SKEMA PEMANFAATAN FLUE GASES

TAHAP 1
Diketahui Data-data sebagai berikut :
Laju Alir Air Umpan Boiler = 4500 kg/jam LHV Solar = 9800 kcal/kg
Suhu Air Umpan Masuk Economizer = 27 oC Ρsolar = 0,86 kg/L
Suhu Air Umpan Masuk Boiler = 70 oC Efisiensi Pembakaran = 80%
Cp air = 1,1 kkal/kgoC Harga Solar = Rp 7500 / Liter
Blowdown = 4 % Debit flue gases = 18 kg/kg bahan bakar
Tekanan Steam = 10 bar Suhu Flue gases (Tfgi) = 200 oC
BP air (10 bar) = 180 oC Pabrik beroperasi 3 shift/hari, dengan 1 shift 8 jam
Ditanya:
Suhu flue gases keluar cerobong = …. oC
TAHAP 2
SEBELUM DILAKUKAN PEMANFAATAN FLUE GASES
• Mencari Q feed water
Q1 = m Cp ΔT
= 4500 kg/jam x 1,1 kkal/kgoC x (180 – 27)oC
= 757.350 kcal/jam
Q2 = m λ
= 4500 kg/jam x 481,346 kcal/kg
= 2.166.057 kcal/jam
Q3 = m Cp ΔT
= 4500 kg/jam x 0,442 kcal/kgoC x (250 – 180) oC
= 139.230 kcal/jam
Q total = 3.062.637 kcal/jam
• Mencari Harga Solar
Q solar = Q / η
3.062.637 kcal/jam
= 0,8

= 3.828.296,25 kcal/jam
3.828.296,25 kcal/jam
Massa Solar = 9800 𝑘𝑐𝑎𝑙/𝑘𝑔

= 390,642 kg/jam
390,642 kg/jam
Volume Solar = 0,86 𝑘𝑔/𝐿

= 454,235 L/jam
Harga Solar = 454,235 L/jam x Rp 7500 / L
= Rp 3.406.766 /jam
• Mencari Laju Flue Gases
Q flue gases = 390,642 kg/jam x 18 kg/kg bahan bakar
= 7.031,556 kg/jam
Cpfg = 1,097 kJ/kgoC
= 0,262 kcal/kgoC
• Mencari Suhu Flue Gases Keluar Cerobong
Q flue gases = Q feed water
mfg x Cpfg x (200 – Tfgo) = mfw x Cpfw x (Tfwo – Tfwi)
7.031,556 kg/jam x 0,262 kcal/kgoC x (200 – Tfgo) = 4500 kg/jam x 1,1 kcal/ kgoC x (70
- 27)oC
368.453,5344 kcal/jam - 1842,268 kcal/jamoC Tfgo = 212.850 kcal/jam
Tfgo = 84,463 oC
SETELAH DILAKUKAN PEMANFAATAN FLUE GASES
• Mencari Q feed water
Q1 = m Cp ΔT
= 4500 kg/jam x 1,1 kkal/kgoC x (180 – 70)oC
= 544.500 kcal/jam
Q2 = m λ
= 4500 kg/jam x 481,346 kcal/kg
= 2.166.057 kcal/jam
Q3 = m Cp ΔT
= 4500 kg/jam x 0,442 kcal/kgoC x (250 – 180) oC
= 139.230 kcal/jam
Q total = 2.849.787 kcal/jam
• Mencari Harga Solar
Q solar = Q / η
2.849.787 kcal/jam
= 0,8

= 3.562.233,75 kcal/jam
3.562.233,75 kcal/jam
Massa Solar = 9800 𝑘𝑐𝑎𝑙/𝑘𝑔

= 363,493 kg/jam
363,493 kg/jam
Volume Solar = 0,86 𝑘𝑔/𝐿

= 422,667 L/jam
Harga Solar = 422,667 L/jam x Rp 7500 / L
= Rp 3.169.999,184 /jam
Cost Penghematan Bahan Bakar / Jam = Rp 3.406.766 /jam - Rp 3.169.999,184 /jam
= Rp 236.766,8157 /jam x 24 jam/hari x 30
hari/bulan
= Rp 170.472.107,3 /bulan
TAHAP 3
Investasi Economizer = Rp 1.000.000.000
investasi
PBP =
𝑐𝑜𝑠𝑡 𝑝𝑒𝑛𝑔ℎ𝑒𝑚𝑎𝑡𝑎𝑛
Rp 1.000.000.000
= Rp 170.472.107,3 /bulan

= 5,866 bulan
Simpulan :
Setelah dilakukan pemanfaatan suhu flue gases sebagai economizer (pemanasan awal air umpan
boiler) maka didapatkan cost penghematan sebesar Rp 170.472.107,3 /bulan, sehingga Pay Back
Period yang didapat sebesar 5,866 bulan.
Suhu keluaran flue gases pun dari yang awalnya 200oC dapat berkurang menjadi 84,463 oC.
Rekomendasi :
Karena suhu keluaran cerobong masih tinggi (200oC) sehingga dapat dimanfaatkan sebagai
economizer. Dengan memanfaatkan suhu flue gases dapat menurunkan biaya bahan bakar.