KATA PENGANTAR
Demikian Laporan ini disampaikan, terima kasih atas kepercayaan yang telah
diberikan kepada PT. Tatabumi Konsultan.
ii
FINAL LAPORAN ANTARA
DETAIL PRASARANA PENYEDIAAN AIR BAKU
DI KABUPATEN BANDUNG BARAT
DAFTAR ISI
Halaman
KATA PENGANTAR.....................................................................................................ii
DAFTAR ISI...................................................................................................................iii
DAFTAR TABEL...........................................................................................................vi
DAFTAR GAMBAR....................................................................................................viii
BAB I PENDAHULUAN.............................................................................................I-1
iii
FINAL LAPORAN ANTARA
DETAIL PRASARANA PENYEDIAAN AIR BAKU
DI KABUPATEN BANDUNG BARAT
4.1 Analisis Data....................................................................................................IV-1
4.1.1 Umum..........................................................................................................IV-1
6.1.1 Umum..........................................................................................................VI-1
6.2 Hidrolika.........................................................................................................VI-17
7.1 Umum.............................................................................................................VII-1
7.3 Sondir..............................................................................................................VII-2
iv
FINAL LAPORAN ANTARA
DETAIL PRASARANA PENYEDIAAN AIR BAKU
DI KABUPATEN BANDUNG BARAT
7.4 Hasil lapangan dan Laboratorium Geoteknik.................................................VII-3
v
FINAL LAPORAN ANTARA
DETAIL PRASARANA PENYEDIAAN AIR BAKU
DI KABUPATEN BANDUNG BARAT
DAFTAR TABEL
vi
FINAL LAPORAN ANTARA
DETAIL PRASARANA PENYEDIAAN AIR BAKU
DI KABUPATEN BANDUNG BARAT
Tabel VI-14 Hasil Perhitungan Kebutuhan Air Layanan Mata Air Suramanggala.....................VI-12
Tabel VI-15 Hasil Analisa Neraca Air.......................................................................................VI-13
Tabel VI-16 Hasil Analisa Hidrolis Pada Bangunan Air MA. Curug Goong.............................VI-19
Tabel VI-17 Hasil Analisa Hdrolis Pada Pipa Jaringan MA. Curug Goong..............................VI-19
Tabel VI-18 Hasil Analisa Hdrolis Pada Bangunan Air MA. Saguling......................................VI-21
Tabel VI-19 Hasil Analisa Hdrolis Pada Pipa Jaringan MA. Saguling......................................VI-21
Tabel VI-20 Hasil Analisa Hidrolis Pada Bangunan Air MA. Suramanggala............................VI-23
Tabel VI-21 Hasil Analisa Hdrolis Pada Pipa Jaringan MA. Suramanggala..............................VI-23
Tabel VII-1 Cone Penetration Test Curug Goong......................................................................VII-6
Tabel VII-2 Cone Penetration Test Suramanggala......................................................................VII-8
Tabel VII-3 Resume Tespit Curug Goong................................................................................VII-12
Tabel VII-4 Resume Tespit Suramanggala...............................................................................VII-12
Tabel VII-5 Resume Tespit Saguling........................................................................................VII-12
Tabel VII-6 Resume Hasil Handbor Curug Goong...................................................................VII-13
Tabel VII-7 Resume Hasil Handbor Suramanggala..................................................................VII-13
Tabel VII-8 Resume Hasil Handbor Saguling..........................................................................VII-13
vii
FINAL LAPORAN ANTARA
DETAIL PRASARANA PENYEDIAAN AIR BAKU
DI KABUPATEN BANDUNG BARAT
DAFTAR GAMBAR
Gambar II-1 Peta Orientasi Kabupaten Bandung Barat dalam wilayah Provinsi Jawa Barat.......II-1
Gambar III-1 Hasil Kontur Pengukuran Topografi Pada Jaringan Distibusi di MA. Curug
Goong..........................................................................................................................................III-3
Gambar III-2 Hasil Kontur Pengukuran Topografi Pada Jaringan Distibusi di MA. Saguling....III-4
Gambar III-3 Hasil Kontur Pengukuran Topografi Pada Jaringan Distibusi di MA. Suramanggala
.....................................................................................................................................................III-5
Gambar III-4 Kegiatan Pengecekan Alat untuk Survey Topografi Bersama Direksi....................III-6
Gambar III-5 Pelaksanaan Survey Topografi di MA. Curug Goong, Desa Cinengah, Kec. Rongga
.....................................................................................................................................................III-6
Gambar III-6 Pelaksanaan Survey Topografi di MA. Suramanggala, Desa Baranangsiang, Kec.
Cipongkor....................................................................................................................................III-6
Gambar III-7 Pelaksanaan Survey Topografi di MA. Saguling, Desa Baranangsiang, Kec.
Cipongkor....................................................................................................................................III-6
Gambar III-8 Pelaksanaan Survey Sosial Ekonomi dan Lingkungan - Pembagian dan Pengisian
Kuesioner.....................................................................................................................................III-9
Gambar IV-1 Usia Responden Penduduk di Desa Baranangsiang dan Desa Cinengah................IV-3
Gambar IV-2 Jenis Kelamin Responden di Desa Baranangsiang dan Desa Cinengah.................IV-4
Gambar IV-3 Status Kependudukan Responden Penduduk di Desa Baranangsiang dan Desa
Cinengah......................................................................................................................................IV-4
Gambar IV-4 Tingkat Pendidikan Responden di Desa Barangsiang dan Desa Cinengah............IV-5
Gambar IV-5 Mata Pencarian Responden di Desa Baranangsiang dan Desa Cinengah...............IV-5
Gambar IV-6 Jenis Lahan yang Dimiliki Penduduk Desa Baranangsiang dan Desa Cinengah....IV-6
Gambar IV-7 Status Kepemilikan Lahan di Desa Baranangsiang dan Desa Cinengah................IV-6
Gambar IV-8 Harga Nilai Lahan yang Dimiliki Penduduk Desa Baranangsiang dan Desa Cinengah
.....................................................................................................................................................IV-7
Gambar IV-9 Kondisi Kepemilikan Lahan di Desa Barangsiang dan Desa Cinengah.................IV-7
Gambar IV-10 Kondisi Penggunaan Listrik pada Lahan di Desa Baranangsiang dan Desa Cinengah
.....................................................................................................................................................IV-7
Gambar IV-11 Jumlah Kendaraan yang Dimiliki Penduduk Desa Baranangsiang dan Desa
Cinengah......................................................................................................................................IV-8
Gambar IV-12 Penghasilan/Bulan Penduduk Desa Baranangsiang dan Desa Cinengah..............IV-8
Gambar IV-13 Pengeluaran /Bln Penduduk Desa Baranangsiang dan Desa Cinengah................IV-9
Gambar IV-14 Kondisi Menabung Penduduk Desa Baranangsiang dan Desa Cinengah.............IV-9
viii
FINAL LAPORAN ANTARA
DETAIL PRASARANA PENYEDIAAN AIR BAKU
DI KABUPATEN BANDUNG BARAT
Gambar IV-15 Kesehatan / Penyakit yang Pernah Diderita Masyarakt Desa Baranangsiang dan
Desa Cinengah...........................................................................................................................IV-10
Gambar IV-16 Kondisi Fasilitas Sumber Air untuk Konsumsi di Desa Baranangsiang dan Desa
Cinengah....................................................................................................................................IV-11
Gambar IV-17 Kondisi Sumber Air untuk Mencuci di Desa Baranangsiang dan Desa
Cinengah....................................................................................................................................IV-12
Gambar IV-18 Kondisi Ketersediaan Air di Desa Baranangsiang dan Desa Cinengah..............IV-12
Gambar IV-19 Kualitas Air di Desa Baranangsiang dan Desa Cinengah...................................IV-12
Gambar IV-20 Ketersediaan Fasilitas Sanitasi di Desa Baranangsiang dan Desa Cinengah......IV-13
Gambar IV-21 Ketersediaan Fasilitas Drainase di Desa Baranangsiang dan Desa Cinengah.....IV-13
Gambar IV-22 Ketersediaan Saluran Langsung Ke Rumah Desa Baranangsiang dan Desa Cinengah
...................................................................................................................................................IV-14
Gambar IV-23 Ketersediaan Sumber Air Komunal Desa Baranangsiang dan Desa Cinengah...IV-14
Gambar IV-24 Harapan Terhadap Sumber Air Baru di Desa Baranangsiang dan Desa
Cinengah....................................................................................................................................IV-14
Gambar IV-25 Sumber Air yang Diharapkan Desa Baranangsiang dan Desa Cinengah............IV-15
Gambar IV-26 Kekeringan di Desa Baranangsiang dan Desa Cinengah....................................IV-15
Gambar IV-27 Tindak Darurat Penanganan Kekeringan di Desa Baranangsiang dan Desa Cinengah
...................................................................................................................................................IV-15
Gambar IV-28 Upaya Aparat Desa Untuk Memenuhi Kebutuhan Air Desa Baranangsiang dan Desa
Cinengah....................................................................................................................................IV-16
Gambar IV-29 Kesediaan Masyarakat Terhadap Pembangunan di Desa Baranangsiang dan Desa
Cinengah....................................................................................................................................IV-16
Gambar IV-30 Sistem Ganti Rugi yang Diharapkan Msyarakat Desa Baranangsiang dan Desa
Cinengah....................................................................................................................................IV-17
Gambar VI-1 Grafik Fluktuasi Pemakaian Air Bersih...............................................................VI-10
Gambar VI-2 Diagram Neraca Air MA. Curug Goong..............................................................VI-14
Gambar VI-3 Diagram Neraca Air MA. Saguling.....................................................................VI-15
Gambar VI-4 Diagram Neraca Air MA. Suramanggala.............................................................VI-16
Gambar VI-5 Skema Jaringan Transmisi MA. Curug Goong....................................................VI-18
Gambar VI-6 Potongan melintang dan memanjang Curug Goong.............................................VI-18
Gambar VI-7 Hasil Pemodelan Epanet MA. Curug Goong.......................................................VI-19
Gambar VI-8 Skema Jaringan Transmisi MA. Saguling............................................................VI-20
Gambar VI-9 Potongan melintang dan memanjang MA. Saguling............................................VI-20
Gambar VI-10 Hasil Pemodelan Epanet MA. Saguling.............................................................VI-21
Gambar VI-11 Skema Jaringan Transmisi MA. Suramanggala.................................................VI-22
ix
FINAL LAPORAN ANTARA
DETAIL PRASARANA PENYEDIAAN AIR BAKU
DI KABUPATEN BANDUNG BARAT
Gambar VI-12 Potongan melintang dan memanjang MA. Saguling..........................................VI-22
Gambar VI-13 Hasil Pemodelan Epanet MA. Suramanggala...................................................VI-23
Gambar VII-1 Lokasi Survey Geoteknik Curug Goong Desa Cinengah Kecamatan Rongga.....VII-3
Gambar VII-2 Lokasi Survey Geoteknik MA. Suramanggala Desa Cinengah Kecamatan Rongga
....................................................................................................................................................VII-4
Gambar VII-3 Lokasi Survey Geoteknik Mata air Saguling Desa Cinengah Kecamatan
Rongga.......................................................................................................................................VII-5
Gambar VII-4 Cone penetration Test Curug Goong...................................................................VII-7
Gambar VII-5 Grafik Cone Petetration Tes Suramangga...........................................................VII-9
Gambar VII-6 Grafik Cone Penetration Test saguling..............................................................VII-11
x
FINAL LAPORAN ANTARA
DETAIL PRASARANA PENYEDIAAN AIR BAKU
DI KABUPATEN BANDUNG BARAT
A.
PENDAHULUAN
Pada survei pendahuluan tanggal 17 April 2021 Direksi dan Tim Konsultan
berkunjung ke 2 kecamatan dan 4 Desa yang Potensial dibangun Instalasi Air baku di
Kabupaten Bandung Barat, dalam rangka memperoleh Informasi pendahuluan yang
relevan terkait penentuan dan pemilihan lokasi. Adapun kecamatan yang dikunjungi ialah
Kecamatan Cipongkor meliputi Desa Cibenda dan Baranangsiang serta Kecamatan Rongga
meliputi Desa Sukaresmi dan Cinengah.
Dari 65 lokasi yang telah teridentifikasi pada pekerjaan sebelumnya, kemudian akan
melakukan analisa pemilihan lokasi untuk dapat dilakukan detail desainnya. Pemilihan
lokasi dilakukan dengan sistem scorring, dengan parameter yang dipertimbangkan sebagai
berikut:
1. Jumlah penduduk daerah layanan
2. Produk Domestik Regional Bruto desa layanan
3. Daerah layanan PDAM
4. Dabit
5. Kecukupan air
6. Perbedaan tinggi sumber air dengan desa layanan
7. Kualitas air
8. Jarak antara mata air terkdekat
9. Kesulitan Medan
10. Jarak dengan titik referensi terdekat
Berikut hasil rekapitulasi kondisi sumber air berdasarkan parameter yang akan
digunakan dalam analisa pemilihan lokasi.
1
FINAL LAPORAN ANTARA
DETAIL PRASARANA PENYEDIAAN AIR BAKU
DI KABUPATEN BANDUNG BARAT
I.3 Metode Penentuan Ranking
Setelah diberikan skor terhadap setiap kriteria sumber air, kemudian setiap kriteria
tersebut diberikan bobot untuk menentukan rangking prioritas terhadap sumber air. Berikut
bobot penilaian rangking untuk setiap kriteria sumber air.
Tabel I-1 bobot Penilaian untuk Penentuan Ranking
2
FINAL LAPORAN ANTARA
DETAIL PRASARANA PENYEDIAAN AIR BAKU
DI KABUPATEN BANDUNG BARAT
Berdasarkan hasil di atas, dilakukan analisa lebih lanjut untuk perencanaan sistem
SPAM komunal dengan membandingkan kondisi elevasi antar mata air dan lokasi layanan.
Berdasarkan analisa tersebut didapatkan kesimpulan:
1. Lokasi yang akan dilakukan studi lanjutan.
a. MA Cijambu, Desa Cinengah
b. MA Curug Goong, Desa Cinengah
c. MA Cipeundeuy, Desa Baranangsiang
d. MA Suramanggala, Desa Baranangsiang
2. Tidak dapat dilakukannya SPAM Komunal, karna kondisi lapangan dan kondisi
layanan yang tidak memungkinkan dan tidak efektive.
b. Identifikasi ke-2
Pada survey identifikasi ke-2 tanggal 3 Juni 2021 bertepatan dengan Musim
Kemarau Survey dilaksanakan pada 4 lokasi yaitu MA. Cipendeuy, MA.
Suramanggala, MA. Cijambu, dan MA. Curug Goong. Berikut hasil identifikasi
lapangan ke-2:
Tabel I-3 Hasil Survei Identifikasi Lapangan ke-2
Debit Rerata
No. Kecamatan Desa Mata Air Foto
(l/s)
Suramanggala 0,467
3
FINAL LAPORAN ANTARA
DETAIL PRASARANA PENYEDIAAN AIR BAKU
DI KABUPATEN BANDUNG BARAT
Debit Rerata
No. Kecamatan Desa Mata Air Foto
(l/s)
Curug Goong
0,4076
II
4
FINAL LAPORAN ANTARA
DETAIL PRASARANA PENYEDIAAN AIR BAKU
DI KABUPATEN BANDUNG BARAT
identifikasi-2 ini maka Mata air Curug
Goong 1 dan Curug Goong 2 bisa
dikomunalkan. Karena jaraknya dekat
hanya kurang lebih 10 meter.
5
FINAL LAPORAN ANTARA
DETAIL PRASARANA PENYEDIAAN AIR BAKU
DI KABUPATEN BANDUNG BARAT
B.
GAMBARAN UMUM WILAYAH CALON LOKASI TERPILIH
Gambar II-1 Peta Orientasi Kabupaten Bandung Barat dalam wilayah Provinsi Jawa Barat
Sumber: RTRW Kabupaten Bandung Barat Tahun 2009-2029
1
FINAL LAPORAN ANTARA
DETAIL PRASARANA PENYEDIAAN AIR BAKU
DI KABUPATEN BANDUNG BARAT
2
FINAL LAPORAN ANTARA
DETAIL PRASARANA PENYEDIAAN AIR BAKU
DI KABUPATEN BANDUNG BARAT
3
FINAL LAPORAN ANTARA
DETAIL PRASARANA PENYEDIAAN AIR BAKU
DI KABUPATEN BANDUNG BARAT
C.
PELAKSANAAN SURVEI LAPANGAN
1
FINAL LAPORAN ANTARA
DETAIL PRASARANA PENYEDIAAN AIR BAKU
DI KABUPATEN BANDUNG BARAT
2
FINAL LAPORAN ANTARA
DETAIL PRASARANA PENYEDIAAN AIR BAKU
DI KABUPATEN BANDUNG BARAT
Gambar III-2 Hasil Kontur Pengukuran Topografi Pada Jaringan Distibusi di MA. Curug
Goong
3
FINAL LAPORAN ANTARA
DETAIL PRASARANA PENYEDIAAN AIR BAKU
DI KABUPATEN BANDUNG BARAT
Gambar III-3 Hasil Kontur Pengukuran Topografi Pada Jaringan Distibusi di MA. Saguling
4
FINAL LAPORAN ANTARA
DETAIL PRASARANA PENYEDIAAN AIR BAKU
DI KABUPATEN BANDUNG BARAT
Gambar III-4 Hasil Kontur Pengukuran Topografi Pada Jaringan Distibusi di MA.
Suramanggala
5
FINAL LAPORAN ANTARA
DETAIL PRASARANA PENYEDIAAN AIR BAKU
DI KABUPATEN BANDUNG BARAT
Gambar III-5 Kegiatan Pengecekan Alat untuk Survey Topografi Bersama Direksi
Gambar III-6 Pelaksanaan Survey Topografi di MA. Curug Goong, Desa Cinengah, Kec.
Rongga
Gambar III-8 Pelaksanaan Survey Topografi di MA. Saguling, Desa Baranangsiang, Kec.
Cipongkor
Survey hidrometri dilakukan untuk mengukur debit sesaat yang akan digunakan
dalam analisa ketersediaan air.
6
FINAL LAPORAN ANTARA
DETAIL PRASARANA PENYEDIAAN AIR BAKU
DI KABUPATEN BANDUNG BARAT
2. MA Cijambu
Cijambu Satuan
1 Debit 0,201 L/s
2 pH 5,5
3 TDS 82
4 suhu 25,5 ˚C
2. MA Suramanggala
Suramanggala Satuan
1 Debit 0,60 L/s
2 pH 7
7
FINAL LAPORAN ANTARA
DETAIL PRASARANA PENYEDIAAN AIR BAKU
DI KABUPATEN BANDUNG BARAT
8
FINAL LAPORAN ANTARA
DETAIL PRASARANA PENYEDIAAN AIR BAKU
DI KABUPATEN BANDUNG BARAT
Gambar III-9 Pelaksanaan Survey Sosial Ekonomi dan Lingkungan - Pembagian dan
Pengisian Kuesioner
9
FINAL LAPORAN ANTARA
DETAIL PRASARANA PENYEDIAAN AIR BAKU
DI KABUPATEN BANDUNG BARAT
D.
ANALISIS SOSIAL EKONOMI
1
FINAL LAPORAN ANTARA
DETAIL PRASARANA PENYEDIAAN AIR BAKU
DI KABUPATEN BANDUNG BARAT
diberikan interpretasi dan analisis hasil penelitian yang ditarik dari permasalahan yang ada
pada masa sekarang.
Survei sosial ekonomi ini dilaksanakan dengan cara mengumpulkan data primer dan
sekunder dari instansi terkait seperti data kependudukan, penyebaran kuesioner dan
wawancara penduduk di setiap desa lokasi mata air. Penyebaran Kuesioner sekurang-
kurangnya 25 responden pada setiap desa yaitu Desa Baranangsiang dan Desa Cinengah.
IV.1.2 Kondisi Sosial Ekonomi
1. Tinjauan Kependudukan
Gambaran kependudukan pada Desa Baranangsiang dan Desa Cinengah yaitu:
Tabel IV-6 Jumlah Penduduk
No. Kecamatan Desa Luas (km2) Jumlah Penduduk
1. Cipongkor Baranangsiang 16 8.268
2. Rongga Cinengah 9 5.428
Sumber: BPS, Tahun 2019
2. Tinjauan Sosial Ekomoni
Kondisi sosial ekonomi masyarakat merupakan gambaran dari kondisi kemampuan
masyarakat dalam menjalani kehidupan sosialnya.
Tabel IV-7 Jumlah Penduduk Berdasarkan Mata Pencaharian
No. Desa Pertanian Perindustrian Gas Perdagangan
1. Baranangsiang 961 0 2 481
2, Cinengah 1.108 37 5 485
Sumber: BPS, Tahun 2019
3. Tinjauan Sosial Budaya
a. Agama dan Sarana Ibadat
Agama yang di anut warga Desa Baranangsiang dan Desa Cinengah sebagian
besar yaitu agama Islam. Selain agama Islam juga terdapat pemeluk agama non
Islam. Berikut jumlah sarana pribadatan yang terdapat di Desa Baranangsiang dan
Desa Cinengah:
Tabel IV-8 Jumlah Saran Peribadatan
Sarana Peribadatan
No. Desa
Masjid Mushola Gereja Protesta
1. Baranangsiang 21 82 0
2. Cinengah 22 102 0
Sumber: BPS, Tahun 2019
b. Kesehatan
Sarana peribatan terdapat di setiap desa, berikut rincian jumlah sarana kesehatan
yang terdapat di Desa Baranangsiang dan Desa Cinengah:
2
FINAL LAPORAN ANTARA
DETAIL PRASARANA PENYEDIAAN AIR BAKU
DI KABUPATEN BANDUNG BARAT
Gambar IV-10 Usia Responden Penduduk di Desa Baranangsiang dan Desa Cinengah
3
FINAL LAPORAN ANTARA
DETAIL PRASARANA PENYEDIAAN AIR BAKU
DI KABUPATEN BANDUNG BARAT
Gambar IV-11 Jenis Kelamin Responden di Desa Baranangsiang dan Desa Cinengah
Berdasarkan diagram di atas, usia responden dalam survei sosial ekonomi untuk
pekerjaan Detail Prasarana Air Baku di Kabupaten Bandung Barat, khususnya di Desa
Cinengah dan Desa Baranangsiang yaitu berkisar dari 42 tahun hingga 70, sebagian besar
berjenis kelamin laki-laki, dan sebagian besar merupakan penduduk asli Desa
Baranangsiang dan Desa Cinengah.
4
FINAL LAPORAN ANTARA
DETAIL PRASARANA PENYEDIAAN AIR BAKU
DI KABUPATEN BANDUNG BARAT
Gambar IV-13 Tingkat Pendidikan Responden di Desa Barangsiang dan Desa Cinengah
Gambar IV-14 Mata Pencarian Responden di Desa Baranangsiang dan Desa Cinengah
5
FINAL LAPORAN ANTARA
DETAIL PRASARANA PENYEDIAAN AIR BAKU
DI KABUPATEN BANDUNG BARAT
Gambar IV-15 Jenis Lahan yang Dimiliki Penduduk Desa Baranangsiang dan Desa Cinengah
Gambar IV-16 Status Kepemilikan Lahan di Desa Baranangsiang dan Desa Cinengah
6
FINAL LAPORAN ANTARA
DETAIL PRASARANA PENYEDIAAN AIR BAKU
DI KABUPATEN BANDUNG BARAT
Gambar IV-17 Harga Nilai Lahan yang Dimiliki Penduduk Desa Baranangsiang dan Desa
Cinengah
Gambar IV-18 Kondisi Kepemilikan Lahan di Desa Barangsiang dan Desa Cinengah
Gambar IV-19 Kondisi Penggunaan Listrik pada Lahan di Desa Baranangsiang dan Desa
Cinengah
7
FINAL LAPORAN ANTARA
DETAIL PRASARANA PENYEDIAAN AIR BAKU
DI KABUPATEN BANDUNG BARAT
Gambar IV-20 Jumlah Kendaraan yang Dimiliki Penduduk Desa Baranangsiang dan Desa
Cinengah
8
FINAL LAPORAN ANTARA
DETAIL PRASARANA PENYEDIAAN AIR BAKU
DI KABUPATEN BANDUNG BARAT
Gambar IV-22 Pengeluaran /Bln Penduduk Desa Baranangsiang dan Desa Cinengah
Gambar IV-23 Kondisi Menabung Penduduk Desa Baranangsiang dan Desa Cinengah
9
FINAL LAPORAN ANTARA
DETAIL PRASARANA PENYEDIAAN AIR BAKU
DI KABUPATEN BANDUNG BARAT
Gambar IV-24 Kesehatan / Penyakit yang Pernah Diderita Masyarakt Desa Baranangsiang dan
Desa Cinengah
10
FINAL LAPORAN ANTARA
DETAIL PRASARANA PENYEDIAAN AIR BAKU
DI KABUPATEN BANDUNG BARAT
2. Desa Cinengah
Tabel IV-12 Kondisi Fasilitas Pengelolaan Air di Desa Cinengah
Fasilitas Jumla Responden
Sumber Air untuk Sungai Sumur Mata Air PDAM
Konsumsi - 3 26 -
Sumber Air untuk Sungai Sumur Mata Air PDAM
Mencuci - - 29 -
Ketersediaan Air
Lebih Cukup Kurang
Bersih
- 7 22
Kualitas Air Berbau Berasa Berwarna
- 29 -
Semi Tidak
Fasilitas Sanitasi Permanen
Permanen Memiliki
-9 29 1
Semi Tidak
Fasilitas Drainase Permanen
Permanen Memiliki
- - 30
Diagram kondisi pengelolaan air pada Desa Baranangsiang dan Desa Cinengah dapat
dilihat gambar berikut.
Gambar IV-25 Kondisi Fasilitas Sumber Air untuk Konsumsi di Desa Baranangsiang dan
Desa Cinengah
11
FINAL LAPORAN ANTARA
DETAIL PRASARANA PENYEDIAAN AIR BAKU
DI KABUPATEN BANDUNG BARAT
Gambar IV-26 Kondisi Sumber Air untuk Mencuci di Desa Baranangsiang dan Desa
Cinengah
Gambar IV-27 Kondisi Ketersediaan Air di Desa Baranangsiang dan Desa Cinengah
12
FINAL LAPORAN ANTARA
DETAIL PRASARANA PENYEDIAAN AIR BAKU
DI KABUPATEN BANDUNG BARAT
Gambar IV-29 Ketersediaan Fasilitas Sanitasi di Desa Baranangsiang dan Desa Cinengah
Gambar IV-30 Ketersediaan Fasilitas Drainase di Desa Baranangsiang dan Desa Cinengah
13
FINAL LAPORAN ANTARA
DETAIL PRASARANA PENYEDIAAN AIR BAKU
DI KABUPATEN BANDUNG BARAT
Gambar IV-31 Ketersediaan Saluran Langsung Ke Rumah Desa Baranangsiang dan Desa
Cinengah
Gambar IV-32 Ketersediaan Sumber Air Komunal Desa Baranangsiang dan Desa Cinengah
Gambar IV-33 Harapan Terhadap Sumber Air Baru di Desa Baranangsiang dan Desa
Cinengah
14
FINAL LAPORAN ANTARA
DETAIL PRASARANA PENYEDIAAN AIR BAKU
DI KABUPATEN BANDUNG BARAT
Gambar IV-34 Sumber Air yang Diharapkan Desa Baranangsiang dan Desa Cinengah
Gambar IV-36 Tindak Darurat Penanganan Kekeringan di Desa Baranangsiang dan Desa
Cinengah
15
FINAL LAPORAN ANTARA
DETAIL PRASARANA PENYEDIAAN AIR BAKU
DI KABUPATEN BANDUNG BARAT
Gambar IV-37 Upaya Aparat Desa Untuk Memenuhi Kebutuhan Air Desa Baranangsiang
dan Desa Cinengah
16
FINAL LAPORAN ANTARA
DETAIL PRASARANA PENYEDIAAN AIR BAKU
DI KABUPATEN BANDUNG BARAT
Gambar IV-39 Sistem Ganti Rugi yang Diharapkan Msyarakat Desa Baranangsiang dan
Desa Cinengah
17
FINAL LAPORAN ANTARA
DETAIL PRASARANA PENYEDIAAN AIR BAKU
DI KABUPATEN BANDUNG BARAT
E.
ANALISIS LINGKUNGAN DAN KUALITAS AIR
Komponen yang dilihat pada pengukuran secara visual yaitu kondisi pH dan
kekeruhan pada setiap mata air. Hasil kualitas air dari perukuran di lapangan dapat dilihat
pada Tabel V-1.
Tabel V-13 Hasil Kualitas Air Berdasarkan Pengukuran Secara Visual
Kekeruhan
Desa Sumber Mata Air Debit (L/dtk) pH
(Ya/Tidak)
1. MA. Cipeundeuy
Tabel V-14 Hasil Uji Laboratorium Kualitas Air MA. Cipeundeuy
FISIKA
1 Kekeruhan NTU 25 6,34 SNI 06-6989.25-2005
2 Warna TCU 50 15 SNI 06-6989.24-2005
Padatan Terlarut Total
3 mg/L 1,000 90,00 SNI 6989.27:2019
(TDS)
4 Bau - Tidak Berbau Tidak Berbau Organoleptik
MIKROBIOLOGI
CFU/100
1 50 16 APHA 9222-B-2017*
Total Coliform mL
CFU/100
2 0 2,2A APHA 9222-B-2017*
E. Coli mL
KIMIA
1 pH - 6,5 - 8,5 6.722 SNI 6989.11-2019
2 Flourida (F) mg/L 1,5 0,0433 SNI 06-6989.29-2005
1
FINAL LAPORAN ANTARA
DETAIL PRASARANA PENYEDIAAN AIR BAKU
DI KABUPATEN BANDUNG BARAT
3
FINAL LAPORAN ANTARA
DETAIL PRASARANA PENYEDIAAN AIR BAKU
DI KABUPATEN BANDUNG BARAT
SNI 06-6989.29-
2 mg/L 1,5 0,0394
Flourida (F) 2005
SNI 06-6989.12-
3 mg/L 500 46,08
Kesadahan Total (CaCO₃) 2004
4 Nitrat sebagai N mg/L 10 1,3139 SNI 6989.79:2011
5 Nitrit sebagai N mg/L 1 0,0387 SNI 06-6989.9-2004
SNI 06-6989.51-
6 mg/L 0,5 0,0142
Deterjen (MBAS) 2005
Krom Heksavalent (Cr-
7 mg/L 0,05 < 0,0032 SNI 6989.71:2009
VI)
Nilai Permanganat SNI 06-6989.22-
8 mg/L 10 3,32
(KMnO₄) 2004
5. MA. Curug Goong
Tabel V-18 Hasil Uji Laboratorium Kualitas Air MA. Curug Goong
BAKU
HASIL METODE ACUAN
N PARAMETER SATUAN MUTU
PENGUJIAN Method of
O Parameter Unit Specificatio
Testing Result Reference
n
FISIKA
SNI 06-6989.25-
1 NTU 25 0,15
Kekeruhan 2005
SNI 06-6989.24-
2 TCU 50 5
Warna 2005
Padatan Terlarut Total
3 mg/L 1,000 114,00 SNI 6989.27:2019
(TDS)
Tidak
4 - Tidak Berbau Organoleptik
Bau Berbau
MIKROBIOLOGI
CFU/100
1 50 3,6 APHA 9222-B-2017*
Total Coliform mL
CFU/100
2 0 3,6A APHA 9222-B-2017*
E. Coli mL
KIMIA
1 pH - 6,5 - 8,5 6.036 SNI 6989.11-2019
SNI 06-6989.29-
2 mg/L 1,5 0,0528
Flourida (F) 2005
SNI 06-6989.12-
3 mg/L 500 99,07
Kesadahan Total (CaCO₃) 2004
4 Nitrat sebagai N mg/L 10 < 0,0031 SNI 6989.79:2011
5 Nitrit sebagai N mg/L 1 0,0061 SNI 06-6989.9-2004
SNI 06-6989.51-
6 mg/L 0,5 0,0092
Deterjen (MBAS) 2005
Krom Heksavalent (Cr-
7 mg/L 0,05 < 0,0032 SNI 6989.71:2009
VI)
Nilai Permanganat SNI 06-6989.22-
8 mg/L 10 2,37
(KMnO₄) 2004
6. MA. Sampora
Tabel V-19 Hasil Uji Laboratorium Kualitas Air MA. Sampora
BAKU
HASIL METODE ACUAN
N PARAMETER SATUAN MUTU
PENGUJIAN Method of
O Parameter Unit Specificatio
Testing Result Reference
n
4
FINAL LAPORAN ANTARA
DETAIL PRASARANA PENYEDIAAN AIR BAKU
DI KABUPATEN BANDUNG BARAT
FISIKA
SNI 06-6989.25-
1 NTU 25 8,26
Kekeruhan 2005
SNI 06-6989.24-
2 TCU 50 5
Warna 2005
Padatan Terlarut Total
3 mg/L 1,000 30,00 SNI 6989.27:2019
(TDS)
Tidak
4 - Tidak Berbau Organoleptik
Bau Berbau
MIKROBIOLOGI
CFU/100
1 50 2,2 APHA 9222-B-2017*
Total Coliform mL
CFU/100
2 0 1,1A APHA 9222-B-2017*
E. Coli mL
KIMIA
1 pH - 6,5 - 8,5 6.610 SNI 6989.11-2019
SNI 06-6989.29-
2 mg/L 1,5 0,0630
Flourida (F) 2005
SNI 06-6989.12-
3 mg/L 500 15,36
Kesadahan Total (CaCO₃) 2004
4 Nitrat sebagai N mg/L 10 2,4887 SNI 6989.79:2011
5 Nitrit sebagai N mg/L 1 0,0133 SNI 06-6989.9-2004
SNI 06-6989.51-
6 mg/L 0,5 0,0090
Deterjen (MBAS) 2005
Krom Heksavalent (Cr-
7 mg/L 0,05 < 0,0032 SNI 6989.71:2009
VI)
Nilai Permanganat SNI 06-6989.22-
8 mg/L 10 4,90
(KMnO₄) 2004
7. MA. Warudoyong
Tabel V-20 Hasil Uji Laboratorium Kualitas Air MA. Warudoyong
BAKU
HASIL METODE ACUAN
N PARAMETER SATUAN MUTU
PENGUJIAN Method of
O Parameter Unit Specificatio
Testing Result Reference
n
FISIKA
SNI 06-6989.25-
1 NTU 25 0,55
Kekeruhan 2005
SNI 06-6989.24-
2 TCU 50 5
Warna 2005
Padatan Terlarut Total
3 mg/L 1,000 76,00 SNI 6989.27:2019
(TDS)
Tidak
4 - Tidak Berbau Organoleptik
Bau Berbau
MIKROBIOLOGI
CFU/100
1 50 3,6 APHA 9222-B-2017*
Total Coliform mL
CFU/100
2 0 3,6A APHA 9222-B-2017*
E. Coli mL
KIMIA
1 pH - 6,5 - 8,5 5.861 SNI 6989.11-2019
SNI 06-6989.29-
2 mg/L 1,5 0,0334
Flourida (F) 2005
5
FINAL LAPORAN ANTARA
DETAIL PRASARANA PENYEDIAAN AIR BAKU
DI KABUPATEN BANDUNG BARAT
Keterangan:
6
FINAL LAPORAN ANTARA
DETAIL PRASARANA PENYEDIAAN AIR BAKU
DI KABUPATEN BANDUNG BARAT
b. Air untuk keperluan gigiene sanitasi adalah air dengan kualitas tertentu yang
digunakan untuk keperlun sehari-hari yang kualitasnya berbeda dengan kualitas air
minum.
c. American Public Health Association, Standart Methode Edisi ke 23 tahun 2017 (*)
d. Huruf bercetak tebal menunjukkan parameter yang tidak terakreditasi
e. Tidak memenuhi Baku Mutu yang dipersyaratkan (^)
7
FINAL LAPORAN ANTARA
DETAIL PRASARANA PENYEDIAAN AIR BAKU
DI KABUPATEN BANDUNG BARAT
F.
ANALISIS HIDROLOGI DAN HIDRAULIKA
Ketersediaan
Kecamatan Desa Mata Air
L/dtk L/hari
Cipongkor Baranangsiang Suramanggala 0,60 52.036,50
Saguling 0,15 13.193,28
Rongga Cinengah Curug Goong 1,86 161.006,40
Curug Goong II 0,41 35.216,64
1
FINAL LAPORAN ANTARA
DETAIL PRASARANA PENYEDIAAN AIR BAKU
DI KABUPATEN BANDUNG BARAT
Tabel VI-23 Curah Hujan Bulanan Rata-Rata St. Cidadap Montoya-Gn. Halu
Bulan (mm)
Tahun
Jan Feb Mar Apr Mei Jun Jul Ags Sep Okt Nov Des
2005 213 310 141 71 52 95 72 24 78 139 269 194
2006 222 312 247,32 384 136 33 0 27 0 104 180 285
2007 113 383 104,5 216 65 36 0 68,2 5,5 148 544,4 797
2008 191,2 144 282 131 67 6 9 70 45 292 187 103
2009 159 313 351 201 267 45 24 10 80 370 306 138
2010 408 336 326 126 219 99 83 113 228 211 162 233
2011 120,5 314,5 310 353,5 269 98,5 8 3 7 134 412,5 332,5
2012 236,8 313,8 314 335 198 79,2 14 0 38,5 133 492 373
2013 324 327,5 267 492,5 246,5 72,5 262 42 176 238 198,5 388
2014 235 223 303 186,5 230 64 38 132 0 124,5 379 345
2015 163 294 218 209,5 188,5 0 0 0 50 59 572,1 333,5
113,
2016 245 341,5 294 257,5 285,5 114,5 225,5 281 357 302,5 113,5
5
2017 348,5 469,5 191 0 0 0 16 10 40,5 229,4 9 240,5
2018 181 293 329,5 361,5 112 25 0 0 76,5 222 431 128
2019 378 304 150 316,5 107 0 0 0 0 101,5 61 599
222,2 48,9
Rata-Rata 297,68 264,582 249,65 174,95 62,82 51 65,8 189,35 313,04 318,85
5 2
Bulan (mm)
Ranking Probabilitas
Jan Feb Mar Apr Mei Jun Jul Ags Sep Okt Nov Des
5 4 5
C. Evapotranspirasi
Berdasarkan data klimatologi yang telah diperoleh dari stasiun klimatologi
terdekat, maka dapat dihitung besarnya evapotranspirasi di lokasi pekerjaan dengan
mempergunakan rumus:
Ehari = 0.36 x (ea – ed) x (1 + (v/10)
Dimana:
Ehari = Evaporasi per hari (dalam mm hari)
ea = Tekanan uap jenuh (dalam mmHG)
ed = Tekanan uap aktual / di udara (mmHG)
v = Kecepatan angin (dalam mil/jam)
Berikut data klimatologi yang diperoleh dari Sta. Cirata:
a. Temperatur Rata-Rata (0C)
Tabel VI-25 Data Ttemperatur Rata-Rata St. Cirata
Bulan (mm)
Tahun
Jan Feb Mar Apr Mei Jun Jul Ags Sep Okt Nov Des
2002 - - - - 23,90 23,80 24,00 24,00 24,80 25,50 25,00 24,40
20,7
2004 23,25 23,25 20,57 23,25 23,19 25,64 28,69 26,80 27,98 23,25 23,25
9
25,3
2005 26,17 - 25,66 23,74 25,35 25,18 25,18 26,21 25,98 25,38 24,87
4
25,2
2006 24,47 25,30 25,47 25,34 24,08 24,53 24,73 25,40 26,26 25,87 25,23
7
24,1
2007 25,20 23,50 23,90 24,20 24,30 24,30 24,40 25,50 20,10 - 24,50
0
24,7
2008 24,81 24,50 24,98 23,55 22,17 23,03 23,48 24,40 - - -
1
2009 23,30 22,70 - 22,80 - 27,70 - 23,80 24,20 - 24,80 27,90
28,6
2010 27,20 28,50 33,23 29,42 28,20 27,69 28,48 28,30 28,90 28,70 28,20
1
29,2
2011 28,00 29,00 29,00 29,00 28,00 27,00 26,00 22,00 24,00 25,00 23,00
0
Rata- 25,4
25,30 25,25 25,70 25,30 25,20 25,17 25,42 25,29 25,53 25,43 25,17
Rata 3
50,7
2005 47,50 - 50,47 46,68 50,00 53,23 53,31 53,00 50,81 51,00 49,11
2
48,7
2006 46,69 48,48 48,58 47,42 53,25 50,81 57,34 58,42 58,39 55,33 52,34
9
46,2
2007 47,97 49,62 47,50 49,69 50,50 46,41 50,16 51,33 53,59 - 57,50
5
54,5
2008 52,02 58,04 54,17 50,16 52,50 46,45 48,39 47,17 - - -
2
2009 - - - - - - - - - - - -
49,1
2010 44,21 46,32 45,52 48,47 51,25 49,19 47,34 49,13 48,23 49,17 48,15
8
47,0
2011 47,98 47,91 47,83 49,27 50,88 50,75 54,68 51,83 63,31 61,75 64,27
2
Rata- 49,4
47,98 49,98 49,01 48,64 50,50 48,60 50,96 49,81 51,88 51,89 52,61
Rata 1
4
FINAL LAPORAN ANTARA
DETAIL PRASARANA PENYEDIAAN AIR BAKU
DI KABUPATEN BANDUNG BARAT
Bulan (km/jam)
Tahun
Jan Feb Mar Apr Mei Jun Jul Ags Sep Okt Nov Des
1 3
0,6 0,9 1,5
2010 0,76 0,90 1,60 2,17 0,54 0,66 0,47 1,22 0,40
5 8 3
0,5 1,2 1,9
2011 0,59 0,67 0,39 2,18 0,48 1,55 1,69 1,45 2,17
7 3 6
1,5 1,9 1,7
Rata-Rata 1,11 1,16 1,43 1,53 1,38 1,46 1,91 1,91 3,31
8 6 5
Evapotranspirasi Potensial dari suatu permukaan air yang tipis dipengaruhi oleh
faktor-faktor meteorologis yang sama: radiasi, kelembaban, angin, dan temperatur.
Evapotranspirasi potensial adalah evapotranspirasi yang mungkin terjadi pada kondisi air
yang tersedia berlebihan. Faktor penting yang mempengaruhi evapotranspirasi potensial
adalah tersedianya air yang cukup banyak. Jika jumlah air selalu tersedia secara berlebihan
dari yang diperlukan oleh tanaman selama proses transpirasi, maka jumlah air yang
ditranspirasikan akan relatif lebih besar dibandingkan apabila tersedianya air di bawah
keperluan. Untuk perhitungan Evapotranspirasi Potensial dipakai metode Penman yang
dimodifikasi oleh FAO tahun 1991:
Evapotranspirasi dalam keadaan standar dihitung dengan rumus berikut ini:
ETo = C [W x Rn + (1-W) x f(v) x (ea-ed)
Dimana:
ETo = Evapotranspirasi pada keadaan standar (mm/hari)
W = Faktor temperatur
Rn = Radiasi matahari (mm/hari)
f (v) = Faktor kecepatan angin
(ea-ed) = Perbedaan antara tekanan uap air jenuh pada suhu udara rata-rata dengan
rata-rata tekanan uap air di udara (mbar)
C =Faktor koreksi akibat keadaan iklim
Hasil perhitungan evapotranspirasi potensial menggunakan metode Penman-
Montieth (FAO 1991) disajikan pada tabel di bawah ini:
5
FINAL LAPORAN ANTARA
DETAIL PRASARANA PENYEDIAAN AIR BAKU DI KABUPATEN BANDUNG BARAT
ET0 (mm/hari) 2,43 2,42 2,31 2,22 2,03 1,82 1,85 2,09 2,38 2,49 2,46 2,67
7
FINAL LAPORAN ANTARA
DETAIL PRASARANA PENYEDIAAN AIR BAKU DI KABUPATEN BANDUNG BARAT
8
FINAL LAPORAN ANTARA
DETAIL PRASARANA PENYEDIAAN AIR BAKU DI KABUPATEN BANDUNG BARAT
Qmd = Q x fmd
dengan pengertian:
Qmd = kebutuhan air (liter/hari)
q = konsumsi air per orang per hari (liter/orang/hari)
P = jumlah jiwa yang akan dilayani sesuai tahun perencanaan (jiwa)
f = faktor maksimum (1,05—1,15)
- Kebutuhan air total dihitung dengan persamaan:
Qt = 1,2 x Qmd x 100/80
dengan pengertian:
Qt = kebutuhan air total dengan faktor kehilangan air 20%
c. Analisa Kebutuhan Domestik
Kebutuhan domestik merupakan kebutuhan air bersih yang digunakan untuk
keperluan rumah tangga dan sambungan kran umum, yang jumlah kebutuhannya
ditentukan dari catatan (data) dari daerah bersangkutan berdasarkan karakteristik dan
perkembangan konsumen pemakai air bersih. Semakin besar suatu kota maka tingkat
kebutuhan air akan semakin besar, demikian pula semakin modern suatu masyarakat
maka konsumsi air juga semakin besar.
d. Kebutuhan Non Domestik
Kebutuhan non domestik merupakan kebutuhan air bersih selain untuk keperluan
rumah tangga dan sambungan kran umum, seperti penyediaan air untuk sarana
sosial, tempat ibadah, sekolah, rumah sakit, asrama, dan juga untuk keperluan
komersil, seperti industri, hotel, dagangan, pelabuhan serta untuk pelayanan jasa
umum.
Kebutuhan air penduduk akan dihitung berdasarkan beberapa jenis kebutuhan, antara
lain :
1. Kebutuhan air bersih domestik untuk sambungan rumah dan kran umum
2. Kebutuhan air non domestik, misalnya untuk fasilitas peribadatan dan kran
umum, diperhitungkan sebesar 15% dari kebutuhan domestik.
3. Kehilangan air
4. Kebutuhan hari maksimum, diperhitungkan sebesar 1,25% kebutuhan air bersih
5. Kebutuhan jam puncak, diperhitungkan sebesar 1,75% kebutuhan air bersih.
Selanjutnya kebutuhan air bersih penduduk dapat dirumuskan sebagai berikut :
Keb. Total = Kebutuhan Domestik + Kebutuhan Air Sosial + Kehilangan Air
10
FINAL LAPORAN ANTARA
DETAIL PRASARANA PENYEDIAAN AIR BAKU DI KABUPATEN BANDUNG BARAT
1.8
1.6
1.4
Load Factor
1.2
Fluktuasi pemakaian air bersih
1 Rata-rata pemakaian air bersih
0.8
0.6
0.4
0.2
0
0 2 4 6 8 10 12 14 16 18 20 22 24
Jam
Gambar VI-40 Grafik Fluktuasi Pemakaian Air Bersih
Sumber : DPUD Jendral Cipta Karya Direktorat Air Bersih
Tabel VI-32 Faktor Pengali (Load Factor) Terhadap Kebutuhan Air Bersih
Jam 1 2 3 4 5 6 7 8 9 10 11 12
Load Factor 0,3 0,37 0,45 0,64 1,15 1,4 1,53 1,56 1,41 1,38 1,27 1,2
Jam 13 14 15 16 17 18 19 20 21 22 23 24
Load Factor 1,14 1,17 1,18 1,22 1,31 1,38 1,25 0,98 0,62 0,45 0,37 0,25
Sumber : DPUD Jendral Cipta Karya 1994 : 24
11
FINAL LAPORAN ANTARA
DETAIL PRASARANA PENYEDIAAN AIR BAKU DI KABUPATEN BANDUNG BARAT
12
FINAL LAPORAN ANTARA
DETAIL PRASARANA PENYEDIAAN AIR BAKU DI KABUPATEN BANDUNG BARAT
Tabel VI-34 Hasil Perhitungan Kebutuhan Air Layanan Mata Air Saguling
Tahun
Kebutuhan Air Saguling Satuan
2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034 2035 2036 2037 2038 2039 2040 2041 2042 2043 2044 2045
Kependudukan
Penduduk Terlayani Jiwa 186 188 190 192 194 196 198 200 202 204 206 208 210 212 214 216 219 222 225 228 231 234 237 240 243 246
Pertumbuhan Penduduk % 0,93 0,93 0,93 0,93 0,93 0,93 0,93 0,93 0,93 0,93 0,93 0,93 0,93 0,93 0,93 0,93 0,93 0,93 0,93 0,93 0,93 0,93 0,93 0,93 0,93 0,93
Kebutuhan Air
Pemakaian per orang lt/hari 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
Pemakaian per orang lt/dtk 0,0007 0,0007 0,0007 0,0007 0,0007 0,0007 0,0007 0,0007 0,0007 0,0007 0,0007 0,0007 0,0007 0,0007 0,0007 0,0007 0,0007 0,0007 0,0007 0,0007 0,0007 0,0007 0,0007 0,0007 0,0007 0,0007
Kebutuhan Air Domestik lt/dtk 0,129 0,131 0,132 0,133 0,135 0,136 0,138 0,139 0,140 0,142 0,143 0,144 0,146 0,147 0,149 0,150 0,152 0,154 0,156 0,158 0,160 0,163 0,165 0,167 0,169 0,171
Kebutuhan Air Non Domestik lt/dtk 0,019 0,020 0,020 0,020 0,020 0,020 0,021 0,021 0,021 0,021 0,021 0,022 0,022 0,022 0,022 0,023 0,023 0,023 0,023 0,024 0,024 0,024 0,025 0,025 0,025 0,026
Kebutuhan Air Total lt/dtk 0,149 0,150 0,152 0,153 0,155 0,157 0,158 0,160 0,161 0,163 0,165 0,166 0,168 0,169 0,171 0,173 0,175 0,177 0,180 0,182 0,184 0,187 0,189 0,192 0,194 0,196
Kehilangan Air
%Kehilangan Air % 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20
Jumlah Kehilangan Air lt/dtk 0,030 0,030 0,030 0,031 0,031 0,031 0,032 0,032 0,032 0,033 0,033 0,033 0,034 0,034 0,034 0,035 0,035 0,035 0,036 0,036 0,037 0,037 0,038 0,038 0,039 0,039
Kebutuhan Air Rata-Rata lt/dtk 0,178 0,180 0,182 0,184 0,186 0,188 0,190 0,192 0,194 0,196 0,197 0,199 0,201 0,203 0,205 0,207 0,210 0,213 0,216 0,219 0,221 0,224 0,227 0,230 0,233 0,24
Kebutuhan Hari Maksimum
Faktor koefisien 1,25 1,25 1,25 1,25 1,25 1,25 1,25 1,25 1,25 1,25 1,25 1,25 1,25 1,25 1,25 1,25 1,25 1,25 1,25 1,25 1,25 1,25 1,25 1,25 1,25 1,25
Kebutuhan Air lt/dtk 0,223 0,225 0,228 0,230 0,232 0,235 0,237 0,240 0,242 0,244 0,247 0,249 0,252 0,254 0,256 0,259 0,262 0,266 0,270 0,273 0,277 0,280 0,284 0,288 0,291 0,295
Kebutuhan Jam Puncak
Faktor koefisien 1,75 1,75 1,75 1,75 1,75 1,75 1,75 1,75 1,75 1,75 1,75 1,75 1,75 1,75 1,75 1,75 1,75 1,75 1,75 1,75 1,75 1,75 1,75 1,75 1,75 1,75
Kebutuhan Air lt/dtk 0,312 0,315 0,319 0,322 0,325 0,329 0,332 0,335 0,339 0,342 0,345 0,349 0,352 0,356 0,359 0,362 0,367 0,372 0,377 0,382 0,387 0,392 0,397 0,403 0,408 0,4126
m3/dtk 0,0003 0,0003 0,0003 0,0003 0,0003 0,0003 0,0003 0,0003 0,0003 0,0003 0,0003 0,0003 0,0004 0,0004 0,0004 0,0004 0,0004 0,0004 0,0004 0,0004 0,0004 0,0004 0,0004 0,0004 0,0004 0,0004
Tabel VI-35 Hasil Perhitungan Kebutuhan Air Layanan Mata Air Suramanggala
Tahun
Kebutuhan Air Suramanggala Satuan
2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034 2035 2036 2037 2038 2039 2040 2041 2042 2043 2044 2045
Kependudukan
Penduduk Terlayani Jiwa 498 503 508 513 518 523 528 533 538 544 550 556 562 568 574 580 586 592 598 604 610 616 622 628 634 640
Pertumbuhan Penduduk % 0,93 0,93 0,93 0,93 0,93 0,93 0,93 0,93 0,93 0,93 0,93 0,93 0,93 0,93 0,93 0,93 0,93 0,93 0,93 0,93 0,93 0,93 0,93 0,93 0,93 0,93
Kebutuhan Air
Pemakaian per orang lt/hari 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60
Pemakaian per orang lt/dtk 0,0007 0,0007 0,0007 0,0007 0,0007 0,0007 0,0007 0,0007 0,0007 0,0007 0,0007 0,0007 0,0007 0,0007 0,0007 0,0007 0,0007 0,0007 0,0007 0,0007 0,0007 0,0007 0,0007 0,0007 0,0007 0,0007
Kebutuhan Air Domestik lt/dtk 0,346 0,349 0,353 0,356 0,360 0,363 0,367 0,370 0,374 0,378 0,382 0,386 0,390 0,394 0,399 0,403 0,407 0,411 0,415 0,419 0,424 0,428 0,432 0,436 0,440 0,444
Kebutuhan Air Non Domestik lt/dtk 0,052 0,052 0,053 0,053 0,054 0,054 0,055 0,056 0,056 0,057 0,057 0,058 0,059 0,059 0,060 0,060 0,061 0,062 0,062 0,063 0,064 0,064 0,065 0,065 0,066 0,067
Kebutuhan Air Total lt/dtk 0,398 0,402 0,406 0,410 0,414 0,418 0,422 0,426 0,430 0,434 0,439 0,444 0,449 0,454 0,458 0,463 0,468 0,473 0,478 0,482 0,487 0,492 0,497 0,502 0,506 0,511
Kehilangan Air
%Kehilangan Air % 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20
Jumlah Kehilangan Air lt/dtk 0,080 0,080 0,081 0,082 0,083 0,084 0,084 0,085 0,086 0,087 0,088 0,089 0,090 0,091 0,092 0,093 0,094 0,095 0,096 0,096 0,097 0,098 0,099 0,100 0,101 0,102
Kebutuhan Air Rata-Rata lt/dtk 0,477 0,482 0,487 0,492 0,496 0,501 0,506 0,511 0,516 0,521 0,527 0,533 0,539 0,544 0,550 0,556 0,562 0,567 0,573 0,579 0,585 0,590 0,596 0,602 0,608 0,61
Kebutuhan Hari Maksimum
Faktor koefisien 1,25 1,25 1,25 1,25 1,25 1,25 1,25 1,25 1,25 1,25 1,25 1,25 1,25 1,25 1,25 1,25 1,25 1,25 1,25 1,25 1,25 1,25 1,25 1,25 1,25 1,25
Kebutuhan Air lt/dtk 0,597 0,603 0,609 0,615 0,621 0,627 0,633 0,638 0,644 0,652 0,659 0,666 0,673 0,680 0,688 0,695 0,702 0,709 0,716 0,724 0,731 0,738 0,745 0,752 0,759 0,767
Kebutuhan Jam Puncak
Faktor koefisien 1,75 1,75 1,75 1,75 1,75 1,75 1,75 1,75 1,75 1,75 1,75 1,75 1,75 1,75 1,75 1,75 1,75 1,75 1,75 1,75 1,75 1,75 1,75 1,75 1,75 1,75
Kebutuhan Air lt/dtk 0,835 0,844 0,852 0,860 0,869 0,877 0,886 0,894 0,902 0,912 0,922 0,932 0,943 0,953 0,963 0,973 0,983 0,993 1,003 1,013 1,023 1,033 1,043 1,053 1,063 1,0733
m3/dtk 0,0008 0,0008 0,0009 0,0009 0,0009 0,0009 0,0009 0,0009 0,0009 0,0009 0,0009 0,0009 0,0009 0,0010 0,0010 0,0010 0,0010 0,0010 0,0010 0,0010 0,0010 0,0010 0,0010 0,0011 0,0011 0,0011
13
FINAL LAPORAN ANTARA
DETAIL PRASARANA PENYEDIAAN AIR BAKU DI KABUPATEN BANDUNG BARAT
14
FINAL LAPORAN ANTARA
DETAIL PRASARANA PENYEDIAAN AIR BAKU DI KABUPATEN BANDUNG BARAT
15
FINAL LAPORAN ANTARA
DETAIL PRASARANA PENYEDIAAN AIR BAKU DI KABUPATEN BANDUNG BARAT
16
FINAL LAPORAN ANTARA
DETAIL PRASARANA PENYEDIAAN AIR BAKU DI KABUPATEN BANDUNG BARAT
17
FINAL LAPORAN ANTARA
DETAIL PRASARANA PENYEDIAAN AIR BAKU DI KABUPATEN BANDUNG BARAT
VI.2 Hidrolika
Konsep pengembangan SIS Penyediaan Air Baku di Kabutpaten Bandung barat
adalah sebagai berikut:
- Sumber air baku merupakan mata air
- Penentuan sistem pelayanan yang akan digunakan yaitu sistem gravitas
- Rencana bangunan yang akan didesain meliputi:
• Bangunan penangkap mata air
• Bangunan pengumpul/penampung utama
• Pipa transmisi, direncakan dengan bahan dari pipa HDPE, diameter tergantung
kebutuhan
• Bangunan bagi berupa Hidran Umum
Berdasarkan kriteria desain dan kondisi lokasi masing-masing Mata Air, maka
dapat ditentukan pengembangan untuk masing-masing lokasi
a. Bangunan Penangkap Mata Air:
- Bahan : Pasangan Batu
- Mengitari Mata Air, dilengkapi dengan saluran drainase
b. Bak Penampung Utama (reservoar)
- Bahan : Pasangan Batu
- Bentuk : Persegi
- Dimensi dihitung berdasarkan :
• Debit rata-rata mata air
• Besarnya pemakaian dan waktu (60 lt/orang/hari dengan waktu
pengambilan 12-18 jam/hari)
c. Pipa Transmisi
- Jenis Pipa : HDPE untuk pipa air baku
- Dimensi pipa direncanakan berdasarkan debit rata-rata, kehilangan tekanan
maksimum 5m/1000m.
d. Bangunan Hidran Umum
- Lokasi : disesuaikan dengan lokasi daerah layanan
- Bahan : Pasangan Batu
- Bentuk : Silinder
- Ukuran : Sesuai dengan kebutuhan layanan
18
FINAL LAPORAN ANTARA
DETAIL PRASARANA PENYEDIAAN AIR BAKU DI KABUPATEN BANDUNG BARAT
19
FINAL LAPORAN ANTARA
DETAIL PRASARANA PENYEDIAAN AIR BAKU DI KABUPATEN BANDUNG BARAT
Tabel VI-37 Hasil Analisa Hidrolis Pada Bangunan Air MA. Curug Goong
Network Table - Nodes
Elevation Base Demand Demand Head Pressure
Node ID
m LPS LPS m m
Hidran 1 971,941 0,5193 0,52 978,09 6,15
Hidran 2 969,000 0,311 0,31 977,66 8,66
Hidran 3 965,000 0,311 0,16 977,71 12,71
Resvr R1 981,373 1,1413 981,37 0
Tabel VI-38 Hasil Analisa Hdrolis Pada Pipa Jaringan MA. Curug Goong
Network Table - Links
Flo
Link Length Diameter Roughness Velocity Unit Headloss Friction Factor
w
ID
m mm LPS m/s m/km
Pipe P1 327,34 50 130 1,14 0,58 10,01 0,029
Pipe P2 119,27 50 130 0,62 0,32 3,25 0,032
Pipe P3 55,32 50 130 0,31 0,16 0,9 0,035
20
FINAL LAPORAN ANTARA
DETAIL PRASARANA PENYEDIAAN AIR BAKU DI KABUPATEN BANDUNG BARAT
21
FINAL LAPORAN ANTARA
DETAIL PRASARANA PENYEDIAAN AIR BAKU DI KABUPATEN BANDUNG BARAT
Tabel VI-39 Hasil Analisa Hdrolis Pada Bangunan Air MA. Saguling
Network Table - Nodes
Elevation Base Demand Demand Head Pressure
Node ID m LPS LPS m m
Hidran 1 751,9050 0,077 0,12 768,9 17
Hidran 2 753,5080 0,0521 0,08 768,93 15,43
Resvr R1 768,9390 0,1291 768.94 0.00
Tabel VI-40 Hasil Analisa Hdrolis Pada Pipa Jaringan MA. Saguling
Network Table - Links
Flo
Length Diameter Roughness Velocity Unit Headloss Friction Factor
w
Link
m mm LPS m/s m/km
ID
Pipe P2 75,99 50 130 0,08 0,04 0,07 0,044
Pipe P1 450,81 50 130 0,12 0,06 0,14 0,041
22
FINAL LAPORAN ANTARA
DETAIL PRASARANA PENYEDIAAN AIR BAKU DI KABUPATEN BANDUNG BARAT
23
FINAL LAPORAN ANTARA
DETAIL PRASARANA PENYEDIAAN AIR BAKU DI KABUPATEN BANDUNG BARAT
Tabel VI-41 Hasil Analisa Hidrolis Pada Bangunan Air MA. Suramanggala
Network Table - Nodes
Elevation Base Demand Demand Head Pressure
Node ID m LPS LPS m m
Hidran 1 680,818 0,1208 0,12 693,98 13,16
Hidran 3 688,000 0,1271 0,13 693,94 5,94
Hidran 4 685,939 0,0979 0,1 693,93 7,99
Resvr R1 694,012 0,3458 694,01 0
Tabel VI-42 Hasil Analisa Hdrolis Pada Pipa Jaringan MA. Suramanggala
Network Table - Links
Flo
Length Diameter Roughness Velocity Unit Headloss Friction Factor
w
Link
m mm LPS m/s m/km
ID
Pipe P1 189,99 50 130 0,12 0,06 0,16 0,041
Pipe P3 154,62 50 130 0,23 0,11 0,49 0,037
Pipe P4 94,72 50 130 0,1 0,05 0,11 0,042
24
FINAL LAPORAN ANTARA
DETAIL PRASARANA PENYEDIAAN AIR BAKU
DI KABUPATEN BANDUNG BARAT
G.
HASIL ANALISIS SURVEY GEOTEKNIK
VII.1 Umum
1
FINAL LAPORAN ANTARA
DETAIL PRASARANA PENYEDIAAN AIR BAKU
DI KABUPATEN BANDUNG BARAT
VII.3 Sondir
Pengujian sondir adalah suatu metode uji penekanan yang dilakukan untuk
menganalisa daya dukung tanah dan mengukur kedalaman lapisan tanah keras atau
pendukung yang biasa disebut tanah sondir. Dengan mengetahui kedalaman tanah keras
(sondir) yang akan dijadikan pijakan untuk tiang pancang atau pile maka kontraktor dapat
membuat desain pondasi yang sesuai dengan standart keamanan untuk menyokong kolom
bangunan. Sehingga pondasi tetap kuat menahan beban bangunan yang ada di atasnya dan
tidak mengalami penurunan (settlement) karena dapat membahayakan keselamatan
penghuni dan kestabilan struktur bangunan. Uji sondir termasuk ke dalam pengujian tanah
(soil test). Banyak kasus kegagalan struktur karena kontur tanah yang labil akibat sebelum
2
FINAL LAPORAN ANTARA
DETAIL PRASARANA PENYEDIAAN AIR BAKU
DI KABUPATEN BANDUNG BARAT
pembangunan tidak dilakukan pengujian sondir, efeknya pondasi menjadi tidak stabil dan
bangunan menjadi ambruk. Dengan melakukan pengujian sondir maka kontraktor dapat
membuat desain pondasi yang aman dengan melihat karakteristik tanah yang akan
dijadikan tempat untuk membuat bangunan. Namun, untuk melakukan uji sondir ini tentu
saja dibutuhkan alat bantu.
Gambar VII-53 Lokasi Survey Geoteknik Curug Goong Desa Cinengah Kecamatan Rongga
3
FINAL LAPORAN ANTARA
DETAIL PRASARANA PENYEDIAAN AIR BAKU
DI KABUPATEN BANDUNG BARAT
Gambar VII-54 Lokasi Survey Geoteknik MA. Suramanggala Desa Cinengah Kecamatan
Rongga
4
FINAL LAPORAN ANTARA
DETAIL PRASARANA PENYEDIAAN AIR BAKU
DI KABUPATEN BANDUNG BARAT
Gambar VII-55 Lokasi Survey Geoteknik Mata air Saguling Desa Cinengah Kecamatan
Rongga
5
FINAL LAPORAN ANTARA
DETAIL PRASARANA PENYEDIAAN AIR BAKU
DI KABUPATEN BANDUNG BARAT
6
FINAL LAPORAN ANTARA
DETAIL PRASARANA PENYEDIAAN AIR BAKU
DI KABUPATEN BANDUNG BARAT
7
FINAL LAPORAN ANTARA
DETAIL PRASARANA PENYEDIAAN AIR BAKU
DI KABUPATEN BANDUNG BARAT
8
FINAL LAPORAN ANTARA
DETAIL PRASARANA PENYEDIAAN AIR BAKU
DI KABUPATEN BANDUNG BARAT
9
FINAL LAPORAN ANTARA
DETAIL PRASARANA PENYEDIAAN AIR BAKU
DI KABUPATEN BANDUNG BARAT
10
FINAL LAPORAN ANTARA
DETAIL PRASARANA PENYEDIAAN AIR BAKU
DI KABUPATEN BANDUNG BARAT
2.0 2.0
2.0
4.0 4.0
4.0
6.0 6.0
6.0
8.0 8.0
8.0
10.0 10.0
10.0
Gambar VII-58 Grafik Cone Penetration Test saguling
11
FINAL LAPORAN ANTARA
DETAIL PRASARANA PENYEDIAAN AIR BAKU
DI KABUPATEN BANDUNG BARAT
6 Aterberg
7 Gradasi & Hidrometer
8 Triaxial UU
9 Konsolidasi
10 Compaction/ Standar Proctor
2. Tespit Suramanggala yang berlokasi di kanan dan Kiri Reservoar pada Koordinat
X : 761169 dan Y : 9E+06 adalah sebagai Berikut :
Tabel VII-46 Resume Tespit Suramanggala
3. Tespit Suramanggala yang berlokasi di kanan dan Kiri Reservoar pada Koordinat
X : 760304 dan Y : 9E+06 adalah sebagai Berikut :
Tabel VII-47 Resume Tespit Saguling
12
FINAL LAPORAN ANTARA
DETAIL PRASARANA PENYEDIAAN AIR BAKU
DI KABUPATEN BANDUNG BARAT
Kemudian dalam pengujian di tiga (3) mata air tersebut diambil sampel Hand bor
baik di semua titik Broncapter, Reservoar dan Hydran pada Gambar Lokasi Survey Di
atas. Adapun Hasil Pengujian Labnya adalah Sebagai Berikut :
Tabel VII-48 Resume Hasil Handbor Curug Goong
13
FINAL LAPORAN ANTARA
DETAIL PRASARANA PENYEDIAAN AIR BAKU
DI KABUPATEN BANDUNG BARAT
Hari : Kamis
Tanggal : 05 Agustus 2021
Tempat : Zoom Meetig
Pokok Pembahasan : Diskusi Interim
1
FINAL LAPORAN ANTARA
DETAIL PRASARANA PENYEDIAAN AIR BAKU
DI KABUPATEN BANDUNG BARAT
3 Pak Rendi a. Ketersediaan air belum jelas a. Debit telah dilakukan beberpa
diambil kapan. (lebih baik diambil kali di awal April, akhir mei, dan
setiap musim), dan dapat awal agustus, jadi ketersediaan
diperkuat dengan informasi desa, debit tsb sudah
apakah pernah kering atau menggambarkan air di setiap
gimana bulan. Berdasarkan info
b. Untuk kebutuhan air, proyeksi masyarakat, 3MA tsb tidak
penduduknya bagaimana. pernah kering meskipun musim
c. Unutk neraca bisa disampaikan kemarau.
secara bulanan, bulan2 apasaja b. Proyeksi penduduk dengan
yang mungkin tidak ada air mencari rata2 tren
d. Diberikan rekomendasi mengenai pertumbuhan pada tahun2
wilayah kepemilikan sehingga sebelumnya, kemudian laju
Mata Air tersebut dapat kontinu tersebut digunakan untuk
menghitung jumlah penduudk
pada tahun 2021 hingga 2045
4 Ibu Mardalina a. Di cek terkait pipa eksisting a. 3 MA tsb merupakan wilayah yg
b. Perhatikan manual OP tidak masuk program RPJIM
c. Pemilihan pipa hdpe sudah ok dan PAMSIMAS, Adapun pipa
dilapangan merupan pipa milik
2
FINAL LAPORAN ANTARA
DETAIL PRASARANA PENYEDIAAN AIR BAKU
DI KABUPATEN BANDUNG BARAT