Anda di halaman 1dari 3

Menghitung Efisiensi Panel Surya

A. Name Plate

Max Power (Pmax) 180 W


Open Circuit Voltage (Voc) 30.4 V
Short Circuit Current (Isc) 8.03 A
Min. Bypass Diode (If) 12.5 A
Serial No NC081015E069073
Warranted Min Pmax 174.6 W
Max. Power Current (Vmp) 24.2 V
Max. Power Current (Imp) 7.45 A
Fuse Rating 15 A
AT STC 1000 W/m2, AM 1.5, cell T 25oC
Measured Values at STC IEC
Pmax 180.1 W
Vmp 24.5 V
Imp 7.34 A
Voc 30.2 V
Isc 8.36 A

B. Jumlah Array

Di Lab Surya Teknik Konversi Energi terdapat 3 array pembangkit listrik

tenaga surya.

- 1 array besar statis

- 2 array kecil dinamis (bisa digerak-gerakkan/diarahkan)

C. Jumlah Panel

Array Besar 92 panel


Array Kecil A 5 panel
Array Kecil B 5 panel

D. Jumlah Modul

1 panel = 50 modul

Array Besar 4600


modul
Array Kecil A 250 modul
Array Kecil B 250 modul

E. Perhitungan Efisiensi

Panel

Lebar : 80.95 cm

Panjang : 163.4 cm

Luas =pxl

= 163.4 cm x 80.95 cm

= 13227.23 cm2 = 1.322723 m2

Paktual = 180 watt

Pteori = 1.322723 m2 x 1000 watt

= 1322.723 watt

η = (Wakt/Wteori)x100%
= (180 W/1322.73 W)x100%

= 13.61 %