITY

BERDASARKAN TUJUAN PENGGUNAAN BOILER ( STEAM GENERATOR )


1. UTILITY STEAM GENERATOR. STEAM YANG DIPRODUKSI KHUSUS UNTUK PEMBANGKIT TENAGA
LISTRIK
2. INDUSTRIAL STEAM GENERATOR. STEAM YANG DIPRODUKSI SELURUHNYA UNTUK PROSES
INDUSTRI
3. COMBINED STEAM COGENERATION :
A. TOP COGENERATION. SEBAGIAN BESAR STEAM YANG DIPRODUKSI UNTUK PEMBANGKIT
TENAGA LISTRIK. SISANYAN UNTUK PROSES INDUSTRI.
13
B. BOTTOM COGENERATUION SEBAGIAN BESAR PRODUKS STEAM UNTUK PROSES INDUSTRI.
SISANYA UNTUK PEMBANGKIT TENAGA LISTRIK.
BOILER BASICS BERBAGAI MODEL BOILER
TYPE PACKAGE DAN PENGGUNAANNYA

“ D-TYPE “ PACKAGE BOILER


UTILITY - INDUSTRIAL

“ MARINE “ V2M8 DENGAN U -


LOOP SUPERHEATER. TOP-FIRED
BURNER

“D” -TYPE PACKAGE BOILER


UTILITY - INDUSTRIAL “ MARINE “ CE-SM.
Tekanan 60 Kg/Cm2. Kap. 70T/hr

“ D-TYPE “ PACKAGE
BOILER - INDUSTRIAL

14
“A” - TYPE
MARINE PACKAGE BOILER
BOILER BASICS
• STEAM YANG DIHASILKAN
WATER TUBE BOILER
WATER TUBE BOILER TEKANAN RENDAH (1- 2.5 kg/ cm2
DENGAN FIRE TUBES ), TEMP. RENDAH ( 40 - 100 0C )
DAN BASAH
TYPE DRY BACK
• PENGGUNAAN KHUSUS
• FW TIDAK HARUS DIMURNI KAN
( TREATMENT )
• PIPA API DENGAN UK. TEBAL
• PADA FIRE DRUM BENTUK DRUM
BERGELOMBANG
• COMBUSTION AIR SEKALIGUS
BERFUNGSI SEBAGAI FORCED
WATER TUBE BOILER
DRAFT FAN
DENGAN FIRE DRUM
TYPE WET BACK

“ FIRE TUBE “ Scotch Marine & Industrial 15


Tekanan 21 Kg/Cm2, Spreader Stoker
BOILER BASICS PACKAGE BOILER TYPE “ D “

MARINE BOILERS

DINDING API
• BENTUK / UKURAN KOMPAK ( KECIL, DAYA
= REGENERATIVE OPTIMAL )

DINDING LUAR
• SIRKULASI NATURAL
GAS = ISOLASI RADIASI
• PACKAGE [ DINDING] BOILER TERDIRI DARI 2
LAPIS. DIANTARA INNER DAN OUTER WALL
DILEWATI UDARA PEMBAKARAN. UDARA
PEMBAKARAN TSB. BERFUNGSI REGENERATIF
( PRE HEATER ) dan SEBAGAI ISOLASI RADIASI
PANAS
• PRESSURE dan TEMPERATURE DIBATASI [ 25 - 35 ]
Kg / Cm2 / DIBAWAH 300 0C.
16
• RESPONSIF TERHADAP PEROBAHAN BEBAN
BOILER BASICS PACKAGE BOILER TYPE “ D “
STEAM
DRUM
SPHT

BOILER
BANK

FURNACE

BAFFLE

COMBUSTOR

WATER
DRUM

VU- 60 BOILER
PACKAGE BOILER TYPE “ D “ BABCOCK WILCOX • UNTUK INDUSTRIAL / UTILITY KECIL / COMBINED
• UNTUK INDUSTRIAL / UTILITY KECIL / COMBINED TOP / BOTTOM
TOP / BOTTOM • PRESSURE SESUAI TUJUAN PENGGUNAAN
• PRESSURE SESUAI TUJUAN PENGGUNAAN • NATURAL CIRCULATION
17
• NATURAL CIRCULATION • BH. BAKAR GAS / MINYAK
BOILER BASICS STEAM GENERATOR DENGAN Bh. BAKAR REFUSED dan BATU
BARA KWALITAS RENDAH.
STEAM
DRUM

COAL
SILO

REFUSE CHARGING
HOPPER

GAS
OUTLET
FEEDER

PLUNGER
ASH
EXTRACTRO
UNDERGRATE AIR

REFUSE - TO - ENERGY BOILER 55 MW CIRCULATING FLUIDIZED - BED


DENGAN BH. BAKAR SISA BUANGAN COMBUSTION UNIT for LOW VOLATILE
( AMPAS TEBU / BAGGASE ) BITUMINOUS COAL ( BATUBARA QUALITAS
1000 TON / DAY RENDAH )
18
INDUSTRI GULA TEBU
BOILER BASICS
HEAT RECOVERY STEAM GENERATOR ( HRSG )]

• BOILER DENGAN SUMBER PEMANASAN DARI GAS


BUANG DARI SUMBER LAIN ( GAS TURBINE )
• NON ADDITIONAL FIRING dan ADDITIONAL FIRING
• SINGLE STEAM DRUM, DOUBLE STEAM DRUM ( LP -
HP ), TRIPLE STEAM DRUM ( LP - IP - HP )
• SELANJUTNYA DIBAHAS KHUSUS PADA MODULE 1B
HRSG

BOILER SEGMENT
PADA HRSG
19
BOILER BASICS DIAGRAM PEMBANGKIT TENAGA UAP
TYPE UTILITY / INDUSTRIAL SUPERHEATED
STEAM UNTUK
UDARA SATURATED STEAM UTILITY
PEMBAKARAN UNTUK INDUSTRIAL
PROCCESS

BLR BANK
WALL TUBES

FURNACE
BH. BAKAR:
OIL /
GASEOUS

SUPERHEATER
SATURATED STEAM
• STEAM YANG MASIH MENGANDUNG X % WATER DAN Y % STEAM
• BERFUNGSI UNTUK PROSES [ INDUSTRI ]
• TEMPERATURE dan PRESSURE RELATIF LEBIH RENDAH

SUPERHEATED STEAM
• STEAM YANG MENGANDUNG( 0% WATER) dan (100% SUPERHEATED STEAM)
• BERFUNGSI UNTUK MENGGERAKKAN STEAM TURBINE
20
• TEMPERATURE DAN PRESSURE TINGGI ( DIATAS 460 0C / DIATAS 50 KG / Cm 2 ).
BOILER BASICS
DIAGRAM PEMBANGKIT TENAGA UAP TYPE UTILITY

4 UDARA 8
INLET

Pre heater

Precipitator
6
5 STEAM
GENERATOR

7 3 FURNACE

ECONOMIZER
ST.
TURBINE

1 2

CONDENSOR
Pulverizer 21
13
BOILER BASICS SIRKULASI PAKSA ( LANJUTAN )

PEMBANGKIT TENAGA LISTRIK


PLN UNIT #1 & #2 PAITON
• KAPASITAS 400 MW.
• TYPE CC - PP ( Controlled
Circulation Power Plant )
DILENGKAPI DENGAN BWCP
= Boiler Water Circulation Pump )
COAL • (STEAM PRESS. 225 Kg / Cm2
• STEAM TEMP. : 540 0 C
• FUEL : OIL ( SOLAR ) UNTUK
PERFECT
BURNING ZONE PEMBAKARAN AWAL , COAL
UNTUK NORMAL OPERATION ,
REBURNING ZONE dan GAS SEBAGAI
COAL ALTERNATIVE.
NOZZLE
INITIAL
COAL BURNING ZONE AIR HEATER
FEEDER
FLUE GAS

AIR FAN

22

PULVERIZER
BOILER BASICS SCHEMATIC OF COAL FIRED UTILITY POWER PLANT

STACK
AIR HEATER
PRECIPITATOR SO2 SCRUBBER
BOILER

ST. TURBINES

INDUCED DRIVE
FAN
FORCED DRIVE FAN

PRIMARY FAN

KONDENSOR

H.P. WATER COAL FEEDER


PREHEATERS

I.P. WATER
PREHEATERS

L.P. WATER
PREHEATERS COAL PULVERIZER BATUBARA

WATER TO BOILER
23
BOILER BASICS
SYSTEMS
WATER - STEAM CIRCUTS TANK

WATER

ECONOMIZER

SATURATED LP/ LT
STEAM STEAM PROCESS

STEAM DRUM
LP / LT DOWN
LP/ LT
SUPERHEATED COMER
STEAM PROCESS
STEAM
WALL
TUBES
HP / HT
SUPERHEATED
STEAM

DOWN FURNACE
STEAM COMER
TURBINE
BOILER
BANK

WATER
KONDENSOR DRUM

SWEET
WATER 24
BLOW DOWN SYSTEM
BOILER BASICS SYTEM TEKANAN PEMBAKARAN DIDALAM FURNACE

1. FORCED DRAFT SYSTEM


2. INDUCED DRAFT SYSTEM

FD FAN
1. FORCED DRAFT SYSTEM
25
BOILER BASICS

INDUCED DRAFT SYSTEM

MUATAN (
-)
FABRIC DENGAN
PRECIPITATOR
MUATAN ( + )
AIR
HEATER

ASH
HOPER

ASH HOPERS

ID FAN

AIR INLET

FD FAN
26
BOILER BASICS

2. JENIS SIRKULASI WATER-STEAM


DIDALAM BOILER

SIRKULASI ALAMI
- NATURAL CIRCULATION
- THERMO - SYMPHONIC

 SIRKULASI TERJADI KARENA BEDA


LEBIH
GRAVITASI AIR PANAS - DINGIN
PANAS
LEBIH  TIDAK MENGGUNAKAN POMPA
DINGIN  DIAMETER PIPA BOILER LEBIH BESAR
DARIPADA BOILER DENGAN SIRKULASI
PAKSA
 KAPASITAS BOILER LEBIH RENDAH
 START - UP LEBIH LAMA
 PERBANDINGAN SIRKULASI LEBIH
RENDAH DIBANDINGKAN DENGAN
SIRKULASI PAKSA.
 TAHANAN ALIRAN : GESEKAN ANTARA
AIR - PIPA, AIR DEPOSIT, TITIK BELOK,
AIR - DRUM INTERNAL
 CIRCULATION RATIO RENDAH ( = BERAT
AIR MASUK KE STEAM GENERATED
TUBES / BERAT STEAM YANG
BOILER DENGAN SISTEM DIHASILKAN STEAM GENERATED TUBES
SIRKULASI ALAMI YANG MASUK KE STEAM DRUM ) 27
BOILER BASICS SIRKULASI ALAMI ( lanjutan )

BESARNYA TOTAL SIRKULASI SANGAT DITENTUKAN OKEH 4 FAKTOR :

1. TINGGI BOILER
2. BESAR TEKANAN KERJA.
3. JUMLAH KALOR YANG DIBERIKAN
4. LUAS PENAMPANG PIPA YANG DILEWATI WATER dan WATER-STEAM.
1. MAKIN TINGGI / BESAR DIMENSI BOILER, MAKIN BESAR BEDA TEKANAN
BAGIAN YANG DIPANASI DAN BAGIAN YANG TIDAK DIPANASI
2. MAKIN TINGGI TEKANAN KERJA, MAKIN TINGGI KEPADATAN ( DENSITY )
WATER dan WATER-STEAM. BERARTI MENURUNKAN BEDA BAGIAN YANG
DIPANASI DENGAN BAGIAN YANG TIDAK DIPANASI.
3. MAKIN TINGGI KONSUMSI BH. BAKAR, MAKIN TINGGI STEAM YANG
DIPRODUKSI dan MAKIN RENDAH KEPADATAN WATER-STEAM. BERARTI
MENAIKKAN KECEPATAN SIRKULASI.
4. MAKIN BESAR LUAS PENAMPANG PIPA, MAKIN TINGGI KEPADATAN
SIRKULASI.
NOTE : PADA NATURAL CIRCULATION, UNTUK MENGHASILKAN [ X ] Kg
SATUAN BERAT STEAM, DIPERLUKAN SIRKULASI WATER
( 3 - 15 ) X
28
BOILER BASICS
CIRCULATION SYSTEM

SIRKULASI PAKSA ( FORCED DRIVE /


CONTROLLED CIRCULATION )
• AIR DIPAKSA MENGALIR DENGAN
MENGGUNAKAN POMPA SIRKULASI
( BWCP )
W • KAPASITAS PRODUKSI UAP LEBIH TINGGI
Cr = DAN LEBIH CEPAT ( 1.8 JUTA KG / JAM )
W S
S • START- UP LEBIH SINGKAT, SUHU AIR - UAP
SERAGAM, EXPANSI SEMUA BAGIAN BOILER
BERSAMAAN
• DIFFERENTIAL PRESSURE DAPAT DIMONI -
TOR ANTARA HISAP dan TEKAN SEBELUM
WATER MASUK KE STEAM RISER. DARI SINI
BERFUNGSI JUGA UNTUK MENGETAHUI
ADANYA PEMBENTUKAN DEPOSIT.
• DIAMETER PIPA - PIPA BOILER LEBIH KECIL,
LUAS PERMUKAAN BIDANG PERTUKARAN
PANAS LEBIH BESAR
POMPA • INSTALASI MENJADI LEBIH RUMIT KARENA
SIRKULASI ADANYA POMPA SIRKULASI
• PERBANDINGAN SIRKULASI :
Cr ( Ratio of Circulation ) = PERBANDINGAN
Boiler dengan sirkulasi paksa ORIFICE AIR TURUN MELALUI DOWNCOMER DENGAN
STEAM YANG MENINGGALKAN AIR DIDALAM
FUNGSI ORIFICE : STEAM GENERATOR TUBES
- MEMBUAT PRESSURE DROP
- MENGUKUR FLOW 29
- MENGATUR FLOW BALANCE
BOILER BASICS
SIRKULASI PAKSA ( LANJUTAN )

• PEMISAHAN WATER-STEAM DIDALAM STEAM DRUM MEMERLUKAN PERHITUNGAN DESIGN


LEBIH RUMIT. PEMISAHAN MENJADI INTENSIF DENGAN TURBO SEPARATOR. DENGAN TURBO
SEPARATOR, UKURAN STEAM DRUM MENJADI LEBIH KECIL.
• BILA BOILER DIDESIGNED UNTUK BEKERJA PADA TEKANAN KRITIS ( > 3208 psi / 221 bar)
DIMANA WATER DALAM WAKTU SANGAT SINGKAT BEROBAH MENJADI STEAM, UKURAN DRUM
MENJADI LEBIH KECIL LAGI. BAHKAN TIDAK DIPERLUKAN STEAM DRUM LAGI. KONDISI INI
DIKENAL DENGAN “ONCE-THROUGH CIRCULATION “.

CIRCULATION RATIO

ADALAH PERBANDINGAN ANTARA BERAT WATER YANG MASUK KE DOWNCOMER ( W ) DENGAN


BERAT STEAM DIDALAM CAMPURAN WATER-STEAM YANG MENINGGALKAN STEAM RISER
TUBES ( S ).

LOW LOAD CIRCULATION RATIO

ADALAH PERBANDINGAN ANTARA SIRKULASI WATER (W ) DENBGAN STEAM ( S ) BERDASARKAN


BEDA TEMPERATURE ( THERMAL HEAD ) YANG SELANJUTNYA TERGANTUNG PADA TEKANAN
BOILER, JUMLAH WATER YANG MASUK KE DOWNCOMER AKAN MENINGKAT SEMENTARA LOAD
BERKURANG.
KESIMPULAN :
BILA BEBAN BOILER KURANG DARI 50% MCR ( MAXIMUM CONTINUOS RATE = KAPASITAS MAX.
YANG KONTINYU ), PERBANDINGAN SIRKULASI AKAN SEMAKIN BESAR. EFFISIENSI AKAN
30
MENJADI RENDAH.
BOILER BASICS

FLOW BOILING 1. ADA HUBUNGAN YANG ERAT ANTARA GRAVITY,


MATERIAL DAN MEKANISME PERPINDAHAN
PANAS
2. AIR MASUK KEDALAM PIPA DENGAN TEMP. SUB
BOILED. MELALUI PROSES KONVEKSI, PANAS
DISERAP DARI PIPA KE AIR
3. AIR MULAI SUBCOOLED BOILING DAN BUBBLE
FLOW ( GELEMBUNG ). TEMP. TERUS NAIK
MENCAPAI SATURATION TEMP. DAN MULAI
TIMBUL NUCLEATE BOILING.
4. DI DAERAH INI DIMULAINYA PROSES PERO-
BAHAN WATER - STEAM ( BUBBLE -
INTERMEDIATE DAN ANNULAR )
5. PERPINDAHAN PANAS TERUS BERLANJUT,
DIMANA TERCAPAI KEADAAN ANNULAR FLOW
YANG SANGAT TIPIS ( NUCLEATE ). MULAI DI
DAERAH INI PROSES PERPINDAHAN PANAS
SECARA KONDUKSI DAN KONVEKSI
( CONVECTIVE BOILING ) . MULAI TIMBUL CHF
( CRITICAL HEAT FLUX ).
6. DI DAERAH CONVECTIVE BOILING KENAIKAN
TEMP. SANGAT PESAT dan WATER BEROBAH
MENJADI SATURATED STEAM.
• APABILA PROSES INI BERLANGSUNG DALAM
WAKTU YANG SANGAT SINGKAT DAN SERING
TERJADI, BERAKIBAT PIPA CEPAT RUSAK . 31
BOILER BASICS
DNB = DEPARTURE from NUCLEATE BOILING

• ADALAH KEADAAN ( BEBERAPA SAAT BERSAMAAN


TERJADINYA PEROBAHAN LOAD YANG BESAR /
MENDADAK ) DIMANA PANAS YANG DIBERIKAN
( DARI PEMBAKARAN ) MELEBIHI JUMLAH WATER –
STEAM DIDALAM STEAM RISER.
• TERBENTUK KANTONG STEAM PADA DAERAH YANG
DAERAH YANG POTENSIAL LUAS DIDALAM PIPA, MEMBENTUK LAPISAN TIPIS
( ANNULAR ) YANG MENGHAMBAT PROSES
PERTUKARAN PANAS DARI GAS KE PIPA KE WATER /
CEPAT RUSAK

STEAM.
• APABILA KEADAAN DNB INI BERLANGSUNG CUKUP
LAMA ATAU SERING TERJADI, PIPA AKAN CEPAT
RUSAK
• AKIBAT YANG TIMBUL :
- OVERHEATED TUBE FAILURES
- PEMBENTUKAN DEPOSIT PADA SISI AIR
- SULIT MENGATUR TINGGI AIR DALAM DRUM
- WATER CARRY AKIBAT TURBULENSI YANG BESAR
• DAPAT DIHINDARI DENGAN MENAMBAH BEBAN
BOILER DENGAN BERTAHAP (SEDIKIT DEMI SEDIKIT )
32
BOILER BASICS
HEAT TRANSFER ( PERPINDAHAN PANAS )

GAS • DIDALAM PROSES PERTUKARAN PANAS DIDALAM


PANAS DEPOSIT BOILER TERJADI TIGA PROSES ( KONDUKSI,
KONVEKSI DAN RADIASI ) SECARA BERSAMAAN .
• BESAR / KECEPATAN PERTUKARAN PANAS

WATER
 RUGI TERGANTUNG PADA LUAS BIANG, KONDISI
PERMUKAAN BIDANG ( HALUS / KASAR, BERSIH /
KOTOR, KILAP / BURAM, TERANG / GELAP ), JARAK
SUMBER PANAS KE BIDANG PENERIMA PANAS,
KECEPATAN ALIR DARI GAS DAN JENIS MATERIAL
YANG DIPANASI ( MURNI / BERLAPIS ).
JELAGA
PIPA
PENGARUH KETEBALAN JELAGA TERHADAP
PERTUKARAN PANAS

1/32 “ SOOT 1/16 “ SOOT 1/ 8 “ SOOT 3 / 16 “ SOOT


RUGI 9.5% RUGI 26.2 % RUGI 45,3 % RUGI 69 %
33
BOILER BASICS STEAM DRUM INTERNALS

Separator
Screen Dryer MENCEGAH AIR TITIK-2 MASUK
MENCEGAH PERCIKAN KE SALURAN STEAM. HANYA
AIR MASUK KE STEAM YANG LOLOS MASUK KE
SALURAN STEAM. SALURAN STEAM
STEAM LOLOS MASUK
KE SEPARATOR
TURBO SEPARATOR
BAFFLE PLATE MEMISAH STEAM DARI
UNTUK MEMBELOKKAN ARAH AIR DENGAN CARA
ALIRAN ( WATER + STEAM YANG SENTRIFUGAL. STEAM
PANAS ) TIDAK LANGSUNG ( RINGAN ) MASUK KE
BERCAMPUR DENGAN
SCREEN. AIR ( LEBIH
FEEDWATER YANG MASIH
BERAT ) JATUH KEMBALI
DINGIN STEAM + WATER KE AIR
TUBE RISER / STEAM
GENERATOR BAFFLE PLATE
UNTUK MENCEGAH FEED WATER (
WATER + STEAM DARI STEAM WATER DINGIN ) BERCAMPUR LANGSUNG
RISER ( WATER WALL & BOILER DENGAN WATER DI DALAM DRUM (
BANK ) MASUK KEDALAM ST. PANAS )/ MENCEGAH THERMAL
DRUM. SCHOCK PADA DRUM METAL
BLOWDOWN
CHEMICAL LINE UNTUK MEMBUANG FEEDWATER DI
DALAM STEAM DRUM BILA KADAR
UNTUK MEMASUKKAN BH. KIMIA GARAM DIATAS BATAS MAX.
MENCEGAH PEMBENTUKAN
SCALES, SLUDGE, CORROSION DOWN COMER FEEDWATER INLET
UNTUK MENGALIRKAN FEEDWATER
SECARA PERIODIK DI SUPPLY KELUAR DARI ST. DRUM DAN UNTUK MENGISI FEEDWATER
UNTUK MENJAGA AGAR MASUK KE WATER DRUM DAN 34 TINGGI
KEDALAM ST. DRUM AGAR
FEEDWATER TETAP MURNI SELANJUTNYA MASUK WALL TUBES / GARIS SELALU KONSTAN.
BOILER BANK
BOILER BASICS
STEAM - WATER SEPARATION ( PEMISAHAN UAP - AIR )
FUNGSI ( TAMBAHAN ) STEAM DRUM
1. MENCAMPUR FW. DENGAN SATURATED WATER YANG
TER[PISAH DARI STEAM
2. MENGONTROL KOROSI DAN WATER TREATMENT ( BILA
DILENGKAPI )
3. MEMISAHKAN KONTAMINANT DAN RESIDUAL MOISTURE DARI
STEAM
4 MEMBUANG SEBAGIAN DARI FW. ( BLOWDOWN ) UNTUK
MENGATUR BOILER WATER CHEMISTRY DAN DEPOSITS
KERAS
5. MENGATUR JUMLAH AIR DALAM ST. DRUM UNTUK
MENGANTISIPASI PEROBAHAN LOAD BOILER DENGAN CEPAT.

FUNGSI ( UTAMA ) ST. DRUM


1. MEMISAH STEAM DARI SAT. WATER DENGAN EFEKTIF
2. MENCEGAH WATER DROPLETS CARRY OVER KEDALAM
SUPERHEATER TUBING KARENA THERMAL SCHOCK.
3. MENCEGAH SEKECIL MUNGKIN STEAM CARRY UNDER
KEDALAM WATER YANG RESIRKULASI KEDALAM
DOWNCOMERS.
4. MENCEGAH DEPOSIT/ SOLIDS ( SCALE ) CARRY OVER KE
SUPERHEATER DAN / ATAU KE TURBIN. SOLIDS ( SCALES )
TERBAWA BERSAMA FW ATAU SWEETWATER 35
( MAKEUP WATER ).
BOILER BASICS
TURBO CYCLONE

STEAM

WATER

TYPE “A “ TYPE “B “

• BEKERJA BERDASARKAN GERAK PUTAR DARI STEAM + WATER. KARENA GAYA SENTRIFUGAL,
WATER TERLEMPAR KEARAH LUAR, STEAM MENGALIR DI TENGAH TURBO CYCLONE.
• STEAM DITAHAN BAFFLE KEMBALI KE WATER. STEAM TETAP MENGALIR KEARAH ATAS.
• MENCEGAH WATER CARRYOVER, STEAM CARYYUNDER dan CARRY OVER OF SOLIDS.
• MENCEGAH WATER CARRY OVER DENGAN MEMASANG BAFFLE PLATES, SCRUBBER
ELEMENTS
• MENCEGAH STEAM CARRYUNDER DENGAN MEMASANG MANIFOLD BAFFLE PLATES. 36
BOILER BASICS
PENGARUH WATER CARRYOVER dan STEAM CARRYUNDER

MOISTURE CARRYOVER KEDALAM STEAM


• TERJADI SECARA BERTAHAP ( SEDIKIT DEMI SEDIKIT ) SAMPAI KE TITIK DIMANA SATURATED
WATER MENCAPAI MAX. DISUSUL WATER CARRYOVER SECARA MENDADAK.
• DIIKUTI DENGAN KENAIKAN WATER LEVEL SAMPAI TERJADI OVER FLOW ( MELIMPAH )
• SAMPAI TERJADI KENAIKAN STEAM QUALITY

STEAM CARRYUNDER KEDALAM WATER


• WATER LEVEL MENURUN
• INLET STEAM QUALITY TURUN

FAKTOR MEMPENGARUHI KECEPATAN PEMISAHAN WATER - STEAM


DESIGN FAKTOR FAKTOR PENGOPERASIAN
• PRESSURE • PRESSURE
• DIMENSI DRUM • BOILER LOAD ( STEAM FLOW )
• KECEPATAN PEMBENTUKAN STEAM • TYPE OF STEAM LOAD
• QUALITRAS INLET STEAM RATA-2 • CHEMICAL ANALYSIS PADA FW
• TYPE & KONSTRUKSI SEPARATORS • WATER LEVEL
• KONSTRUKSI EQUIPMENT FW SUPPLY &
STEAM DISCHARFED
• KONSTRUKSI DOWN COMER & RISER 37
CONNECTIONS TERHADAP DRUM
BOILER BASICS
STEAM DRUM CAPACITY
• VOLUME WATER dan VOLUME SATURATED STEAM HARUS
MAMPU MEMENUHI SETIAP PEROBAHAN LOAD (NAIK / TURUN)
DENGAN AMAN TERHADAP TURBINE dan AMAN TERHADAP
BOILER ( SUPERHEATER TUBES )
La • STEAM TIDAK TERBAWA ALIRAN WATER KE DOWN COMERS
• BILA STEAM LOAD BERTAMBAH DALAM WAKTU SANGAT
SINGKAT / MENDADAK dan DALAM JUMLAH BESAR,
Lb MENGAKIBATKAN KEADAAN SBB. :
- WATER LEVEL TURUN ( LB )
- TEKANAN STEAM TURUN
- VOLUME STEAM MENINGKAT
- QUALITAS STEAM TURUN ( % WATER DALAM STEAM NAIK )

OVERHEATED

 TIMBUL SWELL ( GELOMBANG BESAR KARENA TEKANAN TIBA - 2 BERKURANG, SEDANGKAN


TEKANAN FEED WATER PUMP KONSTAN ). AKIBAT LANGSUNG, WATER LEVEL SULIT DIBACA.
 BILA FIRING RATE TERLAMBAT, WATER LEVEL AKAN NAIK ( La ), VOLUME STEAM BERKURANG.
BILA BERLANJUT BISA MENYEBABKAN WATER CARRY OVER ATAU SUPPLY WATER
TERLAMBAT, WATER LEVEL TERUS TURUN MENCAPAI TUBE RISER. HAL INI SANGAT
BERBAHAYA KARENA MENGAKIBATKAN PIPA OVER HEATED
 DAN SEBALIK NYA BILA LOAD TIBA-2 BERKURANG DALAM JUMLAH BESAR.
 DI KENDALIKAN DENGAN 3 WAY CONTROLLED SYSTEM ( DRUM LEVEL - STEAM FLOW -
FEEDWATER FLOW ). 38
BOILER BASICS COMBUSTION SYSTEMS
FURNACE
SALURAN GAS DAN FLUEGAS DARI FURNACE
GAS & FLUEGAS CIRCUITS KE TITIK PEMBUANGAN KE ATMOSFER /
STACK.
COMBUSTOR / BURNER

COMBUSTION AIR ( PA & SA )

RUANG PEMBAKA - EMISSION EMISSION CONTROL


RAN YANG DIBA -
TASI DENGAN PIPA -
• MENGONTROL GAS YANG KELUAR DARI STACK TIDAK MENIMBULKAN
2 WATER / STEAM
PENCEMARAN TERHADAP LINGKUNGAN / POLUSI )
( WALL TUBE )
• BENTUK EMISI :
NOX, SOX, THERMAL, CHEMICAL , DEBU , RACUN,
• YANG DILINDUNGI :
MAKHLUK HIDUP, TANAMAN, BANGUNAN & ALAM

• FORCED DRAFT FAN ( FD FAN ) MENSUPPLY UDARA PEMBAKARAN


• INDUCED DRAFT FAN ( ID FAN ) MEMBUAT TEKANAN UDARA / GAS DIDALAM GAS DUCT
LEBIH RENDAH DARI TEKANAN ATMOSFER( MEMBANTU PROSES PEMBAKARAN
DENGAN BH. BAKAR BATUBARA.
• UDARA UNTUK PROSES PENGERINGAN BATU BARA / BAGASSE
• UDARA UNTUK TRANSPORTASI BAGASSE / PUVERIZED COAL DARI PULVERIZER KE
FURNACE

• MENSUPPLY BH. BAKAR KEDALAM FURNACE ( COAL NOZZLES , OIL GUNS, GAS NOZZLE )
• DAMPER ( PINTU UNTUK MENGATUR BESARNYA SUPPLY UDARA PEMBAKARAN ), SWIRLER MENGATUR AGAR
UDARA MASUK KEDALAM FURNACE DALAM BENTUK PUSARAN 39
BOILER BASICS
FURNACE DESIGN UNTUK UTILITY / INDUSTRIAL BOILER
FUEL FIRING SYSTEMS CYCLONE FURNACE ( 1940 )
CYCLONE FIRING ADALAH PROSES PEMBAKARAN
DENGAN MEMANFAATKAN GERAK UDARA
PEMBAKARAN ( SECONDARY AIR ) & FUEL
SECA RA TANGENTIAL AGAR MENCAPAI EFISIENSI
PEMBAKARAN MAXIMUM.
FUEL :
• OIL ( ATOMIZED )
• COAL ( PC = PULVERIZED COAL ). 70 % MELEWATI
200 MESH ( 74 MICRON ) SCREEN.
AIR DISTRIBUTION
• PRIMARY AIR ( PA ) BERFUNGSI UNTUK
MENGALIRKAN DAN SEKALIGUS MENGERINGKAN
PC DARI COAL MILL KE BURNER
• SECONDARY AIR (SA ) BERFUNGSI TERUTAMA
UNTUK LANGSUNG MEMBAKAR FUEL..
• TERTIARY AIR ( TA ) BERFUNGSI UNTUK PROSES
PEMBAKARAN AWAL, MENGALIR SEPANJANG
CYCLONE AXIS
BERDASARKAN KEUNTUNGAN :
1. EKONOMIS . PENYIAPAN FUEL MUDAH / MURAH
2. VOLUME FURNACE KECIL DENGAN MEMANFAATKAN GERAK CYCLONE
40
3. PEMBENTUKAN FOULING SANGAT RENDAH ( 15-30 ) % DARI FUEL ASH YANG MASUK KE
CONVECTION PASS DARI 80% FLUE GAS YANG LEWAT ( DENGAN BH. BAKAR COAL )
BOILER BASICS
OIL BURNER TYPE “ R “ ( ALSTOM “

WIND BOX AIR DAMPER


FURNACE SECONDARY AIR
WALL TUBE

BURNER PRIMARY AIR


THROAT
IGNITOR
TYPE “ R “ OIL BURNER

OIL GUN

OBSERVATION
HOLE

TYPE “ SV “ GAS BURNER

41
BOILER BASICS COAL FIRING SYSTEMS PADA UTILITY BOILER TYPE ( PAITON )
TANGENTIAL - FIRING WINDBOX
• TERPASANG PADA UTILITY / INDUSTRIAL
BOILER
• PRIMARY FUEL : COAL.
PRELIMINARY FIRING FUEL : OIL / SOLAR
MAIN / SUPPLEMENT FUEL : GASEOUS /
OIL.
• 27.5 0 TILT-UP ATAU 27.5 0 TILT-DOWN
UNTUK MENGATUR TEMP. SUPERHEATER
STEAM. START-UP PADA POSISI
HORIZONTAL
• START-UP DENGAN PEMBAKARAN OIL
GUN. SETELAH PANAS MERATA DAN TEMP.
FLUE GAS MENCAPAI MINIMAL UNTUK
PENGERINGAN PC. PEMBAKARAN DIAMBIL
ALIH OLEH COAL NOZZLE.
• BUKA / TU

• TUP DAMPER SESUAI BOILER LOAD.


• FLAME MONITOR DENGAN IFM ( ( IONIC FLAME MONITOR ) DAN MELALUI
DIGERAKKAN CONTROL DENGAN
DAMPER FSSS
DRIVE
( FURNACE SAFEGUARD SUPERVISORY SYSTEM ) MECHANISM.
• OFA ( OVER FIRE AIR ) : DISUPPLY DARI NOZZLE ELEVASI TERATAS. BERFUNGSI UNTUK
MENCEGAH TEMP. GAS MENCAPAI MAX ( THERMAL NOX ). Nox max. 0.45 lb / million Btu.
Panas yang dihasilkan
42
BOILER BASICS PENGATURAN TEMPERATURE PEMBAKARAN

• POSISI BURNER HORIZONTAL [ 00 ]


• TEMPERATURE SUPERHEATED • TEMP. SPHT STEAM
• UNTUK START- UP DAN BEBAN STEAM TERLALU TINGGI, TERLALU RENDAH, POSISI
NORMAL KONSTAN POSISI BURNER DITURUNKAN ( BURNER DINAIKKAN ( TILT-
• LIGHT-OFF AWAL DENGAN DENGAN TILT-DOWN ) [ -270 ] UP) [ +270 ]
BH. BAKAR MINYAK UNTUK [ ]
PEMANASAN WALL TUBES. • - TEMP. SPHT TURUN • - TEMP. SPHT NAIK
- TEMP. WATER CEPAT NAIK - TEMP. WATER TURUN
• TEMPERATURE AIR HEATER DARI PA
FAN CUKUP, BATU BARA MULAI - TETAPI TEMP SATURATED - TETAPI TEMP SATURATED
DIBAKAR STEAM TURUN STEAM NAIK
• TEMP. & TEKANAN STEAM SIAP • SETELAH STABIL, POSISI • SETELAH TEMP. STABIL,
43
DIOPERASIKAN. BURNER 00 POSISI BURNER 00
BOILER BASICS FURNACE DESIGN UNTUK UTILITY / INDUSTRIAL BOILER

FUEL FIRING SYSTEMS CYCLONE PATERN ( Dikenal sbg.LNCFS = Low Nox


Concentric Firing Systems )
1. HORIZONTALLY INTRODUCED
OFA 2. VERTICAL FLOW
1090 0C
3. OFA ( OVER FIRE AIR )

SPRAY PATERN
1427 0C
1. FIXED ANGLE
2. VARABLE ANGLE
FLAME MONITOR
IFM ( IONIC FLAME MONITOR = FLAME SCANNER )

22 0 25 0 WINDBOX

BENTUK NYALA
PEMBAKARAN

FUEL / COPAL

UDARA
PEMBAKARAN

OXYGEN RICH 44
BOILER BASICS
COAL FEEDER
[ MENSUPPLY COAL SESUAI BEBAN TURBINE )
WEIGHING MODULE

COAL ON BELT SENSOR

TAKE UP BELT SCRAPER


PULLEY

SEAL AIR
VALVE CLEANOUT CONVEYOR

• LOAD BOILER MEMBERI SIGNAL KE MOTOR PENGGERAK PULLEY , MENGATUR KECEPATAN PUTAR
• BERFUNGSI UNTUK MENIMBANG BERAT COAL YANG HARUS DI SUPPLY UNTUK DIBAKAR SESUAI LOAD
BOILER
• MAKIN BERAT BEBAN PULLEY, MAKIN RENDAH KECEPATAN PUTARNYA.. DAN SEBALIKNYA.

TURBINE LOAD
BOILER LOAD
SCALE CONTROL 45
MOTOR
BOILER BASICS PROSES PENANGAN BT. BARA

GRIND ABILITY

Ke Burner
50 grams

Sisa 0.025 grams


dengan mesh 30
49.975
Sisa 0725 grams
gram lolos
dengan mesh 50

Sisa 4.5 grams 49.25 gram


dengan mesh 100 lolos

Sisa 9.75 grams


dengan mesh 200 44.75 gram
lolos

SIAP DI DISTRIBUSI 35 gram


lolos
46
BOILER BASICS DSVC = DYNAMICALLY STAGE VARIABLE SPEED
( MODEL B&W )

2nd
STATIONARY
SECTION

1st
STATIONARY
SECTION
(CLASIFIER)

47
BOILER BASICS FURNACE DESIGN UNTUK UTILITY / INDUSTRIAL BOILER

FUEL FIRING SYSTEMS

• FLAME SCANNER DI “ BUNGKUS “


UDARA YANG BERFUNGSI SEBAGAI
COOLER.

FUEL • MENYUDUT KE TITIK FOCUS FLAME.


• SENSOR BERDASARKAN TEMP.
TERTINGGI DAN JUGA BERDASARKAN
WARNA NYALA ( ULTRA
VIOLET ).
AIR

OIL & GAS BURNERS


• BERFUNGSI SEBAGAI PRIMARY BURNER DAN /
SECONDARY ATAU AUXILIRY BURNER
GAS NOZZLE
• UDARA ( SECONDARY ) MASUK KE BURNER
MELALUI WHIRLING VANES . UDARA
( PRIMARY) MASUK LANGSUNG KE NOZZLE
• BH. BAKAR GAS MASUK BERSAMA SECONDARY 48
MAIN OIL BURNER
AIR
BOILER BASICS

SISTEM PEMBAKARAN BATUBARA


 BATU BARA HARUS DILEMBUTKAN ( PULVERIZED ) SEPERTI BENTUK
TEPUNG UNTUK MEMPERBESAR LUAS BIDANG HEX.
 PENGALIRAN SERBUK BATU BARA DENGAN MENGGUNAKAN UDARA
PEMBAKARAN YANG TELAH DIPANASKAN ( PRE-HEATED ) DI AIR
HEATER
 NILAI KALOR TIDAK TERLALU TINGGI
 % KARBON TINGGI, % KELEMBABAN TINGGI
 MUDAH MENDAPATKAN / MURAH HARGA, TIDAK PERLU TEMPAT
PENYIMPANAN KHUSUS
 SULIT TERBAKAR DAN BILA SUDAH TERBAKAR SULIT DIPADAMKAN
 MEMERLUKAN ALAT PEMBERSIH DEBU / ABU KHUSUS
( EP = ELECTRO PRECIPITATOR )
 HEATING VALUES BT.BARA 13. 335 Btu / lb,
MINYAK = 18. 538 Btu / lb, Natural gas = 23. 865 Btu / lb.

SISTEM PEMBAKARAN FUEL OIL


 OIL & NATURAL GAS = FOSSIL FUEL = RANGE : CRUDE OIL - DISTILATE OILS ( DIESEL , LIGHT
dan HEAVY RESIDUAL OILS ).
 HHV = 18.250 - 20. 000 Btu / Lb.
 AGAR MUDAH DAN CEPAT TERBAKAR, OIL HARUS DI “ ATOMIZED “. MAKIN MENDEKATI SIFAT
CRUDE OIL, OIL HARUS DIPANASKAN SEBELUM DI KABUTKAN ( ATOMIZED ).
 LAKUKAN TEST PENERIMAAN dan SEBELUM DIBAKAR ( % WATER, FLASH POINT, FIRE POINT,
VISCOSITY,
 FLASH POINT = TERBAKAR DENGAN SENDIRINYA KARENA TEMPERATURE RUANG = TITIK NYALA
-----------> UNTUK KEAMANAN PENYIMPANAN
FIRE POINT = TERBAKAR KARENA BERSENTUHAN DENGAN SUMBER PANAS ( MIS. BUSI ). OIL #4,
49
# 5 & # 6. VISCOSITY = KEKENTALAN. MAKIN TINGGI TEMP. , MAKIN ENCER. DIATAS TEMP.
0 0
250 F / 120 C STABIL ( CAIR KE GAS )
BOILER BASICS SIFAT-2 FOSSIL OIL ( NATURAL GAS )

GAS SISA
 SEBAGAI BH. BAKAR IDEAL ( % WATER KECIL, NO ASH, NO
SULFUR. NO PUMP, NO SCRABER ).
 TIDAK BERWARNA dan TIDAK BERBAU.
LPG
 LNG TERDIRI DARI BEBERAPA JENIS GAS LAIN YANG
BERBEDA ( CO2, N2, CH4, C2H6 ). HHV
BENZENE
ANTARA [ 843 - 1548 ] BILA % PROPANE dan ETHANE TINGGI
= 2000 Btu / Cu. Ft. RATA-2 = 1000 Btu / Cu. Ft.
AVGAS
 KEUNTUNGAN

AVTUR 1. UNTUK KAPASITAS YANG SAMA, BOILER DENGAN GAS


FIRED MEMPUNYAI DIMENSI KECIL DIBANDINGKAN
KEROSENE DENGAN YANG OIL / COAL FIRED.
2. TIDAK MEMERLUKAN TANGKI PENYIMPANAN.
SOLAR  KERUGIAN :
MINYAK
MENTAH 1. % HYDROGEN TINGGI --------> % WATER SETELAH PROSES
RESIDU PEMBAKARAN.
STEAM / HOT GAS 2. EFISIENSI BOILER RENDAH ( KALOR PEMBAKARAN
SEBAGIAN BESAR UNTUK MEROBAH WATER ( DALAM
STEAM F;LAME ) MENJADI VAPOR / STEAM.
COIL
3. [ O2, N2, CO2 ] TIDAK MENGHASILKAN KALORI PANAS.
LUMPUR  METHOD ANALYSIS : ANALISA KIMIA, INFRA RED
/ ASPAL / SPECTROMETRY, MASS SPETROMETRY dan GAS
SISA
CHROMATOGRAFY.

BASIC REFINERY PROCESS 50


BOILER BASICS SIFAT-2 FOSSIL ( OIL FUEL )
MAKIN KENTAL-  SEBAGAI HASIL CRACKING atau DISTILASI MINYAK MENTAH.
MAKIN GELAP-
MAKIN TINGGI  SIFAT – 2 FISIKA YANG HARUS DIPERTIMBANGKAN : VISKOSITAS, VOLATILITY
KARBON ( DAYA PENGUAPAN ), GRAVITY, POUR POINT ( TITIK TUANG ), FLASH POINT (
TITIK NYALA ), BURNING / IGNITION POINT ( TITIK TERBAKAR ), ACIDITY (
DERAJAT KEASAMAN ), % CARBON, RESIDU KARBON, % SULFUR, % ASH ,
AIR dan ENDAPAN, , NILAI KALOR ( HHV dan LHV ), CORROSIVENESS, 
SIFAT ALAMI Bh. BAKAR MENJADI PARAMETER DALAM MENDESIGN SEBUAH
BOILER ( BENTUK, KONFIGURSI PIPA-2, LUAS BIDANG PERTUKARAN PANAS
dan SISTEM PEMBAKARAN YANG DIPILIH.
 HYDRO CARBON BASED. JUMLAH HYDROGEN VARIATIF TERGANTUNG
DIMANA DI TAMBANG. UMUMNYA ELEMEN HYDROGEN [ 15 - 18 ] % BERAT.
 ELEMEN LAIN PARAFIN,
 UNTUK Bh. BAKAR BOILER VARIATIF GOLONGANNYA : RESIDU ( MFO ) Mi.
DIESEL BERAT ( MDF )
 UNTUK EFISIENSI, Bh. BAKAR CAIR BERAT MEMERLUKAN PREHEATING
PROSES.
 KANDUNGAN KARBON RELATIF TINGGI. BERAKIBAT ABRASI CUKUP TINGGI
dan PEMBENTUKAN SOOT TINGGI.
 YANG PERLU DIWASPADAI ADALAH KANDUNGAN SULFUR HARUS SERENDAH
MUNGKIN MAX [ 0.5 – 2.0 ] %  UNTUK MENGHIDARKAN TIMBULNYA SOX
PADA EMISI GAS BUANG. . Dst..
NILAI KALORI
MAKIN BESAR- SIFAT-2 FOSSIL ( COAL FUEL )
MAKIN ENCER
DIBAHAS KHUSUS 51
BOILER BASICS INDUSTRIAL BOILER

FUEL FIRING SYSTEMS


ALTERNATIVE PENGGUNAAN BH. BAKAR dan SISTEMNYA
 PADA UMUMNYA MENGGUNAKAN COAL dan / atau REFUSED PRODUCT A.L. :
BAGGASE, BIOMASS, REFUSED DERIVED FUEL( RDF ), MUNICIPAL SOLID WASTE ( MSW ),
COAL -SPREADER STOKER DAN COAL PULVERIZED ( PC ) DENGAN PERTIMBANGAN EKONOMI :
FUEL PRICE, FUEL PROCESS COST ( SHIPMENT, PROCESSING COST, HANDLINGS ETC)

PILIHAN CP FIRED Vs STOKER - FIRED BOILER

CP - FIRED ; CP - FIRED
• CARBON TIDAK TERBAKAR 0.4% • KARBON TIDAK TERBAKAR 4 - 8 %
• EFFISIENSI PEMBAKARAN LEBIH TINGGI • EFISIENSI PEMBAKARAN RENDAH KARENA COAL LE
KARENA KELEMBUTAN COAL MENCAPAI 200 -BIH KASAR 20 MESH SCREEN ( 20 mm )
MESH SCREEN ( 70 - 80 ) % PC
• CENDERUNG MEMBENTUK CLINKER ( GUMPALAN
• SLAGGING DAN / ATAU FOULING TERJADI KERAK )
DIDAERAH “ KANTUNG “

• MENENTUKAN TINGGI STACK BERKAITAN DENGAN EMISI.


• MENENTUKAN VOLUME FURNACE BERKAITAN DENGAN “ TIME “ DALAM
PROSES PEMBAKARAN.

52
BOILER BASICS FUEL FIRING SYSTEMS
STOKER FIRING SYSTEM
TANGENTIAL
OFA ( 5 - 20 % )
ACTIVE
COKING COMBUSTION
ZONE ZONE

DISTRIBUTOR CARBON -
RECOVERY
NOZZLE
AUX. AUX.
AIR AIR

ASH ASH
GRATES
PRIMARY
AIR RETURN RAILS

UNDERFEED STOKER
OVERFEED STOKER
• COCOK UNTUK CONSTANT LOAD
TRAVELLING - GRATE STOKER
• CENDEREUNG MEMBENTUK CLINKER
• RESPONSIVE THD. PEROBAHAN
LOAD

OFA = OVER FIRE AIR • PENGERINGAN SEMENTARA FUEL


“ MELAYANG “. TERBAKAR SEBELUM
• BERFUNGSI UNTUK MENCEGAH TEMPERATURE JATUH KE TRAVELLING GRATE.
GAS PEMBAKARAN MENCAPAI MAX. DAN
MENGONTROL TEMP. SUPERHEATERS. • KLINKER MINIMAL

• TEMP. UDARA MAX. BERAKIBAT MERUSAK • CELLULOSE FUELS ( WOOD,


53
BAGGASE, RESIDUE SLUDGE, RICE
LINGKUNGAN MEMBENTUK NOX DAN SOX.
HULLS, COFFE GROUNDS, DLL )
BOILER BASICS
STEAM GENERATOR
SUPERHEATER
• PIPA - PIPA PENGERING UAP SATURATED MENJADI
KERING ( SUPERHEATED STEAM )
• BERLAKU HUKUM GAS SEMPURNA
• KHUSUS UNTUK MENGGERAKKAN TURBIN UAP
• MAKIN TINGGI TEKANAN DAN TEMP. UAP SPHT. MAKIN
TINGGI MENYIMPAN KALORI / ENERGY PANAS
• PENEMPATAN DIDALAM BOILER :
 LANGSUNG DIDAERAH RADIASI PEMBAKARAN
 ATAU DIBELAKANG PIPA - PIPA AIR YANG BERFUNGSI
SEBAGAI SCREEN / BAFFLE SESUAI TEMP. UAP
YANG DIBUTUHKAN

EKONOMIZER
FUNGSI :
* MENAIKKAN TEMP. FEEDWATER SEBELUM MASUK
KEDALAM STEAM DRUM
* MENURUNKAN TEMP. GAS BUANG
* MENGHEMAT BAHAN BAKAR / MENAIKKAN EFISIENSI
BOILER
* MENGATUR DEW POINT PADA STACK/ AGAR TIDAK
MERUSAK LINGKUNGAN

CARA :
• TERPASANG PADA SALURAN BUANG GAS SEBELUM
MASUK KE STACK / CEROBONG
• LUAS BIDANG PERTUKARAN PANAS DIBESARKAN54
DENGAN MEMASANG CINCIN / FIN
BOILER BASICS

PEMANAS UDARA (AIR PREHEATER)


 UDARA SEBELUM MASUK KEDALAM BOILER
DIPANASKAN TERLEBIH DAHULU UNTUK
MENINGKATKAN TEMP. SEKALIGUS UNTUK
MENINGKATKAN EFISIENSI
 MENURUNKAN KERUGIAN PANAS AKIBAT
RADIASI DARI BADAN BOILER

CARA :
 PADA BOILER BESAR (UTILITY DAN
INDUSTRIAL) DILENGKAPI DENGAN ALAT
KHUSUS UNTUK MENANGKAP PANAS DARI
GAS BUANG ( ROTARY TYPE)
 PADA TYPLE BOILER KECIL (PACKAGE TYPE),
PANAS DIAMBIL DARI SALURAN UDARA /
RUANG DIANTARA DINDING LUAR - DALAM
 TUBULAR AIR HEATER ( UDARA YANG
DIPANASKAN MENGALIR DIDALAM PIPA-2
YANG TERPASANG HORIZONTAL DIDALAM
SALURAN GAS BUANG. BENTUK PIPA MIRIP
PIPA-2 EKONOMIZER
 HEAT-PIPE AIR HEATERS (Q-PIPE). TYPE INI
TIDAK ADA BAGIAN YANG BERGERAK

55
Q - PIPE HEATER
BOILER BASICS BEBERAPA TYPE ALAT PEMANAS UDARA PEMBAKARAN ( AIR HEATER )
GAS PANAS DAMPER
GAS DINGIN

UDARA
DINGIN

56
BOILER BASICS
AIR PREHEATERS

2 TYPE :
1. BI - SECTOR ( UDARA ATMOSFER PLUS HOT FLUE
GAS SECTION )
2. TRI - SECTOR ( UDARA ATMOSFER PLUS
PRIMARY AIR SECTION UNTUK MILL PLUS
SECONDARY AIR SECTION UNTUK PEMBAKARAN

AIR LEAKAGE DARI AIR STREAM KE GAS STREAM :


1. RADIAL LEAKAGE, DIATASI DENGAN RADIAL
SEALING UPPER & LOWER
2. AXIAL LEAKAGE, DIATASI DENGAN AXIAL
SEALING

AIR HEATER
TERPASANG DI UNIT UNTUK PERTIMBANGAN EKONOMIS, AH.
PLTU PAITON ELEMEM DIBUAT DALAM 3 SECTION
ELEMENT : HOT END, INTERMEDIATE DAN
COLD END ELEMENT
HOT END ELEMENT ( MILD STEEL )

INTERMEDIATE ELEMENT RPM = 1

COLD END ELEMENT.


TEMP MAX. 74 0C DENGAN PULVERIZED 57
COAL atau 66 0C (OIL / NATURAL GAS).
MAT’L : STAINLESS STEEL
BOILER BASICS AIR PREHEATERS

PERLENGKAPAN AIR PRREHEATERS :


1. SOOT BLOWER PADA COLD & HOT END ELEMEMT.
BEKERJA TIAP 8 JAM ( NORMAL SETTING) ATAU SESUAI PRESSURE DROP ( GASIN ) DAN
( GAS OUT ) ATAU BILA ADA SIGNAL DARI FLAME SCANNER.
A. PADA COLD END DENGAN SATURATED STEAM TEMP. 332 0C ATAU SUPERHEATED
STEAM TEMP. 142 0 C. TEKANAN ( 12 - 14 ) kg/ Cm2 )
B. PADA HOT END DENGAN SAT. STEAM ( TEMP. 301 0C ATAU SUPERHEATED 152 0C )
TEKANAN 9 kg / Cm2 .

2. OFF-LINE WATER WASHING :


DILAKSANAN PQADA SAAT SHUT-DOWN DENGAN MEDIUM AIR BERSIH.
PERTIMBANGAN WASHING :
- FUEL QUALITY - OPERATING CONDITIONS
- DRYNESS OF SHOOTBLOWING MEDIUM - NATURE OF DEPOSIT

3. SENSOR
- FLAME SCANNER ( MEMONITOR SPARKS atau HOT SPOT ),
- LOW TEMP. SENSOR ( KEMUNGKINAN ELEMEN KOTOR ,
- LOW COOLING WATER FLOW,
- INFRA RED SENSOR HOT ( BEKERJA BILA TERDAPAT HOT SPOT DENGAN TEMP
. 142 0F ( 61 0C )
- PRESSURE PROBE DI HOT GAS INTAKE DAN DI COLD GAS OUTLET SIDE.

4. MOTOR DRIVE DENGAN RPM SESUAI TYPE SPECIFIC ( 1 - 2 ) RPM

58
BOILER BASICS Air Heater L’JUNGSTRUM

PLAT ELEMEN
PENYIMPAN
PANAS.

GAS SIDE EFFICIENCY :


BASKET ELEMENT
• BILA SHUTDOWN DALAM JANGKA LAMA, GAS DROP TEMP
DISARANKAN AH. ELEMEN DILAPISI DENGAN ANTI  EFISIENSI A.H =---------------------------------
RUST : TEMPERATURE HEAD
- KENDALL
- KENCOAT 60  T DROP =
- TEXACO NO. 1052
- METAL PROTECTIVE OIL
TEMP. GAS INLET - TEMP. GAS OUTLET
- MOBIL - MOBILARAMA 245  T HEAD = 59
- LOW FLASH POINT
TEMP. GAS INLET - TEMP. UDARA KELUAR
BOILER BASICS
EFISIENSI BOILER

EFISIENSI = RENDEMEN = DAYA GUNA


 EFISIENSI ADALAH PERBANDINGAN NILAI KEUNTUNGAN YANG BISA DIPEROLEH ( Rp DI
JUAL ) DENGAN DAYA YANG TERSEDIA ( Rp YANG DIBELI )
 MAKIN TINGGI NILAI EFISIENSI, BOILER AKAN MAKIN HEMAT BAHAN BAKAR
 EFISIENSI DINILAI TIDAK HANYA DARI SEGI PERHITUNGAN TEKNIS SAJA, TETAPI
JUGA DARI PERHITUNGAN EKONOMINYA

INPUT - OUTPUT H1 - h2 t1 - t2
 = EFFISIENSI = = =
INPUT INPUT t1

 INPUT = TOTAL ENERGY YANG DIBERIKAN KEPADA SYSTEM.


 OUTPUT = INPUT -- SEMUA KERUGIAN.
BESARNYA KERUGIAN TERGANTUNG PADA KONDISI TEKNIS UNIT, PADA POLA
PENGOPERASIAN, PADA USIA UNIT DAN KOMPONENNYA.
 KERUGIAN DALAM BOILER a.l PANAS HILANG, PEMBAKARAN TIDAK
SEMPURNA, KEBOCORAN GAS / UAP / AIR, PIPA BOILER YANG KOTOR PADA
SISI GAS DAN / ATAU SISI AIR, DLL

60
BOILER BASICS
STEAM GENERATOR ENERGY FLOIW
Air from ID Fan

Heated Air to Furnace

Furnace
Wall (50%) &
SH (35-45%) Air Heater
RH Economizer

Energy Loss to Stack


(1 - 1,5 % )

5 - 15 %
BOILER

Steam ke • KALOR HILANG / RADIASI


HP Turbine Steam ke TGT.KAPASITAS, USIA DAN DESIGN
LP Turbine BOILER ( 1.5 - 2.5 % ).
• CREDIT HEAT = ENERGY YANG
DISUPPLY DARI LUAR SYSTEM BOILER
( LISTRIK PLN DLL )

SCAN DSS TRNG HAL 21 61


BOILER BASICS

BAHAN BAKAR GAS ( LNG / LPG )


 TIDAK MEMERLUKAN POMPA DAN PERSIAPAN UNTUK LIGHT OFF
 MEMERLUKAN PENGAWASAN YANG KETAT TERHADAP BAHAYA KEBOCORAN
 SUPPLY UDARA HARUS TEPAT JUMLAHNYA UNTUK MENGHINDARI EXPLOSI
 KANDUNGAN KARBON SANGAT RENDAH
 DIUKUR DENGAN FLOWMETER
 ANGKA NOX SANGAT RENDAH

UDARA PEMBAKARAN
• STOICHIOMETRIC = JUMLAH UDARA / OXYGEN YANG DIBUTUHKAN UNTUK TEPAT
MEMBAKAR SEJUMLAH TERTENTU BH. BAKAR. TIDAK ADA SISA BH. BAKAR YANG
TIDAK TERBAKAR. TETAPI TIDAK ADA DISTRIBUSI PANAS KE SEKITARNYA. ( G1)
• UDARA / OXYGEN TEORITIS = JUMLAH UDARA YANG DIPERLUKAN UNTUK
MEMBAKAR SEJUMLAH TERTENTU BH. BAKAR DAN MEMIMDAHKAN / MENGALIRKAN
PADA RUANG YANG MEMBATASI PROSES PEMBAKARAN . ( G2 )
• EXCESS AIR = JUMLAH UDARA / OXYGEN YANG DIPERLUKAN UNTUK MEMBAKAR
SEJUMLAH BH. BAKAR SEKALIGUS MEMINDAHKAN / MENGALIRKAN PANAS YANG
DIHASILKANNYA KE TEMPAT LAIN. TERJADI DISTRIBUSI PANAS G3 = G1+ G2 + G ex )
• OVER FIRE AIR ( OFA ) = UDARA YANG DISUPPLY KEPROSES PEMBAKARAN,
MEMAYUNGI GAS PEMBAKARAN BERFUNGSI UNTUK :
1 MENCEGAH TEMPERATURE SUPERHEATED STEAM MENCAPAI MAXIMUM,
2. MENGENDALIKAN EMISI GAS BUANG KE ATMOSFER TIDAK MERUSAK
LINGKUNGAN ( NOX & SOX )
62
BOILER BASICS
KONSTRUKSI
BUCKSTAY
 BUCKSTAY ADALAH KERANGKA YANG MEMPERKUAT BANGUNAN BOILER
KEARAH VERTIKAL - HORIZONTAL SEKALIGUS SEBAGAI PELINDUNG TERHADAP
IMPACT DARI LUAR
 HARUS MAMPU MENGANTISIPASI EXPANSI KESEMUA ARAH
 MAMPU MENGANTISIPASI KEMUNGKINAN EXPLOSI, IMPLOSI DAN GEO SEISMIC

63
BOILER BASICS
STEEL STRUCTURE
SEBAGAI TOP STEEL STRUCTURE
SUPPORT ( KERANGKA PENGUAT)
• TERGANTUNG DESIGN BOILER
• BOTTOM SUPPORT
PRESSURE PARTS  BOILER DI BERDIRI PADA FONDASI
TERPASANG DIATAS TANAH
MENGGANTUNG  PACKAGE BOILER KECIL S / D BESAR

• TOP SUPPORT
 BOILER DI BERDIRI DENGAN
MENGGANTUNG PADA PILAR-PILAR
BAJA YANG SANGAT KUAT
 MENGHEMAT AREAL TANAH
 ANTI GEMPA dan FLEXIBLE TERHADAP
PEROBAHAN EXPANSI PADA
 FLEXIBLE TERHADAP PEROBAHAN /
PERGESERAN RELATIF ANTARA PIPA-2
BOILER DENGAN TOP SUPPORT DENGAN KONSTRUKSI BOILER
 UNTUK BOILER BESAR / RAKSASA

64
BOILER BASICS

CONTRACT DATA SHEET


 DATA YANG MENYEBUTKAN KEMAMPUAN, SPESIFIKASI TEKNIS DAN DATA
 SESUAI PERHITUNGAN DESIGN. CDS DITERBITKAN OLEH PABRIK PEMBUAT
BOILER
 SANGAT BERGUNA PADA SAAT PERFORMANCE TEST, SEBAGAI PEDOMAN
DALAM PELAKSANAAN “ KALIBRASI UNIT BOILER “ SETELAH SELESAI
PELAKSANAAN PEMELIHARAAN SEBAGAI DATA PEMBANDING,
PEMELIHARAAN DAN PENGUKURAN DAYA / EFISIENSI SECARA BERKALA
 CONTRACT DATA SHEET HARUS DIKETAHUI PARA OPERATOR UNTUK
MENGETAHUI APAKAH UNIT BOILER YANG DIOPERASIKAN SESUAI DENGAN
KAPASITAS DESIGN. MANUFACTURER HARUS MENJAMIN KEBENARAN
PRODUKNYA.
 MELIPUTI DATA KEMAMPUAN PER KOMPONEN, SUB KOMPONEN DAN
SECARA KESELURUHAN KEMAMPUAN UNIT
 SETIAP KALI UNIT BOILER MENJALANI MAJOR OVERHAUL HARUS DISERTAI
COMMISSIONING DAN HASIL PERFORMANCE TEST HARUS SI COCOKKAN
DENGAN PERFORMANCE DALAM CONTRACT DATA SHEET..

65