mp1 - (mp2+md) = 0
mp1 = mp2 + md
Laju alir produk debu sangat kecil sehingga dapat diabaikan (md = 0)
mp1 = mp2
dengan, Qin = laju alir panas udara dan produk masuk cooler, kJ/jam
(𝑄𝑖𝑛−𝑄𝑙𝑜𝑠𝑠)/
d) Perhitungan Suhu Udara Pendingin Ouput Ideal 𝑄𝑖𝑛 𝑥 100%
Kondisi ideal --> Qloss = 0
Qtransfer = mp.Cpp.dTp
Qtransfer = mu.Cpu.dTu
dTu = Qtransfer/(mu.Cpu)
(Tu, out - Tu, in) = Qtransfer/(mu.Cpu)
Tu, out = Tu, in + (Qtransfer/(mu.Cpu))
mu = Qtransfer/(Cpu.dTu)
Fu = mu/ρu
353.15 K
318.15 K
0.33 kkal/kg.oC
293.15 K
323.15 K
0.24 kkal/kg.oC at (27oC)
308.15 K
(Range 4 - 10)
In -4352178.60 kJ/jam
Out -4308656.81 kJ/jam
dH -43521.79 kJ/jam
Qtransfer kJ/jam
Massa udara masuk mu,in = 144350.865672 kg/jam
Suhu udara masuk Tu,in = 30 oC
Suhu udara keluar Tu,out = 20 oC
Specific heat udara Cp,u = 1.01 kJ/(kg.K)
Suhu ammonia masuk Ta,in = -25 oC
Suhu ammonia keluar Ta,out =