2 100 %
2 2
6 dB
50 %
1 11 22
tc Ujung cacat
2 1
2
tc = (4 / 10) x 50 = 20
MENENTUKAN LOKASI DIMENSI CACAT LAMINASI
DENGAN PROBE NORMAL (Cont’)
Pencarian cacat laminasi Teknik Ekualisasi
2
2 100 %
2 Equel
1 11 22
2 2 0 4 8 10 00 4 8,2 10
tc
2 1 Ujung cacat
2
Tc = (4 / 10) x 50 = 20
MENENTUKAN LOKASI DAN DIMENSI CACAT DENGAN
MENGGUNAKAN PROBE SUDUT (Cont’)
memeriksa cacat pada BU
MENENTUKAN LOKASI DAN DIMENSI CACAT DENGAN
MENGGUNAKAN PROBE SUDUT (Cont’)
Menentukan Lokasi & Dimensi Cacat
20%
DAC
R = 10/4 T
Size = 8 x 9 mm
Frekuensi = 4 Mhz
100
%D
AC
20% DAC
Acceptance criteria ASME VIII Div. I App. 12
Imperfections which produce a response greater than 20% of the
reference level shall be investigated to the extent that the operator
can determine the shape, identity, and location of all such
imperfections and evaluate them in terms of the acceptance
standards given in (a) and (b) below.
(a) Indications characterized as cracks, lack of fusion, or
incomplete penetration are unacceptable regardless of length.
(b) Other imperfections are unacceptable if the indications
exceed the reference level amplitude and have lengths which
exceed:
(1) 1⁄4 in. (6 mm) for t up to 3⁄4 in. (19 mm);
(2) 1⁄3t for t from 3⁄4 in. to 21⁄4 in. (19 mm to 57 mm);
(3) 3⁄4 in. (19 mm) for t over 21⁄4 in. (57 mm).
Ketentuan Standard (ASME V Article 5) :
Temperatur
Untuk metoda Contact Testing, perbedaan temperatur antara Block
kalibrasi dengan permukaan benda uji yaitu dibawah 25° F (14°C).
Untuk metoda Immersion Testing, perbedaan temperatur couplant
untuk kalibrasi dengan temperatur couplant pada saat pengujian
dibawah 25° F (14°C) dari.
Scanning speed tidak lebih dari 6 in/s (150mm/s)