DETEKSI
GAS
POKOK BAHASAN
CONCENTRATION IN PROCESS
STREAM (CIPS)
KONSENTRASI GAS YANG DIUKUR LANGSUNG
DARI ALIRAN PROSES GAS (PIPELINE,
HEADER, DSB)
AKURASI UNTUK CIA
tergantung dari;
SEBERAPA DEKAT JARAK PENGUKURAN DENGAN
SUMBER GAS.
JENIS ALAT UKUR DAN METODE PENGUKURAN.
KONDISI ALAT UKUR.
PENEMPATAN ALAT UKUR, BERKENAAN DENGAN
ARAH ANGIN.
KECEPATAN SEMBURAN GAS .
PENYEBARAN (DISPERSION) DAN PENGENCERAN
(DILUTION).
TLV TWA (NILAI AMBANG BATAS)
THRESHOLD LIMIT VALUE/TLV - TIME WEIGHTED
BATASAN NAB PAPARAN YANG AMAN
RATA-RATA WAKTU KERJA,YAITU 8 JAM SETIAP HARI KERJA.
TLV - STEL
SHORT TERM EXPOSURE LIMIT STEL (BATAS
MAKSIMUM PEMAPARAN SESAAT) BATASAN NILAI
UNTUK 15 MENIT. DIPERBOLEHKAN 4 KALI PEMAPARAN
DARI STEL PADA SHIFT NORMAL, TETAPI HARUS ADA 60
MENIT WAKTU PEMISAH.
DETEKTOR AKTIF
DETEKTOR MENGGUNAKAN PRINSIP
KERJA MEKANIS/ELEKTRONIS
COMBUSTIBLE GAS DETECTOR
1. ELECTROCHEMICAL (EC)
2. CATALYTIC OXIDATION (CAT)
SENSOR
3. SENSOR INFRARED (IR)
ELECTROCHEMICAL (EC)
1. IR Light Source
2. Lens
3. Cuvette / Chamber
4. Mirror
5. Lens
6. Beam Splitter
7. Light Filter
8. Measure Detector
9. Light Filter
10. Comp. Detector
PERHATIAN
untuk pengukuran GAS di area
rendah atau tanpa Oxygen,
tidak bisa menggunakan sensor
CATALYTIC OXYDATION
UDARA
Fungsi gas test :
deteksi dini adanya
bahan bakar (uap gas0,
sehingga dapat dicegah
Proses terjadinya segitiga api
API
BAHAN BAKAR PANAS
Prinsip Pelaksanaan GAS TEST pada KERJA PANAS
% Volume Fuel
UEL
Batas Ledak
(Flamable / Explosion Range)
Oxygen
21% 10%
FLAMABLE RANGE
BATAS KONSENTRASI CAMPURAN ANTARA UAP BAHAN BAKAR
DENGAN UDARA YANG DAPAT TERBAKAR / MENYALA APABILA
MENDAPATKAN SUMBER PANAS YANG CUKUP.
34
FIXED CONTINUOUS GAS
MONITOR