Anda di halaman 1dari 94

Buku Pedoman Pengawasan dan

Asesmen

SALURAN UDARA TEGANGAN TINGGI


DAN EKSTRA TINGGI (SUTT/SUTET)
Dokumen nomor : PDM/STT/23:2014

PT PLN (PERSERO)
Jl Trunojoyo Blok M I/135
JAKARTA
NOMOR : PDM/STT/23:2014
DOKUMEN Lampiran Surat Keputusan Direksi

PT PLN (PERSERO) PT PLN (Persero) No. 0520-1.K/DIR/2014

BUKU PEDOMAN PENGAWASAN


DAN ASESMEN SALURAN UDARA
TEGANGAN TINGGI DAN EKSTRA
TINGGI (SUTT/SUTET)

PT PLN (PERSERO)

JALAN TRUNOJOYO BLOK M-I/135 KEBAYORAN BARU

JAKARTA SELATAN 12160


PENGAWASAN DAN ASESMEN SUTT/SUTET

Susunan Tim Review KEPDIR 113 & 114 Tahun 2010


Surat Keputusan Direksi PT PLN (Persero) No.0309.K/DIR/2013

Pengarah : 1. Kepala Divisi Transmisi Jawa Bali


2. Kepala Divisi Transmisi Sumatera
3. Kepala Divisi Transmisi Indonesia Timur
4. Yulian Tamsir
Ketua : Tatang Rusdjaja
Sekretaris : Christi Yani
Anggota : Indra Tjahja
Delyuzar
Hesti Hartanti
Sumaryadi
James Munthe
Jhon H Tonapa
Kelompok Kerja Manajemen ROW SUTT/SUTET
1. Arief Ibrahim Wuller (PLN P3BJB) : Koordinator merangkap anggota

2. Dedi Supriadi (PLN P3BJB) : Anggota

3. Chandra Solinar (PLN P3BS) : Anggota

4. Wahyu Sudrajat (PLN P3BS) : Anggota

5. Victor Hadjon (PLN Sulselrabar) : Anggota

6. Suwarso (PLN Kalselteng) : Anggota

7. Richard Rosanov L / Rufinus (PLN Kaltim) : Anggota

8. M Sabli (PLN Kalbar) : Anggota

Koordinator Verifikasi dan Finalisasi Review KEPDIR 113 & 114 Tahun
2010 (Nota Dinas KDIVTRS JBS Nomor 0018/432/KDIVTRS JBS/2014)
Tanggal 27 Mei 2014
1. Jemjem Kurnaen
2. Sugiartho
3. Yulian Tamsir
4. Eko Yudo Pramono
PENGAWASAN DAN ASESMEN SUTT/SUTET

DAFTAR ISI

DAFTAR ISI .......................................................................................................................I


DAFTAR GAMBAR ..........................................................................................................III
DAFTAR TABEL ............................................................................................................. IV
DAFTAR LAMPIRAN ...................................................................................................... VI
PRAKATA ...................................................................................................................... VII
BUKU PEDOMAN PENGAWASAN DAN ASESMEN SALURAN UDARA TEGANGAN
TINGGI DAN EKSTRA TINGGI.........................................................................................1
1 PENDAHULUAN .............................................................................................1
1.1 Latar Belakang.................................................................................................1
1.2 Ruang Lingkup.................................................................................................1
2 METODE PENGAWASAN SUTT/SUTET ........................................................1
2.1 Ground Patrol...................................................................................................2
2.1.1 Sistem Pelaksanaan Ground Patrol..................................................................3
2.1.2 Tugas dan Tanggung Jawab ............................................................................6
2.2 Climb Up Inspection .........................................................................................8
2.2.1 Sistem Pelaksanaan Climb Up Inspection ........................................................8
2.2.2 Tugas dan Tanggung Jawab ..........................................................................11
3 ASESMEN ANCAMAN PADA SUTT/SUTET ................................................12
3.1 Asesmen Ancaman Kondisi Lingkungan ........................................................12
3.2 Asesmen Ancaman Kondisi Pondasi.............................................................. 18
3.2.1 Asesmen Ancaman Kondisi Pondasi Tower Lattice........................................18
3.2.2 Asesmen Ancaman Kondisi Pondasi Tower Steel Pole ..................................20
4 ASESMEN KONDISI KOMPONEN SUTT/SUTET .........................................21
4.1 Sub Sistem Current Carrying..........................................................................22
4.1.1 Konduktor.......................................................................................................22
4.1.2 Jumper Konduktor..........................................................................................23
4.1.3 Jumper Joint ..................................................................................................24
4.1.4 Midspan Compression Joint ...........................................................................24
4.2 Sub Sistem Insulation.....................................................................................24
4.2.1 Insulator .........................................................................................................25
4.2.1.1 Ceramic Insulator ........................................................................................... 25
4.2.1.2 Non-Ceramic Insulator ...................................................................................25
4.2.2 ROW (Right Of Way) atau Ruang Bebas........................................................26
4.3 Structure ........................................................................................................33
4.3.1 Member/ Besi Siku/ Bracing ...........................................................................33
4.3.2 Cat/ Galvanis Tiang........................................................................................34
4.3.3 Chimney/ Kepala Pondasi ..............................................................................34
4.3.4 Halaman Tower.............................................................................................. 35
4.3.5 Mur dan Baut Tower.......................................................................................35
4.3.6 Plat Sambungan Rangka ...............................................................................36
4.3.7 Stub ...............................................................................................................36
4.4 Sub Sistem Junction ......................................................................................37
4.4.1 Box Joint OPGW ............................................................................................ 37
4.4.2 Fitting Insulator............................................................................................... 37
4.4.2.1 Suspension/ Tension Clamp...........................................................................37
4.4.2.2 Clevis, Plate, Link, Shackle, Turn Buckle, Socket...........................................38
4.4.3 Ikatan Insulator............................................................................................... 38
4.4.4 Sealing End Kabel (Tower Transisi SUTT - SKTT).........................................39

i
PENGAWASAN DAN ASESMEN SUTT/SUTET

4.5 Sub Sistem Protection ................................................................................... 39


4.5.1 Kawat Tanah/ GSW/ OPGW .......................................................................... 40
4.5.2 Arching Horn.................................................................................................. 40
4.5.3 Jumper GSW ................................................................................................. 41
4.5.4 Konduktor Penghubung Kawat Tanah ........................................................... 41
4.5.5 Kawat Grounding ........................................................................................... 42
4.5.6 Spacer ........................................................................................................... 43
4.5.7 Armour Rod ................................................................................................... 43
4.5.8 Vibration Damper, Counter Weight ................................................................ 44
4.5.9 Anti Climbing Device...................................................................................... 44
4.5.10 Plat Rambu Bahaya....................................................................................... 45
4.5.11 Bola Rambu................................................................................................... 45
4.5.12 Aviation Lamp/ Lampu Aviasi......................................................................... 46
4.5.13 Lampu Indikator Tower .................................................................................. 47
4.5.14 Repair Sleeve ................................................................................................ 47
4.5.15 Armour Rod Span .......................................................................................... 47
4.5.16 TLA (Transmission Line Arrester) .................................................................. 48
4.5.17 Jejaring Pengaman (Vangnet) ....................................................................... 49
4.6 Sub Sistem Monitoring................................................................................... 49
4.6.1 Plat Informasi Tower...................................................................................... 49
4.6.2 Baut Panjat .................................................................................................... 50
4.6.3 Patok Batas ................................................................................................... 50
DAFTAR ISTILAH........................................................................................................... 76
DAFTAR PUSTAKA ....................................................................................................... 80

ii
PENGAWASAN DAN ASESMEN SUTT/SUTET

DAFTAR GAMBAR

Gambar 2-1 Sistem Pelaksanaan Ground Patrol dan pembagian tugasnya.......................4


Gambar 2-2 Contoh tampilan Srintami Mobile di Smart Phone berbasis Android...............5
Gambar 2-3 Contoh tampilan Srintami Client di PC Gardu Induk/ Tragi .............................6
Gambar 2-4 Contoh tampilan Srintami Server....................................................................6
Gambar 2-5 Sistem Pelaksanaan Climb Up Inspection (CUI) dengan climber dari pihak
luar ....................................................................................................................................9
Gambar 2-6 Sistem Pelaksanaan Climb Up Inspection (CUI) dengan climber dari PLN...10
Gambar 3-1 Contoh kondisi dan ukuran lereng dan tebing ..............................................16
Gambar 3-2 Contoh kondisi posisi sungai dalam (kiri) dan kondisi posisi sungai luar
(kanan) ............................................................................................................................16
Gambar 3-3 Checklist Asesmen Ancaman Kondisi Lingkungan.......................................17
Gambar 3-4 Checklist asesmen ancaman kondisi pondasi tower Lattice .........................19
Gambar 3-5 Checklist asesmen ancaman kondisi pondasi tower steel pole ....................21
Gambar 4-1 Dasar justifikasi dan asesmen kondisi komponen SUTT/SUTET..................22
Gambar 4-2 Perhitungan Jarak ROW Konduktor SUTT/SUTET dengan pohon dibawah
jalur (C)............................................................................................................................29
Gambar 4-3 Perhitungan Jarak ROW Konduktor SUTT/SUTET dengan pohon disamping
jalur (C’) ...........................................................................................................................30
Gambar 4-4 Perhitungan Jarak ROW Konduktor SUTT/SUTET dengan bangunan
dibawah jalur (C)..............................................................................................................31
Gambar 4-5 Perhitungan Jarak ROW Konduktor SUTT/SUTET dengan antena di luar
jalur, antena lebih tinggi dari konduktor SUTT/SUTET (C’) ..............................................32
Gambar 4-6 Tampilan login aplikasi CBM ........................................................................51
Gambar 4-7 Tampilan database di aplikasi CBM .............................................................51
Gambar 4-8 Contoh tampilan checklist dalam aplikasi CBM ............................................52

iii
PENGAWASAN DAN ASESMEN SUTT/SUTET

DAFTAR TABEL

Tabel 2-1 Standar kriteria geografis tower ......................................................................... 2


Tabel 2-2 Standar kriteria kerawanan jalur SUTT/SUTET ................................................. 2
Tabel 3-1 Standar asesmen ancaman kondisi lingkungan............................................... 12
Tabel 3-2 Standar asesmen ancaman kondisi pondasi tower Lattice............................... 18
Tabel 3-3 Standar asesmen ancaman kondisi pondasi tower steel pole.......................... 20
Tabel 4-1 Standar justifikasi kondisi komponen SUTT/SUTET dan rekomendasi tindak
lanjutnya.......................................................................................................................... 22
Tabel 4-2 Asesmen kondisi konduktor melalui inspeksi GP mingguan ............................ 22
Tabel 4-3 Asesmen kondisi konduktor melalui inspeksi Climb Up ................................... 23
Tabel 4-4 Asesmen kondisi jumper konduktor melalui inspeksi Climb Up........................ 23
Tabel 4-5 Asesmen kondisi jumper konduktor melalui inspeksi GP mingguan................. 23
Tabel 4-6 Asesmen kondisi jumper joint melalui inspeksi Climb Up................................. 24
Tabel 4-7 Asesmen kondisi midspan compression joint melalui inspeksi Climb Up ......... 24
Tabel 4-8 Asesmen kondisi Insulator (ceramic dan non-ceramic) melalui inspeksi Climb
Up ................................................................................................................................... 25
Tabel 4-9 Asesmen kondisi non ceramic insulator melalui inspeksi GP mingguan .......... 25
Tabel 4-10 Asesmen kondisi ceramic insulator melalui inspeksi GP mingguan ............... 25
Tabel 4-11 Standar jarak bebas minimum ROW/ jarak aman (Peraturan Menteri
Pertambangan dan Energi No.01.P/47/MPE/1992 tanggal 7 Februari 1992 dan SNI 04-
6918-2002)...................................................................................................................... 26
Tabel 4-12 Asesmen kondisi ROW melalui inspeksi GP mingguan ................................. 27
Tabel 4-13 Asesmen kondisi ROW melalui inspeksi Climb Up ........................................ 28
Tabel 4-14 Asesmen kondisi member/ besi siku/ bracing melalui inspeksi Climb Up....... 33
Tabel 4-15 Asesmen kondisi member/ besi siku/ bracing melalui inspeksi GP mingguan 33
Tabel 4-16 Asesmen kondisi member/ besi siku/ bracing melalui inspeksi GP triwulanan33
Tabel 4-17 Asesmen kondisi cat/ galvanis tiang melalui inspeksi Climb Up..................... 34
Tabel 4-18 Asesmen kondisi cat/ galvanis tiang melalui inspeksi GP triwulanan ............. 34
Tabel 4-19 Asesmen kondisi chimney/ kepala pondasi melalui inspeksi GP mingguan ... 34
Tabel 4-20 Asesmen kondisi halaman tower melalui inspeksi GP minguan..................... 35
Tabel 4-21 Asesmen kondisi mur dan baut tower melalui inspeksi Climb Up................... 35
Tabel 4-22 Asesmen kondisi mur dan baut tower melalui inspeksi GP triwulanan ........... 35
Tabel 4-23 Asesmen plat sambungan rangka melalui inspeksi Climb Up ........................ 36
Tabel 4-24 Asesmen plat sambungan rangka melalui inspeksi GP mingguan ................. 36
Tabel 4-25 Asesmen kondisi stub melalui inspeksi GP mingguan ................................... 36
Tabel 4-26 Asesmen kondisi box joint OPGW melalui inspeksi Climb Up........................ 37
Tabel 4-27 Asesmen kondisi suspension/ tension clamp melalui inspeksi Climb Up ....... 37
Tabel 4-28 Asesmen kondisi Clevis, Plate, Link, Shackle, Turn Buckle, Socket melalui
inspeksi Climb Up............................................................................................................ 38
Tabel 4-29 Asesmen kondisi ikatan insulator melalui inspeksi Climb Up ......................... 38
Tabel 4-30 Asesmen kondisi Sealing End Kabel (Tower Transisi SUTT-SKTT) melalui
inspeksi GP mingguan..................................................................................................... 39
Tabel 4-31 Asesmen kondisi kawat tanah/ GSW/ OPGW melalui inspeksi Climb Up ...... 40
Tabel 4-32 Asesmen kondisi kawat tanah/ GSW/ OPGW melalui inspeksi GP mingguan 40
Tabel 4-33 Asesmen kondisi arcing horn melalui inspeksi GP triwulanan........................ 40
Tabel 4-34 Asesmen kondisi arcing horn melalui inspeksi Climb Up ............................... 41
Tabel 4-35 Asesmen kondisi jumper GSW melalui inspeksi GP mingguan...................... 41
Tabel 4-36 Asesmen kondisi konduktor penghubung kawat tanah melalui inspeksi Climb
Up ................................................................................................................................... 41
Tabel 4-37 Asesmen kondisi kawat grounding melalui inspeksi Climb Up ....................... 42
Tabel 4-38 Asesmen kondisi kawat grounding melalui inspeksi GP mingguan ................ 42

iv
PENGAWASAN DAN ASESMEN SUTT/SUTET

Tabel 4-39 Asesmen kondisi spacer melalui inspeksi Climb Up.......................................43


Tabel 4-40 Asesmen kondisi spacer melalui inspeksi GP mingguan................................43
Tabel 4-41 Asesmen kondisi armour rod melalui inspeksi Climb Up ................................43
Tabel 4-42 Asesmen kondisi vibration damper melalui inspeksi GP triwulanan................44
Tabel 4-43 Asesmen kondisi vibration damper dan counter weight melalui inspeksi Climb
Up....................................................................................................................................44
Tabel 4-44 Asesmen kondisi Anti Climbing Device melalui inspeksi GP mingguan..........44
Tabel 4-45 Asesmen kondisi plat rambu bahaya melalui inspeksi GP mingguan .............45
Tabel 4-46 Asesmen kondisi bola rambu melalui inspeksi GP triwulanan ........................45
Tabel 4-47 Asesmen kondisi bola rambu melalui inspeksi Climb Up................................46
Tabel 4-48 Asesmen kondisi aviation lamp melalui inspeksi GP triwulanan .....................46
Tabel 4-49 Asesmen kondisi aviation lamp melalui inspeksi Climb Up.............................46
Tabel 4-50 Asesmen kondisi lampu indikator tower melalui inspeksi Ground Patrol
Triwulan ...........................................................................................................................47
Tabel 4-51 Asesmen kondisi repair sleeve melalui inspeksi Climb Up .............................47
Tabel 4-52 Asesmen kondisi armour rod span melalui inspeksi Climb Up........................47
Tabel 4-53 Asesmen kondisi TLA melalui inspeksi Climb Up ...........................................48
Tabel 4-54 Asesmen kondisi TLA melalui inspeksi GP mingguan....................................48
Tabel 4-55 Asesmen kondisi jejaring pengaman (vangnet) melalui inspeksi GP mingguan
........................................................................................................................................49
Tabel 4-56 Asesmen kondisi plat informasi tower melalui inspeksi GP mingguan............49
Tabel 4-57 Asesmen kondisi baut panjat melalui inspeksi Climb Up ................................50
Tabel 4-58 Asesmen kondisi baut panjat melalui inspeksi GP mingguan .........................50
Tabel 4-59 Asesmen kondisi patok batas melalui inspeksi GP triwulanan........................50

v
PENGAWASAN DAN ASESMEN SUTT/SUTET

DAFTAR LAMPIRAN

Lampiran 1 TABEL PERIODE PENGAWASAN DAN ASESMEN SUTT/SUTET.............. 53


Lampiran 2 Gambar Contoh Tower Transmisi ................................................................. 56
Lampiran 3 Foto Komponen SUTT/SUTET ..................................................................... 60
Lampiran 4 FOTO CONTOH LINGKUNGAN TOWER..................................................... 74

vi
PENGAWASAN DAN ASESMEN SUTT/SUTET

PRAKATA

PLN sebagai perusahaan yang asset sensitive, dimana pengelolaan aset memberi
kontribusi yang besar dalam keberhasilan usahanya, perlu melaksanakan pengelolaan
aset dengan baik dan sesuai dengan standar pengelolaan aset. Parameter Biaya, Unjuk
kerja, dan Risiko harus dikelola dengan proporsional sehingga aset bisa memberikan
manfaat yang maksimum selama masa manfaatnya.

PLN melaksanakan pengelolaan aset secara menyeluruh, mencakup keseluruhan fase


dalam daur hidup aset (asset life cycle) yang meliputi fase Perencanaan, Pembangunan,
Pengoperasian, Pemeliharaan, dan Peremajaan atau penghapusan. Keseluruhan fase
tersebut memerlukan pengelolaan yang baik karena semuanya berkontribusi pada
keberhasilan dalam pencapaian tujuan perusahaan.

Dalam pengelolaan aset diperlukan kebijakan, strategi, regulasi, pedoman, aturan, faktor
pendukung serta pelaksana yang kompeten dan berintegritas. PLN telah menetapkan
beberapa ketentuan terkait dengan pengelolaan aset yang salah satunya adalah buku
Pedoman pemeliharaan peralatan penyaluran tenaga listrik.

Pedoman pemeliharaan yang dimuat dalam buku ini merupakan bagian dari kumpulan
Pedoman pemeliharaan peralatan penyaluran yang secara keseluruhan terdiri atas 25
buku. Pedoman ini merupakan penyempurnaan dari pedoman terdahulu yang telah
ditetapkan dengan keputusan direksi nomor 113.K/DIR/2010 dan 114.K/DIR/2010.
Perubahan atau penyempurnaan pedoman senantiasa diperlukan mengingat perubahan
pengetahuan dan teknologi, perubahan lingkungan serta perubahan kebutuhan
perusahaan maupun stakeholder. Di masa yang akan datang, pedoman ini juga harus
disempurnakan kembali sesuai dengan tuntutan pada masanya.

Penerapan pedoman pemeliharaan ini merupakan hal yang wajib bagi seluruh pihak yang
terlibat dalam kegiatan pemeliharaan peralatan penyaluran di PLN, baik perencana,
pelaksana maupun evaluator. Pedoman pemeliharaan ini juga wajib dipatuhi oleh para
pihak diluar PLN yang bekerjasama dengan PLN untuk melaksanakan kegiatan
pemeliharaan di PLN.

Demikian, semoga kehadiran buku ini memberikan manfaat bagi perusahaan dan
stakeholder serta masyarakat Indonesia.

Jakarta, Oktober 2014

DIREKTUR UTAMA

NUR PAMUDJI

vii
PENGAWASAN DAN ASESMEN SUTT/SUTET

PENGAWASAN DAN ASESMEN SALURAN UDARA TEGANGAN TINGGI DAN


EKSTRA TINGGI

1 PENDAHULUAN

1.1 Latar Belakang

Instalasi tenaga listrik terdiri dari suatu sistem yang terintegrasi yang terdiri dari sistem
pembangkitan, sistem transmisi dan sistem distribusi. Sistem transmisi berfungsi untuk
menyalurkan daya listrik dari Sisi Pembangkit ke Gardu Induk Tegangan Tinggi / Ekstra
Tinggi dan dari GITET / GI / GIS ke GITET / GI / GIS lain melalui kawat telanjang dengan
aman dan dengan rugi daya yang kecil. Keandalan dari sistem tenaga listrik khususnya
sistem transmisi SUTT/SUTET akan sangat ditentukan oleh bagaimana sistem tersebut
dikelola, apalagi SUTT/SUTET melintasi daerah terbuka sehingga sangat rawan terhadap
gangguan baik gangguan berasal dari kondisi internal transmisi maupun yang berasal dari
gangguan eksternal seperti gangguan alam, gangguan binatang, tumbuh tumbuhan
maupun yang berasal dari aktifitas manusia.

Pedoman pengawasan dan asesmen SUTT/SUTET ditujukan agar SUTT/SUTET dapat


diawasi dengan metode yang tepat, dievaluasi kondisinya secara akurat dan selanjutnya
jika terdapat kondisi abnormal dapat dilaksanakan tindak lanjut dengan cepat dan tepat.
Dengan demikian diharapkan kondisi SUTT/SUTET akan selalu dalam kondisi yang andal
sehingga kelancaran penyaluran tenaga listrik ke konsumen dapat lebih terjamin.

1.2 Ruang Lingkup

Ruang lingkup pembahasan dalam buku pedoman pengawasan dan asesmen


SUTT/SUTET ini antara lain:

- Metode pengawasan SUTT/SUTET yang terdiri dari Ground Patrol dan


Climb Up Inspection.
- Konsep asesmen SUTT/ SUTET yang terbagi menjadi asesmen ancaman
dan asesmen kondisi komponen.
- Konsep asesmen ancaman pada SUTT/SUTET yang terdiri dari asesmen
ancaman kondisi lingkungan dan asesmen ancaman kondisi pondasi serta
rekomendasi hasil asesmennya.
- Konsep asesmen kondisi komponen SUTT/SUTET yang terdiri dari
komponen fungsi Current Carrying, Insulation, Structure, Junction, Protection
dan Monitoring beserta rekomendasi hasil asesmennya.

2 METODE PENGAWASAN SUTT/SUTET

Metode pengawasan SUTT/SUTET terdiri dari 2 jenis, yaitu Ground Patrol dan Climb Up
Inspection.

1
PENGAWASAN DAN ASESMEN SUTT/SUTET

2.1 Ground Patrol

Ground Patrol adalah pekerjaan pemantauan / pemeriksaan ruang bebas (ROW), kondisi
pondasi tower, kondisi lingkungan sekitar tower dan komponen instalasi SUTT/SUTET
lainnya serta pekerjaan pembersihan tapak tower dan ROW sesuai dengan tugas dan
tanggung jawabnya. Pekerjaan Ground Patrol dilaksanakan dengan menyusuri sepanjang
jalur SUTT/SUTET tanpa memanjat tower yang dilaksanakan secara terjadwal. Pelaksana
Ground Patrol yang dapat disebut Petugas Ground Patrol (PGP) ini berasal dari pihak luar
PLN (outsourcing) yang dikelola dengan sistem SLA (Service Leval Agreement) jasa
pemborongan pekerjaan pengawasan SUTT/SUTET (Ground Patrol).

Dalam menentukan jumlah dan harga jasa pemborongan pekerjaan pengawasan


SUTT/SUTET serta menentukan interval pengawasan Petugas Ground Patrol (PGP)
maka digunakan kriteria kondisi geografis tower dan kriteria kerawanan jalur
SUTT/SUTET yaitu sebagai berikut:

Tabel 2-1 Standar kriteria geografis tower

Faktor
Definisi
Geografis

Tower sulit dicapai dengan kriteria sebagai berikut:


1. Menggunakan alat transportasi khusus, seperti: perahu / sampan.
G1 2. Jalur melewati daerah pegunungan atau tebing curam, tidak dapat
diakses dengan kendaraan bermotor, memerlukan jalan kaki selama
lebih dari 2 jam.
3. Ancaman binatang buas.

G2 Selain kriteria G1

Tabel 2-2 Standar kriteria kerawanan jalur SUTT/SUTET

Faktor
Definisi
Kerawanan

1. Rawan pencurian komponen saluran transmisi. Pencurian terjadi 2 kali


R1 atau lebih dalam setahun pada jalur SUTT/SUTET yang sama.
2. Rawan kegiatan vandalisme / masalah sosial.

R2 Selain kriteria R1

Untuk menentukan pembobotan biaya digunakan rumus yaitu:

G1 = 1,5 G2

Sedangkan untuk standar Interval pengawasan jalur SUTT/SUTET berdasarkan faktor


kerawanan jalur SUTT/SUTET adalah sebagai berikut:

2
PENGAWASAN DAN ASESMEN SUTT/SUTET

R1 = jalur SUTT/SUTET diinspeksi kurang dari satu minggu sekali sesuai

keputusan manajer unit setempat.

R2 = jalur SUTT/SUTET diinspeksi setiap seminggu sekali

Jika dianggap perlu untuk mengoptimalkan pengawasan SUTT/SUTET metode Ground


Patrol di suatu unit, maka manajer unit dapat menentukan standar kriteria kerawanan dan
periode inspeksi tersendiri.

2.1.1 Sistem Pelaksanaan Ground Patrol

Poin - poin sistem pelaksanaan Ground Patrol yaitu sebagai berikut:

1. Setiap tiang/ tower dan span tower diperiksa secara periodik minimal 1x
seminggu atau disesuaikan dengan kondisi tingkat kerawanan dan atau
kondisi geografis setempat.

2. Peralatan kerja PGP dan standar kompetensi PGP harus memenuhi syarat
SLA (Service Level Agreement) sesuai yang diatur oleh PLN.

3. Kriteria penyedia jasa pemborongan pekerjaan pengawasan SUTT/SUTET


harus memenuhi syarat SLA (Service Level Agreement) sesuai yang diatur
oleh PLN.

4. Laporan Pelaksanaan Pekerjaan dan Sanksi kepada Pelaksana Jasa


Pemborongan sesuai dengan SLA (Service Level Agreement) yang diatur
oleh PLN.

5. Metode Ground Patrol dilaksanakan oleh 2 pihak yaitu pihak eksternal dan
pihak internal. Setiap pihak mempunyai beberapa level tingkatan dan
tugasnya masing-masing. Sistem pelaksanaan Ground Patrol dapat dilihat
pada tabel dibawah ini.

3
PENGAWASAN DAN ASESMEN SUTT/SUTET

Gambar 2-1 Sistem Pelaksanaan Ground Patrol dan pembagian tugasnya

Keterangan:

- Penanggung jawab setiap level disesuaikan dengan proses bisnis Ground


Patrol masing-masing unit wilayah PLN. Tiap-tiap unit wilayah PLN
menerjemahkan tugas dan tanggung jawab tersebut ke dalam struktur
organisasi di masing-masing unit.
- Pada pihak Eksternal (Luar PLN), posisi level 2 (Koordinator PGP) dapat
diisi oleh Koordinator PGP atau Supervisor PGP sesuai dengan proses
bisnis Ground Patrol masing-masing unit PLN.
- Pada pihak Internal (PLN), posisi level 1 (Pengawasan) atau dapat disebut
pengawas pekerjaan dapat diisi oleh Supv. JARGI, Supv. Har Tragi,
Koordinator GI atau Supv. Operasi sesuai dengan proses bisnis Ground
Patrol masing-masing unit PLN.
- Pada pihak Internal (PLN), posisi level 2 (Tindak Lanjut) dapat diisi oleh
Asman Pemeliharaan, Asman Penyaluran atau Manajer Tragi sesuai dengan
proses bisnis Ground Patrol masing-masing unit PLN.
- Pada pihak Internal (PLN), posisi level 3 (Evaluasi) dapat diisi oleh Asman
Renev atau Asman Enjiniring sesuai dengan proses bisnis Ground Patrol
masing-masing unit PLN.

4
PENGAWASAN DAN ASESMEN SUTT/SUTET

1. Metode Ground Patrol harus mempunyai sistem monitoring yang bertujuan untuk
mempermudah pengawasan kinerja Petugas Ground Patrol. Saat ini PLN
merekomendasikan sistem monitoring PGP dengan aplikasi Srintami (Sistem Rute
Inspeksi Transmisi) menggunakan Smart Phone berbasis Android dengan fitur GPS
dan Glonass. Aplikasi Srintami merupakan hasil inovasi PT PLN (Persero) P3B Jawa
Bali APP Surabaya dalam upaya peningkatan kualitas SLA (Service Level
Agreement) pengawasan SUTT/SUTET. Aplikasi Srintami dibentuk setelah evaluasi
dari sistem monitoring yang sudah ada seperti metode patuh waktu, gesek karbon,
rotasi gembok, barcode dan GPS dianggap belum optimal dalam memastikan PGP
benar-benar melaksanakan inspeksi ke lokasi towe/ span tower dengan periode yang
telah ditentukan dan belum dapat memastikan keakuratan hasil inspeksi yang sesuai
kondisi riil di lapangan. Aplikasi Srintami terdiri dari 3 komponen/ aplikasi yaitu:
Srintami Mobile, Srintami Client dan Srintami Server.

Proses bisnis atau cara kerja Aplikasi Srintami yaitu:

a. PGP melakukan inspeksi di tower menggunakan Smart Phone yang sudah


terinstall aplikasi Srintami Mobile dengan radius maksimal 50 meter dari tower.
Jika posisi PGP lebih dari 50 meter, maka aplikasi tidak dapat dibuka dan PGP
tidak dapat melaksanakan inspeksi. Sehingga PGP dituntut benar-benar
melaksanakan inspeksi di lokasi tower. Kemuadian jika terdapat kondisi
abnormal/ anomali maka hasil inspeksi anomali harus disertai foto dokumentasi
anomali tersebut, jika tidak disertai foto maka anomali tidak akan tercatat. Berikut
ini adalah contoh tampilan aplikasi Srintami Mobile.

Gambar 2-2 Contoh tampilan Srintami Mobile di Smart Phone berbasis Android

b. Setelah melaksanakan inspeksi, PGP atau Koordinator PGP membawa data


inspeksi ke Kantor GI / Tragi untuk upload data ke aplikasi srintami client di PC
(Personal Computer) Gardu Induk melalui koneksi USB.

5
PENGAWASAN DAN ASESMEN SUTT/SUTET

Gambar 2-3 Contoh tampilan Srintami Client di PC Gardu Induk/ Tragi

c. Setelah data inspeksi dan foto dokumentasi terkumpul di Srintami Client maka
data tersebut ditransfer ke Srintami Server dengan koneksi LAN (Local Area
Network). Output dari aplikasi Srintami yaitu: data rekap hasil inspeksi PGP dan
foto serta grafiknya, waktu dan frekuensi inspeksi PGP, durasi inspeksi dan
absensi PGP. Laporan tersebut dapat diakses melalui PC lain yang terhubung
via LAN ke server menggunakan browser.

Gambar 2-4 Contoh tampilan Srintami Server

2.1.2 Tugas dan Tanggung Jawab

Tugas dan tanggung jawab Petugas Ground Patrol yaitu sebagai berikut:

1. Melakukan pemeriksaan komponen-komponen SUTT/SUTET antara lain sebagai


berikut:

1) Stub 3) Halaman Tower

2) Chimney / Kepala pondasi 4) Member/ Besi Siku/ Bracing

6
PENGAWASAN DAN ASESMEN SUTT/SUTET

5) Plat sambungan rangka 18) Spacer pada penghantar *

6) Mur dan Baut Tower 19) Spacer pada jumper konduktor *

7) Cat / Galvanisasi 20) Aviation Lamp *

8) Pengelasan * 21) Bola Rambu *

9) Baut panjat 22) Lampu Indikator Tower *

10) Penghalang panjat (ACD / 23) Kawat tanah / GSW / OPGW


Anti Climbing Device)
24) Jumper GSW
11) Plat rambu bahaya
25) Vibration Damper
12) Plat informasi tower
26) Patok batas tanah tapak tower
13) Kawat Grounding *
27) ROW
14) Insulator
28) Jejaring pengaman / vangnet *
15) Arching Horn
29) TLA (Transmission Line Arrester)
16) Konduktor *

17) Jumper Konduktor 30) Sealing End Kabel (Tower


Transisi SUTT-SKTT) *

Keterangan: *) jika ada

1. Mengisi check list Ground Patrol yang terdiri dari checklist mingguan dan
checklist triwulan sesuai dengan kondisi SUTT/SUTET yang sebenarnya.
Checklist Ground Patrol mingguan dan triwulan dapat dilihat pada Buku
Pedoman Pemeliharaan Saluran Udara Tegangan Tinggi dan Ekstra Tinggi.

2. Melaporkan hasil inspeksi tower kepada Koordinator Petugas Ground Patrol 1x


seminggu dan dalam kondisi normal PGP melaporkan hasil pemeriksaan secara
lisan 1x / hari.

3. Membuat foto dokumentasi tower-tower yang diinspeksi dan foto dokumentasi


kondisi abnormal yang ditemukan dan dilampirkan pada laporan Ground Patrol.

4. Menjaga kebersihan halaman tapak tower.

5. Melakukan penebangan/ pemangkasan pohon/ tumbuhan yang masuk dalam


daerah bebas/ ROW dan yang tidak menimbulkan ganti rugi dengan pengawasan
dari pihak PLN.

6. Melakukan penebangan/ pemangkasan pohon/ tumbuhan di luar ROW yang


berpotensi menimbulkan gangguan dan yang tidak menimbulkan ganti rugi
dengan pengawasan dari pihak PLN.

7
PENGAWASAN DAN ASESMEN SUTT/SUTET

7. Bila Petugas Ground Patrol menemukan kondisi khusus/ emergency seperti


tanah tapak tower longsor, besi siku kaki tower bengkok/ putus, konduktor putus,
tower roboh dll, maka PGP harus melaporkan secara lisan selambat-lambatnya 1
jam setelah diketahui dan dilengkapi dengan data yang rinci dan akurat disertai
foto kondisi maksimum 1x24 jam kepada koordinator PGP dan pengawas
pekerjaan/ Direksi Pekerjaan.

8. Mencegah dan segera melaporkan kepada Koordinator PGP dan Pengawas


Pekerjaan PLN jika terdapat kegiatan yang berada didalam ruang bebas
SUTT/SUTET seperti bermain layang-layang, kegiatan olahraga, mendirikan
bangunan, mendirikan antena radio, dll.

9. Membantu pihak Internal (PLN) dalam melaksanakan perbaikan/ penggantian


komponen SUTT/SUTET seperti besi siku tower atau kawat grounding yang
hilang/ rusak atau melaksanakan pencarian penyebab gangguan SUTT/SUTET.

10. Memeriksa dan melakukan pendekatan yang baik kepada penduduk setempat
untuk menghentikan pemotongan tanaman tumbuh oleh yang diperkirakan akan
menimpa konduktor atau kegiatan lain yang dapat membahayakan
SUTT/SUTET, kemudian segera mencatat dan melaporkan kepada Koordinator
PGP dan Pengawas Pekerjaan.

Tugas dan tanggung jawab Koordinator Petugas Ground Patrol yaitu sebagai berikut:

1. Mengawasi dan bertanggung jawab terhadap pelaksanaan dan kualitas


pekerjaan Petugas Ground Patrol.

2. Merekap hasil inspeksi PGP (checklist dan foto dokumentasi).

3. Membuat laporan Ground Patrol dan melaporkannya ke pengawas pekerjaan


dan Direksi Pekerjaan setiap 1 bulan.

4. Mengkoordinir dan mengatur jadwal pelaksanaan pekerjaan Petugas Ground


Patrol baik untuk pekerjaan rutin atau sesuai permintaan pihak PLN.

2.2 Climb Up Inspection

Climb Up Inspection adalah pekerjaan pemeriksaan SUTT/SUTET secara visual dalam


keadaan bertegangan yang dilakukan terhadap seluruh komponen SUTT/SUTET dengan
cara memanjat dan jika diperlukan dapat dilakukan pengukuran/ pemeriksaan lebih detil.

2.2.1 Sistem Pelaksanaan Climb Up Inspection

Poin-poin sistem pelaksanaan Climb Up Inspection yaitu sebagai berikut:

1. Setiap tower dilakukan pemeriksaan secara Climb Up minimal 1x per 5 tahun


atau tidak terbatas sesuai dengan kerawanan dan kondisi SUTT/SUTET
setempat.

2. Petugas yang melaksanakan Climb Up Inspection (CUI) disebut Climber.

8
PENGAWASAN DAN ASESMEN SUTT/SUTET

3. Petugas Climb Up Inspection dapat dilaksanakan oleh regu PDKB atau petugas
yang berkompeten dan bersertifikasi pengenalan PDKB dan Climb Up Inspection.

4. Untuk memenuhi standar K3, maka setiap climber yang melaksanakan CUI
diawasi oleh seorang pengawas pekerjaan dan seorang pengawas K3.

5. Peralatan kerja Climb Up Inspection:

• Peralatan Kerja terdiri dari: teropong, ranging meter, kamera digital.

• Checklist pemeriksaan dan alat tulis.

• Tanda Pengenal.

• Peralatan K3 (sesuai dengan kebutuhan).

6. Metode pelaksanaan Climb Up Inspection terdapat 2 pilihan sistem pelaksanaan,


yaitu sistem pelaksanaan Climb Up Inspection (CUI) dengan climber dari pihak
luar dan Climb Up Inspection (CUI) dengan climber dari PLN. Sistem
pelaksanaan CUI dengan climber dari pihak luar dapat dilihat pada tabel dibawah
ini.

Gambar 2-5 Sistem Pelaksanaan Climb Up Inspection (CUI) dengan climber dari pihak luar

9
PENGAWASAN DAN ASESMEN SUTT/SUTET

Keterangan:

- Penanggung jawab setiap level disesuaikan dengan proses bisnis Climb Up


Inspection masing-masing unit wilayah PLN yang menggunakan Climber dari
pihak luar. Tiap-tiap unit wilayah PLN menerjemahkan tugas dan tanggung
jawab tersebut ke dalam struktur organisasi di masing-masing unit.
- Pada pihak internal, posisi level 1 (Evaluasi) dapat diisi oleh Asman
Enjiniring, Asman Renev atau Asman Penyaluran sesuai dengan proses
bisnis CUI masing-masing unit PLN.
- Pada pihak internal, posisi level 2 (Tindak Lanjut) dapat diisi oleh Asman
Pemeliharaan atau Asman Penyaluran sesuai dengan proses bisnis CUI
masing-masing unit PLN.

Sedangkan Sistem pelaksanaan CUI dengan climber dari PLN dapat dilihat pada tabel
dibawah ini.

Gambar 2-6 Sistem Pelaksanaan Climb Up Inspection (CUI) dengan climber dari PLN

Keterangan:

- Penanggung jawab setiap level disesuaikan dengan proses bisnis CUI


masing-masing unit wilayah PLN yang menggunakan Climber dari internal
PLN. Tiap-tiap unit wilayah PLN menerjemahkan tugas dan tanggung jawab
tersebut ke dalam struktur organisasi di masing-masing unit.

10
PENGAWASAN DAN ASESMEN SUTT/SUTET

- Pada level 2 (Koordinator PDKB) dapat diisi oleh Asman PDKB atau Supv.
PDKB sesuai dengan proses bisnis CUI masing-masing unit PLN.
- Pada level 3 (Evaluasi) dapat diisi oleh Asman Enjiniring, Asman Renev atau
Asman Penyaluran sesuai dengan proses bisnis CUI masing-masing unit
PLN.
- Pada level 4 (Tindak Lanjut) dapat diisi oleh Asman Pemeliharaan atau
Asman Penyaluran sesuai dengan proses bisnis CUI masing-masing unit
PLN.

2.2.2 Tugas dan Tanggung Jawab

Tugas dan tanggung jawab Climber yaitu sebagai berikut:

1. Melakukan pemeriksaan komponen-komponen SUTT/SUTET antara lain sebagai


berikut:

1) Member / Besi Siku / Bracing 17) Spacer pada Penghantar *

2) Plat sambungan rangka 18) Spacer pada Jumper


Konduktor *
3) Mur dan Baut Tower
19) Jumper Konduktor
4) Cat / Galvanisasi
20) Armor rod
5) Baut panjat
21) Vibration Damper
6) Aviation Lamp *
22) Counter weight *
7) Lampu Indikator Tower *
23) Kawat tanah / GSW / OPGW
8) Kawat Grounding *
24) Konduktor penghubung kawat
9) Insulator tanah *

10) Ikatan Insulator 25) Jumper GSW

11) Fitting Insulator 26) Bola Rambu *

12) Arching Horn 27) Box joint OPGW *

13) Suspension / Tension Clamp 28) ROW

14) Konduktor 29) TLA (Transmission Line


Arrester)*
15) Midspan Compression Joint *

16) Repair Sleeve *

Keterangan: *) jika ada

11
PENGAWASAN DAN ASESMEN SUTT/SUTET

2. Mengisi check list Climb Up Inspection sesuai dengan kondisi SUTT/SUTET


yang sebenarnya. Checklist Climb Up Inspection dapat dilihat pada Buku
Pedoman Pemeliharaan Saluran Udara Tegangan Tinggi dan Ekstra Tinggi.
3. Membuat foto dokumentasi tower-tower yang diinspeksi dan foto dokumentasi
kondisi abnormal yang ditemukan.
4. Melaporkan hasil inspeksi kepada Manajer unit PLN masing-masing.

3 ASESMEN ANCAMAN PADA SUTT/SUTET

Asesmen ancaman pada SUTT/SUTET adalah analisa dan penilaian suatu kondisi yang
menjadi ancaman tower / tiang. Asesmen ancaman terdiri dari asesmen ancaman kondisi
lingkungan dan asesmen ancaman kondisi pondasi. Pelaksanaan asesmen ancaman
pada SUTT / SUTET ini dibagi menjadi 2 yaitu:

1. Asesmen rutin yaitu asesmen ancaman pada SUTT/SUTET yang


dilaksanakan rutin sekali dalam lima tahun.

2. Asesmen kondisional yaitu asesmen yang dilaksanakan jika terdapat


perubahan kondisi pada lingkungan atau pondasi tower. Informasi
perubahan kondisi terkait ancaman kondisi lingkungan dan pondasi ini
didapat dari inspeksi Ground Patrol pada subsistem struktur tower.

Asesmen ancaman pada SUTT/SUTET dilaksanakan oleh fungsi pemeliharaan jaringan/


sipil atau fungsi evaluasi jaringan/ sipil di masing-masing unit/ wilayah PLN.

3.1 Asesmen Ancaman Kondisi Lingkungan

Asesmen ancaman kondisi lingkungan adalah penilaian kondisi tower dilihat dari
lingkungan tower (lereng dan tebing, jejak gangguan, aliran sungai, posisi sungai,
gangguan eksternal, tanah dan batuan, dan vegetasi penutup). Asesmen ini dilaksanakan
untuk menindaklanjuti kondisi abnormal lingkungan tower dan sebagai dasar usulan
penanggulangan/ perbaikan lingkungan tower. Asesmen ancaman kondisi lingkungan
terdiri dari 7 komponen yaitu lereng dan tebing, jejak gangguan, aliran sungai, posisi
sungai, gangguan eksternal, tanah dan batuan, dan vegetasi penutup. Standar asesmen
ancaman kondisi lingkungan untuk tower jenis Lattice maupun tower jenis Steel Pole
dapat dilihat pada tabel di bawah ini:

Tabel 3-1 Standar asesmen ancaman kondisi lingkungan

No Komponen Pemeriksaan Nilai

1 Ketinggian tebing (y1) > 30 meter 7

2 Ketinggian tebing (y2) > 30 meter 7


LERENG &
3 Ketinggian tebing (y1) 21 - 30 meter 5
TEBING
4 Ketinggian tebing (y2) 21 - 30 meter 5

5 Ketinggian tebing (y1) 11 - 20 meter 3

12
PENGAWASAN DAN ASESMEN SUTT/SUTET

No Komponen Pemeriksaan Nilai

6 Ketinggian tebing (y2) 11 - 20 meter 3

7 Ketinggian tebing (y1) 5 - 10 meter 1

8 Ketinggian tebing (y2) 5 - 10 meter 1

9 sudut kemiringan (a1) lereng > 60 Derajat 7

10 sudut kemiringan (a2) lereng > 60 Derajat 7

11 sudut kemiringan (a1) lereng 41 - 60 Derajat 5

12 sudut kemiringan (a2) lereng 41 - 60 Derajat 5

13 sudut kemiringan (a1) lereng 21 - 40 Derajat 3

14 sudut kemiringan (a2) lereng 21 - 40 Derajat 3

15 sudut kemiringan (a1) lereng 11 - 20 Derajat 1

16 sudut kemiringan (a2) lereng 11 - 20 Derajat 1

17 Jarak kaki tower dengan dasar tebing (x1) < 1 meter 6

18 Jarak kaki tower dengan jurang tebing (x2) < 1 meter 6

19 Jarak kaki tower dengan dasar tebing (x1) 1 - 10 meter 5

20 Jarak kaki tower dengan jurang tebing (x2) 1 - 10 meter 5

21 Jarak kaki tower dengan dasar tebing (x1) 11 - 20 meter 4

22 Jarak kaki tower dengan jurang tebing (x2) 11 - 20 meter 4

23 Jarak kaki tower dengan dasar tebing (x1) 21 - 30 meter 3

24 Jarak kaki tower dengan jurang tebing (x2) 21 - 30 meter 3

25 Jarak kaki tower dengan dasar tebing (x1) 31 - 40 meter 2

2
26 Jarak kaki tower dengan jurang tebing (x2) 31 - 40 meter

27 Jejak longsoran radius < 7 meter dari pondasi 30

28 Genangan air permanen dan bukan design tower tersebut 10


JEJAK
GANGGUAN
29 Retakan terbuka 10

30 Terdapat jejak erosi pada radius 7 meter dari pondasi 8

13
PENGAWASAN DAN ASESMEN SUTT/SUTET

No Komponen Pemeriksaan Nilai

31 Terdapat mata air pada radius 7 meter dari pondasi 8

32 Genangan air temporer 5

33 Retakan tertutup (Kecuali tanah sawah kering) 5

34 Jarak terdekat kaki tower dengan bibir sungai ≤ 2 meter 51

35 Jarak terdekat kaki tower dengan bibir sungai 2 - 5 meter 50

36 Jarak terdekat kaki tower dengan bibir sungai 6 - 10 meter 13

37 Jarak terdekat kaki tower dengan bibir sungai 11 -20 meter 8

Jarak terdekat kaki tower dengan bibir sungai 21 - 30


38 6
meter

Jarak terdekat kaki tower dengan bibir sungai 31 - 40


39 4
meter

Lebar sungai > 10 meter ( Diukur jika terdapat sungai


40 ALIRAN 13
dengan jarak ≤ 10m dari tower )
SUNGAI
Lebar sungai 6 - 10 meter ( Diukur jika terdapat sungai
41 10
dengan jarak ≤ 10m dari tower )

Lebar sungai 3 - 5 meter ( Diukur jika terdapat sungai


42 3
dengan jarak ≤ 10m dari tower )

Arus sungai Cepat ( ≥1 m/s, diukur jika terdapat sungai


43 5
dengan jarak ≤ 10m dari tower )

Arus sungai Sedang ( 0,5 m/s - 1 m/s, diukur jika terdapat


44 3
sungai dengan jarak ≤ 10m dari tower )

1
45 Arus sungai Lambat ( < 0,5 m/s, diukur jika terdapat
sungai dengan jarak ≤ 10m dari tower )

46 Luar 10
POSISI
47 Lurus 5
SUNGAI
48 Dalam 1

49 Penimbunan sampah 25
GANGGUAN
50 Bangunan di halaman tower 20
EKSTERNAL
51 Aktivitas penduduk / pihak luar di halaman tower 15

14
PENGAWASAN DAN ASESMEN SUTT/SUTET

No Komponen Pemeriksaan Nilai

52 Tanah Organik, gambut 16

53 Tanah urug, Sirtu 15

54 Tanah merah, berpasir 13

55 Tanah merah, lempung 11

56 Tanah berkerikil 10
TANAH &
BATUAN
57 Tanah batu berpasir 8

58 Tanah berbatu 6

59 Batuan campur tanah 5

60 Batuan kali / Cadas 3

61 Batuan Granit 1

62 Tanah garapan basah (sawah) 5

63 Tanah terbuka 4
VEGETASI
64 Tanah garapan kering 3
PENUTUP
65 Pohonan Keras 2

66 Rumput alang-alang 1

Untuk memperjelas pemeriksaan komponen lereng & tebing, posisi sungai dan aliran
sungai pada tabel diatas maka dapat dilihat pada gambar dibawah ini.

15
PENGAWASAN DAN ASESMEN SUTT/SUTET

Gambar 3-1 Contoh kondisi dan ukuran lereng dan tebing

Gambar 3-2 Contoh kondisi posisi sungai dalam (kiri) dan kondisi posisi sungai luar (kanan)

Penilaian asesmen ancaman kondisi lingkungan sesuai tabel diatas dilakukan dengan
pemeriksaan secara visual dan pengukuran lalu mengisi checklist asesmen ancaman
kondisi lingkungan seperti gambar dibawah ini (untuk lebih jelasnya dapat dilihat pada
lampiran).

16
PENGAWASAN DAN ASESMEN SUTT/SUTET

?@=?/ABC;1DC=C2=-1D-?D2D-1/E-6BCB1AB-:/F-:D-1CF;;GCF;=;

!"!#$%&'##( !!!!!!!!!!!!! )$**#+#)$*,*#(#-----------------.. )&/&#01"12&3/!!%##( @2> "#$ %& '()*+ ,*-.*/ 0( .*1*)

4.#*4512#+#*&!%6#(#---------------.. >2S $#2

7.#84"94%1%#04/&/&#):%6!& ;.#84"94%1%#<121%6#=!%#*1>&%6 ?.#*4'!@# &@!&

01"12&3/!!% A4>4' &@!& 01"12&3/!!% A4>4' &@!& ;*,'.1($.'$1/*"7*(!(1DH)H?H6H=HIH:1J

'3*/ 45 81'&%66&!%#*1>&%6#(
'3/36 7 KK 89+(:,,(*: +9.(:, ;<4& = >5 -9+9/ ? KKKKKKKKKKKKKKKKKK
$*@*- 4 89+(:,,(*: +9.(:, ;<4& A5 # >5 -9+9/ 7
A.#84"94%1%#7@&2!%#):%6!& 89+(:,,(*: +9.(:, ;<4& 45 # A5 -9+9/ > KK

01"12&3/!!% A4>4' &@!& 89+(:,,(*: +9.(:, ;<4& 7 # 45 -9+9/ 4 ?.#8@!/&B&3!/&#*&%63!'#7%C!"!%

D!2!3#8!3&#*4512#=1%6!%#A&>&2#):%6!&#( 89+(:,,(*: +9.(:, ;<A& = >5 -9+9/ ? H'&!?$PR'")$T$53 8EF*F)

B*/*C +9/09C*+ C*C( +D19/ 09:,*: .(.(/


74 89+(:,,(*: +9.(:, ;<A& A5 # >5 -9+9/ 7 H'&!?$:R'")$0=$2$53 G7)07H7
63:,*( E A -9+9/
KK
B*/*C +9/09C*+ C*C( +D19/ 09:,*: .(.(/
75 89+(:,,(*: +9.(:, ;<A& 45 # A5 -9+9/ > H'&!?$PR'")$3$2$06 7I7
63:,*( A # 7 -9+9/
B*/*C +9/09C*+ C*C( +D19/ 09:,*: .(.(/
4> 89+(:,,(*: +9.(:, ;<A& 7 # 45 -9+9/ 4 @DCBA1DCC=CC2=-1J
63:,*( F # 45 -9+9/ -----------.
KK
B*/*C +9/09C*+ C*C( +D19/ 09:,*: .(.(/
G ):=:'#81"&2&%6!%#( F.#$/:@#=!%#)!2!%#(
63:,*( 44 #A5 -9+9/
B*/*C +9/09C*+ C*C( +D19/ 09:,*: .(.(/ 6303+ C9-(/(:,*: ;*4&
F ?
63:,*( A4 # >5 -9+9/ 0*6*/ @9/9:, = F5 $9/*H*+
0 HUFV@Q@F$W
B*/*C +9/09C*+ C*C( +D19/ 09:,*: .(.(/ 6303+ C9-(/(:,*: ;*4&
I 7
63:,*( >4 # I5 -9+9/ 0*6*/ @9/9:, I5 # F5 $9/*H*+ KKKKKKKKK
6303+ C9-(/(:,*: ;*4& KK
<1>!2#):%6!&#( >
0*6*/ @9/9:, A5 # I5 $9/*H*+
'9.*/ 63:,*( = 45 -9+9/ ;$(3C3/ .(@* 6 8XFL@Y@P@F$W
6303+ C9-(/(:,*: ;*4&
+9/0*J*+ 63:,*( 09:,*: H*/*C E 45- 0*/( 4> 4
0*6*/ @9/9:, 45 # A5 $9/*H*+
+D19/& KKKKKKKKK
6303+ C9-(/(:,*: ;*A&
'9.*/ 63:,*( F # 45 -9+9/ 45 KK ?
0*6*/ @9/9:, = F5 $9/*H*+
'9.*/ 63:,*( > # 7 -9+9/ ;$(3C3/ .(@*
6303+ C9-(/(:,*: ;*A&
+9/0*J*+ 63:,*( 09:,*: H*/*C E 45- 0*/( > 7 =
0*6*/ @9/9:, I5 # F5 $9/*H*+
+D19/& KK
6303+ C9-(/(:,*: ;*A&
81C19!'!%#72:/#):%6!&#( >
0*6*/ @9/9:, A5 # I5 $9/*H*+ KKKKKKKKKKKKKKKKKKKKKGG
6303+ C9-(/(:,*: ;*A&
2/36 63:,*( "9J*+ ; K4 -L6& 7 4
0*6*/ @9/9:, 45 # A5 $9/*H*+

2/36 63:,*( M90*:,; 5N7 -L6 # 4 -L6& > KK D!2!3#8!3&#*4512#=1%6!%#*1>&%6 D.#*&"#01"12&3/!

B*/*C C*C( +D19/ 09:,*: +9.(:,


2/36 63:,*( '*-.*+ ;E 5N7 -L6& 4 F QDR Q*-* S*:0* S*:,*:
;O4& P 4 -9+9/ ;0(.(.(/ +9.(:,&
!"!#$#!#%$&'()"$*)+,!+$&)-%+,
J.#84"94%1%#K!%66:!%#,3/'12%!@ 5 0
./01$0$2$03$4)&)"
!"!#$#!#%$&'()"$*)+,!+$&)-%+,
!"!#$%&''( )*+*, -$.'$ 7 KK 6
./01$63$2$03$4)&)"
!"!#$#!#%$&'()"$*)+,!+$&)-%+,
8)+%4-9+!+$:!4;!< 65 = =
./01$63$2$=3$4)&)"
!"!#$#!#%$&'()"$*)+,!+$&)-%+,
>!+,9+!+$*%$<!?!4!+$&'()" 63 KK 6 /012!(3!,'45$
./01$=3$2$73$4)&)"
@#&%A%&!:$;)+*9*9#$B$;%<!#$?9!"C$*% !"!#$#!#%$&'()"$*)+,!+$&)-%+,
05 E F'G F!4! H!+*!$H!+,!+
<!?!4!+$&'()" ./61$D$0$4)&)"$.*%-%-%"$&)-%+,1
!"!#$#!#%$&'()"$*)+,!+$&)-%+,
601/*"7*(!(18!9'%1:'(335'( 5 0
./61$0$2$03$4)&)"
!"!#$#!#%$&'()"$*)+,!+$&)-%+, 8)+)+&9!+$:%:%$;)4)"%#:!!!+$*%?%<!&$;!*!
!"!#$%&''( )*+*, -$.'$ 7 KK
./61$63$2$03$4)&)" ,!4-!"$-)"%#9&$W
)I!#$?'+,:'"!+$"!*%9:$D$J$4)&)"$*!"% !"!#$#!#%$&'()"$*)+,!+$&)-%+,
=3 KK =
;'+*!:% ./61$63$2$=3$4)&)"
L)+!+,!+$!%"$;)"4!+)+$*!+$-9#!+ !"!#$#!#%$&'()"$*)+,!+$&)-%+, .F'G H'()"$Q)R%?1
03 KK 6
*):%,+$&'()"$&)":)-9& ./61$=3$2$73$4)&)"
M)&!#!+$&)"-9#! 03 KK :01/*"7*(!(1;'('41<'(1)',5'(
H)"*!;!&$I)I!#$)"':%$;!*!$"!*%9:$J$4)&)"
N KK !"!#$%&''( )*+*, -$.'$
*!"%$;'+*!:% D P%:%$@2> )
H)"*!;!&$4!&!$!%"$;!*!$"!*%9:$J$4)&)"
N KK H!+!<$O",!+%#C$,!4-9& 0E
*!"%$;'+*!:%
L)+!+,!+$!%"$&)4;'")" 5 KK H!+!<$9"9,C$P%"&9 05
M)&!#!+$&)"&9&9;$.Q)R9!?%$&!+!<$:!(!<
5 KK H!+!<$4)"!<C$-)";!:%" 0=
#)"%+,1 P%:%$V2@ P%:%$>2S
H!+!<$4)"!<C$?)4;9+, 00
=01/*"7*(!(1>!3!,'&$1 !(5,57 H!+!<$-)"#)"%#%? 03 KK
!"!#$%&''( )*+*, -$.'$ H!+!<$-!&9$-)";!:%" N
H!+!<$,!"!;!+$-!:!<$.:!(!<1 5 H!+!<$-)"-!&9 E
H!+!<$&)"-9#! 7 >!&9!+$R!4;9"$&!+!< 5 P%:%$S2V
6 ?
H!+!<$,!"!;!+$#)"%+, = KK >!&9!+$#!?%B$S!*!: =
8'<'+!+$Q)"!: 6 >!&9!+$L"!+%& 0
.F'G H'()"$>):!"1
M94;9&$!?!+,2!?!+, 0

Gambar 3-3 Checklist Asesmen Ancaman Kondisi Lingkungan

Dari hasil asesmen ancaman kondisi lingkungan tower sesuai table 3 di atas, maka
didapat rekomendasi tindak lanjut berupa pemantauan dan perbaikan. Standar tindak
lanjut pemantauan/ pengawasan berdasarkan nilai ancaman adalah sebagai berikut:

• 13-20 : pemantauan rutin bulanan


• 21-30 : pemantauan rutin 2 mingguan
• 31-50 : pemantauan rutin mingguan

17
PENGAWASAN DAN ASESMEN SUTT/SUTET

• > 50 : pemantauan rutin harian

Sedangkan standar untuk tindak lanjut perbaikan yaitu:

• 0-12 : aman
• 13-50 : waspada (lakukan perbaikan apabila diperlukan, maksimal 6 bulan)
• > 50 : kritis (lakukan perbaikan maksimal 1 bulan)

3.2 Asesmen Ancaman Kondisi Pondasi

Asesmen ancaman kondisi pondasi adalah penilaian kondisi tower dilihat dari pondasi
tower. Asesmen ini dibagi 2 yaitu asesmen ancaman kondisi pondasi tower tipe Lattice
dan asesmen ancaman kondisi pondasi tower tipe Steel Pole.

3.2.1 Asesmen Ancaman Kondisi Pondasi Tower Lattice

Pemeriksaan dalam asesmen ini terdiri dari 3 komponen yaitu Stub, Chimney dan Balok
Kopel. Standar asesmen ancaman kondisi pondasi untuk tower Lattice dapat dilihat pada
tabel di bawah ini:
Tabel 3-2 Standar asesmen ancaman kondisi pondasi tower Lattice

NO KOMPONEN PEMERIKSAAN NILAI

1 Kelainan pada salah satu kaki stub (Bengkok, defleksi, dsb). 50

2 Ada perubahan jarak antar kaki, diagonal dan level. 50

3 Korosi pada permukaan. 10


STUB
4 Warna galvanis sudah berubah (hitam). 5

Ada air, tanah, jerami dengan jarak kurang dari 10 cm dari


5 5
permukaan chimney.

6 Korosi dan penipisan dimensi. 15

7 Pecah / Gompal sampai terlihat tulangan. 40


CHIMNEY
8 Retak. 30

BALOK
9 Pecah. 10
KOPEL*

Keterangan: *) jika ada

Untuk memperjelas tabel diatas, contoh gambar kondisi sesuai tabel diatas dapat dilihat
pada lampiran. Penilaian asesmen ancaman kondisi pondasi tower Lattice sesuai tabel
diatas dilakukan dengan pemeriksaan secara visual dan atau pengukuran lalu mengisi
checklist asesmen ancaman kondisi pondasi tower Lattice seperti gambar dibawah ini
(untuk lebih jelasnya dapat dilihat pada lampiran).

18
PENGAWASAN DAN ASESMEN SUTT/SUTET

8H$8ZF$.8)":)"'1

?@=?/ABC;1DC=C2=-1D-?D2D-1/E-6BCB1 E-6DCB1;EM=N1AD;B?=

-'"'1F($,11J1KKKKKKKKKKKK1111111111111111CF;;1G1CF;=;1J1KKKKKKKKKKKKKK0
-*01;*L!#1G1;$'(31J1KKKK

-E /E2 E-=- FNDBD-1 =2=NB/CDD- )E)E; -BADB1DC=C2=-

Q)?!%+!+$;!*!$:!?!<$:!&9$#!#%$:&9-$.>)+,#'#C$*)_?)#:%C
0 53 KKKKGG
*:-1

6 @*!$;)"9-!<!+$I!"!#$!+&!"$#!#%C$*%!,'+!?$*!+$?)A)?G 53 KKKKGG

= Y!"+!$,!?A!+%:$:9*!<$-)"9-!<$.<%&!41 5
PH^>
7 Q'"':%$;!*!$;)"49#!!+ 03 KKKKGG

5 Q'"':%$*!+$;)+%;%:!+$*%4)+:% 05

@*!$!%"C$&!+!<C$I)"!4%$*)+,!+$I!"!#$#9"!+,$*!"%$03$R4$*!"%
E 5 KKKKGG
;)"49#!!+$R<%4+)`

J 8)R!<$B$L'4;!?$:!4;!%$&)"?%<!&$&9?!+,!+ 73
SaU]FXb KKKKGG
N M)&!# =3

[ >@ZOQ$QO8XZ\1 8)R!< 03 KKKKGG

;E;DA1-BADB1DC=C2=- KKKKGG

@'&$.1D&!&"!(1J KKKKGG
/!,!#'(3'(1J
2$\1$ %#!$@*!

/ADCBIB/DCB1;B-:/D;1D-?D2D- ;B-6D/D-1J =-:DMDCD-1J

H'&!?$:R'")$T$E3 QMUHUP

H'&!?$:R'")$=0$2$E3 Y@P8@V@ KKKKGG KKKKGG

H'&!?$PR'")$3$2$=3 @]@F

])+,)&!<9%C $$$$$$$$$$$$$$$$$$$$$$$$$$$$$KKKKKCKKKKKKKKKKKKKK
KKKKKKKKKKKKKKKKG 8)4)"%#:!

.KKKKKKKKKKKKKKG1 $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$.KKKKKKKKKKKKKKKGG1

Gambar 3-4 Checklist asesmen ancaman kondisi pondasi tower Lattice

Dari hasil asesmen ancaman kondisi pondasi tower Lattice, maka didapat rekomendasi
tindak lanjut berupa pemantauan dan perbaikan. Standar tindak lanjut pemantauan
berdasarkan nilai ancaman adalah sebagai berikut:

• 31-60 : pemantauan rutin bulanan


• > 60 : pemantauan rutin harian

Sedangkan untuk standar tindak lanjut perbaikan yaitu:

• 0-30 : aman
• 31-60 : waspada (lakukan perbaikan apabila diperlukan, maksimal 6 bulan)
• > 60 : kritis (lakukan perbaikan maksimal 1 bulan)

19
PENGAWASAN DAN ASESMEN SUTT/SUTET

3.2.2 Asesmen Ancaman Kondisi Pondasi Tower Steel Pole

Pemeriksaan dalam asesmen ini terdiri dari 2 komponen yaitu Chimney dan Angkur.
Standar asesmen ancaman kondisi pondasi untuk tower Steel Pole dapat dilihat pada
tabel di bawah ini:

Tabel 3-3 Standar asesmen ancaman kondisi pondasi tower steel pole

NO KOMPONEN PEMERIKSAAN BOBOT

1 Mur Kurang Kencang 50

2 Terjadi korosi dan penipisan dimensi 40

3 ANGKUR Korosi pada permukaan 15

4 Warna galvanis sudah berubah (hitam) 10

5 Drat Kurang Panjang (min 2 ulir) 10

6 Pecah/ Gompal sampai terlihat tulangan 30


CHIMNEY
7 Retak 20

Untuk memperjelas tabel diatas, contoh gambar kondisi sesuai tabel diatas dapat dilihat
pada lampiran. Penilaian asesmen ancaman kondisi pondasi tower Steel Pole sesuai
tabel diatas dilakukan dengan pemeriksaan secara visual lalu mengisi checklist asesmen
ancaman kondisi pondasi tower Steel Pole seperti gambar dibawah ini (untuk lebih
jelasnya dapat dilihat pada lampiran).

Dari hasil asesmen ancaman kondisi pondasi tower Steel Pole, maka didapat
rekomendasi tindak lanjut berupa pemantauan dan perbaikan. Standar tindak lanjut
pemantauan berdasarkan nilai ancaman adalah sebagai berikut:

• 31-60 : pemantauan rutin bulanan


• > 60 : pemantauan rutin harian

Sedangkan untuk standar tindak lanjut perbaikan yaitu:

• 0-30 : aman
• 31-60 : waspada (lakukan perbaikan apabila diperlukan, maksimal 6 bulan)
• > 60 : kritis (lakukan perbaikan maksimal 1 bulan)

20
PENGAWASAN DAN ASESMEN SUTT/SUTET

8H$8ZF$.8)":)"'1

?@=?/ABC;1DC=C2=-1D-?D2D-1/E-6BCB1 E-6DCB1;EM=N1C;==A1 EA=

-'"'1F($,11J1KKKKKKKKKKKK1111111111111111CF;;1G1CF;=;1J1KKKKKKKKKKKKKK0 -*01;*L!#1G1;$'(31J1KKKK

-E /E2 E-=- =2=NB/CDD- )E)E; -BADB1DC=C2=-

0 ]9"$Q9"!+,$Q)+R!+, 53 KKKKGG

6 V"!&$Q9"!+,$8!+I!+,$.4%+$6$9?%"1 03 KKKKGG

= @FLQ^M H)"I!*%$#'"':%$*!+$;)+%;%:!+$*%4)+:% 73

7 Q'"':%$;!*!$;)"49#!!+ 05 KKKKGG

5 Y!"+!$,!?A!+%:$:9*!<$-)"9-!<$.<%&!41 03

E 8)R!<B$L'4;!?$:!4;!%$&)"?%<!&$&9?!+,!+ =3
SaU]FXb KKKKGG
J M)&!# 63

;E;DA1-BADB1DC=C2=- KKKKGG

@'&$.1D&!&"!(1J KKKKGG

/ADCBIB/DCB1;B-:/D;1D-?D2D- ;B-6D/D-1J =-:DMDCD-1J


H'&!?$:R'")$T$E3 QMUHUP
H'&!?$:R'")$=0$2$E3 Y@P8@V@ KKKKGG KKKKGG
H'&!?$PR'")$3$2$=3 @]@F

])+,)&!<9%C $$$$$$$$$$$$$$$$$$$$$$$$$$$$$KKKKKCKKKKKKKKKKKKKK
KKKKKKKKKKKKKKKKG 8)4)"%#:!

.KKKKKKKKKKKKKKG1 $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$.KKKKKKKKKKKKKKKGG1

Gambar 3-5 Checklist asesmen ancaman kondisi pondasi tower steel pole

4 ASESMEN KONDISI KOMPONEN SUTT/SUTET

Asesmen kondisi komponen SUTT/SUTET terdiri dari 6 sub sistem yaitu: Current
Carrying, Insulation, Structure, Junction, Protection dan Monitoring. Sub sistem Current
Carrying, Insulation, Structure dan Junction bersifat primary, sedangkan sub sistem
Protection dan Monitoring bersifat secondary. Asesmen ini dilaksanakan setelah
mendapat inputan kondisi abnormal dari laporan hasil inspeksi Ground Patrol atau Climb
Up Inspection yang periodenya sesuai yang diatur pada SK Dir 114.K/DIR/2010 tentang
Buku Pedoman Pemeliharaan Saluran Udara Tegangan Tinggi dan Ekstra Tinggi. Dalam
asesmen ini untuk menentukan prioritas penanganan dan rekomendasi tindak lanjut,
maka diperlukan jenis dan index kondisi komponen SUTT/SUTET. Berdasarkan standar
dari berbagai sumber maka jenis kondisi komponen SUTT/SUTET dibagi menjadi 3 yaitu:

21
PENGAWASAN DAN ASESMEN SUTT/SUTET

Tabel 4-1 Standar justifikasi kondisi komponen SUTT/SUTET dan rekomendasi tindak
lanjutnya

Index Kondisi Jenis Kondisi Rekomendasi Tindak Lanjut

1 Kritis Perbaikan segera dan pemantauan rutin

Pemantauan dan perbaikan seperlunya


6 Waspada
maksimal 6 bulan

9 Aman Lanjutkan pemeliharaan rutin

Gambar 4-1 Dasar justifikasi dan asesmen kondisi komponen SUTT/SUTET

4.1 Sub Sistem Current Carrying

Sub sistem Curent Carrying terdiri dari komponen konduktor dan jumper konduktor.

4.1.1 Konduktor
Tabel 4-2 Asesmen kondisi konduktor melalui inspeksi GP mingguan

Rekomendasi Tidak Lanjut


Jenis Index
No. Kondisi
Inspeksi Kondisi
Tindakan Jangka Waktu

1 Normal 9 - -

Ground 2 - 6 - -
Patrol
Mingguan 3 Rantas Perbaikan
1 Segera
4 Mekar Perbaikan

22
PENGAWASAN DAN ASESMEN SUTT/SUTET

Tabel 4-3 Asesmen kondisi konduktor melalui inspeksi Climb Up

Rekomendasi Tidak Lanjut


Jenis Index
No. Kondisi
Inspeksi Kondisi
Tindakan Jangka Waktu

1 Normal 9 - -

2 - 6 - -
Climb Up
3 Rantas Perbaikan
1 Segera
4 Mekar Perbaikan

4.1.2 Jumper Konduktor


Tabel 4-4 Asesmen kondisi jumper konduktor melalui inspeksi Climb Up

Rekomendasi Tidak Lanjut


Jenis Index
No. Kondisi
Inspeksi Kondisi
Tindakan Jangka Waktu

1 Normal * 9 - -

2 - 6 - -
Climb Up
3 Rantas Perbaikan
1 Segera
4 Mekar Perbaikan

Keterangan: *) Normal terpasang atau normal tidak terpasang

Tabel 4-5 Asesmen kondisi jumper konduktor melalui inspeksi GP mingguan

Rekomendasi Tidak Lanjut


Jenis Index
No. Kondisi
Inspeksi Kondisi
Tindakan Jangka Waktu

1 Normal * 9 - -

Ground 2 - 6 - -
Patrol
Mingguan 3 Rantas Perbaikan
1 Segera
4 Mekar Perbaikan

Keterangan: *) Normal terpasang atau normal tidak terpasang

23
PENGAWASAN DAN ASESMEN SUTT/SUTET

4.1.3 Jumper Joint


Tabel 4-6 Asesmen kondisi jumper joint melalui inspeksi Climb Up

Rekomendasi Tidak Lanjut


Jenis Index
No. Kondisi
Inspeksi Kondisi
Tindakan Jangka Waktu

1 Normal * 9 - -

2 Level korosi 40 % - 60 % 6 Penggantian 6 bulan

3 Kendor Perbaikan
Climb Up
4 Lepas Perbaikan
1 Segera
Perbaikan /
5 Membara
Penggantian

6 Level korosi > 60 % Penggantian

Keterangan: *) Normal terpasang atau normal tidak terpasang

4.1.4 Midspan Compression Joint

Midspan compression joint terdiri dari midspan compression joint konduktor dan midspan
compression joint GSW.

Tabel 4-7 Asesmen kondisi midspan compression joint melalui inspeksi Climb Up

Rekomendasi Tidak Lanjut


Jenis Index
No. Kondisi
Inspeksi Kondisi
Tindakan Jangka Waktu

1 Normal 9 - -

2 - 6 - -

Climb Up 3 Bengkok Penggantian

4 Meleleh 1 Penggantian Segera

5 Hampir Lepas Penggantian

4.2 Sub Sistem Insulation

Sub system insulation terdiri dari komponen Insulator (Ceramic dan Non-Ceramic) dan
ROW (Right Of Way).

24
PENGAWASAN DAN ASESMEN SUTT/SUTET

4.2.1 Insulator
Tabel 4-8 Asesmen kondisi Insulator (ceramic dan non-ceramic) melalui inspeksi Climb Up

Rekomendasi Tidak Lanjut


Jenis Index
No. Kondisi
Inspeksi Kondisi Jangka
Tindakan
Waktu

1 Normal 9 - -

Flash Over / Retak / Pecah


2 Penggantian
(<= 1/3 Jumlah Insulator)
Climb 6 6 Bulan
Up
3 Kotor Pembersihan

Flash Over / Retak / Pecah


4 1 Penggantian Segera
(> 1/3 Jumlah Insulator)

4.2.1.1 Ceramic Insulator


Tabel 4-9 Asesmen kondisi non ceramic insulator melalui inspeksi GP mingguan

Rekomendasi Tidak Lanjut


Jenis Index
No. Kondisi
Inspeksi Kondisi
Tindakan Jangka Waktu

1 Normal 9 - -
Ground
2 Pecah 6 Penggantian 6 Bulan
Patrol
Mingguan
Terdapat Benda
3 1 Pembersihan Segera
Asing

4.2.1.2 Non-Ceramic Insulator


Tabel 4-10 Asesmen kondisi ceramic insulator melalui inspeksi GP mingguan

Rekomendasi Tidak Lanjut


Jenis Index
No. Kondisi
Inspeksi Kondisi
Tindakan Jangka Waktu

1 Normal 9 - -

2 - 6 - 6 Bulan
Ground
Patrol
Terdapat Benda
Mingguan 3 Pembersihan
Asing
1 Segera
4 Patah Penggantian

25
PENGAWASAN DAN ASESMEN SUTT/SUTET

4.2.2 ROW (Right Of Way) atau Ruang Bebas

ROW atau Ruang Bebas adalah ruang sekeliling penghantar yang dibentuk oleh jarak
bebas minimum sepanjang SUTT atau SUTET yang didalam ruangan itu harus
dibebaskan dari benda - benda dan kegiatan lainnya. Sedangkan jarak bebas minimum
adalah jarak terpendek antara penghantar SUTT atau SUTET dengan permukaan tanah,
benda - benda dan kegiatan lain disekitarnya, yang mutlak tidak boleh lebih pendek dari
yang telah ditetapkan demi keselamatan manusia & makhluk hidup lainnya serta juga
keamanan operasi SUTT atau SUTET.

Jarak bebas minimum SUTT/SUTET diatur dalam Peraturan Menteri Pertambangan dan
Energi No.01.P/47/MPE/1992 tanggal 7 Februari 1992 dan Standar Nasional Indonesia
(SNI) no. 04-6918-2002 yang dapat dijelaskan pada tabel dibawah ini.

Tabel 4-11 Standar jarak bebas minimum ROW/ jarak aman (Peraturan Menteri
Pertambangan dan Energi No.01.P/47/MPE/1992 tanggal 7 Februari 1992 dan SNI 04-6918-
2002)

SUTT SUTT SUTET SUTET 500 kV

Sirkui
66 150 275
t Sirkuit
No Lokasi
Gand Tunggal
kV kV kV
a

(m) (m) (m) (m) (m)

Lapangan Terbuka atau Daerah


1 6,5 7,5 10,5 10 11
Terbuka

2 Daerah dengan keadaan tertentu:

2.1. Bangunan tidak tahan api 12,5 13,5 14 14 15

2.2. Bangunan tahan api 3,5 4,5 7 8,5 8,5

2.3. Lalu lintas jalan / jalan raya 8 9 11 15 15

Pohon-pohon pada umumnya,


2.4. 3,5 4,5 7 8,5 8,5
hutan dan perkebunan

2.5. Lapangan olahraga 12,5 13,5 15 14 15

SUTT lainnya, Saluran Udara


Tegangan Rendah (SUTR),
Saluran Udara Tegangan
2.6. 3 4 5 8,5 8,5
Menengah (SUTM), saluran udara
komunikasi, antena dan kereta
gantung

2.7. Rel kereta biasa 8 9 11 15 15

26
PENGAWASAN DAN ASESMEN SUTT/SUTET

SUTT SUTT SUTET SUTET 500 kV

Sirkui
66 150 275
t Sirkuit
No Lokasi
Gand Tunggal
kV kV kV
a

(m) (m) (m) (m) (m)

Jembatan besi, rangka besi


2.8. penahan penghantar, kereta listrik 3 4 7 8,5 8,5
terdekat dan sebagainya

Titik tertinggi tiang kapal pada


2.9. kedudukan air pasang tertinggi 3 4 6 8,5 8,5
pada lalu lintas air

Asesmen kondisi ROW (Right of Way) SUTT/SUTET dari hasil inspeksi Ground Patrol
dan Climb Up Inspection yaitu sebagai berikut:

Tabel 4-12 Asesmen kondisi ROW melalui inspeksi GP mingguan

Rekomendasi Tidak Lanjut


Jenis Index
No. Kondisi
Inspeksi Kondisi
Tindakan Jangka Waktu

1 Normal 9 - -

2 - 6 - -

Ada Aktifitas
3 Sosialisasi
Pekerjaan / Crane

Ground Ada Kegiatan


Patrol 4 Pembangunan / Sosialisasi
Mingguan Bangunan *
1 Segera
5 Tumbuhan * Pemangkasan

Benda Asing /
6 Sosialisasi
Aktifitas Manusia

7 Layang-layang Pembersihan

Keterangan: *) Mengacu pada Peraturan Menteri Pertambangan dan Energi


No.01.P/47/MPE/1992 dan SNI 04-6918-2002

27
PENGAWASAN DAN ASESMEN SUTT/SUTET

Tabel 4-13 Asesmen kondisi ROW melalui inspeksi Climb Up

Rekomendasi Tidak Lanjut


Jenis Index
No. Kondisi
Inspeksi Kondisi
Tindakan Jangka Waktu

1 Normal 9 - -

2 - 6 - -
Climb Up
Pengukuran
Obyek dengan
3 1 Perbaikan Segera
jarak < standar
jarak aman *

Keterangan: *) Mengacu pada Peraturan Menteri Pertambangan dan Energi


No.01.P/47/MPE/1992 dan SNI 04-6918-2002

Untuk menghitung jarak bebas/ jarak ROW dibagi menjadi 2 jenis yaitu jarak bebas
minimum dengan permukaan tanah, benda - benda dan kegiatan lain disekitarnya yang
berada di bawah konduktor SUTT/ SUTET dan jarak bebas minimum dengan benda -
benda disekitarnya yang berada di samping konduktor SUTT/ SUTET. Cara menghitung
jarak bebas/ jarak ROW dapat dijelaskan pada gambar dibawah ini.

28
PENGAWASAN DAN ASESMEN SUTT/SUTET

- Perhitungan Jarak ROW Konduktor SUTT/SUTET dengan pohon dibawah jalur


(C):

Gambar 4-2 Perhitungan Jarak ROW Konduktor SUTT/SUTET dengan pohon dibawah jalur
(C)

29
PENGAWASAN DAN ASESMEN SUTT/SUTET

- Perhitungan Jarak ROW Konduktor SUTT/SUTET dengan pohon disamping


jalur (C’):

Gambar 4-3 Perhitungan Jarak ROW Konduktor SUTT/SUTET dengan pohon disamping jalur
(C’)

30
PENGAWASAN DAN ASESMEN SUTT/SUTET

- Perhitungan Jarak ROW Konduktor SUTT/SUTET dengan bangunan dibawah


jalur (C):

Gambar 4-4 Perhitungan Jarak ROW Konduktor SUTT/SUTET dengan bangunan


dibawah jalur (C)

31
PENGAWASAN DAN ASESMEN SUTT/SUTET

- Perhitungan Jarak ROW Konduktor SUTT/SUTET dengan antena di luar jalur,


antena lebih tinggi dari konduktor SUTT/SUTET (C’):

Gambar 4-5 Perhitungan Jarak ROW Konduktor SUTT/SUTET dengan antena di luar jalur,
antena lebih tinggi dari konduktor SUTT/SUTET (C’)

32
PENGAWASAN DAN ASESMEN SUTT/SUTET

4.3 Structure

Structure terdiri dari komponen member/ besi siku/ bracing, cat/ galvanis tiang, chimney/
kepala pondasi, halaman tower, mur dan baut tower, plat sambungan rangka dan stub.

4.3.1 Member/ Besi Siku/ Bracing


Tabel 4-14 Asesmen kondisi member/ besi siku/ bracing melalui inspeksi Climb Up

Rekomendasi Tindak Lanjut


Jenis Index
No Kondisi
Inspeksi Kondisi
Tindakan Jangka Waktu

1 Normal 9 - -

Ketebalan
2 6 Pengamatan 3 Bulan
Climb Up Galvanis 40-70 %

Ketebalan
3 1 Pengecatan Segera
Galvanis <40%

Tabel 4-15 Asesmen kondisi member/ besi siku/ bracing melalui inspeksi GP mingguan

Rekomendasi Tindak Lanjut


Jenis Index
No Kondisi
Inspeksi Kondisi
Tindakan Jangka Waktu

1 Normal 9 - -

2 Bengkok Penggantian 6 Bulan


Ground 6
Patrol 3 Kendor Pengencangan 6 Bulan
Mingguan
4 Hilang Penggantian Segera
1
5 Patah Penggantian Segera

Tabel 4-16 Asesmen kondisi member/ besi siku/ bracing melalui inspeksi GP triwulanan

Rekomendasi Tindak Lanjut


Jenis Index
No Kondisi
Inspeksi Kondisi
Tindakan Jangka Waktu

Ground 1 Normal 9 - -
Patrol
Triwulanan 2 Korosi 6 Pengamatan 3 Bulan

33
PENGAWASAN DAN ASESMEN SUTT/SUTET

4.3.2 Cat/ Galvanis Tiang


Tabel 4-17 Asesmen kondisi cat/ galvanis tiang melalui inspeksi Climb Up

Rekomendasi Tindak Lanjut


Jenis Index
No Kondisi
Inspeksi Kondisi
Tindakan Jangka Waktu

1 Normal 9 - -

Ketebalan
2 6 Pengamatan 3 Bulan
Climb Up Galvanis 40 - 70 %

Ketebalan
3 1 Pengecatan Segera
Galvanis < 40%

Tabel 4-18 Asesmen kondisi cat/ galvanis tiang melalui inspeksi GP triwulanan

Rekomendasi Tindak Lanjut


Jenis Index
No Kondisi
Inspeksi Kondisi
Tindakan Jangka Waktu

1 Normal 9 - -

Ground Level Korosi 40 -


3 6 Pengamatan 3 Bulan
Patrol 80 %
Triwulanan
Level Korosi >
5 1 Pengecatan Segera
80 %

4.3.3 Chimney/ Kepala Pondasi


Tabel 4-19 Asesmen kondisi chimney/ kepala pondasi melalui inspeksi GP mingguan

Rekomendasi Tindak Lanjut


Index
Jenis Inspeksi No Kondisi
Kondisi
Tindakan Jangka Waktu

1 Normal 9 - -

2 Tertimbun 6 Perbaikan 6 Bulan


Ground Patrol
3 Retak 6 Perbaikan 6 Bulan
Mingguan
4 Terendam 1 Perbaikan Segera

5 Bergeser 1 Perbaikan Segera

34
PENGAWASAN DAN ASESMEN SUTT/SUTET

4.3.4 Halaman Tower


Tabel 4-20 Asesmen kondisi halaman tower melalui inspeksi GP minguan

Rekomendasi Tindak Lanjut


Jenis Index
No Kondisi
Inspeksi Kondisi
Tindakan Jangka Waktu

1 Normal 9 - -

2 Banjir 6 Pengecatan 6 Bulan


Ground
Patrol
3 Longsor 1 Perbaikan Segera
Mingguan
Dimanfaatkan
4 1 Sosialisasi Segera
pihak lain

4.3.5 Mur dan Baut Tower


Tabel 4-21 Asesmen kondisi mur dan baut tower melalui inspeksi Climb Up

Rekomendasi Tindak Lanjut


Jenis Index
No Kondisi
Inspeksi Kondisi
Tindakan Jangka Waktu

1 Normal 9 - -

2 Kendor Pengencangan 6 Bulan


6
Level Korosi
3 Pengamatan 3 Bulan
Climb Up 40-60 %

Level Korosi
4 Penggantian Segera
>60 %
1
5 Hilang Penggantian Segera

Tabel 4-22 Asesmen kondisi mur dan baut tower melalui inspeksi GP triwulanan

Rekomendasi Tindak Lanjut


Jenis Index
No Kondisi
Inspeksi Kondisi
Tindakan Jangka Waktu

1 Normal 9 - -
Ground
Patrol 2 Korosi 6 Pengamatan 3 Bulan
Triwulanan
3 Hilang 1 Penggantian Segera

35
PENGAWASAN DAN ASESMEN SUTT/SUTET

4.3.6 Plat Sambungan Rangka


Tabel 4-23 Asesmen plat sambungan rangka melalui inspeksi Climb Up

Rekomendasi Tindak Lanjut


Jenis Index
No Kondisi
Inspeksi Kondisi
Tindakan Jangka Waktu

1 Normal 9 - -

Ketebalan
2 Galvanis 40 6 Pengamatan 3 Bulan
Climb Up - 70 %

Ketebalan
3 Galvanis 1 Pengecatan Segera
<40%

Tabel 4-24 Asesmen plat sambungan rangka melalui inspeksi GP mingguan

Rekomendasi Tindak Lanjut


Jenis Index
No Kondisi
Inspeksi Kondisi
Tindakan Jangka Waktu

1 Normal 9 - -
Ground
Patrol 2 Hilang 1 Penggantian Segera
Mingguan
3 Rusak 1 Perbaikan Segera

4.3.7 Stub
Tabel 4-25 Asesmen kondisi stub melalui inspeksi GP mingguan

Rekomendasi Tindak Lanjut


Jenis Index
No Kondisi
Inspeksi Kondisi
Tindakan Jangka Waktu

1 Normal 9 - -

2 Tertimbun 6 Perbaikan 6 Bulan


Ground
Patrol 3 Korosi 6 Pengamatan 3 Bulan
Mingguan
4 Bengkok 1 Perbaikan Segera

5 Terendam 1 Perbaikan Segera

36
PENGAWASAN DAN ASESMEN SUTT/SUTET

4.4 Sub Sistem Junction

Sub sistem junction terdiri dari komponen Box Joint OPGW, Midspan Compression Joint,
Fitting Insulator, Suspension/ Tension Clamp, Ikatan Insulator dan Sealing End Kabel
(Tower Transisi SUTT-SKTT).

4.4.1 Box Joint OPGW


Tabel 4-26 Asesmen kondisi box joint OPGW melalui inspeksi Climb Up

Rekomendasi Tidak Lanjut


Jenis Index
No. Kondisi
Inspeksi Kondisi
Tindakan Jangka Waktu

1 Normal * 9 - -

Climb Up 2 Pecah 6 Penggantian 6 Bulan

3 Hilang 1 Penggantian Segera

Keterangan: *) Normal terpasang atau normal tidak terpasang

4.4.2 Fitting Insulator

Fitting Insulator adalah semua komponen selain insulator yang menjadi penghubung
antara konduktor dengan tower. Fitting insulator dapat berupa Suspension/ Tension
Clamp, Clevis, Plate, Link, Shackle, Turn Buckle, Socket.

4.4.2.1 Suspension/ Tension Clamp

Suspension/ Tension Clamp adalah komponen yang digunakan untuk menghubungkan


konduktor dengan insulator. Tension Clamp dapat berupa Dead end compression dan
strain clamp.

Tabel 4-27 Asesmen kondisi suspension/ tension clamp melalui inspeksi Climb Up

Rekomendasi Tidak Lanjut


Jenis Index
No. Kondisi
Inspeksi Kondisi
Tindakan Jangka Waktu

1 Normal 9 - -

Level Korosi
2 Pengamatan 3 bulanan
(40% - 60%)
Climb Up 6
Baut Tidak
3 Perbaikan 6 bulan
Lengkap

4 Level Korosi 1 Penggantian Segera

37
PENGAWASAN DAN ASESMEN SUTT/SUTET

Rekomendasi Tidak Lanjut


Jenis Index
No. Kondisi
Inspeksi Kondisi
Tindakan Jangka Waktu
(> 60%)

5 Retak Penggantian

6 Pecah Penggantian

4.4.2.2 Clevis, Plate, Link, Shackle, Turn Buckle, Socket

Komponen Clevis, Plate, Link, Shackle, Turn Buckle, Socket dapat berupa Socket Clavis,
Bolt Clevis, Triangle Plate, Triangle Plate Link, Square Plate, Shackle, Turn Buckle, Link
Adjuster, Link Bold Socket, Extension Link.

Tabel 4-28 Asesmen kondisi Clevis, Plate, Link, Shackle, Turn Buckle, Socket melalui
inspeksi Climb Up

Rekomendasi Tidak Lanjut


Jenis Index
No. Kondisi
Inspeksi Kondisi
Tindakan Jangka Waktu

1 Normal 9 - -

Level Korosi
2 Pengamatan 3 Bulan
(40% - 60%)
6
Climb Up
Pin Tidak
3 Perbaikan 6 Bulan
Lengkap

Level Korosi
4 1 Penggantian Segera
(> 60%)

4.4.3 Ikatan Insulator

Ikatan Insulator yaitu komponen yang menghubungkan antar piringan insulator. Ikatan
insulator dapat berupa ball dan pin insulator.
Tabel 4-29 Asesmen kondisi ikatan insulator melalui inspeksi Climb Up

Rekomendasi Tidak Lanjut


Jenis Index
No. Kondisi
Inspeksi Kondisi
Tindakan Jangka Waktu

1 Normal 9 - -
Climb Up
Level Korosi
2 6 Pengamatan 3 bulanan
(40% - 60%)

38
PENGAWASAN DAN ASESMEN SUTT/SUTET

Rekomendasi Tidak Lanjut


Jenis Index
No. Kondisi
Inspeksi Kondisi
Tindakan Jangka Waktu

Level Korosi
3 Penggantian
(> 60%)
1 Segera
Ball & Pin tidak
4 Perbaikan
terhubung sempurna

4.4.4 Sealing End Kabel (Tower Transisi SUTT - SKTT)

Tabel 4-30 Asesmen kondisi Sealing End Kabel (Tower Transisi SUTT-SKTT) melalui
inspeksi GP mingguan

Rekomendasi Tidak Lanjut


Jenis Index
No. Kondisi
Inspeksi Kondisi
Tindakan Jangka Waktu

1 Normal - -
9
Bukan Tower
Ground 2 - -
Transisi
Patrol
Mingguan
3 Rembes 6 Perbaikan 6 bulan

4 Bocor 1 Perbaikan Segera

4.5 Sub Sistem Protection

Sub sistem protection terdiri dari 5 jenis komponen yaitu:

- Pengaman dari gangguan petir (Kawat Tanah / GSW / OPGW, arching horn,
jumper GSW, konduktor penghubung kawat tanah, kawat tanah).
- Pengaman dari getaran / stres mekanis yang ditimbulkan oleh angin (spacer,
armour rod, vibration damper).
- Pengaman dari ancaman / kemungkinan gangguan akibat manusia (ACD /
Anti Climbing Device, plat rambu bahaya).
- Pengaman dari kemungkinan gangguan luar (bola rambu, aviation lamp,
lampu indikator tower).
- Pengaman dari urat konduktor putus (repair sleeve, armour rod span).

39
PENGAWASAN DAN ASESMEN SUTT/SUTET

4.5.1 Kawat Tanah/ GSW/ OPGW


Tabel 4-31 Asesmen kondisi kawat tanah/ GSW/ OPGW melalui inspeksi Climb Up

Rekomendasi Tindak Lanjut


Jenis Index
No Kondisi
Inspeksi Kondisi
Tindakan Jangka Waktu

1 Normal 9 - -

Level Korosi
2 6 Pengamatan 3 Bulan
40-60 %
Climb Up
Level Korosi
3 Penggantian Segera
> 60 %
1
4 Rantas Perbaikan Segera

Tabel 4-32 Asesmen kondisi kawat tanah/ GSW/ OPGW melalui inspeksi GP mingguan

Rekomendasi Tindak Lanjut


Jenis Index
No Kondisi
Inspeksi Kondisi
Tindakan Jangka Waktu

1 Normal 9 - -

Benda
Ground 2 6 Pembersihan 6 Bulan
Asing
Patrol
Mingguan
3 Rantas Perbaikan Segera
1
4 Melorot Perbaikan Segera

4.5.2 Arching Horn


Tabel 4-33 Asesmen kondisi arcing horn melalui inspeksi GP triwulanan

Rekomendasi Tindak Lanjut


Jenis Index
No Kondisi
Inspeksi Kondisi
Tindakan Jangka Waktu

1 Normal * 9 - -

Terpasang
Ground 2 tidak saling 6 Pebaikan 6 Bulan
Patrol berhadapan
Triwulanan
3 Jatuh Perbaikan Segera
1
4 Hilang Penggantian Segera

40
PENGAWASAN DAN ASESMEN SUTT/SUTET

Tabel 4-34 Asesmen kondisi arcing horn melalui inspeksi Climb Up

Rekomendasi Tindak Lanjut


Jenis Index
No Kondisi
Inspeksi Kondisi
Tindakan Jangka Waktu

1 Normal * 9 - -

Level Korosi
2 6 Pengawasan 3 Bulan
40-60 %
Climb Up
Level Korosi
3 Penggantian Segera
> 60 %
1
Salah
4 Perbaikan Segera
Pemasangan

Keterangan: *) Normal terpasang atau normal tidak terpasang

4.5.3 Jumper GSW


Tabel 4-35 Asesmen kondisi jumper GSW melalui inspeksi GP mingguan

Rekomendasi Tindak Lanjut


Jenis Index
No Kondisi
Inspeksi Kondisi
Tindakan Jangka Waktu

Ground 1 Normal 9 - -
Patrol
Mingguan 2 Putus 1 Penggantian Segera

4.5.4 Konduktor Penghubung Kawat Tanah


Tabel 4-36 Asesmen kondisi konduktor penghubung kawat tanah melalui inspeksi Climb Up

Rekomendasi Tindak Lanjut


Jenis Index
No Kondisi
Inspeksi Kondisi
Tindakan Jangka Waktu

1 Normal 9 - -

Level Korosi
2 6 Pengamatan 3 Bulan
40 - 60 %

Climb Up Level Korosi


3 Penggantian Segera
> 60 %
1
4 Rantas Perbaikan Segera

5 Putus Penggantian Segera

41
PENGAWASAN DAN ASESMEN SUTT/SUTET

4.5.5 Kawat Grounding


Tabel 4-37 Asesmen kondisi kawat grounding melalui inspeksi Climb Up

Rekomendasi Tindak Lanjut


Jenis Index
No Kondisi
Inspeksi Kondisi
Tindakan Jangka Waktu

1 Normal * 9 - -

Level Korosi
2 6 Pengamatan 3 Bulan
40 - 60 %

Climb Up Level Korosi


3 Penggantian Segera
> 60 %
1
4 Hilang Perbaikan Segera

5 Putus Perbaikan Segera

Keterangan: *) Normal terpasang atau normal solid grounding (tidak terlihat)

Tabel 4-38 Asesmen kondisi kawat grounding melalui inspeksi GP mingguan

Rekomendasi Tindak Lanjut


Jenis Index
No Kondisi
Inspeksi Kondisi
Tindakan Jangka Waktu

1 Normal * 9 - -

2 Rantas Perbaikan 6 Bulan

Ground 3 Korosi 6 Pengamatan 3 Bulan


Patrol
Mingguan 4 Kendor Perbaikan 6 Bulan

5 Hilang Penggantian Segera


1
6 Putus Perbaikan Segera

Keterangan: *) Normal terpasang atau normal solid grounding (tidak terlihat)

42
PENGAWASAN DAN ASESMEN SUTT/SUTET

4.5.6 Spacer
Tabel 4-39 Asesmen kondisi spacer melalui inspeksi Climb Up

Rekomendasi Tindak Lanjut


Jenis Index
No Kondisi
Inspeksi Kondisi
Tindakan Jangka Waktu

1 Normal * 9 - -

2 Bergeser 6 Perbaikan 6 Bulan


Climb Up
3 Lepas Penggantian Segera
1
4 Patah Penggantian Segera

Keterangan: *) Normal terpasang atau normal tidak terpasang

Tabel 4-40 Asesmen kondisi spacer melalui inspeksi GP mingguan

Rekomendasi Tindak Lanjut


Jenis Index
No Kondisi
Inspeksi Kondisi
Tindakan Jangka Waktu

1 Normal * 9 - -

Ground 2 Lepas Penggantian Segera


Patrol
Mingguan 3 Jatuh 1 Penggantian Segera

4 Hilang Penggantian Segera

Keterangan: *) Normal terpasang atau normal tidak terpasang

4.5.7 Armour Rod


Tabel 4-41 Asesmen kondisi armour rod melalui inspeksi Climb Up

Rekomendasi Tindak Lanjut


Jenis Index
No Kondisi
Inspeksi Kondisi
Tindakan Jangka Waktu

1 Normal * 9 - -
Climb Up
2 Mekar 1 Perbaikan Segera

Keterangan: *) Normal terpasang atau normal tidak terpasang

43
PENGAWASAN DAN ASESMEN SUTT/SUTET

4.5.8 Vibration Damper, Counter Weight


Tabel 4-42 Asesmen kondisi vibration damper melalui inspeksi GP triwulanan

Rekomendasi Tindak Lanjut


Jenis Index
No Kondisi
Inspeksi Kondisi
Tindakan Jangka Waktu

1 Normal 9 - -

2 Melorot Perbaikan 6 Bulan

Tidak
Ground 6
Terpasang
Patrol 3 Perbaikan 6 Bulan
dengan
Triwulanan
benar

4 Jatuh Perbaikan Segera


1
5 Hilang Penggantian Segera

Tabel 4-43 Asesmen kondisi vibration damper dan counter weight melalui inspeksi Climb Up

Rekomendasi Tindak Lanjut


Jenis Index
No Kondisi
Inspeksi Kondisi
Tindakan Jangka Waktu

1 Normal 9 - -

2 Bergeser Perbaikan 6 Bulan


6
Level Korosi
3 Pengamatan 3 Bulan
40 - 60 %
Climb Up
Level Korosi
4 Penggantian Segera
> 60 %
1
5 Lepas Perbaikan Segera

6 Retak Perbaikan Segera

4.5.9 Anti Climbing Device


Tabel 4-44 Asesmen kondisi Anti Climbing Device melalui inspeksi GP mingguan

Rekomendasi Tindak Lanjut


Index
Jenis Inspeksi No Kondisi
Kondisi
Tindakan Jangka Waktu

Ground Patrol 1 Normal 9 - -

44
PENGAWASAN DAN ASESMEN SUTT/SUTET

Rekomendasi Tindak Lanjut


Index
Jenis Inspeksi No Kondisi
Kondisi
Tindakan Jangka Waktu
Mingguan
2 Patah Perbaikan 6 Bulan
6
3 Korosi Perbaikan 6 Bulan

4 Hilang 1 Penggantian Segera

4.5.10 Plat Rambu Bahaya


Tabel 4-45 Asesmen kondisi plat rambu bahaya melalui inspeksi GP mingguan

Rekomendasi Tindak Lanjut


Jenis Index
No Kondisi
Inspeksi Kondisi
Tindakan Jangka Waktu

1 Normal 9 - -

Hilang /
2 Rusak / Penggantian Segera
Ground
Korosi
Patrol
Mingguan 1
3 Cat Pudar Perbaikan Segera

Informasi
4 Penggantian Segera
Salah

4.5.11 Bola Rambu


Tabel 4-46 Asesmen kondisi bola rambu melalui inspeksi GP triwulanan

Rekomendasi Tindak Lanjut


Jenis Index
No Kondisi
Inspeksi Kondisi
Tindakan Jangka Waktu

1 Normal * 9 - -

2 Melorot 6 Perbaikan 6 Bulan


Ground
Patrol
3 Pecah Penggantian Segera
Triwulanan
1
Terjatuh /
4 Penggantian Segera
Hilang

Keterangan: *) Normal terpasang atau normal tidak terpasang

45
PENGAWASAN DAN ASESMEN SUTT/SUTET

Tabel 4-47 Asesmen kondisi bola rambu melalui inspeksi Climb Up

Rekomendasi Tindak Lanjut


Jenis Index
No Kondisi
Inspeksi Kondisi
Tindakan Jangka Waktu

1 Normal * 9 - -

2 Bergeser 6 Perbaikan 6 Bulan


Climb Up
4 Pecah Penggantian Segera
1
5 Hilang Penggantian Segera

Keterangan: *) Normal terpasang atau normal tidak terpasang

4.5.12 Aviation Lamp/ Lampu Aviasi


Tabel 4-48 Asesmen kondisi aviation lamp melalui inspeksi GP triwulanan

Rekomendasi Tindak Lanjut


Jenis Index
No Kondisi
Inspeksi Kondisi
Tindakan Jangka Waktu

1 Normal * 9 - -

2 Bergeser Perbaikan 6 Bulan


Ground 6
Patrol 3 Melorot Perbaikan 6 Bulan
Triwulanan
4 Terjatuh Penggantian Segera
1
5 Padam Penggantian Segera

Keterangan: *) Normal terpasang atau normal tidak terpasang

Tabel 4-49 Asesmen kondisi aviation lamp melalui inspeksi Climb Up

Rekomendasi Tindak Lanjut


Jenis Index
No Kondisi
Inspeksi Kondisi
Tindakan Jangka Waktu

1 Normal * 9 - -
Climb Up
Rusak /
2 1 Penggantian Segera
Pecah

Keterangan: *) Normal terpasang atau normal tidak terpasang

46
PENGAWASAN DAN ASESMEN SUTT/SUTET

4.5.13 Lampu Indikator Tower


Tabel 4-50 Asesmen kondisi lampu indikator tower melalui inspeksi Ground Patrol Triwulan

Rekomendasi Tindak Lanjut


Jenis Index
No Kondisi
Inspeksi Kondisi
Tindakan Jangka Waktu

1 Normal * 9 - -
Ground
Patrol Penggantian /
Triwulanan 2 Hilang / Rusak 1 Segera
Perbaikan

Keterangan: *) Normal terpasang atau normal tidak terpasang

4.5.14 Repair Sleeve


Tabel 4-51 Asesmen kondisi repair sleeve melalui inspeksi Climb Up

Rekomendasi Tindak Lanjut


Jenis Index
No Kondisi
Inspeksi Kondisi
Tindakan Jangka Waktu

1 Normal * 9 - -

2 Bengkok Penggantian Segera


Climb Up
3 Hampir Lepas 1 Penggantian Segera

4 Meleleh Penggantian Segera

Keterangan: *) Normal terpasang atau normal tidak terpasang

4.5.15 Armour Rod Span


Tabel 4-52 Asesmen kondisi armour rod span melalui inspeksi Climb Up

Rekomendasi Tindak Lanjut


Jenis Index
No Kondisi
Inspeksi Kondisi
Tindakan Jangka Waktu

1 Normal * 9 - -
Climb Up
2 Mekar 1 Perbaikan Segera

Keterangan: *) Normal terpasang atau normal tidak terpasang

47
PENGAWASAN DAN ASESMEN SUTT/SUTET

4.5.16 TLA (Transmission Line Arrester)


Tabel 4-53 Asesmen kondisi TLA melalui inspeksi Climb Up

Rekomendasi Tindak Lanjut


Jenis Index
No Kondisi
Inspeksi Kondisi
Tindakan Jangka Waktu

1 Normal * 9 - -

Counter menunjukkan Pemantauan


2 6 6 bulan
warna kuning rutin

Kabel grounding TLA Perbaikan /


Climb 3 Segera
lepas / putus penggantian
Up
Counter menunjukkan
4 1 Penggantian Segera
warna merah

Insulator TLA flash / Perbaikan /


5 Segera
pecah / rusak, kotor penggantian

Keterangan: *) Normal terpasang atau normal tidak terpasang

Tabel 4-54 Asesmen kondisi TLA melalui inspeksi GP mingguan

Rekomendasi Tindak Lanjut


Jenis Index
No Kondisi
Inspeksi Kondisi
Tindakan Jangka Waktu

1 Normal * 9 - -
Ground
Patrol
Kabel grounding TLA Perbaikan /
Mingguan 2 1 Segera
lepas / putus penggantian

Keterangan: *) Normal terpasang atau normal tidak terpasang

48
PENGAWASAN DAN ASESMEN SUTT/SUTET

4.5.17 Jejaring Pengaman (Vangnet)


Tabel 4-55 Asesmen kondisi jejaring pengaman (vangnet) melalui inspeksi GP mingguan

Rekomendasi Tindak Lanjut


Jenis Index
No Kondisi
Inspeksi Kondisi
Tindakan Jangka Waktu

1 Normal * 9 - -

Ground 2 Korosi 6 Perbaikan 6 Bulan


Patrol
Mingguan 3 Lepas
Perbaikan /
1 Segera
penggantian
4 Hilang

Keterangan: *) Normal terpasang atau normal tidak terpasang

4.6 Sub Sistem Monitoring

Sub sistem monitoring terdiri dari komponen plat informasi tower, baut panjat dan patok
batas.

4.6.1 Plat Informasi Tower


Tabel 4-56 Asesmen kondisi plat informasi tower melalui inspeksi GP mingguan

Rekomendasi Tindak Lanjut


Jenis Index
No Kondisi
Inspeksi Kondisi
Tindakan Jangka Waktu

1 Normal 9 - -

Hilang/
2 Rusak/ Penggantian Segera
Ground
Korosi
Patrol
Mingguan 1
3 Cat Pudar Perbaikan Segera

Informasi
4 Penggantian Segera
Salah

49
PENGAWASAN DAN ASESMEN SUTT/SUTET

4.6.2 Baut Panjat


Tabel 4-57 Asesmen kondisi baut panjat melalui inspeksi Climb Up

Rekomendasi Tindak Lanjut


Jenis Index
No Kondisi
Inspeksi Kondisi
Tindakan Jangka Waktu

1 Normal 9 - -

2 Bengkok Penggantian 9 Bulan


6
Level Korosi
3 Penggantian 6 Bulan
Climb Up 40 - 60 %

Level Korosi
4 Penggantian Segera
> 60 %
1
5 Hilang Penggantian Segera

Tabel 4-58 Asesmen kondisi baut panjat melalui inspeksi GP mingguan

Rekomendasi Tindak Lanjut


Jenis Index
No Kondisi
Inspeksi Kondisi
Tindakan Jangka Waktu

1 Normal 9 - -

Ground 2 Korosi Penggantian 6 Bulan


Patrol 6
Mingguan 3 Bengkok Penggantian 6 Bulan

4 Hilang 1 Penggantian Segera

4.6.3 Patok Batas


Tabel 4-59 Asesmen kondisi patok batas melalui inspeksi GP triwulanan

Rekomendasi Tindak Lanjut


Jenis Index
No Kondisi
Inspeksi Kondisi
Tindakan Jangka Waktu

1 Normal 9 - -

2 Tertimbun Pembersihan 6 Bulan


Ground 6
Patrol 3 Pecah Perbaikan 6 Bulan
Triwulanan
4 Hilang Penggantian Segera
1
5 Bergeser Perbaikan Segera

50
PENGAWASAN DAN ASESMEN SUTT/SUTET

Untuk mempermudah asesmen kondisi komponen SUTT/ SUTET dan pemetaan kondisi
abnormal komponen SUTT/ SUTET, PT PLN merekomendasikan Aplikasi CBM
(Condition Based Maintenance) yang saat ini telah digunakan di PT PLN P3B Jawa Bali.
Aplikasi CBM adalah aplikasi berbasis database yang berfungsi untuk memonitor kondisi
asset transmisi. Hasil inspeksi dan pemeliharaan diinput ke dalam aplikasi ini, kemudian
output dari aplikasi CBM adalah justifikasi kondisi komponen SUTT/ SUTET lengkap
dengan rekap data dan grafiknya serta justifikasi kondisi tower secara keseluruhan. Selain
itu terdapat menu rekomendasi tindak lanjut yang dapat digunakan sebagai rencana
tindak lanjut kondisi abnormal yang akan dilaksanakan tim pemeliharaan. Berikut ini
adalah contoh tampilan aplikasi CBM.

Gambar 4-6 Tampilan login aplikasi CBM

Gambar 4-7 Tampilan database di aplikasi CBM

51
PENGAWASAN DAN ASESMEN SUTT/SUTET

Gambar 4-8 Contoh tampilan checklist dalam aplikasi CBM

52
PENGAWASAN DAN ASESMEN SUTT/SUTET

Lampiran 1 TABEL PERIODE PENGAWASAN DAN ASESMEN SUTT/SUTET

/E6= CF)CBC;=2 B;=21 =/=N8DD- /!,!#'(3'(

@'#$'(
P1;'45(
Q1;'45(
R1;'45(

)5.'('(
O1)5.'('(

2$(335'(
/*(<$&$*('.
B(&7!%&$1:#*5(<1 ',#*.
8)4)"%#:!!+$#'4;'+)+ ]%+%4!?$:!&9$4%+,,9 !&!9$:):9!%
P):9!%$PQ$VUM$007
&'()"$:)R!"!$A%:9!? #'+*%:%$?%+,#9+,!+$*!+$#)"!(!+!+
?.$"+1571$(&7!S,$*(
8)4)"%#:!!+$#'4;'+)+ ]%+%4!?$?%4!$&!<9+$!&!9$:):9!%
P):9!%$PQ$VUM$007
&'()"$:)R!"!$A%:9!? #'+*%:%$?%+,#9+,!+$*!+$#)"!(!+!+
D&!&"!(1D(S'"'(
QO0P0P
A$(3%5(3'(
Q'+*%:%'+!?$!;!-%?!$4)+*!;!&
6=G0G0G0 8':%:%$P9+,!%
%+;9&!+$*!"%$8L8
8)4)"%#:!!+$I!"!#$#!#%$&'()" Q'+*%:%'+!?$!;!-%?!$4)+*!;!&
6=G0G0G6G0
*)+,!+$-%-%"$:9+,!% %+;9&!+$*!"%$8L8
Q'+*%:%'+!?$!;!-%?!$4)+*!;!&
6=G0G0G6G6 @?%"!+$P9+,!% 8)4)"%#:!!+$?)-!"$:9+,!%
%+;9&!+$*!"%$8L8
8)4)"%#:!!+$#)R);!&!+$!"9: Q'+*%:%'+!?$!;!-%?!$4)+*!;!&
6=G0G0G6G=
:9+,!% %+;9&!+$*!"%$8L8
Q'+*%:%'+!?$!;!-%?!$4)+*!;!&
6=G0G0G= L!+,,9!+$X#:&)"+!?
%+;9&!+$*!"%$8L8
Q'+*%:%'+!?$!;!-%?!$4)+*!;!&
6=G0G0G7 )I!#$L!+,,9!+
%+;9&!+$*!"%$8L8
Q'+*%:%'+!?$!;!-%?!$4)+*!;!&
6=G0G0G5 c),)&!:%$8)+9&9;
%+;9&!+$*!"%$8L8

53
PENGAWASAN DAN ASESMEN SUTT/SUTET

/E6= CF)CBC;=2 B;=21 =/=N8DD- /!,!#'(3'(

@'#$'(
P1;'45(
Q1;'45(
R1;'45(

)5.'('(
O1)5.'('(

2$(335'(
/*(<$&$*('.
8)4)"%#:!!+$#)&%+,,%!+ Q'+*%:%'+!?$!;!-%?!$4)+*!;!&
6=G0G0GEG0
&)-%+, %+;9&!+$*!"%$8L8
8)4)"%#:!!+$P9*9& Q'+*%:%'+!?$!;!-%?!$4)+*!;!&
6=G0G0GEG6 Z)")+,$d$H)-%+,
Q)4%"%+,!+ %+;9&!+$*!"%$8L8
8)4)"%#:!!+$I!"!#$#!#%$&'()" Q'+*%:%'+!?$!;!-%?!$4)+*!;!&
6=G0G0GEG=
*)+,!+$&)-%+, %+;9&!+$*!"%$8L8
Q'+*%:%'+!?$!;!-%?!$4)+*!;!&
6=G0G0GJ H!+!<$d$>!&9!+
%+;9&!+$*!"%$8L8
D&!&"!(1'(S'"'(1%*(<$&$
QO0P0Q
7*(<'&$
D&!&"!(1'(S'"'(1%*(<$&$
QO0P0Q0P
7*(<'&$1.',,$S!
Q'+*%:%'+!?$!;!-%?!$4)+*!;!&
6=G0G6G0G0 P&9-
%+;9&!+$*!"%$8L8
Q'+*%:%'+!?$!;!-%?!$4)+*!;!&
6=G0G6G0G6 S<%4+)`
%+;9&!+$*!"%$8L8
Q'+*%:%'+!?$!;!-%?! 4)+*!;!&
6=G0G6G0G= >!?'#$#';)?\1
%+;9&!+$*!"%$8L8
D&!&"!(1'(S''(1%*(<$&$
QO0P0Q0Q
7*(<'&$17*.!
Q'+*%:%'+!?$!;!-%?!$4)+*!;!&
6=G0G6G6G0 @+,#9"
%+;9&!+$*!"%$8L8
Q'+*%:%'+!?$!;!-%?!$4)+*!;!&
6=G0G6G6G6 S<%4+)`
%+;9&!+$*!"% 8L8

54
PENGAWASAN DAN ASESMEN SUTT/SUTET

/E6= CF)CBC;=2 B;=21 =/=N8DD- /!,!#'(3'(

@'#$'(
P1;'45(
Q1;'45(
R1;'45(

)5.'('(
O1)5.'('(

2$(335'(
/*(<$&$*('.
!(3'L'&'(1%*(<$&$
QO0P0O
'(S'"'(
8)4)"%#:!!+$;)"9-!<!+
6=G0G=G0 :R'")$!+R!4!+$?%+,#9+,!+B P):9!%$:R'")$!+R!4!+$&'()"
;'+*!:%

55
PENGAWASAN DAN ASESMEN SUTT/SUTET

Lampiran 2 Gambar Contoh Tower Transmisi

a. Tower 500 kV Sirkuit Tunggal

,!//!) !"#
-.2+)3
0!1
0!1
-.2+)3

!''!/ !''!/

,-!**.-/ ,-!**.-/ ,-!**.-/

4+.3!).5

!"#$%&'()*+!)
,!//!)$ !"#

4+.6-.37/.

4+.6-.37/.

!"#

56
PENGAWASAN DAN ASESMEN SUTT/SUTET

b. Tower 500 kV Sirkuit Ganda


,-!**.-/

0!1
-.2+)3

!''!/

,-!**.-/

0!1
4+.6-.37/.
-.2+)3
4+.3!).5 !''!/

!"#$%&'()*+!) ,!//!)
!"#

,-!**.-/

0!1

-.2+)3
!''!/

,-!**.-/

0!1

-.2+)3
!''!/

!"#

4+.6-.37/.

:8 8988

:;

:<

:=

:>?

:>@

57
PENGAWASAN DAN ASESMEN SUTT/SUTET

c. Tower Steelpole 150 kV Sirkuit Ganda

58
PENGAWASAN DAN ASESMEN SUTT/SUTET

d. Tower Lattice 150 kV Sirkuit Ganda

59
PENGAWASAN DAN ASESMEN SUTT/SUTET

Lampiran 3 Foto Komponen SUTT/SUTET

Tower tipe Lattice Tower tipe Steel Pole

Chimney dan Stub Tower Lattice Pondasi Tower Steel Pole

60
PENGAWASAN DAN ASESMEN SUTT/SUTET

I. Sub Sistem Current Carrying

1. Konduktor

Contoh Konduktor rantas : Contoh Konduktor mekar :

2. Jumper Konduktor

61
PENGAWASAN DAN ASESMEN SUTT/SUTET

3. Jumper Joint

4. Midspan Compression Joint

Joint Steel

Joint Aluminium

II. Sub sistem Insulation

1. Ceramic Insulator

(Ceramic Insulator jenis porselen) (Ceramic insulator jenis gelas)

62
PENGAWASAN DAN ASESMEN SUTT/SUTET

Contoh insulator flash over : Contoh insulator pecah :

2. Non-ceramic Insulator

3. ROW

63
PENGAWASAN DAN ASESMEN SUTT/SUTET

III. Sub Sistem Structure

1. Member / besi siku / bracing

(Normal) (Contoh besi siku bengkok)

2. Cat / Galvanis Tiang

3. Chimney / Kepala Pondasi

64
PENGAWASAN DAN ASESMEN SUTT/SUTET

4. Halaman Tower

(bersih) (kotor / semak)

5. Mur dan Baut Tower

6. Plat Sambungan Rangka

(Contoh kondisi normal) (Contoh kondisi plat sambungan rangka hilang)

65
PENGAWASAN DAN ASESMEN SUTT/SUTET

7. Stub

IV. Sub Sistem Junction

1. Box Joint OPGW

2. Fitting Insulator

66
PENGAWASAN DAN ASESMEN SUTT/SUTET

3. Ikatan Insulator

(normal) (ikatan insulator korosi)

4. Sealing End Kabel (Tower Transisi SUTT-SKTT)

5. Suspension/ Tension Clamp

67
PENGAWASAN DAN ASESMEN SUTT/SUTET

V. Sub Sistem Protection

1. Kawat Tanah/ GSW/ OPGW

2. Arching Horn

3. Jumper GSW

4. Konduktor penghubung kawat tanah

68
PENGAWASAN DAN ASESMEN SUTT/SUTET

5. Kawat Grounding

6. Spacer

7. Armour Rod

8. Vibration Damper

69
PENGAWASAN DAN ASESMEN SUTT/SUTET

9. Counter Weight

10. Anti Climbing Device

11. Plat Rambu Bahaya

70
PENGAWASAN DAN ASESMEN SUTT/SUTET

12. Bola Rambu

13. Aviation Lamp

14. Lampu Indikator Tower

71
PENGAWASAN DAN ASESMEN SUTT/SUTET

15. Repair Sleeve

16. Armour Rod Span

17. Transmission Line Arrester (TLA)

72
PENGAWASAN DAN ASESMEN SUTT/SUTET

VI. Sub Sistem Monitoring

1. Plat Informasi Tower

2. Baut Panjat

3. Patok Batas

73
PENGAWASAN DAN ASESMEN SUTT/SUTET

Lampiran 4 FOTO CONTOH LINGKUNGAN TOWER

Contoh Tower di dekat tebing dan lereng

Contoh jejak erosi di tapak tower karena sungai.

74
PENGAWASAN DAN ASESMEN SUTT/SUTET

Gangguan eksternal berupa aktivitas penduduk / pihak luar di halaman tower :

Contoh Jenis – jenis tanah :

Jenis tanah Merah, Lempung Jenis tanah berkerikil :

75
PENGAWASAN DAN ASESMEN SUTT/SUTET

DAFTAR ISTILAH

ACD (Anti Climb Device) : Penghalang panjat yang terletak dibawah baut panjat.

Angker : Besi penguat steel pole yang tertanam di pondasi.

Arching horn : Tanduk api sebagai proteksi petir yang memotong surja petir secara pasif.

Armor rod : pelindung konduktor berupa aluminium pada pemasangan suspension


clamp.

Asesmen : Penilaian untuk penentuan kondisi peralatan.

Aviation Lamp : Lampu rambu udara untuk pesawat terbang yang terpasang di
konduktor span/ antara tower dengan energi dari metode beda tegangan.

Ball (Ikatan Insulator) : Konektor insulator bagian bawah insulator yang


menyambungkan piringan insulator atas dengan socket piringan insulator dibawahnya.

Balok kopel : Beton bertulang yang menghubungkan empat chimney.

Baut panjat : Alat untuk fasilitas pemanjatan tower.

Body extension : Konstruksi tower yang terletak antara travers fasa bawah sampai
travers kawat tanah yang terdiri dari common body, diagonal dan diafragma.

Body section : Bagian-bagian (tabung) sambungan pada tower steel pole.

Body utama : Struktur tower bagian bawah tower lattice sebelum travers paling bawah
yang terdiri dari leg, oblique, diagonal dan diafragma.

Bola rambu : Lampu rambu udara untuk pesawat terbang yang terpasang di kawat
tanah/ GSW span/ antara tower.

Bottom : Besi horizontal pada bagian bawah travers/ cross arm.

Box joint OPGW : Kotak penghubung OPGW.

Bracing : Besi menyilang pada travers/ cross arm.

Check list : Daftar isian hasil inspeksi.

Chimney : Beton yang membungkus stub.

Climber : Pelaksana climb up inspection.

Common body : Besi utama body tower mulai dari pangkal travers fasa bawah sampai
dengan pangkal travers kawat tanah/ GSW/ OPGW.

Counter weight : Pemberat konduktor pada sisi jumper.

76
PENGAWASAN DAN ASESMEN SUTT/SUTET

Crossarm/ Travers : Bagian dari struktur tower yang berfungsi memegang insulator dan
kawat tanah, baik tower lattice maupun steel pole.

CUI : Climb Up Inspection.

Current Carrying : Komponen SUTT/SUTET yang berfungsi untuk menyalurkan arus


listrik.

Diafragma : Besi horizontal pada body tower.

Diagonal : Besi menyilang pada tower.

Fittings : Asesoris penghubung insulator dengan tower dan penghubung insulator


dengan suspension clamp / tension clamp.

Flash Over : Kelainan insulator yang terbakar karena tersambar petir.

galvanis : Cat anti karat yang melapisi besi siku.

Glonass : Global Navigation Satellite System/ Sistem navigasi satelit global, yaitu sebuah
sistem navigasi satelit sejenis GPS yang berbasis radio dan dioperasikan oleh Russian
Space Forces.

GPS : Global Positioning System, yaitu sistem navigasi untuk menentukan letak di
permukaan bumi dengan bantuan penyelarasan (synchronization) sinyal satelit. GPS
dikembangkan oleh Departemen Pertahanan Amerika Serikat.

Grouting : Penutup celah/ ruang antara pondasi dengan plat steel pole.

Insulation : Komponen SUTT/SUTET yang berfungsi untuk memisahkan bagian yang


bertegangan dengan yang tidak bertegangan, terdiri dari insulator dan insulation udara
(ROW).

Jumper pada penghantar : Konduktor penghubung pada tower tension.

Junction : Komponen SUTT/SUTET yang berfungsi untuk menyambungkan komponen


satu dengan yang lainnya.

Kawat Grounding : Kawat baja/ tembaga/ aluminium yang menyambungkan tower


dengan tanah untuk memperkecil tahanan pentanahan tower.

Kawat tanah/ Earth Wire/ GSW (Ground Steel Wire) : Kawat yang melindungi konduktor
dari sambaran petir langsung dan menghantarkan arus petir ke tanah.

Korosi : Karat yang mengakibatkan penipisan dimensi.

Lampu aviasi : Lampu rambu udara yang terpasang pada konduktor.

Lampu Indikator Tower : Lampu rambu udara untuk pesawat terbang yang terpasang di
tower dengan energi dari listrik jaringan distribusi.

Leg : Rangka utama pada body utama.

77
PENGAWASAN DAN ASESMEN SUTT/SUTET

Member/ Bracing : Bagian dari struktur yang berupa besi siku.

Midspan Compression Joint/ Joint sleeve : Alat yang digunakan untuk menyambung
kondukor.

Monitoring : Komponen SUTT/SUTET yang berfungsi sebagai identitas SUTT/SUTET


atau untuk memudahkan dalam inspeksi SUTT/SUTET.

Oblique : Besi miring yang menghubungkan leg dengan diafragma.

OPGW (Optic Ground Wire) : Kawat yang melindungi konduktor dari sambaran petir
langsung dan menghantarkan arus petir ke tanah tetapi juga berfungsi sebagai kawat
optik.

PGP : Petugas Ground patrol.

Pin (Ikatan Insulator) : Pasak antara ball dengan socket.

Piringan insulator : Pemisah antara bagian tower dengan konduktor yang bertegangan
berupa keramik, gelas atau polymer.

Protection : Komponen SUTT/SUTET yang berfungsi sebagai pengaman dari gangguan


petir, pengaman dari getaran/ stress mekanis yang ditimbulkan oleh angin, pengaman
dari ancaman/ kemungkinan gangguan akibat manusia, pengaman dari kemungkinan
gangguan akibat tertabrak pesawat udara pada SUTT/SUTET yang dekat dengan
bandara/ dekat dengan jalur penerbangan, serta pengaman dari urat konduktor putus.

Ranging meter : Alat untuk mengukur jarak.

Renceng insulator : Rangkaian insulator.

SLA (Service Level Agreement) : Kesepakatan formal yang dapat dinegosiasikan guna
mengidentifikasi harapan, tanggung jawab, dan memfasilitasi komunikasi antara penyedia
barang/ jasa (supplier) dengan pelanggannya (costumers) yang diukur dengan jangka
waktu tertentu.

Socket (Ikatan Insulator) : Konektor insulator bagian atas insulator, yang


menyambungkan ball insulator atas dengan piringan insulator dibawahnya.

Spacer : Pemisah konduktor pada pasangan dua konduktor atau lebih, baik di konduktor
span maupun di konduktor jumper.

Steel pole : Tower yang terdiri dari susunan beberapa tabung baja yang membentuk
tiang menara.

Struktur/ Structure : Rangkaian konstruksi tower.

Stub : Besi siku paling bawah dari body tower dan tertanam dipondasi.

Suspension clamp : Klem penyangga konduktor.

SUTET : Saluran tenaga listrik yang menggunakan kawat telanjang (penghantar) di udara
bertegangan diatas 245 kV sesuai standar di bidang ketenagalistrikan.

78
PENGAWASAN DAN ASESMEN SUTT/SUTET

SUTT : Saluran tenaga listrik yang menggunakan kawat telanjang (penghantar) di udara
bertegangan diatas 35 s.d 245 kV sesuai standar di bidang ketenagalistrikan.

Tension clamp : Klem penarik konduktor.

Top : Besi miring pada bagian atas travers/ cross arm.

Tower Lattice : Tower yang terdiri dari susunan beberapa besi siku yag membentuk
menara dan memiliki 4 (empat) kaki.

Tragi : Transmisi dan Gardu Induk.

Vibration damper : Peredam getaran pada konduktor atau kawat tanah.

79
PENGAWASAN DAN ASESMEN SUTT/SUTET

DAFTAR PUSTAKA

1. Republik Indonesia. 1992. Peraturan Menteri No.01.P/47/MPE/1992 tanggal 7


Februari 2009 tentang Ruang Bebas Saluran Udara Tegangan Tinggi (SUTT) dan
Saluran Udara Tegangan Ekstra Tinggi (SUTET) Untuk Penyaluran Tenaga Listrik.
Jakarta: Sekretariat Negara
2. Badan Standarisasi Nasional. 2002. Ruang bebas dan jarak bebas minimum pada
Saluran Udara Tegangan Tinggi (SUTT) dan Saluran Udara Tegangan Ekstra Tinggi
(SUTET). Jakarta: BSN
3. Pokja MROW. 2009. Buku pedoman Manajemen ROW SUTT/SUTET No. Dokumen :
1-1/HARLUR-PST/2009. Jakarta: PT PLN (Persero) Kantor Pusat.
4. Reskiana. 2013. Identifikasi Bantaran Banjir Sungai Cihideung (Titik Pengamatan :
Jalan Perwira_Desa Leuikopo). Bogor: Institut Pertanian Bogor.
5. Buku Petunjuk Manajemen ROW SUTT/SUTET SKDIR 113.K/DIR/2010.

80
CHECKLIST ASESMEN ANCAMAN KONDISI LINGKUNGAN SUTT/SUTET

Nama Unit : ………………………………… SUTT / SUTET : …………………………………………….. Sisi Pemeriksaan : A-B C-D *) Lihat gambar di bawah

No. Tower / Tiang : ……………………………………….. B-C D-A

A. Posisi Sungai F. Lereng dan Tebing H. Total Nilai

Pemeriksaan Bobot Nilai Pemeriksaan Bobot Nilai Total nilai Komponen A+B+C+D+E+F+G :

Luar 10 Ketinggian Tebing :


Lurus 5 …… Ketinggian tebing (y1) > 30 meter 7 ………………………………………………
Dalam 1 Ketinggian tebing (y1) 21 - 30 meter 5
……
B. Aliran Sungai Ketinggian tebing (y1) 11 - 20 meter 3

Pemeriksaan Bobot Nilai Ketinggian tebing (y1) 5 - 10 meter 1 H. Klasifikasi Tingkat Ancaman

Jarak Kaki Tower dengan Bibir Sungai : Ketinggian tebing (y2) > 30 meter 7 Total Score > 50 KRITIS
Jarak terdekat kaki tower dengan bibir sungai ≤ 2
51 Ketinggian tebing (y2) 21 - 30 meter 5 Total score 13 - 50 WASPADA
meter
……
Jarak terdekat kaki tower dengan bibir sungai 2 - 5
50 Ketinggian tebing (y2) 11 - 20 meter 3 Total Score 0 - 12 AMAN
meter
Jarak terdekat kaki tower dengan bibir sungai 6 - 10
13 Ketinggian tebing (y2) 5 - 10 meter 1 HASIL ASSESSMEN :
meter …………………………….
……
Jarak terdekat kaki tower dengan bibir sungai 11 -20
8 Sudut Kemiringan : I. Kesimpulan, Usul dan Saran :
meter
Jarak terdekat kaki tower dengan bibir sungai 21 -
6 sudut kemiringan (a1) lereng > 60 Derajat 7
30 meter
1 TINDAK LANJUT:
Jarak terdekat kaki tower dengan bibir sungai 31 -
4 sudut kemiringan (a1) lereng 41 - 60 Derajat 5
40 meter ………………………
……
Lebar Sungai : sudut kemiringan (a1) lereng 21 - 40 Derajat 3
2 PENGAWASAN:
Lebar sungai > 10 meter (Diukur jika terdapat sungai
13 sudut kemiringan (a1) lereng 11 - 20 Derajat 1
dengan jarak ≤ 10m dari tower) ………………………
Lebar sungai 6-10 meter (Diukur jika terdapat
10 …… sudut kemiringan (a2) lereng > 60 Derajat 7
sungai dengan jarak ≤ 10m dari tower)
Lebar sungai 3 - 5 meter (Diukur jika terdapat 3
3 sudut kemiringan (a2) lereng 41 - 60 Derajat 5
sungai dengan jarak ≤ 10m dari tower)
……
Kecepatan Arus Sungai : sudut kemiringan (a2) lereng 21 - 40 Derajat 3
………………………………………………………..

Arus sungai Cepat ( ≥1 m/s, diukur bila terdapat


5 sudut kemiringan (a2) lereng 11 - 20 Derajat 1
sungai dengan jarak ≤ 10m dari tower)

Arus sungai Sedang( 0,5 m/s - 1 m/s, diukur bila


3 …… Jarak Kaki Tower dengan Tebing J. Tim Pemeriksa
terdapat sungai dengan jarak ≤ 10m dari tower)

Arus sungai Lambat (≤ 0,5 m/s, diukur bila terdapat Jarak kaki tower dengan dasar tebing
1 6 No. Nama Tanda Tangan
sungai dengan jarak ≤ 10m dari tower) (x1) < 1 meter

Jarak kaki tower dengan dasar tebing


C. Gangguan Eksternal 5 1
(x1) 1 - 10 meter
Jarak kaki tower dengan dasar tebing ……
Pemeriksaan Bobot Nilai 4 2
(x1) 11 - 20 meter
Jarak kaki tower dengan dasar tebing
Penimbunan sampah 25 3 3
(x1) 21 - 30 meter
Jarak kaki tower dengan dasar tebing
Bangunan di halaman tower 20 …… 2 K. Mengetahui
(x1) 31 - 40 meter
Jarak kaki tower dengan jurang tebing
Aktivitas penduduk / pihak luar, di halaman tower 15 6 No. Nama Tanda Tangan
(x2) < 1 meter
Jarak kaki tower dengan jurang tebing
D. Jejak Gangguan 5 1
(x2) 1 - 10 meter
Jarak kaki tower dengan jurang tebing Penentuan sisi pemeriksaaan dilihat pada gambar
Pemeriksaan Bobot Nilai 4 ……
(x2) 11 - 20 meter berikut :
Jarak kaki tower dengan jurang tebing
Jejak longsoran radius < 7 meter dari pondasi 30 …… 3
(x2) 21 - 30 meter (No. Tower Kecil)
Genangan air permanen dan bukan design tower Jarak kaki tower dengan jurang tebing
10 …… 2
tersebut (x2) 31 - 40 meter
Retakan terbuka 10 …… G. Tanah dan Batuan
Terdapat jejak erosi pada radius 7 meter dari A Sisi A-B B
8 …… Pemeriksaan Bobot Nilai
pondasi
Terdapat mata air pada radius 7 meter dari pondasi 8 …… Tanah Organik, gambut 16

Genangan air temporer 5 …… Tanah urug, Sirtu 15

Retakan tertutup (Kecuali tanah sawah kering) 5 …… Tanah merah, berpasir 13 Sisi D-A Sisi B-C

E. Vegetasi Penutup Tanah merah, lempung 11


Pemeriksaan Bobot Nilai Tanah berkerikil 10 ……

Tanah garapan basah (sawah) 5 Tanah batu berpasir 8


Tanah terbuka 4 Tanah berbatu 6 Sisi C-D
D C
Tanah garapan kering 3 …… Batuan campur tanah 5
Pohonan Keras 2 Batuan kali/ Cadas 3
(No. Tower Besar)
Rumput alang-alang 1 Batuan Granit 1
PT PLN (Persero)

CHECKLIST ASESMEN ANCAMAN KONDISI PONDASI TOWER LATICE

Nama Unit : ……………………………… SUTT / SUTET : ……………………………………. No. Tower / Tiang : …………

NO KOMPONEN URAIAN PEMERIKSAAN BOBOT NILAI ASESMEN

1 Kelainan pada salah satu kaki stub (Bengkok, defleksi, dsb) 50 …………..

2 Ada perubahan jarak antar kaki, diagonal dan level. 50 …………..

3 Warna galvanis sudah berubah (hitam) 5


STUB
4 Korosi pada permukaan 10 …………..

5 Korosi dan penipisan dimensi 15

Ada air, tanah, jerami dengan jarak kurang dari 10 cm dari


6 5 …………..
permukaan chimney

7 Pecah / Gompal sampai terlihat tulangan 40


CHIMNEY …………..
8 Retak 30

9 BALOK KOPEL*) Pecah 10 …………..

TOTAL NILAI ASESMEN …………..

Hasil Asesmen : …………..


Keterangan :
- *) Jika Ada

KLASIFIKASI TINGKAT ANCAMAN TINDAK LANJUT : PENGAWASAN :


Total score > 60 KRITIS

Total score 31 - 60 WASPADA ………….. …………..

Total Score 0 - 30 AMAN

Mengetahui, ……………,……………………………………
…………………………………………. Pemeriksa

(…………………………………….) (………………………………………..)
PT PLN (Persero)

CHECKLIST ASESMEN ANCAMAN KONDISI PONDASI TOWER STEEL POLE

Nama Unit : ……………………………… SUTT / SUTET : ……………………………………. No. Tower / Tiang : …………

NO KOMPONEN PEMERIKSAAN BOBOT NILAI ASESMEN

1 Mur Kurang Kencang 50 …………..

2 Drat Kurang Panjang (min 2 ulir) 10 …………..

3 ANGKUR Terjadi korosi dan penipisan dimensi 40

4 Korosi pada permukaan 15 …………..

5 Warna galvanis sudah berubah (hitam) 10

6 Pecah/ Gompal sampai terlihat tulangan 30


CHIMNEY …………..
7 Retak 20

TOTAL NILAI ASESMEN …………..

Hasil Asesmen : …………..

KLASIFIKASI TINGKAT ANCAMAN TINDAK LANJUT : PENGAWASAN :


Total score > 60 KRITIS
Total score 31 - 60 WASPADA ………….. …………..
Total Score 0 - 30 AMAN

Mengetahui, ……………,……………………………………
…………………………………………. Pemeriksa

(…………………………………….) (………………………………………..)

Anda mungkin juga menyukai