Anda di halaman 1dari 21

TRANSFORMATOR

Oleh:
Ir. Sutedjo, MT.
Ony Asrarul Qudsi, ST., MT

Program Studi Teknik Elektro Industri


Departemen Teknik Elektro
Politeknik Elektronika Negeri Surabaya

Trafo Transmisi dan Distribusi


Tujuan
 Tujuan Instruksional Umum
Mahasiswa mampu memahami pinsip kerja dan cara penggunaan , konsep
dasar transformator distribusi tenaga listrik, klasifikasi transformator, serta
kinerja transformator pada distribusi tenaga listrik
 Tujuan Instruksional Khusus
Mahasiswa dapat memahami secara menyeluruh bagian-bagian transformator
tegangan tinggi
Outline
 Bagian-bagian trafo transmisi
Oil Level Indicator
On Load Tap Changer
On Load Tap Changer
Motor Drive
Motor Drive
Cooling System
Cooling System

Suhu pada transformator yang


sedang beroperasi akan
dipengaruhi oleh kualitas tegangan
jaringan, losses pada trafo itu
sendiri dan suhu lingkungan. Suhu
operasi yang tinggi akan
mengakibatkan rusaknya isolasi
kertas pada transformator. Oleh
karena itu pendinginan yang
efektif sangat diperlukan.
Neutral Grounding Resistant

NGR adalah sebuah tahanan


yang dipasang serial dengan
neutral sekunder pada
transformator sebelum terhubung
ke ground/tanah. Tujuan
dipasangnya NGR adalah untuk
mengontrol besarnya arus
gangguan yang mengalir dari sisi
neutral ke tanah.
NGR ada jenis cairan dan solid
Technical Specifications

1. 3-phase unit/bank of single phase units


2. Separate winding/auto transformer
3. Rated voltage (HV/LV/TV)
4. Rated frequency
5. Cooling system
6. Vector group
7. Rated power
Technical Specifications

9. Rated current (HV/LV/TV)


10. Insulation level (HV/LV/TV/Neutral)
a) LIWL (winding /bushing)
b) SIWL (winding /bushing)
c) PFWL (winding /bushing)
11. Creepage distance
Technical Specifications

12. Continuous power rating at principal tap:


12.1. at first stage of cooling
a) HV Winding
b)LV Winding
c)TV Winding
12.2. at second stage of cooling
a) HV Winding
b)LV Winding
c)TV Winding
12.3. at third stage of cooling
a) HV Winding
b)LV Winding
c)TV Winding
Technical Specifications

13. Maximum temperature rise


a) Oil
b) Winding
c) Hottest spot
14. Insulation level (HV/LV/TV/Neutral)
a) LIWL (winding /bushing)
b) SIWL (winding /bushing)
c) PFWL (winding /bushing)
Technical Specifications

15. Positive sequence impedance at 75oC on principle


tapping (max./min. tap voltage) and:
a) between HV & LV winding
b) between HV & TV winding (if applicable)
c) between TV & LV winding (if applicable)
Technical Specifications

16. Rated short circuit strength on windings (HV/LV/TV)


17. Short circuit duration
18. No load losses
19. Load losses
20. Type of winding
21. Type of insulation of windings (uniform/graded)
a)HV
b)LV
c)TV
22. Max. sound level (dB)
Technical Specifications
23. Tap changer
a) Type (oil/vacuum)
b) rated current
c) rated voltage
d) total range
e) total number of steps
f) variation per step
g) position of tapping
h) insulation level
Power Transformer Outline Drawing
Referensi
 Pabla, Power Distribution, McGraw-Hill, 1981
 Jones, Distribution System Engineering, John Wiley,
1986
 E. Lakervi & EJ Holmen, Electricity Distribution
Design, IEEE Power Engineering Network Design,
1989
 Handbook of Electric Distribution
Referensi
 Materi Pra Jabatan Bidang Distribusi PT. PLN
 Buku PT. PLN, 2010
 Standar Kompetensi Tenaga Teknik
Ketenagalistrikan Bidang Distribusi Sub Bidang
Operasi, Kementerian ESDM
 Stepen J. Chapman, Electric Machinery Fundamental