Sumber: [5]
TYPE OF RIGID PAVEMENT
Karena panjang pelat lebih besar dari pada JPCP, retak tetap
terjadi pada interval yang sama, karena itu JRCP masih
mempunyai satu atau dua retakan pada pelatnya
Sumber: [5]
TYPE OF RIGID PAVEMENT
MISCELLANEOUS
1. Blowups
SURFACE DEFECTS 2. Faulting
3. Patch Deterioration
1. Map Cracking and Scaling 4. Water Bleeding and Pumping
2. Polished Aggregate 5. Punchouts (CRCP)
3. Popouts 6. Lane-Shoulder Dropoff
4. Plastic Shrinkage 7. Lane-Shoulder Separation
TYPE OF DISTRESSES
CRACKING
1. Corner Breaks
Slab fracture along a line intersecting the adjacent transverse and
longitudinal joints at a distance less than or equal to one-half the slab
length on both sides, measured from the corner of the slab.
Severity Levels
Low - The crack is not spalled for more than 10% of the length of the
crack. There is no measurable faulting, and the corner piece is not
broken into two or more pieces and has no loss of material.
Med - The crack is spalled at low severity for more than 10% of its total
length or faulting of the crack or joint is less than 1/2 in. (13 mm)
and the corner piece is not broken into two or more pieces
L M
High - The crack is spalled at moderate to high severity for more than 10%
of its total length or faulting of the crack or joint is greater than 1/2
in. (13 mm), or the corner piece is broken into two or more pieces.
H Sumber: [6]
TYPE OF DISTRESSES
CRACKING
1. Corner Breaks
Causes
Corner cracking in concrete pavements typically The development of pumping and associated base/subgrade erosion
develops due to repeated applications of heavy wheel requires four conditions:
loads near panel corners that exhibit high deflections • An erodible base/subgrade material
due to poor foundation support and/or poor support of • Free water in the pavement structure (usually due to surface infiltration
the transverse and longitudinal panel edges through unsealed joints and crack, along with inadequate drainage to
remove the water)
• Poor mechanical load transfer across the transverse joint, the
longitudinal joint, or both (i.e., high potential for differential movement
Poor support of the slab corner could result from one
across the joints when the slab it loaded)
or more of several mechanisms (e.g., unstable soils,
• Heavy dynamic loads to initiate differential movement across the
poor initial compaction, etc.) but is typically a result
joints.
of pumping and base/subgrade erosion.
When any one (or more) of these four conditions is removed, pumping
and associated erosion cannot develop, and corner cracking is highly
unlikely.
TYPE OF DISTRESSES
CRACKING
1. Corner Breaks
Causes
TYPE OF DISTRESSES
CRACKING
1. Corner Breaks
Causes
Stiffer bases are not necessarily better support under rigid pavements as they fail to
conform to the shape of the curled PCC slabs and may lead to loss of support,
higher curling stresses, and subsequent cracking
TYPE OF DISTRESSES
CRACKING
1. Corner Breaks
Causes
Mechanical Construction
Prevention
Pavement Layer Aspect Issue Consideration
Pavement Structure Joint Sealing and Water that enters and remains in Seal concrete pavement joints (especially the lane-shoulder
(General) Drainage the pavement structure can result in joint) and/or provide edge drains or day lighted aggregate
pumping base to quickly remove water from the pavement structure
Surface Layers (Concrete Joint Sealing Entry of water through unsealed Seal all pavement joints (especially longitudinal lane-
Pavement and Adjacent joints (especially longitudinal shoulder joints) in wet climates, especially when heavy trucks
Lanes or Shoulder) joints) can result in pumping and erodible foundation materials are present
Surface Layers (Concrete Concrete High CTE and contraction Use concrete with the lowest possible CTE (i.e., concrete
Pavement and Adjacent Coefficient of increases slab curl for any aggregate with low CTE, such as limestone, basalt, and
Lanes or Shoulder) Thermal Expansion temperature gradient, especially for granite rather than sandstone and quartz)
(CTE) longer panels
Base or Subgrade Erodibility Pumping and erosion of base or Use bound (stabilized or treated) base and subgrade materials,
subgrade leads to unsupported especially for facilities that carry heavy truck traffic in wet
conditions climates
Base or Subgrade Compaction Poor or inadequate compaction can Ensure that all unbound foundation layers are compacted to
lead to post-construction the specified target densities Ensure base course is
settlement of the base, reducing the homogenous and not segregated when placed
support provided to the slab
TYPE OF DISTRESSES
CRACKING
2. Durability “D” Cracking
“D” Cracking is a distress caused by freeze/thaw expansion of the
coarse aggregate which breaks down the concrete slab over time.
Dark color staining due to saturation near joints and closely spaced
fine crescent shaped cracks may lead to eventual disintegration of the
entire slab.
Severity Levels
Low - The “D” cracks are tight with no missing or loose pieces
Med - The “D” cracks are well-defined and some pieces are loose
or missing
Causes The process begins with water filling the pores in the
Three main factors: susceptible aggregates, which then undergoes cycles of
1) the concrete contains aggregates susceptible to D- freezing and thawing during the cold winter months. Since
cracking in sufficient quantity and size, the pore structure of the aggregates does not facilitate the
2) the concrete is exposed to sufficient moisture, and easy escape of water, the expansion due to the phase change
3) the concrete is exposed to repeated cycles of freezing from liquid water to ice results in the development of internal
and thawing stresses and under repeated freezing and thawing cycles, the
aggregates eventually fracture (see Figure 4.2) or dilate, thus
damaging the surrounding mortar.
Note: Susceptible aggregates generally have higher total
porosity and a higher proportion of medium-sized pores (0.1
to 5 µm), which allows for saturation of a significant
volume of water in freezable pore space
TYPE OF DISTRESSES
CRACKING
2. Durability “D” Cracking
Prevention
The most obvious and effective way of preventing D-cracking is to avoid the use of susceptible aggregates
Aggregate susceptibility to freeze-thaw deterioration is generally reduced as particle size is reduced. Many
highway agencies have had good success in minimizing D-cracking by reducing the maximum size of
susceptible coarse aggregate to 0.75 inches or less
TYPE OF DISTRESSES
CRACKING
3. Longitudinal Cracking
Cracks that are predominantly parallel to the pavement centerline
caused by a combination of repeated traffic loading, thermal
gradient curling, and repeated moisture loading
Severity Levels
Low - Crack widths < 3 mm with no spalling and no measurable
faulting or well-sealed cracks with a width that cannot be
determined.
Causes
Physical Material/Chemical
• Nonuniform slab support (variable stiffness, swelling soils,
frost heave, erosion, instability, etc.)
• Slab restraint • Thermal characteristics of the concrete (mainly a function of
• Inadequate saw cut depth aggregate type and content)
• Late sawing of joints • Shrinkage characteristics of the concrete (mainly a function
• Construction-related aspects (e.g., timing/depth of joint of paste content and w/cm ratio)
sawing, timing and effectiveness of curing) • Concrete mixture components and proportions that affect
• Construction and service traffic loadings (load magnitude, strength development
configuration, location, number of repetitions, and strength at
time of loading, etc.)
Longitudinal cracking typically develops due to a combination of two or more of the factors listed above (e.g.,
nonuniform support in combination with heavy traffic loads). In addition, the timing of crack development can vary
significantly, with some types of longitudinal cracking occurring very soon after construction (e.g., longitudinal
cracking caused by the late sawing of longitudinal joints) while types taking months or years to develop (e.g.,
longitudinal cracking caused by gradual loss of uniform pavement support coupled with heavy traffic loads)
TYPE OF DISTRESSES
CRACKING
3. Longitudinal Cracking
Prevention
Longitudinal cracking caused by nonuniform slab support
Foundation Element Aspect Issue Consideration
Base and Subgrade Compaction Poor or inadequate compaction can Ensure that all unbound foundation layers are compacted to
/Density lead to post-construction the specified target densities.
settlement of the base, reducing the
support provided to the slab.
Base and Subgrade Uniformity of Areas of nonuniformity in the Ensure base course is homogenous and not segregated when
Support foundation layers can lead to placed.
cracking Consider subgrade stabilization for plastic soils.
Base Base Erodibility Pumping and erosion of base Use widened lanes (if slab thickness and support conditions
beneath slab leads to unsupported permit) and/or tied concrete shoulders to reduce slab
conditions deflections that induce pumping.
Seal longitudinal joints (especially the lane-shoulder joint
and/or provide edge drains or daylighted aggregate base to
quickly remove water from the base.
Subgrade Swelling Soils Subgrade volumetric changes due Remove and replace small areas of swelling soils.
to variations in subgrade moisture Consider use of soils stabilization and membranes
contents
TYPE OF DISTRESSES
CRACKING
3. Longitudinal Cracking
Prevention
Longitudinal Cracking Due to Late Sawing or Inadequate Saw Cut Depth
The approach is to create a weakened plane or section
that cracks before stresses increase enough to cause
cracking at other less desirable locations
Prevention
TYPE OF DISTRESSES
CRACKING
3. Longitudinal Cracking
Prevention
TYPE OF DISTRESSES
CRACKING
4. Transverse and Diagonal Cracking
Cracks that are predominantly perpendicular to the pavement
centerline caused by a combination of repeated traffic loading,
thermal gradient curling, and repeated moisture loading
Severity Levels
Low - Crack widths < 3 mm with no spalling and no measurable
faulting or well-sealed cracks with a width that cannot be
determined.
Causes
Physical Material/Chemical
Transverse and diagonal cracking in JPCPs generally develop as the result of a combination of several of the factors
listed above. The timing of the crack appearance can vary significantly, with some cracking potentially occurring very
soon after construction (e.g., transverse cracking caused by the late sawing or omission of a jointing system), while
other cracking may take several years to develop (e.g., transverse fatigue cracking caused by repeated truck
applications)
TYPE OF DISTRESSES
CRACKING
4. Transverse and Diagonal Cracking
Prevention
Transverse Cracking Due to Volumetric Changes
Prevention
Transverse and Diagonal Cracking Caused by Settlement
and Poor Support
Prevention
Transverse Cracking Caused By Excessive Slab Lengths
The layout and spacing of transverse joints in concrete pavements is
one of the most common factors that can influence the development of
transverse and diagonal cracking on concrete pavements.
Prevention
Transverse Cracking Due to Poor Sawing Practices
Joint sawing is the common method of creating the transverse and
longitudinal joints in the concrete pavement. The saw cut is not
through the entire thickness of the slab but rather through a portion of
it, thereby creating a plane of weakness that encourages the crack to
occur at that location
Prevention
TYPE OF DISTRESSES
CRACKING
4. Transverse and Diagonal Cracking
Prevention
TYPE OF DISTRESSES
CRACKING
4. Transverse and Diagonal Cracking
Prevention
TYPE OF DISTRESSES
SURFACE DEFECTS
Causes
Map Cracking:
1. Late or Inadequate Curing: Curing can have a significant effect on the quality of the
concrete surface. An approved curing compound should be applied as soon as
possible to the surface and at the specified application rate to retain mix water to
support hydration. Late or inadequate curing impacts surface strength, abrasion
resistance, and surface durability
2. Batching Absorptive Aggregates: When the concrete contains aggregate particles with
a high volume of medium-sized pores (0.1 to 5 µm) that are easily saturated, they can
absorb moisture and, when freezing occurs, the associated volumetric expansion can
create enough pressure to rupture the aggregate and concrete surface
3. Alkali-silica reactivity (ASR): The result of this reaction is the formation of a gel that
expands in the presence of moisture and cracks the concrete matrix. ASR can result in
map cracking of the concrete or popouts on the surface of the concrete pavement and
can also contribute to cracking and spalling
4. Alkali-carbonate reactivity (ACR): The reaction is highly expansive and can lead to
deterioration of the concrete
TYPE OF DISTRESSES
SURFACE DEFECTS
1. Map Cracking and Scaling
Causes
Scaling:
1. Freeze-Thaw and Deicing Chemicals: Scaling is the loss of surface mortar and is
primarily related to the expansion of water in the concrete as it freezes. However, the
use of chemical deicers can accelerate the physical mechanisms responsible for
freeze-thaw deterioration of concrete.
2. Improper Surface Finishing and Curing: While finishing of most pavements takes
place prior to the appearance of bleed water, any overworking of the concrete surface,
or finishing while bleed water is present on the surface, can cause significant
weakening of the material at the surface of concrete and contribute to the formation of
scaling. Furthermore, late or inadequate curing can affect surface strength and
durability, which could lead to scaling.
3. Damage from Rain: When the surface and edges of newly placed concrete pavement
are not protected from rain, the surface can erode, washing away the paste; moreover,
the additional water at the concrete pavement surface can elevate the surface w/cm
ratio (particularly if worked into the surface), which can lead to map cracking and
scaling
TYPE OF DISTRESSES
SURFACE DEFECTS
1. Map Cracking and Scaling
Prevention
TYPE OF DISTRESSES
SURFACE DEFECTS
1. Map Cracking and Scaling
Prevention
TYPE OF DISTRESSES
SURFACE DEFECTS
2. Polished Aggregates (Surface Polishing)
Prevention
TYPE OF DISTRESSES
SURFACE DEFECTS
3. Popouts
Causes
Use of Unsound or Reactive Aggregates:
Near-surface aggregate particles with a high absorption and a
relatively low specific gravity can absorb moisture, which can
expand in freezing conditions and create pressures that cause
the particle to fragment and dislodge at the surface.
Prevention
1. Use durable mixtures with low w/cm ratios
2. Avoid the use of problem aggregates
TYPE OF DISTRESSES
SURFACE DEFECTS
4. Plastic Shrinkage
Causes
Rapid Evaporation:
Highly evaporative conditions (e.g., low humidity, windy
conditions, and exposure to direct sunlight) contribute to rapid
moisture loss from the surface, which can lead to the
development of plastic shrinkage cracking in the concrete.
TYPE OF DISTRESSES
JOINT DEFICIENCIES
1. Joint Seal Damage
Causes
TYPE OF DISTRESSES
JOINT DEFICIENCIES
2. Spalling Joints
Prevention
TYPE OF DISTRESSES
JOINT DEFICIENCIES
2. Spalling Joints
Prevention
TYPE OF DISTRESSES
JOINT DEFICIENCIES
2. Spalling Joints
Prevention
TYPE OF DISTRESSES
MISCELLANEOUS
1. Blowups
Severity Levels
Low - Does not impact traffic
High - Affects traffic and must be immediately repaired
TYPE OF DISTRESSES
MISCELLANEOUS
1. Blowups
Causes
TYPE OF DISTRESSES
MISCELLANEOUS
1. Blowups
Prevention
TYPE OF DISTRESSES
MISCELLANEOUS
2. Faulting
Severity Levels
Low - Less than or equal to 1/8 in. (3 mm) fault
Med - Greater than 1/8 to 3/8 in. (3 mm to 9.5 mm) fault
High - Greater than 3/8 in. (9.5 mm) fault
TYPE OF DISTRESSES
MISCELLANEOUS
2. Faulting
Causes
TYPE OF DISTRESSES
MISCELLANEOUS
2. Faulting
Prevention
TYPE OF DISTRESSES
MISCELLANEOUS
2. Faulting
Prevention
TYPE OF DISTRESSES
MISCELLANEOUS
3. Patch Deterioration
A portion (greater than or equal to 0.1 m2) or all of the original concrete
slab that has been removed and replaced or additional material applied to
the pavement after original construction.
Severity Levels
Low - Patch has, at most, low severity distress of any type, no
measurable faulting or settlement, and there is no loss of
patching material. Pumping is not evident.
Severity Levels
Low - Longitudinal and transverse cracks remain tight (minimal
width) spalling less than 3 in. (75 mm) faulting less than 1/4
in. (6 mm) with no loss of material and no patching
Med - Spalling greater than or equal to 3 in. (75 mm) and less
than 6 in. (150 mm) or faulting greater than or equal to 1/4
in. (6 mm) and less than 1/2 in. (13 mm)
High - Spalling greater than or equal to 6 in. (150 mm) or faulting
greater than or equal to 1/2 in. (13 mm) or concrete in
punchout area is loose and moves under traffic, or concrete
in punchout area is broken into two or more pieces
TYPE OF DISTRESSES
MISCELLANEOUS
5. Punchouts (CRCP)
Severity Levels
Low - The difference between the pavement edge and shoulder is >
25 and ≤ 50 mm
Med - The difference between the pavement edge and shoulder is
> 50 and ≤ 100 mm
High - The difference between the pavement edge and shoulder is
> 100 mm
TYPE OF DISTRESSES
MISCELLANEOUS
7. Lane-Shoulder Separation
Widening of the joint between the edge of the slab and the shoulder.
Severity Levels
Not applicable. Severity levels can be defined by categorizing the
measurements taken. A complete record of the measurements taken is
much more desirable, however, because it is more accurate and
repeatable than severity levels.
How to Measure
Record to the nearest millimeter at intervals of 15.25 m along the
lane-to-shoulder joint. Indicate whether the joint is well-sealed (yes or
no) at each location.