Daya dukung lateral tiang (H) dihitung dengan persamaan :
H = yo * kh D / [ 2 * β * (e * β + 1 ) ] dengan, β = √ [kh * D / ( 4 * Ep * Ip ) ]
D = diameter tiang pancang (m), D= 0,40 m
t = tebal tiang pancang, t= 0,016 m L = panjang tiang pancang (m), L= 23,00 m kh = modulus subgrade horisontal (kn/m³), kh = 10750 kN/m³ Ep = modulus elastis tiang baja (kN/m²), Ep = 2,10E+08 kN/m² Ip = momen inersia penampang (m⁴) Ip = π / 64 * [ D⁴ - ( D - t)⁴] = 0,00019 m⁴ e = jarak beban lateral terhadap muka tanah (m), e= 0,10 m yo = defleksi tiang maksimum (m). yo = 0,006 m β = koefisien defleksi tiang, β = √ [kh * D / ( 4 * Ep * Ip ) ] = 0,164479 m β*L= 3,783015 > 2.5 maka termasuk tiang panjang Daya dukung lateral tiang pancang, H = yo * kh * D / [ 2 * β * (e * β + 1 ) ] = 77,16038
2.2. BERDASARKAN MOMEN MAKSIMUM
Tegangan leleh baja, fy = 240000 kN/m²
Tahanan momen, W = Ip / ( D / 2 ) = 0,000946104 m³ Momen maksimum, My = fy * W = 227,0649 kN/m Kohesi tanah rata-rata di sepanjang tiang Kedalaman L1 Cu NO Cu * L1 z1 (m) z2 (m) (m) (kN/m²) 1 0,00 24,20 14,2 9,00 127,80 2 24,20 25,60 11,4 18,00 205,20 3 25,60 29,60 4,0 24,00 96,00 4 29,60 32,40 2,8 32,00 89,60 5 32,40 40,00 7,6 12,00 91,20 Ʃ L1 = 40,0 ƩCu * L1 = 609,80 Kohesi tanah rata-rata, ču = Ʃ [Cu * L1] / ƩL1 = 15,245 kN/m² f = Hu / [ 9 * ču * D ] pers.(1) g = L - ( f + 1.5 * D ) pers.(2) My = Hu * ( e + 1.5 * D + 0.5 * f ) pers.(3) My = 9 / 4 * D * ču * g² pers.(4) Dari pers.(1) : f = 0.01822 Hu Dari pers.(2) : g = 39.40 - 0.01822 * Hu g² = 0.00033 * Hu² - 1.43581 * Hu 1552.36 9/4 * D * cu = 13.7205 Dari pers.(3) : My = Hu * ( 0.700 * 0.00911 * Hu ) My = 0.00911 * Hu² * 0.70000 * Hu Dari pers.(4) : My = 0.00456 * Hu² - 19.700 * Hu 21299.2 Pers.kuadrat : 0= 0.00456 * Hu² 20.4000 * Hu - 21299.2 Dari pers.kuadrat, diperoleh tahanan lateral ultimit, Hu = 873,645 kN f= 15,9186 m Mmax = Hu * ( e + 1.5 * D + 0.5 * f ) = 7565,16 kNm Mmax > My Termasuk tiang panjang Dari.pers(3) : My = Hu ( 0.700 0.00911 * Hu ) My = 172.974 = 0.00911 * Hu² 0.70000 * Hu Pers.kuadrat 0 = 0.00911 * Hu² 0.70000 * Hu - 172.974 Dari persamaan kuadrat, diperoleh tahanan lateral ultimit, Hu = 104,629 kN SF = 1,5 H = Hu / SF = 69,75 kN 2.3. REKAP DAYA DUKUNG LATERAL TIANG
No Uraian Daya Dukung Aksial Tiang Pancang H (kN)
1 Berdasarkan defleksi tiang maksimum 67,19 2 Berdasarkan momen maksimum 69,75 Daya dukung aksial terkecil, H= 67,19 kN Diambil daya dukung lateral tiang pancang, H ijin = 67,00 kN
3. ANALISIS FONDASI ABUTMENT
3.1. DATA FONDASI ABUTMENT
BAHAN / MATERIAL FONDASI TIANG PANCANG BAJA
Mutu beton, K- 250 Tegangan leleh baja, Kuat tekan beton, fc ' = 20,8 Mpa fy = 240000 kPa Mutu baja tulangan, U- 32 Diameter tiang pancang, Tegangan leleh baja, fy = 320 Mpa D= 0,40 m Modulus elastis beton, Ec = 21410 Mpa Panjang tiang pancang, Berat beton bertulang, Wc = 25 kN/m³ L= 23,00 m DIMENSI PILE CAP Lebar arah x, Bx = 4,50 m Tebal, hp = 0,80 m Lebar arah y, By = 7,50 m Tebal, ht = 1,20 m Depan, L1 = 1,50 m Belakang, L2 = 1,50 m
DATA SUSUNAN TIANG PANCANG BAJA
Jarak pusat tiang terluar terhadap sisi liar pile-cap a= 0,34 m Jumlah baris tiang pancang, ny = 5 buah Jumlah tiang pancang dalam satu baris, nx = 3 buah Jarak antara tiang pancang arah x, X= 1,50 m Jarak antara tiang pancang arah y, Y= 1,50 m