DAFTAR ISI

DAFTAR ISI..................................................................................................................i
DAFTAR GAMBAR....................................................................................................ii
DAFTAR TABEL........................................................................................................iii
DAFTAR NOTASI......................................................................................................iv
BAB I PENDAHULUAN.............................................................................................1
1.1 Tujuan Percobaan............................................................................................1
1.2 Dasar Teori......................................................................................................1
BAB II METODOLOGI PERCOBAAN......................................................................8
2.1 Alat dan Bahan................................................................................................8
2.2 Skema Alat Percobaan....................................................................................9
2.3 Variabel Percobaan.........................................................................................8
2.4 Cara Kerja.......................................................................................................9
2.5 Diagram Alir Percobaan.................................................................................9
BAB III HASIL DATA DAN PEMBAHASAN.........................................................11
3.1 Hasil Data.........................................................................................................11
3.2 Pembahasan......................................................................................................12
BAB IV KESIMPULAN DAN SARAN.....................................................................19
4.1 Kesimpulan.......................................................................................................19
4.2 Saran.................................................................................................................19
DAFTAR PUSTAKA..................................................................................................20
LAMPIRAN................................................................................................................21
I. Hasil Data Perhitungan.........................................................................................21
II. Appendiks Perhitungan........................................................................................23
III. Dokumentasi Percobaan...................................................................................29

i
DAFTAR GAMBAR

Gambar 1 Komponen Pompa Sentrifugal (Tampak Samping)......................................2


Gambar 2 Komponen Pompa Sentrifugal (Tampak Depan).........................................2
Gambar 3 Kurva Krakteristik Pompa Sentrifugal.........................................................2
Gambar 4 Contoh Kerusakan Impeller akibat Kavitasi.................................................2
Gambar 5 Skema Alat Percobaan Pompa Sentrifugal...................................................2
Gambar 6 Diagram Alir Percobaan Centrifugal Pump.................................................2
Gambar 7 Perbandingan antara nilai NPSHA terhadap flowrate dengan variabel (+)
full suction-full discharge dan (-) full suction-full discharge........................................2
Gambar 8 Perbandingan antara nilai NPSHA terhadap flowrate dengan variabel (+)
half suction-full discharge dan (-) half suction-full discharge......................................2
Gambar 9 Perbandingan antara nilai NPSHA terhadap flowrate dengan variabel (+)
full suction-half discharge dan (-) full suction-half discharge......................................2
Gambar 10 Perbandingan antara nilai NPSHA terhadap efisensi dengan variabel (+)
full suction-full discharge dan (-) full suction-full discharge........................................2
Gambar 11 Perbandingan antara nilai efisiensi terhadap flowrate dengan variabel (+)
half suction-full discharge dan (-) half suction-full discharge......................................2
Gambar 12 Perbandingan antara nilai efisiensi terhadap flowrate dengan variabel (+)
full suction-half discharge dan (-) full suction-half discharge......................................2
Gambar 13 Perbandingan antara nilai head terhadap flowrate dengan variabel (+) full
suction-full discharge dan (-) full suction-full discharge..............................................2
Gambar 14 Perbandingan antara nilai Head terhadap flowrate dengan variabel (+)
half suction-full discharge dan (-) half suction-full discharge......................................2
Gambar 15 Perbandingan antara nilai Head terhadap flowrate dengan variabel (+) full
suction-half discharge dan (-) full suction-half discharge............................................2

DAFTAR TABEL

Tabel 1 Hasil Data Positive Suction, Full Open Suction-Full Open Discharge............2

ii
Tabel 2 Hasil Data Positive Suction, Half Open Suction-Full Open Discharge...........2
Tabel 3 Hasil Data Positive Suction, Full Open Suction-Half Open Discharge...........2
Tabel 4 Hasil Data Negative Suction, Full Open Sucion-Full Open Discharge...........2
Tabel 5 Hasil Data Negative Suction, Half Open Suction-Full Open Discharge..........2
Tabel 6 Hasil Data Negative Suction, Full Open Suction-Half Open Discharge..........2
Tabel 7 Hasil Data Perhitungan Positive Suction, Full Open Suction-Full Open
Discharge.......................................................................................................................2
Tabel 8 Hasil Data Perhitungan Positive Suction, Half Open Suction-Full Open
Discharge.......................................................................................................................2
Tabel 9 Hasil Data Perhitungan Positive Suction, Full Open Suction-Half Open
Discharge.......................................................................................................................2
Tabel 10 Hasil Data Perhitungan Negative Suction, Full Open Sucion-Full Open
Discharge.......................................................................................................................2
Tabel 11 Hasil Data Perhitungan Negative Suction, Half Open Suction-Full Open
Discharge.......................................................................................................................2
Tabel 12 Hasil Data Perhitungan Negative Suction, Full Open Suction-Half Open
Discharge.......................................................................................................................2

DAFTAR NOTASI

Notasi Keterangan Satuan


2
A luas area m
BHP break horsepower kW
D diameter M

iii
Ff frictional loss J/kg
g percepatan gravitasi m/s2
H head system M
Hsytem Head yang terdapat pada system M
H Pump Head yang terdapat pada pompa M
HT head total M
NPSH net positive suction head M
NPSHA net positive suction head available M
NPSHR net positive suction head required M
NRe Reynold Number dimensionless
P tekanan Pa
Ps tekanan suction Bar
Pd tekanan discharge Bar
Pvap tekanan uap Pa
Q flowrate m3/s
T waktu S
WHP work horsepower Watt
WS mechanical shaft work J/kg
WP shaft work delivered to pump J/kg
v kecepatan m/s
Z ketinggian M
Α correction factor, aliran turbulen = 1 dimensionless
ϵ relative roughness M
Η efisiensi dimensionless
Ρ massa jenis kg/m3

Notasi Keterangan Satuan


Μ viskositas kg/m.s
V Volume m3
P perbedaan tekanan Pa
HC consentration loss at tank exit J/Kg
F Friction factor dimensionless
KC, Kf contraction, fitting loss cefficient dimensionless

iv
BAB I
PENDAHULUAN

1.1 Tujuan Percobaan


Tujuan dari praktikum pompa sentrifugal ini adalah praktikan mampu
mengaplikasikan konsep transportasi fluida incompressible dengan menggunakan
pompa sentrifugal (centrifugal pump).

1.2 Dasar Teori


1.2.1 Definisi Pompa
Pompa merupakan alat yang digunakan untuk memindahkan suatu cairan dari
suatu tempat ke tempat lain dengan cara menaikkan tekanan cairan tersebut.
Kenaikan tekanan cairan tersebut digunakan untuk mengatasi hambatan-hambatan
pengaliran. Hambatan-hambatan pengaliran itu dapat berupa perbedaan tekanan,
perbedaan ketinggian atau hambatan gesek (Nugroho, 2014).
1.2.2 Klasifikasi pompa
Klasifikasi pompa secara umum dapat diklasifikasikan menjadi 2 bagian yaitu
pompa kerja positif (positive displacement pump) dan pompa kerja dinamis.
1. Pompa Pemindah Positif (Positive Displacement Pump)
Pompa jenis ini merupakan pompa dengan ruangan kerja yang secara periodik
berubah dari besar ke kecil atau sebaliknya, selama pompa bekerja. Energi
yang diberikan kepada cairan ialah energi potensial, sehingga cairan
berpindah volume per volume. Berikut termasuk dalam kelompok pompa
pemindah positif antara lain:
a. Pompa reciprocating seperti pompa torak, pompa plunger
b. Pompa rotari seperti pompa screw dan pompa roda gigi
2. Pompa kerja dinamis
Pompa jenis ini adalah suatu pompa dengan volume ruang yang tidak berubah
pada saat pompa bekerja. Energi yang diberikan pada cairan adalah enersi
kecepatan, sehingga cairan berpindah karena adanya perubahan energi

1
kecepatan yang kemudian dirubah menjadi energi dinamis di dalam rumah
pompa itu sendiri. Berikut yang termasuk dalam kelompok pompa kerja
dinamis antara lain:
a. Pompa kerja khusus seperti pompa jet, pompa hydrant, dan pompa
elektromagnetik
b. Pompa sentrifugal (centrifugal pump)
(Nugroho, 2014)
Salah satu jenis pompa kerja dinamis adalah pompa sentrifugal yang prinsip
kerjanya mengubah energi kinetik (kecepatan) cairan menjadi energi potensial
melalui suatu impeller yang berputar dalam casing. Gaya sentrifugal yang timbul
karena adanya gerakan sebuah benda atau partikel melalui lintasan lengkung
(melingkar). Pompa sentrifugal merupakan pompa kerja dinamis yang paling banyak
digunakan karena mempunyai bentuk yang sederhana dan harga yang relatif murah.
(Nugroho, 2014).
1.2.3 Komponen Pompa Sentrifugal

Gambar 1 Komponen Pompa Sentrifugal (Tampak Samping)

2
Gambar 2 Komponen Pompa Sentrifugal (Tampak Depan)
(McCabe,1993)
Berikut merupakan komponen utama dalam centrifugal pump:
a. Shaft (poros)
Shaft (poros) berfungsi untuk meneruskan momen puntir dari penggerak selama
beroperasi dan tempat kedudukan impeller serta bagian – bagian berputar lainnya.
b. Vane
Vane atau sudu dari impeller sebagai tempat berlalunya cairan pada impeller.
c. Casing
Casing merupakan bagian paling luar dari pompa yang berfungsi sebagai
pelindung elemen yang berputar, tempat kedudukan diffuser (guide vane), inlet
dan outlet nozzel serta tempat memberikan arah aliran dari impeller dan
mengkonversikan energi kecepatan cairan menjadi energi dinamis.
d. Eye of Impeller
Eye of Impeller merupakan bagian sisi masuk pada arah isap impeller.
e. Impeller
Impeller berfungsi untuk mengubah energi mekanis dari pompa menjadi energi
kecepatan pada cairan yang dipompakan secara kontinyu, sehingga cairan pada sisi
isap secara terus menerus akan masuk mengisi kekosongan akibat perpindahan
dari cairan yang masuk sebelumnya.
f. Suction dan Discharge Nozzlesuction
Suction dan Discharge Nozzlesuction adalah bagian dimana fluida dapat masuk ke

3
pompa. Discharge Nozzle berfungsi untuk mengeluarkan cairan dari impeller. Di
dalam nozzel ini sebagian head kecepatan aliran diubah menjadi head tekanan.
(Nugroho, 2014).
1.2.4 Parameter Kinerja Centrifugal Pump
Adapun parameter kinerja pada pompa sentrifugal antara lain:
1. Head
Head pompa adalah energi per satuan berat yang harus disediakan untuk
mengalirkan sejumlah zat cair yang direncanakan sesuai kondisi instalasi pompa
atau tekanan untuk mengalirkan sejumlah zat cair, yang umumnya dinyatakan
dalam satuan ketinggian. Head total pompa dapat ditentukan dari persamaan
berikut.
HT = Hs + Hp+ Hf + Hv ..............................................(1)
(Geankoplis,2003)
Hs adalah head statis pompa (m), Hp adalah head pressure, Hf adalah head friksi
pada sistem perpipaan, dan Hv adalah velocity head. Jika persamaan (1)
dijabarkan, maka akan menjadi:
∆P ∑F 1
HT = ∆Z + + + ∆𝑣2 .......................(2)
ρg g 2g
(Geankoplis,2003)
∑F adalah total friction loss baik dalam pipa lurus (Ff), kontraksi (hc), ekspansi
(hex), valve, dan fitting (hf).
∑F = Ff + hex + hc + hf ..............................................(3)
(Geankoplis,2003)
∆ L v ❑2 v2 v2 v2
∑F = 4.𝑓. . + Kex. 1 + Kc. 2 + Kf. 1 ...(4)
D 2α 2 2 2
(Geankoplis, 2003)
2. Net Positive Suction Head (NPSH)
NPSH adalah kerja yang dibutuhkan pompa untuk menghisap fluida dari sumber
hingga impeller. Terdapat 2 macam NPSH, yaitu (NPSH)A (available) dan
(NPSH)R (required). (NPSH)R dapat diketahui dari spesifikasi pompa, sedangkan

4
(NPSH)A dapat dihitung melalui rumus berikut.
P1 P vp v2 F
(NPSH)A = - + z1 - - ........................(5)
ρg ρg 2g 2g
(Geankoplis,2003)

3. Efisiensi Pompa (Pump Efficiency)


Efisiensi pompa dapat mempengaruhi kerja pompa terhadap fluida (Ws), dan
juga melibatkan kerja shaft (Wp) atau seberapa besar energi yang dikonversikan
dari listrik menjadi kinetik oleh shaft pompa.
WP = - WS η .............................................................(6)
(Geankoplis, 2003)

WHP
%η=- 𝑥 100% ..............................................(7)
BHP
(Geankoplis,2003)
4. Pump Capacity
Pump Capacity merupakan jumlah flowrate yang dapat dihasilkan pompa.
Beberapa hal yang menentukan pump capacity adalah ukuran impeller, kecepatan
perputaran impeller, ukuran pompa, tekanan, temperature, dan jenis fluida
(Geankoplis,2003).
5. Pump Characteristic Curve
Kurva karakteristik pompa yang paling umum adalah pada pompa sentrifugal.
Karakteristik dari pompa sentrifugal merupakan hubungan antara tekanan yang
dibangkitkan (head) dan kecepatan aliran volume (kapasitas). Karakteristik dapat
juga menyertakan kurva efisiensi dan harga Brake Horse power-nya.
Karakteristik pompa berbeda-beda berdasarkan pada jenis pompa, putaran
spesifik, dan pabrik pembuatnya (Nugroho, 2014).
Kurva karakteristik pompa sentrifugal daapt dilihat pada gambar di bawah.
Berikut kurva karakteristik untuk pompa sentrifugal (Geankopis,2003).

5
Gambar 3 Kurva Krakteristik Pompa Sentrifugal
(Geankoplis,2003)
1.2.5 Kavitasi pada Pompa
Dalam kerjanya, pompa dapat mengalami kavitasi. Kavitasi merupakan
peristiwa terbentuknya gelembung-gelembung uap di dalam fluida yang dipompa
akibat turunnya tekanan fluida sampai di bawah tekanan uap jenuhnya pada suhu
operasi pompa. Gelembung uap yang terbentuk dalam proses ini mempunyai siklus
yang sangat singkat. Gelembung ini akan terbawa aliran fluida sampai akhirnya
berada pada daerah yang mempunyai tekanan lebih besar daripada tekanan uap jenuh
fluida. Pada daerah itu, gelembung akan pecah dan menyebabkan benturan atau
tumbukan pada dinding di dekatnya. Cairan akan masuk secara tiba-tiba ke ruangan
yang terbentuk akibat pecahnya gelembung uap tadi sehingga mengakibatkan
tumbukan.
Peristiwa ini akan menyebabkan terjadinya kerusakan mekanis pada pompa
(Sigit, 2014). Salah satu indikasi terjadinya penurunan performa pompa adalah
melalui fenomena kavitasi. Kavitasi dapat diketahui dari adanya getaran yang tinggi
pada pompa dan adanya suara bising. Getaran tersebut terjadi karena peristiwa
tumbukan gelembung pada impeller yang menyebabkan gelembung tersebut pecah.
(Siregar, 2012)

6
Gambar 4 Contoh Kerusakan yang diakibatkan oleh Kavitasi
(Nugroho,2014)

7
BAB II
METODOLOGI PERCOBAAN

2.1 Alat dan Bahan


Adapun alat dan bahan yang digunakan dalam praktikum pompa sentrifugal ini
yaitu:
1. Satu Set Alat Pompa Sentrifugal
2. Gelas ukur 500 mL 1 buah
3. Air
4. Stopwatch 1 buah
5. Beaker Glass 600 mL
6. Termometer
2.2 Skema Alat Percobaan
Sketsa alat percobaan yang digunakan pada praktikum pompa sentrifugal ini ad
alah sebagai berikut

Gambar 4 Skema Alat Percobaan Pompa Sentrifugal

8
2.3 Variabel Percobaan
Variabel percobaan pada praktikum sentrifugal antara lain:
a. Posisi suction: Positive suction dan negative suction
b. Tekanan suction: Fully open dan half open
c. Tekanan discharge: Fully open dan half open
2.4 Cara Kerja
Adapun cara kerja dalam praktikum Pompa Sentrifugal ini antara lain:
1. Melakukan persiapan kerja tim.
2. Mempersiapkan alat eksperimen.
3. Melakukan Startup pompa air (bukaan valve 100%).
4. Mengukur flowrate air dengan menggunakan gelas ukur di setiap variabel
tekanan dan posisi suction.
5. Mencatat data yang diperlukan guna menyelesaikan tugas yang diberikan.
6. Melakukan Shut down pompa air.
7. Menyusun kembali alat eksperimen.

2.5 Diagram Alir Percobaan

Mulai

Positive Suction & Negative


Suction

Melakukan Startup pompa air (bukaan valve 100%).

9
A

Mengukur flowrate air dengan menggunakan gelas


ukur di setiap variabel tekanan dan posisi suction.

Mencatat data yang diperlukan guna menyelesaikan


tugas yang diberikan.

Melakukan Shut down pompa air.

Volume, Waktu, Flowrate

Selesai

Gambar 5 Diagram Alir Percobaan Centrifugal Pump

10
BAB III
HASIL DATA DAN PEMBAHASAN
3.1 Hasil Data
Berikut adalah hasil data dari praktikum pompa sentrifugal:

Tabel 1 Hasil Data Positive Suction, Full Open Suction-Full Open Discharge
No V (m3) t (s) Q (m3/s) Ps PD
1 0.00045 1.01 0.0004455
2 0.00048 1.12 0.0004286
3 0.000395 0.9 0.0004389 0.04 0
4 0.00044 1 0.0004400
5 0.00037 0.85 0.0004353

Tabel 2 Hasil Data Positive Suction, Half Open Suction-Full Open Discharge
No V (m3) t (s) Q (m3/s) Ps PD
1 0.000385 1.04 0.0003702
2 0.000365 1.03 0.0003544
3 0.000325 0.9 0.0003611 0.3 0
4 0.000455 1.24 0.0003669
5 0.000385 1.05 0.0003667

Tabel 3 Hasil Data Positive Suction, Full Open Suction-Half Open Discharge

No V (m3) t (s) Q (m3/s) Ps PD


1 0.000325 1.02 0.0003186
2 0.00036 1.17 0.0003077
3 0.00034 1.11 0.0003063 0 1.4
4 0.00038 1.22 0.0003115
5 0.000415 1.32 0.0003144

Tabel 4 Hasil Data Negative Suction, Full Open Sucion-Full Open Discharge

No V (m3) t (s) Q (m3/s) Ps PD


1 0.00034 1.32 0.0002576

11
2 0.000355 1.37 0.0002591
3 0.00032 1.26 0.0002540 0.18 0
4 0.00036 1.42 0.0002535
5 0.00038 1.53 0.0002484

Tabel 5 Hasil Data Negative Suction, Half Open Suction-Full Open Discharge

No V (m3) t (s) Q (m3/s) Ps PD


1 0.000345 1.06 0.0003255
2 0.000365 1.01 0.0003614
3 0.000345 1.09 0.0003165 0.5 0
4 0.000285 0.82 0.0003476
5 0.000435 1.37 0.0003175

Tabel 6 Hasil Data Negative Suction, Full Open Suction-Half Open Discharge

No V (m3) t (s) Q (m3/s) Ps PD


1 0.000495 1.03 0.0004806
2 0.000445 0.91 0.0004890
3 0.000375 0.79 0.0004747 0.16 1.4
4 0.000495 1.07 0.0004626
5 0.000495 1.05 0.0004714

3.2 Pembahasan
Positive Suction adalah keadaan saat suction berada diatas pompa. Sedangkan
negative suction adalah keadaan dimana suction berada dibawah pompa.
1. Flowrate Terhadap NPSHA
Pada grafik dibawah membahas mengenai hubungan antara Net Positive
Suction Head Available dan debit alir. NPSHA sendiri merupakan kebutuhan
minimum pompa untuk bekerja secara normal. Lalu Q adalah jumlah air yang
mengalir dalam satuan volume per waktu.

a. Full Suction-Full Discharge

12
Gambar 6 Grafik NPSHA terhadap Flowrate dengan Variabel (+) Full Suction-
Full Discharge dan (-) Full Suction-Full Discharge

NPSH vs Q
10.2
10
NPSH (m)

9.8 (+)half suction-full discharge


9.6 (-)half suction-full discharge
9.4
9.2
4 4 4 4 4 4 4 4
1 E- 2 E- 3 E- 4 E- 5 E- 6 E- 7 E- 8 E-
3. 3. 3. 3. Q (m3/s) 3. 3. 3. 3.

b. Half Suction-Full Discharge

Gambar 7 Grafik NPSHA terhadap Flowrate dengan Variabel (+) Half Suction-
Full Discharge dan (-) Half Suction-Full Discharge
c. Full suction-half discharge

13
NPSH vs Q
10.4
10.2
10
9.8
NPSH (m)

9.6 (+) full suction - half discharge


9.4 (-) full suction - half discharge
9.2
9
8.8
3.0E-4 3.3E-4 3.6E-4 3.9E-4 4.2E-4 4.5E-4 4.8E-4 5.1E-4
Q(m3/s)

Gambar 8 Grafik NPSHA terhadap Flowrate dengan Variabel (+) Full


Suction-Half Discharge dan (-) Full Suction-Half Discharge
Pada gambar 7 dapat diketahui nilai NPSHA saat positive suction full dan
discharge full lebih besar daripada nilai NPSHA saat negative suction full dan
discharge full. Hal ini dikarenakan pompa tidak lagi memerlukan energy untuk
menghisap fluida.Hal itu disebabkan oleh besarnya nilai Head Loss yang terdapat
pada pompa Nilai Q sebanding dengan NPSH A dikarenakan tidak ada pressure
drop dalam aliran.
Pada gambar 8 dapat diketahui nilai NPSH A saat positive suction half dan
discharge full lebih besar daripada nilai NPSHA saat negative suction half dan
discharge full. Nilai Q lebih besar daripada NPSH A karena adanya pengaruh
pressure drop dalam aliran. Nilai NPSHA merupakan parameter terjadinya
kavitasi. Maka saat nilai NPSHA kecil, akan menimbulkan kavitasi pada pompa.
Untuk menghindari kavitasi, nilai NPSHA harus lebih besar dibanding nilai
NPSHR sehingga bagian yang nilai friksinya kecil akan terhindar dari kavitasi.
Pada gambar 9 dapat diketahui nilai Q yang digunakan lebih besar karena adanya
pengaruh pressure drop. Jika pressure drop nya besar maka nilai laju alirnya
juga besar. Seperti hal nya jika selang pada bagian ujung selang di tekan maka
laju alirnya nya akan semakin besar

14
3.2.2 Flowrate terhadap efisensi
Pada grafik dibawah membahas mengenai hubungan antara Debit alir fluida dan
Efisiensi pompa. Efisiensi pompa adalah perbandingan daya yang diberikan
pompa kepada fluida dengan daya yang diberikan motor listrik kepada pompa.

Efisiensi vs Q
0.7
0.6
0.5
Efisiensi

0.4 (+) full suction - full discharge


0.3 (-)full suction - full discharge
0.2
0.1
0
2.0E-4 2.5E-4 3.0E-4 3.5E-4 4.0E-4 4.5E-4 5.0E-4
Q (m3/s)

a. Full Suction- Full Discharge


Gambar 9 Grafik NPSHA terhadap Efisensi dengan Variabel (+) Full
Suction-Full Discharge dan (-) Full Suction-Full Discharge

b.
Efisiensi vs Q b.
0.56 b.
0.54 b.
0.52 b.
Efisiensi

0.5 (+) half suction - full discharge


b.
(-) half suction - full discharge
0.48 b.
0.46
b.
0.44
3.1E-43.2E-43.3E-43.4E-43.5E-43.6E-43.7E-43.8E-4 b.
Q (m3/s) b.
b.
b.

Gambar 10 Grafik Efisiensi terhadap Flowrate dengan Variabel (+) Half


Suction-Full Discharge dan (-) Half Suction-Full Discharge
Half Suction Dan Full Discharge

15
Efisiensi vs Q
0.8

0.6

Efisiensi
0.4 (+) full suction - half discharge
(-) full suction - half discharge
0.2

0
3.0E-4 3.3E-4 3.6E-4 3.9E-4 4.2E-4 4.5E-4 4.8E-4 5.1E-4
Q (m3/s)

c. Full Suction-Half Discharge

Ketiga grafik diatas menunjukkan persen efisensi berbanding lurus dengan


debit alirnya. Semakin besar debit alir, maka persen efiensi juga akan semakin
besar. Sama halnya dengan persen efisensi. sesuai dengan rumus teoritis pada
persamaan (7) yaitu persen efisensi berbanding lurus dengan WP (Shaft

Gambar 11 Grafik Efisiensi terhadap Flowrate dengan Variabel (+) Full


Suction-Half Discharge dan (-) Full Suction-Half Discharge

Work). Hal tersebut menunjukkan bahwa semakin besar debit aliran maka
persen efisensi juga akan semakin besar.
3.2.3. Flowrate terhadap Head
Pada grafik dibawah membahas mengenai hubungan antara Head dan Debit
aliran. Head pada pompa merupakan energi persatuan berat yang harus
disediakan untuk mengalirkan sejumlah zat cair yang direncanakan sesuai
kondisi instalasi pompa atau tekanan untuk mengalirkan sejumlah zat cair,
yang umumnya dinyatakan dalam satuan panjang.

16
Head vs Q
20
19.8
19.6
19.4
Head (m)

19.2
(+) full suction - full discharge
19 (-) full suction - full discharge
18.8
18.6
18.4
18.2
2.0E-4 2.5E-4 3.0E-4 3.5E-4 4.0E-4 4.5E-4 5.0E-4

Q (m3/s)

a. Full Suction-Full Discharge

Gambar 12 Perbandingan antara nilai head terhadap flowrate dengan variabel


(+) full suction-full discharge dan (-) full suction-full discharge

Head vs Q
19.6
19.5
19.4
19.3
Head (m)

(+) half suction - full


19.2 discharge
19.1 (-) half suction - full
discharge
19
18.9
18.8
3.1E-4 3.2E-4 3.3E-4 3.4E-4 3.5E-4 3.6E-4 3.7E-4 3.8E-4

Q (m3/s)

b. Half suction-full discharge

Gambar 13 Grafik Head terhadap flowrate dengan Variabel (+) Half Suction-
Full Discharge dan (-) Half Suction Full Discharge

17
c.
Head vs Q c.
19.8 c.
19.7 c.
19.6
c.
19.5
Head (m)

19.4 (+) full suction - half suction c.


19.3 (-) full suction - half discharge c.
19.2 c.
19.1
c.
19
-4 -4 -4 -4 -4 -4 -4 -4 c.
0E 3E 6E 9E 2E 5E 8E 1E
3. 3. 3. 3. Q (m3/s)
4. 4. 4. 5. c.
c.
Full Suction-Half Discharge

Gambar 14 Grafik Head terhadap Flowrate dengan Variabel (+) Full Suction-
Half Discharge dan (-) Full Suction-Half Discharge

Dari ketiga grafik diatas dapat disimpulkan bahwa semakin besar nilai head
maka semakin kecil debit alir yang dihasilkan. Hal ini membuktikan apabila
valve dibuka dengan bukaan besar maka kecepatan alirannya akan semakin
rendah. Contoh sederhana ialah saat selang air yang tidak ditutup setengah maka
debitnya akan lebih kecil daripada yang ditutup setengah. Namun head
merupakan kerugian yang timbul selama pompa berjalan, hal ini diperoleh karena
adanya sambungan dan gesekan didalam pipa atau gesekan didalam pompa itu
sendiri yang tidak mengubah energi menjadi kerja sepenuhnya. Head negative
lebih besar dibandingkan head positive dikarenakan head dari pompa berbanding
terbalik dengan head system sedangkan head system berbanding lurus dengan
Ws. Karena Ws dari negative suction lebih kecil, maka head systemnya lebih
kecil dan head pumpnya lebih besar dibandingkan positif suction.

18
BAB IV
KESIMPULAN DAN SARAN

4.1 Kesimpulan
Kesimpulan dan hasil eksperimen centrifugal pump adalah sebagai berikut:
1. Praktikan dapat memahami konsep fluida incompressible dengan
menggunakan pompa sentrifugal.
2. Kinerja pompa sentrifugal dapat diketahui dari NPSHA, persen efisensi dan
Head.
3. Berdasarkan grafik dapat diketahui saat full suction-full discharge pada
grafik perbandingan NPSHA terhadap laju alir menyatakan bahwa nilai
NPSHA sebanding dengan nilai Q, karena tidak adanya pengaruh pressure
drop. Kemudian saat keadaan half-suction dan full-discharge serta full
suction-half discharge dapat dilihat pada grafik bahwa nilai Q nya lebih
besar daripada NPSHA, hal ini dikarenakan tidak ada pressure drop yang
bekerja dalam aliran.
4. Pada grafik perbandingan efisensi terhadap Q dapat diambil kesimpulan
bahwa saat keadaan full suction-full discharge, half suction-full discharge
dan full suction-half discharge menunjukkan persen efisensi berbanding
lurus dengan debit alirnya. Semakin besar debit alir maka, persen efiensi
juga akan semakin besar.
5. Pada grafik perbandingan head terhadap Q saat keadaan full suction-full
discharge, half suction-full discharge dan full suction-half discharge dapat
disimpulkan bahwa semakin besar nilai Head maka semakin kecil debit alir
yang dihasilkan.

4.2 Saran
Adapun saran untuk percobaan kali ini adalah:
1. Sebaiknya posisi pipa pada discharge lebih ditinggikan agar menampung air
yang keluar dengan beaker glass menjadi lebih mudah
2. Dalam mengukur volume air dengan gelas ukur harus lebih teliti lagi.

19
DAFTAR PUSTAKA

Geankoplis, Christie J. 2003. Transport Processes and Unit Operations, Fourth


Edition. New Jersey: Prentice-Hall, Inc.
McCabe, W.I. and Smith, J.C. 1993. Unit Operation of Chemical Engineering. 4th
Edition. McGraw Hill Book Company. Singapore
Nugroho, A. 2014. Dasar Teori Pompa. eprints.undip.ac.id
Siregar, Batara Guru Dewa. 2012. Studi Eksperimental Karakteristik Bubble Sebagai
Indikasi Awal Terjadinya Fenomena Kavitasi Dengan Menggunakan Sinyal
Vibrasi Pada Pompa Sentrifugal. Jurnal e-Dinamis, Volume 1, Nomor 1. Hal
22-32.

20
LAMPIRAN
I. Hasil Data Perhitungan
Tabel 7 Hasil Data Perhitungan Positive Suction, Full Open Suction-Full Open
Discharge

ΣF (J/Kg) H system H pump WHP Efisiensi


Q (m3/s) V (m/s) NPSH (m) Ws(J/Kg)
(m) (m) (Watt) (%)
0.0004455 0.908116289 2.825337 10.03210 1.15980715 18.84019285 11.37382 5.045653 65.5702
0.0004286 0.873521383 2.614173 10.05677 1.135131923 18.86486808 11.13184 4.750179 63.1549
0.0004389 0.894550602 2.741556 10.04189 1.150017055 18.84998295 11.27781 4.928324 64.6243
0.0004400 0.896815287 2.755455 10.04026 1.151641188 18.84835881 11.29374 4.947779 64.7823
0.0004353 0.887223679 2.696830 10.04711 1.14479064 18.85520936 11.22656 4.865744 64.1127

Tabel 8 Hasil Data Perhitungan Positive Suction, Half Open Suction-Full Open
Discharge

ΣF (J/Kg) H system Hpump WHP Efisiensi


Q (m3/s) V (m/s) NPSH (m) Ws(J/Kg)
(m) (m) (Watt) (%)
0.000370 0.754532 1.975533 10.13178 0.957717914 19.04228209 9.392002 3.461824 55.0651
0.000354 0.722280626 1.810269 10.15107 0.938436241 19.06156376 9.202911 3.247137 52.7648
0.000361 0.736022647 1.879808 10.14291 0.946548994 19.05345101 9.282477 3.337521 53.7458
0.000366 0.74789398 1.940926 10.13616 0.953680461 19.04631954 9.352418 3.416909 54.5922
0.000366 0.747346072 1.938086 10.13619 0.953348804 19.0466512 9.349152 3.413213 54.5532

Tabel 9 Hasil Data Perhitungan Positive Suction, Full Open Suction-Half Open
Discharge

ΣF (J/Kg) H system H pump WHP Efisiensi


Q (m3/s) V (m/s) NPSH (m) Ws(J/Kg)
(m) (m) (Watt) (%)
0.738851141 19.26114886
0.000318 0.64943177 1.509908 10.18679 7.245655 2.298698 47.9397
0.000307 0.627143557 1.408047 10.19861 0.727013621 19.27298638 7.129569 2.184239 46.3229
0.000306 0.624318586 1.395385 10.20007 0.725542762 19.27445724 7.115144 2.169998 46.1177
0.000311 0.634854339 1.442881 10.19459 0.731062143 19.26893786 7.169278 2.223406 46.8826
0.000314 0.640802934 1.470042 10.19149 0.73421924 19.26578076 7.200233 2.253921 47.3141
Tabel 10 Hasil Data Perhitungan Negative Suction, Full Open Sucion-Full Open
Discharge

ΣF (J/Kg) H system H pump WHP Efisiensi


Q (m3/s) V (m/s) NPSH (m) Ws(J/Kg)
(m) (m) (Watt) (%)

21
0.000257 0.524995175 1.0170375 9.6544918 0.132106964 19.86789304 1.2955267 0.332254 39.9748
0.000259 0.528151007 1.0293014 9.6530718 0.133526989 19.86647301 1.3095524 0.337844 40.2123
0.000254 0.517642301 0.9887486 9.6577674 0.128831417 19.87116858 1.2634046 0.319478 39.4215
0.000253 0.516730959 0.9852701 9.6581701 0.128428652 19.87157135 1.2594548 0.317919 39.3529
0.000248 0.506223721 0,9456084 9.6627625 0.123836267 19.87616373 1.2144189 0.300317 38.5616

Tabel 11 Hasil Data Perhitungan Negative Suction, Half Open Suction-Full Open
Discharge

ΣF (J/Kg) H system H pump WHP Efisiensi


Q (m3/s) V (m/s) NPSH (m) Ws(J/Kg)
(m) (m) (Watt) (%)
0.000325 0.663381 1.575470 9.589162 0.525161082 19.47483892 5.150070 1.668961 49.5128
0.000361 0.736583 1.942346 9.546526 0.567797048 19.43220295 5.568186 2.003572 54.8559
0.000316 0.645123 1.489940 9.599102 0.515221381 19.48477862 5.052595 1.592307 48.1746
0.000347 0.708404 1.796576 9.563467 0.550856625 19.44914337 5.402058 1.869433 52.8034
0.000317 0.647170 1.499412 9.598001 0.516322149 19.48367785 5.063390 1.600773 48.3248

Tabel 12 Hasil Data Perhitungan Negative Suction, Full Open Suction-Half Open
Discharge

ΣF (J/Kg) H system H pump WHP Efisiensi


Q (m3/s) V (m/s) NPSH (m) Ws(J/Kg)
(m) (m) (Watt) (%)
0.000480 0.9795312 3.413835 9.375219 0.354027667 19.64597233 3.471825 1.661290 73.7516
0.0004890 0.996710 3.534628 9.361170 0.368076175 19.63192383 3.609594 1.757505 74.9914
0.0004747 0.967507 3.330542 9.384906 0.344340578 19.65565942 3.376827 1.595999 72.8823
0.000462 0.942913 3.163365 9.404349 0.32489772 19.67510228 3.186158 1.467602 71.0998
0.000471 0.960873 3.285022 9.390200 0.339046602 19.6609534 3.324911 1.560686 72.4020

II. Appendiks Perhitungan

 Perhitungan Q (Flow Rate)


V
Q=
t
Dimana, Q = Flow rate (m3/s)
V = Volume (m3)

22
t = waktu (s)
0.0005 m 3
Q=
1.01 s
Q = 0.0004455 m3/s

 Perhitungan v (kecepatan)
Q
v=
A
Dimana, v = kecepatan (m/s)
Q = Flow rate (m3/s)
A = luas pipa
0.0004455m 3 / s
v=
0.0004906 m
v = 0.9081 m/s
 Perhitungan ∆ P (Perbedaan Tekanan)
∆ P=Pdischarge −PSuction
Dimana, ∆ P = Perbedaan Tekanan (Pa)
Pdischarge = Tekanan pada discharge (Pa)
Psuction = Tekanan pada suction (Pa)
∆ P=0 Pa−(−4000 Pa)
∆ P=4000 Pa

 Perhitungan hc (Contraction loss at tank exit)


A2 2 v 2
h c =0,55(1− )
A1 2 α
Dimana, hc = Contraction loss at tank exit (J/kg)
A2 = Cross-sectional area pipa (m2)
A1 = Cross-sectional area wadah (m2)

23
v = kecepatan (m/s)
α untuk turbulent flow = 1

Karena A1 sangat besar dibandingkan A2, maka A2/A1 = 0

2
m
h c =0,55(1−0)2
( 0.9081
s )
2× 1

h c =0.2268 J /Kg

 Perhitungan mencari NRE (Reynolds Number)


Dvρ
N ℜ=
μ
Dimana, NRE = Reynolds Number
D = diameter (m)
v = kecepatan (m/s)
ρ = massa jenis (kg/m3)
μ = viskositas (kg/ms)
m 995.68 kg
0.025 m× 0.9081 ×
s m3
N ℜ=
0,00081835 kg
m. s

N ℜ=28231

 Berdasarkan pada tabel di gambar 2.10-3 pada buku Geankoplis halaman 94,
diketahui Friction factor untuk pipa commercial steel ( ε=4,6× 10−5 ) dan ε /D =
0,00158621 serta NRE = 28231 adalah 0.0058

 Perhitungan Friction in the straight pipe (Ff)


∆ L v2
F f =4 f ×
D 2
Dimana, Ff = Friction loss (J/Kg)
F =Friction factor

24
∆L = Panjang pipa (m)
D = diameter (m)
v = kecepatan (m/s)
2
m
F f =4 × 0.0058×
2,75 m
×
( 0.9081
s )
0,025m 2
Ff = 1.0523 J/Kg

 Perhitungan hf (Friction in 5-in elbow)


v2
h f =5 K f
2
Dimana, hf = Friction in elbow (J/Kg)
Kf = Friction Loss Elbow
v = kecepatan (m/s)
Berdasarkan pada tabel 2.10-1 diketahui Friction Loss untuk Elbow 90°adalah 0,75
2
m
h f =5 × 0,75×
( 0.9801
s )
2
h f =1.5463 J / Kg

 Perhitungan ∑ F (Total Friction)

∑ F=hc + F f + hf
Dimana, ∑F = Total Friction (J/Kg)
hc = Contraction loss at tank exit (J/kg)
Ff = Friction loss (J/Kg)
hf = Friction in elbow (J/Kg)
J J J
∑ F=0.2268 Kg +1.0523 Kg +1.5463 Kg
∑ F=2.8253 J / Kg

 Perhitungan (NPSH)A (Net Positive Suction Head)

25
P P v2
( NPSH ) A =
ρ ( )(
ρ )
− vapor + ( g × z )−
2 ( )
−∑ F

Dimana, (NPSH)A = Net Positive Suction Head (m)


P = Tekanan di permukaan (Pa)
ρ = massa jenis (kg/m3)
Pvapor = Tekanan uap (Pa)
g = gravitasi (m/s2)
z = tinggi permukaan liquid terhadap pompa (m)
v = kecepatan (m/s)
2
m
101.325 Pa

(
995,68 kg

4246 Pa

)(
995,68 kg
+
9,80665 m

)(
s2
× ( 0.42 m) − () ( 0.9081

2
s ) ) −
2.8253 J
Kg
m3 m3
( NPSH ) A =
9,80665 m
s

( NPSH ) A =10.132m

 Perhitungan Ws (Mechanical Energy)


1 2 Pdischarge −P suction
−W s= v +( g × z)+ +∑ F
2α ρ

Dimana,

Ws = Mechanical Energy (J/Kg)

α untuk turbulent flow =1

v = kecepatan (m/s)
g = gravitasi (m/s2)
z = tinggi permukaan liquid terhadap pompa (m)
Pdischarge = Tekanan pada discharge (Pa)

26
Psuction = Tekanan pada suction (Pa)
ρ = massa jenis (kg/m3)
∑F = Total Friction (J/Kg)
1 m 2 9,80665 m 0 Pa−(−4000 Pa )
−W s=
2× 1 (
0.9081
s
+() s 2
×0.42 m)+
995.68 kg
+ 2.8253 J /Kg

m3
−W s=11.374 J /Kg
 Perhitungan H (Head System)
−W s
H=
g
Dimana, H = Head (m)

-Ws = Mechanical Energy (J/Kg)

g = gravitasi (m/s2)
11.374 J /Kg
H=
9,80665 m
s2
H = 1.1598 m
 Perhitungan Head Pump
Head Pump = Total Head – Head System

Dimana, Head pump (m)


Total head (m) diketahui pada pompa = 20 m
Head System (m)
Head Pump = 20 m – 1.1598 m
Head Pump = 18.84019 m

 Perhitungan WHP (Water Horsepower)


WHP= ρ× g × Q× H
Dimana, WHP = Water Horsepower (Watt)
ρ = massa jenis (kg/m3)
g = gravitasi (m/s2)

27
Q = Flow rate (m3/s)
H = Head (m)
995.68 kg 9,80665 m
WHP= 3
× 2
×0.0004455 m 3 /s × 18.84019 m
m s
WHP = 81.963 Watt

 Perhitungan η (Efisiensi)
WHP
η=
BHP

Dimana, η = Efisiensi
WHP = Water Horsepower (Watt)
BHP = Brake Horsepower (Watt)
81.963 Watt
η=
125 Watt
η=0.6557
η=65.57 %

28
III. Dokumentasi Percobaan

29