(KOMPRESOR)
0,9 26 8 30 32 28 28 28 205 5
1,2 17 29 13 39 27 28 27 220 5
1,8 9 27 3 42 28 28 28 230 5
II. PENGOLAHAN DATA HASIL PENGAMATAN
PERCOBAAN 1
P1 = 2 kg/cm2
P1 = Po + 9,678 x 10-1 x P1
P1 = 1 atm + 9,678 x 10-1 x 0,9 kg/cm2
P1 = 0,9710 atm abs
PERCOBAAN 2
P1 = 3 kg/cm2
P1 = Po + 9,678 x 10-1 x P1
P1 = 1 atm + 9,678 x 10-1 x 1,2 kg/cm2
P1 = 1,2614 atm abs
PERCOBAAN 3
P1 =2 kg/cm2
P1 = Po + 9,678 x 10-1 x P1
P1 = 1 atm + 9,678 x 10-1 x 1,8 kg/cm2
P1 = 1,8420 atm abs
2.2. Menentukan P2 yang dikonversikan kedalam satuan atm absolut.
PERCOBAAN 1
P2 = 5 mmH2O
P2 = Po – 9,678 x 10-5 x P2
P2 = 1 atm – 9,678 x 10-5 x 26 mmH2O
P2 = 1,0025 atm abs
PERCOBAAN 2
P2 =6mmH2O
P2 = Po – 9,678 x 10-5 x P2
P2 = 1 atm – 9,678 x 10-5 x 17 mmH2O
P2 = 1,0016 atm abs
PERCOBAAN 3
P2 = 8 mmH2O
P2 = Po – 9,678 x 10-5 x P2
P2 = 1 atm – 9,678 x 10-5 x 9 mmH2O
P2 = 1,0009 atm abs
PERCOBAAN 1
P3 =10 mmH2O
P3 = Po + 9,678 x 10-5 x P3
P3 = 1 atm + 9,678 x 10-5 x 8 mmH2O
P3 = 1,0008 atm abs
PERCOBAAN 2
P3 = 15 mmH2O
P3 = Po + 9,678 x 10-5 x P3
P3 = 1 atm + 9,678 x 10-5 x 29 mmH2O
P3 = 1,0028atm abs
PERCOBAAN 3
P3 = 16 mmH2O
P3 = Po + 9,678 x 10-5 x P3
P3 = 1 atm + 9,678 x 10-5 x 27 mmH2O
P3 = 1,0026 atm abs
𝑷𝟐 𝑷𝟐
xi= ln [𝑷𝟏] rp = 𝑷𝟏
PERCOBAAN 1
𝟐𝟔
xi = ln [𝟎,𝟗] = 3,363
𝟐𝟔
rp = [𝟎,𝟗] = 28,9
PERCOBAAN 2
𝟏𝟕
xi = ln [𝟏,𝟐] = 2,708
𝟏𝟕
rp = [𝟏,𝟐] = 14,2
PERCOBAAN 3
𝟗
xi = ln [𝟏,𝟖] = 1,609
𝟗
rp = [𝟏,𝟖] =5
Tabel 1
P1 P2 P3
No rp
(mmH2O) (Kg/cm2) (mmH2O)
1 0,9 26 8 28,9
2 1,2 17 29 14,2
3 1,8 9 27 5
Tabel 2
NO x x2
1 3,363 11,310
2 2,708 7,333
3 1,609 2,589
∑ 7,68 21,232
a = 0,0932
𝒏−𝟏
a=
𝒏
an = n – 1
1 = n – an
1 = ( 1 – a )n
1
n=
1−𝑎
1
n=
1− 0,0932
1
n=
0,9068
n = 1,103
2.5. Menentukan Aliran Massa uap Air Masuk (mvin)
Ditentukan rasio kandungan air per udara kering (1) = 0,01 kg air per kg udara. Sehingga
laju aliran massa uap masuk :
𝜸𝟏
mvin = 𝜸+𝟏 . 𝒎𝒂
0,01
mvin = 0,01+1 . 4,7479 x 10-3
0,01
mvin = 1,01 . 4,7479 x 10-3
Ditentukan rasio kandungan air per udara kering (1) = 0,009 kg air per kg udara. Sehingga
laju aliran massa uap ai keluar :
𝜸
mvout = . 𝒎𝒂
𝜸+𝟏
0,009
mvout = 0,009+1 . 4,7479x 10-3
0,009
mvout = 1,009 . 4,7479 x 10-3
Wiso = ma . R . T1 . ln(rp)
Wiso = 4,7479 x 10-3 x 0,287 x 32 x ln(5)
Wiso = 4,7479 x 10-3 x 0,287 x 32 x 3,375
Wiso = 0,6198kW
Wmek = V . A
Wmek = 220 . 5
Wmek = 1100 W
Wmek = 1.1 kW
𝑊
pol = 𝑊 𝑝𝑜𝑙 𝑥 100%
𝑚𝑒𝑘
0,1658
pol = 𝑥 100%
1,1
𝑊
iso = 𝑊 𝑖𝑠𝑜 𝑥 100%
𝑚𝑒𝑘
0,6198
iso = 𝑥 100%
1,1
iso = 68,178 %
2.12. Menentukan Efisiensi Volumetrik
𝑚𝑎
vol = 𝑊 𝑥 100%
𝑚𝑒𝑘
4,7479
vol = 𝑥 100%
1,1
Tabel 3 . Laju Aliran Massa Udara dan Laju Aliran Massa Uap Air
= 1962,5 x 40
= 78500 mm3
= 1962,5 𝑥 1,65
= 3238,13 mm3
Banyaknya gas didalam ruang kompresi adalah banyaknya gas yang akan dimampatkan oleh
torak untuk setiap langkah kompresi yang dilakukan permenit didalam silinder compressor
adalah :
(𝑸 .𝑻𝟏)𝑷𝒐
V= 𝑻𝒐 .𝑷𝟏
(𝑸 .𝑻𝟏)𝑷𝒐
Maka : V= 𝑻𝒐 .𝑷𝟏
V = {(0,2.44).1}/{273.3,375}
V = 0,0095 m3/min
❖ Pada langkah 1 -2
A = P1 x V1n
A = 3,375x (81738,13)1,1
A = 3,375 x 253318,65
A =8,549x 102 atm mm3
V2 = (A/P2)n
V2 = (9888,04 x 102 / 0,9988)1,1
V2 = (989991,99) 1,1
V2 = 3937266,84
V2 = 3,94 x 106 mm3
V4 = (B/P4)n
V4 = (3242,02 / 3,9034)1,1
V4 = (830,56)1,1
V4 = 1626,71
V4 = 1,6 x 103 mm3
Langkah 1 - 2
No A P2 = P3 V2
Langkah 3 - 4
No B P4 = P1 V4
1 -16.9776 4.1667
2 -46.1274 8.7500
3 -41.3626 8.3333
4 -74.4478 12.500
WPOL VS RP
Wpol VS rp
0,0000
4.1667 8.7500 8.3333 12.500
Kerja Politropik
-20,0000
(kW)
-40,0000
-60,0000
-80,0000
Beda Tekanan (rp)
Tabel Efisiensi Politropik (pol) VS Beda Tekanan (rp)
1 -16.9776 4.1667
2 -46.1274 8.7500
3 -41.3626 8.3333
4 -74.4478 12.500
EFISIENSI POL VS RP
Efisiensi Pol VS rp
0,0000
Efisiensi Politropik
-40,0000
-60,0000
-80,0000
Beda Tekanan (rp)
3.3 Grafik Kerja Isotermal (Wiso) VS Beda Tekanan (rp)
WISO VS RP
Wiso VS rp
2,0000
Kerja Isotermal
1,5000
(kW)
1,0000
0,5000
0,0000
4.1667 8.7500 8.3333 12.500
Beda Tekanan (rp)
Tabel Efisiensi Isotermal (iso) VS Beda Tekanan (rp)
1 0.5989 4.1667
2 1.1778 8.7500
3 1.0840 8.3333
4 1.5494 12.500
EFISIENSI ISO VS RP
Efisiensi iso VS rp
2,0000
Efisiensi Politropik
1,5000
1,0000
(%)
0,5000
0,0000
4.1667 8.7500 8.3333 12.500
Beda Tekanan (rp)
1. Tabel Efisiensi Volumetrik (vol) VS Beda Tekanan (rp)
1 0.0047479 4.1667
2 0.0061628 8.7500
3 0.0057837 8.3333
4 0.0069175 12.500
EFISIENSI VOL VS RP
Efisiensi Vol VS rp
0,008
Efisiensi Volumetrik
0,006
0,004
(%)
0,002
0
4.1667 8.7500 8.3333 12.500
Beda Tekanan (rp)
Tabel Laju Aliran Massa Uap Air Masuk (mvin) VS Beda Tekanan (rp)
1 0.000047004 4.1667
2 0.000061012 8.7500
3 0.000057259 8.3333
4 0.000068483 12.500
3.6 Grafik Laju Aliran Massa Uap Air Keluar (mvout) VS Beda Tekanan (rp)
MV IN VS RP
mv in VS rp
0,00008
0,00006
(kg/s)
mv in
0,00004
0,00002
0
4.1667 8.7500 8.3333 12.500
Beda Tekanan (rp)
Tabel Laju Aliran Massa Uap Air Keluar (mvout) VS Beda Tekanan (rp)
1 0.00004236 4.1667
2 0.000054772 8.7500
3 0.000051591 8.3333
4 0.000061764 12.500
3.7 Grafik Laju Aliran Massa Uap Air Keluar (mvout) VS Beda Tekanan (rp)
MV OUT VS RP
mv out VS rp
0,00008
0,00006
mv out
(kg/s)
0,00004
0,00002
0
4.1667 8.7500 8.3333 12.500
Beda Tekanan (rp)