TUGAS KHUSUS
56
57
Tabel 5.4 Kondisi operasi udara dan steam input aktual secondary reformer
Udara Steam Udara
Temperatur Flowinlet
Tanggal Flowinlet
e (ton/hr)
(E3NM/hr)
(0C)
17/08/2020 44,17 599,53 10,30
24/08/2020 44,16 590,92 10,00
31/08/2020 43,68 593,23 11,58
(Sumber: Control panel Ammonia P1B, 2020)
Data komposisi
Tabel 5.6 Komposisi natural gas input aktual primary reformer
Komponen Tanggal
17/08/2020 24/08/2020 31/08/2020
58
1 Primary 3 Secondary 6
T=
922,08 ºC
Komposisi :
(%mol)
CH4 = 0,54
CO =
10,50
CO2 =
10,20
60
N2 =
22,16
H2 =
56,31
Ar = 0,29
H2O = sisa reaksi
7
CH4 = 0.31
CO = 0.24
CO2 = 15.60
N2 = 20.52
H2 = 59.92
Ar = 0.24
H2O = sisa reaksi
Gambar 5.1 Diagram Alir Proses High Temperatur Shift Converter (HTSC)
Tabel 5.11 Neraca massa primary reformer pada tanggal 17 Agustus 2020
Input Output
Komponen
Mol (kmol) Massa (kg) Mol (kmol) Massa (kg)
CH4 1179,3942 18917,4829 447,5349 7178,4591
C2H6 60,8400 1829,4588 0,0000 0,0000
C3H8 9,5000 418,9500 0,0000 0,0000
i-C4H10 2,1100 122,6332 0,0000 0,0000
n-C4H10 2,1100 122,6332 0,0000 0,0000
61
Tabel 5.12 Neraca massa secondary reformer pada tanggal 17 Agustus 2020
Input Output
Komponen
mol (kmol) massa (kg) mol (kmol) massa (kg)
CH4 447,53 7178,46 34,69 556,44
CO 338,45 9479,87 674,54 18893,81
CO2 578,81 25460,38 655,27 28830,24
H2O 3709,19 66802,55 3500,58 63045,45
N2 509,85 14281,02 509,85 14281,02
Ar 0,01 0,40 0,01 0,40
H2 3234,78 6534,26 4292,21 8670,27
O2 128,93 4124,34 0,00 0,00
Total 8947,36 133861,27 9644,02 133861,01
Tabel 5.15 Neraca massa total secondary reformer pada tanggal 24 Agustus 2020
Input Output
Komponen
mol (kmol) massa (kg) mol (kmol) massa (kg)
CH4 454,23 7285,84 37,54 602,10
CO 324,61 9092,24 649,99 18206,12
CO2 567,24 24963,99 657,85 28951,86
H2O 3683,80 66322,20 3436,15 61885,15
63
Tabel 5.18 Neraca massa total Secondary Reformer pada tanggal 31 Agustus
2020
64
Input Output
Komponen
mol (kmol) massa (kg) mol (kmol) massa (kg)
CH4 436,49 7001,21 42,79 686,36
CO 316,42 8862,99 608,79 17052,19
CO2 585,91 25785,94 687,24 30245,36
H2O 3750,06 67515,78 3511,88 63248,97
N2 507,56 14125,90 507,53 14215,90
Ar 0,26 10,34 0,26 10,34
H2 3198,93 6461,83 424,49 8503,47
O2 128,42 4108,24 0,00 0,00
Total 8924,01 133962,18 9582,98 133962,59
Tabel 5.19 Neraca massa total HTSC pada tanggal 31 Agustus 2020
Input Output
Komponen
kmol kg kmol kg
CH4 42,79 686,36 19,23 308,41
CO 608,79 17052,19 230,02 6442,87
CO2 687,24 30245,36 1089,57 48010,98
H2O 3511,88 63248,96 3085,99 55578,61
H2 4224,49 8503,47 4651,00 9395,02
N2 507,53 14215,90 507,53 14215,90
Ar 0,26 10,34 0,26 10,34
Total 9582,98 133962,59 9583,59 133962,14
Q2 Panas Sensibel
27326942.08 94%
Syngas Output
Q3 Panas Reaksi
5050603.77 17%
Total Reaksi
Q4 Loss 1731211.64 6%
Total 29058153.72 100% 29058153.72 100%
Q2 Panas Sensibel
26592833.18 94%
Syngas Output
Q3 Panas Reaksi
4678512.23 17%
Total Reaksi
Q4 Loss 1759449.88 6%
Total 28352283.06 100% 28352283.06 100%
Q2 Panas Sensibel
27044933.68 95%
Syngas Output
66
Q3 Panas Reaksi
4505796.66 16%
Total Reaksi
Q4 Loss 1464266.91 5%
Total 28509200.59 100% 28509200.59 100%
5.3 Evaluasi kinerja High Temperature Shift Converter pada Unit Purifikasi.
64,20% yang jika dibandingkan dengan efisiensi desain pada alat HTSC
yaitu 80,61%.
HTSC memiliki nilai efisiensi aktual yang dibawah nilai efisiensi desain,
dikarenakan temperatur operasi secara aktual pada HTSC dibawah temperatur
desain optimum alat HTSC. Adapun faktor yang mempengaruhi efisiensi termal
pada alat HTSC yaitu komposisi umpan masuk HTSC merupakan komposisi
keluar dari reformer sehingga besarnya komposisi umpan masuk HTSC juga
sangat berpengaruh. Penyebab turunnya efisiensi HTSC juga karena kinerja katalis
Fe2O3 pada HTSC telah mencapai batas pakai (End of Run) yang mengakibatkan
berkurangnya kereaktifan sehingga reaksi yang terjadi pada HTSC tidak
berlangsung secara optimal sehingga harus dilakukan pergantian katalis agar dapat
meningkatkan konversi CO menjadi CO2 yang dapat meningkatkan efisiensi
termal HTSC. Kinerja katalis yang baik akan mempercepat laju reaksi, sehingga
dapat mempercepat kesetimbangan dan meningkatkan efisiensi termal.