V2
eu gz
2
1. W s 0 , W other 0
2. W shear 0 (meskipun tegangan geser ada pada dinding elbow, namun kecepatan
aliran sama dengan nol pada dinding)
3. Aliran Steady
4. Aliran incompressible
5. Energi dalam dan tekanan seragam pada penampang 1 dan 2
Head Loss Total (hLT) :
2
p p V
u 2 u1 m
m
Q 2 1
g z 2 z1 A
m
2 V2 dA2
2 2
V22
A V1 dA1
1 2
p p 2V22 1V12
Q m u2 u1 m m g z2 z1 m
2 1
2 2
Q p2 p1 2V22 1V12
u2 u1 g z2 z1
dm 2 2
p1 V 2 p2 V 2 Q
1 1 gz 2 gz u u
1 2 1 2 1
2 2 dm
p1 V 2 p2 V 2 Q
1 1
gz1 2 2 gz1 hlT hlT u 2 u1
2 2 dm
Koefisien Energi Kinetik () :
3
V dA
A
V 2
V 2
V 2 m V 2
V dA V dA m
A 2 A 2 2
3
U 2n 2
V 3 n 3 2n
Dimana :
U adalah kecepatan aliran maksimum pada centerline pipa
V adalah kecepatan aliran rata-rata pada pipa
n adalah power-law eksponen yang besarnya 6, 7, 8, ……
p1 V 2 p V 2
1 1 gz 2 2 gz hl
2
1 2
2
1 T
hlT hl hlm
dimana :
hl adalah head loss mayor (kehilangan energi pada pipa lurus
(straight pipe))
hlm adalah head loss minor (kehilangan energi pada elbow,
sudden enlargement, sudden contraction, tee, cross fitting,
entrance, exit, valve)
Perhitungan Pressure Drop
pada Sistem Perpipaan
Head Loss Mayor, hl
1 e D 2.51
Persamaan Colebrook :
2.0 log 0.5
f 0.5 3.7 Re d f
Untuk mendapatkan harga f dari persamaan Colebrook digunakan metode iterasi.
hl L
kC D pipe
Perhitungan dengan menggunakan Hazen-Williams friction loss
equation dan hanya valid untuk air dengan temperatur tipikal
seperti sistem suplai air perkotaan (40 to 75 oF atau 4 to 25 oC).
Harga C dapat dilihat pada tabel.
k = unit conversion factor = 1.318 (English units)
= 0.85 (Metric units)
Head Loss Mayor, hlm
Head Loss Minor, hlm
Head loss minor (hlm) terjadi jika fluida melalui fitting (tee, elbow,
sudden enlargement, sudden contraction) dan valve
Lift or Piston
Check Valve
Globe Valve
Head Loss Minor, hlm
p1 V1 2 p2 V 22 V2
1 z1 2 z2 K L
2g 2g 2g
p1 V1 2 p2 V 22 Le V 2
1 z1 2 z2 f
2g 2g D 2g
Dimana :
KL adalah koefisien losses
Le/D adalah equivalent length
f adalah friction factor
Head Loss Minor, hlm
Apabila fitting (sudden enlargement, sudden contraction, dan elbow 90 0)
dalam posisi horisontal, sehingga perbedaan elevasinya sama dengan nol
atau z1 = z2, maka persamaan untuk :
1. Sudden Enlargement :
2. Sudden Contraction :
p1 p 2 V2 p1 p2 Le V 2
K L elbow atau
f
2g D 2g
Head Loss Minor, hlm
1. Sudden Enlargement :
2. Sudden Contraction :
Kasus 1 :
LV2
4Q 16Q 2
p1 p2
z2 z1 f V 2
V
D 2g D 2pipe 2 D 4pipe
P12 LV2
z2 z1 f
D 2g
2 8Q 2
P1 2 g z2 z1 gf
L 8Q P1 2 g z 2 z1 fL
D g 2 D 4pipe 2 D 5pipe
SISTEM PERPIPAAN – SINGLE LINE
Kasus 2 : Asumsi :
Aliran steady
Aliran incompressible
Aliran turbulent fully developed
Material pipa berdiameter D1
sama dengan pipa berdiameter
D2.
2
V22 V12 L1 V12 L2 2
V2 V
P1 2 g z 2 z1 g g f1
D 2g f 2 K SC 2
2g 2g D 2 g 2 g
2
1
head loss mayor head loss minor
g 4Q V1 D1 4Q V2 D2
V1 Re D1 V2 Re D 2
D12 D22
SISTEM PERPIPAAN – SINGLE LINE
Kasus 3 : Asumsi :
Aliran steady
Aliran incompressible
Aliran turbulent fully developed
Material pipa lurus dan elbow
900 adalah sama.
Diameter pipa lurus dan elbow
900 konstan
p1 V12 p2 V22
1 z1 2 z2 hLT12
2g 2g
2 2
V L1 L2 L3 Le V
P1 2 g z 2 z1 g f1 2 f2
2 g D pipe D 2 g
pipe
head loss mayor head loss minor
SISTEM PERPIPAAN – SINGLE LINE
Asumsi :
Kasus 4(a) :
Aliran steady
Aliran incompressible
Aliran turbulen fully developed
P1 = P2 = Patm
V1 = 0, karena Dreservoir >> Dpipa
p1 V12 p2 V22 2
V2
z1 z2 hLT12 hLT12
L1 L2 V
hl hlm f
K gatevalve K entrance
2g 2g D 2g
2g
head loss mayor head loss minor
V22
h z1 z2 hLT12
2g
V22 V 2 V2
h z1 z 2
2g
L L2
f 1
D
K gate valve K entrance
2g 2g
head loss mayor head loss minor
SISTEM PERPIPAAN – SINGLE LINE
Asumsi :
Kasus 4(b) :
Aliran steady
Aliran incompressible
Aliran turbulen fully developed
P1 = Patm
P2 = Patm + P2gage
V1 = 0, karena Dreservoir >> Dpipa
p1 V12 p2 V22 L1 L2 V
hl hlm f
2
K gate valve K entranceV2
z1 z2 hLT1 2 hLT12
D 2g 2g
2g 2g
head loss mayor head loss minor
V V 4Q
2 2 2 2 2
p2 gage g z1 z2
V2
2
g f 1
L
D 2g
L2
V
K gate valve K entrance
V
2g
D pipe
head loss mayor h z z
head loss minor 1 2
SISTEM PERPIPAAN – SINGLE LINE
Kasus 4(c) : Asumsi :
Aliran steady
Aliran incompressible
Aliran turbulen fully developed
P1 = Patm+ P1gage
P2 = Patm+ P2gage
V1 = 0, karena Dreservoir >> Dpipa
V22 L L V 2 2
p 2 gage p1 gage g z1 z 2
2
g f 1
D 2g
2
2
K gate valve K entrance
V 2
2g
head loss mayor head loss minor
SISTEM PERPIPAAN – SINGLE LINE
Asumsi : P1 = P2 = Patm
Aliran steady P3 = Patm + P3gage
Aliran incompressible V1 = 0, V2 = 0, karena Dreservoir >> Dpipa
Aliran turbulen fully developed
Material pipa lurus sama dengan material
elbow 900.
Tentukan perbedaan ketinggian z1-2= z1 – z2
SISTEM PERPIPAAN – SINGLE LINE
V22 4Q
z1 z 2 hL V
2g T 12 D 2pipe
V 2 L1 L2 L3 L4 L5
hLT12 hl hlm f
2g D
head loss mayor
Le V 2
K valve K entrance K exit 2 f
D elbow 900 2 g
head loss minor
V 2 L1 L2 L3 L4 L5
z 12 z1 z 2 hlT12 f
2g D
head loss mayor
L V 2
K valve K entrance K exit 2 f e
D elbow 900 2 g
head loss minor
SISTEM PERPIPAAN – SINGLE LINE
P1 = P2 = Patm
Asumsi :
Aliran steady P3 = Patm + P3gage
Aliran incompressible V1 = 0, V2 = 0, karena Dreservoir >> Dpipa
Aliran turbulen fully developed Material pipa lurus sama dengan material
elbow 900.
Tentukan tekanan gage pada titik 3 (P3gage)
SISTEM PERPIPAAN – SINGLE LINE
Menentukan P3gage dari titik 1 ke 3 :
p1 V12 p3 V32
z1 z3 hlT13
2g 2g
V 2 L1 L2 L3 L4 Le V 2
hlT13 hl hlm f K valve K entrance 2 f
2g D D
90 0 2 g
elbow
head loss mayor head loss minor
4Q
V3 V
D pipe
2
V32 L L2 L3 L4 Le
p3gage g z1 z3 1 f 1 K valve K entrance 2 f
2 D D elbow900
head loss mayor head loss minor
SISTEM PERPIPAAN – SINGLE LINE
Menentukan P3gage dari titik 3 ke 2 :
p3 V32 p2 V22
z3 z2 hlT3 2
2g 2g
V 2 L5 V2
hlT3 2 hl hlm f K exit
2g D 2g
head loss mayor head loss minor
4Q
V3 V
D 2pipe
V32 L5
p3gage g z 2 z3 1 f D K exit
2
Contoh Soal Kasus 1
Pipa lurus berdiameter 10 inch (1 inch = 25,4 mm) didalamnya mengalir minyak
(SG = 0.87) dengan debit aliran 360 m3/jam (temperatur minyak di dalam pipa
diasumsikan konstan sebesar 200C), apabila perbedaan tekanan antara
pressure gage 1 dan 2 (P1-2) adalah 40 kPa, jika diketahui jenis pipa adalah
pipa GIP (galvanized iron pipe) dengan kekasaran permukaan pipa absolut (e)
= 0.15 mm dan perbedaan ketinggian antara pressure gage 1 dan 2 (z2-1) = 1
meter. (air = 999 kg/m3, = 1 x10-4 m2/s, dan g = 9.8 m/s2). Gunakan
persamaan friction loss (f) untuk 4 x 103 < Red < 1 x 108 dan 10-6 < e/D < 10-2
1.325
f 2 Kasus 1 :
e D 5.74
ln
3 . 7 0.9
Re d
V D pipa
Re D
H p z 2 z1 h L T12
V 2 L1 2 L
H p z 2 z1 f 2 f e K entrance K exit K ball valve
2g D D
8Q 2 L1 2 Le
H p z 2 z1 2 4 f 2f K entrance K exit K ball valve
D pipe g D pipe D
Menentukan Daya Pompa (P) :
gQHp
P Watt 1 HP = 746 Watt
pompa
gQHp
P Horse Power
746 pompa
Dimana :
= densitas fluida (kg/m3)
g = 9,8 m/s2
Q = debit aliran fluida (m3/s)
Hp = Head Pompa (m)
pompa = Effisiensi Pompa