MODEL SET INFUS TERUMO
Ô  
     ! 
   Ô   
 
Ô !

Position ± 1 TERUMO 15 drops/mL TS*PA200B (for pumps)


( Initial Setting) (TS*PA Series) TS*PA200BI (for pumps)
TS*PA200 (for pumps)
TS*PA300L (for pumps)

60 drops/mL TS*PM270L (for pumps)


(TS*PM Series) TS*PM370L42(for pumps)
Position ± 2 TERUMO 15 drops/mL TS*A200BXK
( Initial Setting) (TS*A Series) TS*A200BXK33
TS*A200LK
TS*A200LK002
TS*A200LK9
TS*A400LK379
TS*A456CK9
60 drops/mL TK*A200BXK
(TK Series) TK*A200LK
TK*A200LK9

m       



 
   
„ PASANG INFUS PUMP PADA TIANG INFUS
„ PASANG STEKER LISTRIK PADA STOP KONTAK
„ HIDUP INFUS PUMP DENGAN MENEKAN
TOMBOLPOWER / ON
„ PADA LAYAR LCD AKAN MUNCUL TANDA JJJJ
BERARTI POSITION ± 1 AKTIF ATAU SET INFUS YANG
DIGUNAKAN ADALAH SET PUMP ( TS*PA Seris ATAU
TS*PM Series), BILA MUNCUL TANDA tttt BERARTI
POSITION -2 AKTIF ATAU SET YANG DIGUNAKAN
ADALAH TK* Series ATAU TS*A Series
„ LALUKAN PREME PADA INFUS SET, PASTIKAN TIDAK
ADA GELEMBUNG UDARA DAN TUTUP/KUNCI KLEM
INFUS.

m       


„ BUKA PINTU INFUS PUMP LALU MASUKKAN SELANG
INFUS JALUR INFUS, BUKA KLEM DENGAN MENARIK
KLEM KE KIRI. LALU KLEM DITUTUP KEMBALI.
PASTIKAN SET INFUS TERPASANG LURUS PADA
JALURNYA JANGAN SAMPAI TERLIPAT ATAU
TERTEKUK. LALU TUTUP KEMBALI PINTU.
„ PASANG DRIP SENSOR PADA DRIP TUBE, DENGAN
CARA MENEKAN SISI KIRI DAN KANAN DRIP SENSOR.
PEMASANGAN DRIP SENSOR HARUS TERLETAK
ANTARA DRIP NOOZEL DAN BATAS ATAS CAIRAN
PADA DRIP TUBE. BUKA KLEM PENGATUR TETESAN
INFUS SECARA PENUH.
„   
  
 

 O 



 

 m          


„ ATUR JUMLAH TETESAN INFUS PADA D.Rate«««mL/Hour DENGAN MENEKAN
TOBOL:

: naik 10 angka : naik 1 angka

: turun 10 angka :turun1 angka

„ BILA INGIN MEMBATASI JUMLAH CAIRAN YANG INGIN DIMASUKKAN DENGAN


MENEKAN TOBOL SELECT MAKA AKAN MUNCUL D.LIMIT :««..mL. DENGAN
MENEKAN TOBOL:

: naik 100 angka : naik 1 angka

: turun 100 angka :turun1 angka

„ PASTIKAN D.Limit TIDAK DISET DENGAN ANGKA 0. KARENA INFUS PUMP TIDAK
AKAN BERFUNGSI.
„ SESUAIKAN FAKTOR TETESAN INFUS SENGAN MENEKAN TOMBOL INFUS SET.
„ TEKAN TMBOL START UNTUK MEMULAI MENJALANKAN INFUS PUMP.

m       


J 
   
      
 
    

   (  
    
 )        
 
 

 )       


 m     (  
  
     
 î 
   

m       


 
     
!           
*  +         
+    

, - +    


+       

  + 
 .    /
+             
î +   
   +( 
î0   
 

Perhatian:
-Sebelum membuka pintu, catat dulu jumlah Ȉ ml, dan tutup dulu pengatur tetesan.
-Untuk membuka dan memasang drip sensor dengan cara menekan sisi kiri dan kanan drip
m       
  
„ RUMUS:
order tetesan infus X jam dalam menit
Faktor tetesan infus
Contoh:
Ny. E dirawat dan harus dipasang infus 20 tetes/ menit dengan
faktor tetesan infusnya 15. berapa jumlah cairan yang harus
masuk perjamnya?
Jawab:
20 tetes X 60 menit
15
= 1200
15
= 80
maka jumlah cairan yang harus masuk adalah 80 cc/jam